Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Discovery of hard-spectrum γ -ray emission from the BL Lacertae object 1ES 0414+009

1ES 0414 + 009 (z = 0.287) is a distant high-frequency-peaked BL Lac object, and has long been considered a likely emitter of very-high-energy (VHE, E > 100 GeV) γ-rays due to its high X-ray and radio flux. Observations in the VHE γ-ray band and across the electromagnetic spectrum can provide insights into the origin of highly energetic particles present in the source and the radiation processes at work. Because of the distance of the source, the γ-ray spectrum might provide further limits on the level of the extragalactic background light (EBL). Methods. We report observations made between October 2005 and December 2009 with H.E.S.S., an array of four imaging atmospheric Cherenkov telescopes. Observations at high energies (HE, 100 MeV–100 GeV) with the Fermi-LAT instrument in the first 20 months of its operation are also reported. To complete the multi-wavelength picture, archival UV and X-ray observations with the Swift satellite and optical observations with the ATOM telescope are also used. Based on the observations with H.E.S.S., 1ES 0414 + 009 is detected for the first time in the VHE band. An excess of 224 events is measured, corresponding to a significance of 7.8σ. The photon spectrum of the source is well described by a power law, with photon index of ΓVHE = 3.45 ± 0.25stat ± 0.20syst. The integral flux above 200 GeV is (1.88 ± 0.20stat ± 0.38syst) × 10-12 cm-2 s-1. Observations with the Fermi-LAT in the first 20 months of operation show a flux between 200 MeV and 100 GeV of (2.3 ± 0.2stat) × 10-9 erg cm-2 s-1, and a spectrum well described by a power-law function with a photon index ΓHE = 1.85 ± 0.18. Swift/XRT observations show an X-ray flux between 2 and 10 keV of (0.8-1) × 10-11 erg cm-2 s-1, and a steep spectrum ΓX = (2.2-2.3). Combining X-ray with optical-UV data, a fit with a log-parabolic function locates the synchrotron peak around 0.1 keV. Although the GeV–TeV observations do not provide better constraints on the EBL than previously obtained, they confirm a low density of the EBL, close to the lower limits from galaxy counts. The absorption-corrected HE and VHE γ-ray spectra are both hard and have similar spectral indices (≈1.86), indicating no significant change of slope between the HE and VHE γ-ray bands, and locating the γ-ray peak in the SED above 1–2 TeV. As for other TeV BL Lac objects with the γ-ray peak at such high energies and a large separation between the two SED humps, this average broad-band SED represents a challenge for simple one-zone synchrotron self-Compton models, requiring a high Doppler factor and very low B-field.

79 ASTRONOMY AND ASTROPHYSICS↗

THE NORTHERN WRAPS OF THE SAGITTARIUS STREAM AS TRACED BY RED CLUMP STARS: DISTANCES, INTRINSIC WIDTHS, AND STELLAR DENSITIES

We trace the tidal Stream of the Sagittarius dwarf spheroidal galaxy (Sgr dSph) using Red Clump (RC) stars from the catalog of the Sloan Digital Sky Survey-Data Release 6, in the range 150{sup 0} {approx}< R.A. {approx}< 220{sup 0}, corresponding to the range of orbital azimuth 220{sup 0} {approx}< {Lambda} {approx}< 290{sup 0}. Substructures along the line of sight (los) are identified as significant peaks in the differential star count profiles (SCPs) of candidate RC stars. A proper modeling of the SCPs allows us to obtain (1) {<=}10% accurate, purely differential distances with respect to the main body of Sgr, (2) estimates of the FWHM along the los, and (3) estimates of the local density, for each detected substructure. In the range 255{sup 0} {approx}< {Lambda} {approx}< 290{sup 0} we cleanly and continuously trace various coherent structures that can be ascribed to the Stream, in particular: the well-known northern portion of the leading arm, running from d {approx_equal} 43 kpc at {Lambda} {approx_equal} 290{sup 0} to d {approx_equal} 30 kpc at {Lambda} {approx_equal} 255{sup 0}, and a more nearby coherent series of detections lying at a constant distance d {approx_equal} 25 kpc, that can be identified with a wrap of the trailing arm. The latter structure, predicted by several models of the disruption of Sgr dSph, was never traced before; comparison with existing models indicates that the difference in distance between these portions of the leading and trailing arms may provide a powerful tool to discriminate between theoretical models assuming different shapes of the Galactic potential. A further, more distant wrap in the same portion of the sky is detected only along a couple of los. For {Lambda} {approx}< 255{sup 0} the detected structures are more complex and less easily interpreted. We are confident of being able to trace the continuation of the leading arm down to {Lambda} {approx_equal} 220{sup 0} and d {approx_equal} 20 kpc; the trailing arm is seen up to {Lambda} {approx_equal} 240{sup 0} where it is replaced by more distant structures. Possible detections of more nearby wraps and of the Virgo Stellar Stream are also discussed. These measured properties provide a coherent set of observational constraints for the next generation of theoretical models of the disruption of Sgr.

79 ASTRONOMY AND ASTROPHYSICS↗

Mass calibration of distant SPT galaxy clusters through expanded weak-lensing follow-up observations with HST, VLT, & Gemini-South

Expanding from previous work, we present weak-lensing (WL) measurements for a total sample of 30 distant (z median = 0.93) massive galaxy clusters from the South Pole Telescope Sunyaev–Zel’dovich (SPT-SZ) Survey, measuring galaxy shapes in Hubble Space Telescope (HST) Advanced Camera for Surveys images. We remove cluster members and preferentially select z ≳ 1.4 background galaxies via V - I colour, employing deep photometry from VLT/FORS2 and Gemini-South/GMOS. We apply revised calibrations for the WL shape measurements and the source redshift distribution to estimate the cluster masses. In combination with earlier Magellan/Megacam results for lower-redshifts clusters, we infer refined constraints on the scaling relation between the SZ detection significance and the cluster mass, in particular regarding its redshift evolution. The mass scale inferred from the WL data is lower by a factor $0.76^{+0.10}_{-0.14}$ (at our pivot redshift z = 0.6) compared to what would be needed to reconcile a flat Planck νΛCDM cosmology (in which the sum of the neutrino masses is a free parameter) with the observed SPT-SZ cluster counts. In order to sensitively test the level of (dis-)agreement between SPT clusters and Planck, further expanded WL follow-up samples are needed.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation-Length Requirements in the Loads Analysis of Offshore Floating Wind Turbines: Preprint

The goal of this paper is to examine the appropriate length of a floating offshore wind turbine (FOWT) simulation - a fundamental question that needs to be answered to develop design requirements. To examine this issue, a loads analysis of an example FOWT was performed in FAST with varying simulation lengths. The offshore wind system used was the OC3-Hywind spar buoy, which was developed for use in the International Energy Agency Code Comparison Collaborative Project and supports NREL's offshore 5-megawatt baseline turbine. Realistic metocean data from the National Oceanic and Atmospheric Administration and repeated periodic wind files were used to excite the structure. The results of the analysis clearly show that loads do not increase for longer simulations. In regards to fatigue, a sensitivity analysis shows that the procedure used for counting half cycles is more important than the simulation length itself. Based on these results, neither the simulation length nor the periodic wind files affect response statistics and loads for FOWTs (at least for the spar studied here); a result in contrast to the offshore oil and gas industry, where running simulations of at least 3 hours in length is common practice.

17 WIND ENERGY↗

Measurements of $\sigma(V+D^{*})/\sigma(V)$ in $9.7$ fb$^{-1}$ at CDF Run II

The Standard Model of particle physics has been remarkably successful, but the non-perturbative features of quantum chromodynamics must be tested and modeled with data. There have been many such tests, focused primarily on the use of jet-based probes of heavy flavor (bottom and charm quark) production at hadron colliders. In this thesis, we propose and test a strategy for identifying heavy flavor in events containing a W or Z vector boson (a V boson); this technique probes a much lower energy regime than can be explored by jet-based methods. In a sample of W and Z events skimmed from 9.7 fb -1 of high- pT electron and muon data from CDF Run II p p collisions at center of mass energy √s = 1:96 GeV , we identify charm by fully reconstructing D* (2010) → D 0 (→ Kπ )π s decays at the track level. Using a binned fit of Δm=m(Kππ s ) m(Kπ ) to count reconstructed D* candidates, we then unfold these raw counts with acceptance values derived from Monte Carlo, and present measurements of σ(W + D* )/ σ(W) and σ(Z + D* )/ σ(Z) in the W/Z leptonic decay channels. All measurements are found to be in agreement with the predictions of Pythia 6.2 (PDF set CTEQ5L). These results include the first measurement of W/Z + c production in events with zero jet objects at the Tevatron, and the first measurement of W/Z +c production with p T (c) < 15 GeV at the Tevatron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

2024 Results for Avian Monitoring at the Technical Area 36 Minie Site, Technical Area 39 Point 6, Technical Area 16 Burn Ground, and DARHT at Los Alamos National Laboratory

Los Alamos National Laboratory (LANL) biological subject matter experts in the Environmental Protection and Compliance Division initiated a multi-year program in 2013 to monitor avifauna (birds) at two open detonation sites and one open burn site on LANL property. Additional monitoring began in 2017 at a third firing site, the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility. In this annual report, we compare monitoring results from these efforts among years to identify and evaluate firing and open burn site impacts on the local bird community. The objectives of this study are • to determine whether LANL operations impact bird abundance, species richness, or diversity; • to examine occupancy and nest success of secondary-cavity nesting birds that use nest boxes; and • to examine chemical concentrations (such as radionuclides, inorganic elements, and/or organic compounds) in nonviable eggs and deceased nestlings that are collected opportunistically with the upper-level bounds of background concentrations, when available. During May through July 2024, LANL biologists completed multiple avian point count surveys at each of the following treatment sites: • Technical Area (TA) 36 Minie Site, • TA-39 Point 6, • TA-16 Burn Ground, and • DARHT. We recorded a total of 1,088 birds that represented 65 species at the four treatment sites and compared these results with data from their associated control sites. In 2024, abundance and species richness at treatment and control sites continued to trend similarly from year to year, with minor random deviations expected from bird communities. Species richness at firing sites differed little from the previous year’s values. Two new bird species were observed at the firing sites—cedar waxwing (Bombycilla cedrorum) and pinyon jay (Gymnorhinus cyanocephalus). Shannon diversity values at TA-36 Minie Site, TA-39, and DARHT were statistically higher than one or more of their associated controls. Annual species diversity at treatment sites was high in 2024 across all firing sites relative to similar habitat control sites. We also monitored avian nest boxes to compare occupancy and nest success data from nest boxes at treatment sites with the overall avian nest box monitoring network and against a subset of relevant control sites. Nest box success has decreased at both treatment and control sites since monitoring began, suggesting that overlapping climatic factors are responsible for patterns of declining nest success. In 2024, nonviable avian eggs and one nestling were opportunistically collected at Bandelier National Monument, TA-16 Burn Ground, TA-36 Minie, TA-39 Point 6, and DARHT. All egg samples and the one nestling sample were evaluated for per- and polyfluoroalkyl substances, which were detected from all locations, including the control site at Bandelier National Monument. Overall results from 2024 continue to suggest that operations at the four treatment sites are not negatively impacting bird populations. This long-term project will continue to monitor for any changes over time.

54 ENVIRONMENTAL SCIENCES↗

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Screening and Spectral Summing of LANL Empty Waste Drums - 13226

Empty 55-gallon drums that formerly held transuranic (TRU) waste (often over-packed in 85- gallon drums) are generated at LANL and require radiological characterization for disposition. These drums are typically measured and analyzed individually using high purity germanium (HPGe) gamma detectors. This approach can be resource and time intensive. For a project requiring several hundred drums to be characterized in a short time frame, an alternative approach was developed. The approach utilizes a combination of field screening and spectral summing that was required to be technically defensible and meet the Nevada Nuclear Security Site (NNSS) Waste Acceptance Criteria (WAC). In the screening phase of the operation, the drums were counted for 300 seconds (compared to 600 seconds for the typical approach) and checked against Low Level (LL)/TRU thresholds established for each drum configuration and detector. Multiple TRU nuclides and multiple gamma rays for each nuclide were evaluated using an automated spreadsheet utility that can process data from up to 42 drums at a time. Screening results were reviewed by an expert analyst to confirm the field LL/TRU determination. The spectral summing analysis technique combines spectral data (channel-by-channel) associated with a group of individual waste containers producing a composite spectrum. The grouped drums must meet specific similarity criteria. Another automated spreadsheet utility was used to spectral sum data from an unlimited number of similar drums grouped together. The composite spectrum represents a virtual combined drum for the group of drums and was analyzed using the SNAP{sup TM}/Radioassay Data Sheet (RDS)/Batch Data Report (BDR) method. The activity results for a composite virtual drum were divided equally amongst the individual drums to generate characterization results for each individual drum in the group. An initial batch of approximately 500 drums were measured and analyzed in less than 2 months in 2011. A second batch of approximately 500 more drums were measured and analyzed during the following 2 1/2 months. Four different HPGe detectors were employed for the operation. The screening and spectral summing approach can reduce the overall measurement and analysis time required. However, developing the technical details and automation spreadsheets requires a significant amount of expert time prior to beginning field operations and must be considered in the overall project schedule. This approach has continued to be used for characterizing several hundred more empty drums in 2012 and is planned to continue in 2013. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing Sensor Count and Placement to Detect Bond Wire Lift-Offs and Surface Defects in High-Power IGBT Modules Using Low-Cost Piezo-Electric Resonators

This manuscript presents the most recent results and findings to identify bond wire lift-offs and surface defects in high-power isolated gate bipolar junction transistor (IGBT) modules. The authors of this manuscript formerly proposed a low-cost, piezoelectric resonator-based measurement unit to detect bond wire related degradation in larger IGBT modules. Since high-power IGBT modules are expensive, it was apparent that evaluating our proposed method by inducing controlled damage to fresh (new) IGBTs may not be cost-effective especially when multiple sets of data need to be captured by inducing damage to different levels. In order to overcome this limitation, IGBT bond wires have been mimicked using a 3D printed enclosure, a PCB, and copper wires with dimensions very closely resembling a real IGBT. Using this method, multiple test devices can be built at the cost of a real IGBT, and the proposed technique could be fine-tuned without damaging expensive, real IGBTs. Our recent findings can be used to determine real IGBT degradation and bond wire lift-offs using only two sensors, as opposed to six transducers used in the first iteration of the setup. In addition to optimizing the sensor count, we have also identified the best possible locations of these sensors by attempting multiple placements inside the IGBT casing.

condition monitoring↗

Abrolhos Bank Reef Health Evaluated by Means of Water Quality, Microbial Diversity, Benthic Cover, and Fish Biomass Data

The health of the coral reefs of the Abrolhos Bank (southwestern Atlantic) was characterized with a holistic approach using measurements of four ecosystem components: (i) inorganic and organic nutrient concentrations, [1] fish biomass, [1] macroalgal and coral cover and (iv) microbial community composition and abundance. The possible benefits of protection from fishing were particularly evaluated by comparing sites with varying levels of protection. Two reefs within the wellenforced no-take area of the National Marine Park of Abrolhos (Parcel dos Abrolhos and California) were compared with two unprotected coastal reefs (Sebastia˜o Gomes and Pedra de Leste) and one legally protected but poorly enforced coastal reef (the ‘‘paper park’’ of Timbebas Reef). The fish biomass was lower and the fleshy macroalgal cover was higher in the unprotected reefs compared with the protected areas. The unprotected and protected reefs had similar seawater chemistry. Lower vibrio CFU counts were observed in the fully protected area of California Reef. Metagenome analysis showed that the unprotected reefs had a higher abundance of archaeal and viral sequences and more bacterial pathogens, while the protected reefs had a higher abundance of genes related to photosynthesis. Similar to other reef systems in the world, there was evidence that reductions in the biomass of herbivorous fishes and the consequent increase in macroalgal cover in the Abrolhos Bank may be affecting microbial diversity and abundance. Through the integration of different types of ecological data, the present study showed that protection from fishing may lead to greater reef health. The data presented herein suggest that protected coral reefs have higher microbial diversity, with the most degraded reef (Sebastia&otilde Gomes) showing a marked reduction in microbial species richness. It is concluded that ecological conditions in unprotected reefs may promote the growth and rapid evolution of opportunistic microbial pathogens.

54 ENVIRONMENTAL SCIENCES↗

Test Problem: Tilted Rayleigh-Taylor for 2-D Mixing Studies

The 'tilted-rig' test problem originates from a series of experiments (Smeeton & Youngs, 1987, Youngs, 1989) performed at AWE in the late 1980's, that followed from the 'rocket-rig' experiments (Burrows et al., 1984; Read & Youngs, 1983), and exploratory experiments performed at Imperial College (Andrews, 1986; Andrews and Spalding, 1990). A schematic of the experiment is shown in Figure 1, and comprises a tank filled with light fluid above heavy, and then 'tilted' on one side of the apparatus, thus causing an 'angled interface' to the acceleration history due to rockets. Details of the configuration given in the next chapter include: fluids, dimensions, and other necessary details to simulate the experiment. Figure 2 shows results from two experiments, Case 110 (which is the source for this test problem) that has an Atwood number of 0.5, and Case 115 (a secondary source described in Appendix B), with Atwood of 0.9 Inspection of the photograph in Figure 2 (the main experimental diagnostic) for Case 110. reveals two main areas for mix development; 1) a large-scale overturning motion that produces a rising plume (spike) on the left, and falling plume (bubble) on the right, that are almost symmetric; and 2) a Rayleigh-Taylor driven mixing central mixing region that has a large-scale rotation associated with the rising and falling plumes, and also experiences lateral strain due to stretching of the interface by the plumes, and shear across the interface due to upper fluid moving downward and to the right, and lower fluid moving upward and to the left. Case 115 is similar but differs by a much larger Atwood of 0.9 that drives a strong asymmetry between a left side heavy spike penetration and a right side light bubble penetration. Case 110 is chosen as the source for the present test problem as the fluids have low surface tension (unlike Case 115) due the addition of a surfactant, the asymmetry small (no need to have fine grids for the spike), and there is extensive reasonable quality photographic data. The photographs in Figure 2 also reveal the appearance of a boundary layer at the left and right walls; this boundary layer has not been included in the test problem as preliminary calculations suggested it had a negligible effect on plume penetration and RT mixing. The significance of this test problem is that, unlike planar RT experiments such as the Rocket-Rig (Youngs, 1984), Linear Electric Motor - LEM (Dimonte, 1990), or the Water Tunnel (Andrews, 1992), the Tilted-Rig is a unique two-dimensional RT mixing experiment that has experimental data and now (in this TP) Direct Numerical Simulation data from Livescu and Wei. The availability of DNS data for the tilted-rig has made this TP viable as it provides detailed results for comparison purposes. The purpose of the test problem is to provide 3D simulation results, validated by comparison with experiment, which can be used for the development and validation of 2D RANS models. When such models are applied to 2D flows, various physics issues are raised such as double counting, combined buoyancy and shear, and 2-D strain, which have not yet been adequately addressed. The current objective of the test problem is to compare key results, which are needed for RANS model validation, obtained from high-Reynolds number DNS, high-resolution ILES or LES with explicit sub-grid-scale models. The experiment is incompressible and so is directly suitable for algorithms that are designed for incompressible flows (e.g. pressure correction algorithms with multi-grid); however, we have extended the TP so that compressible algorithms, run at low Mach number, may also be used if careful consideration is given to initial pressure fields. Thus, this TP serves as a useful tool for incompressible and compressible simulation codes, and mathematical models. In the remainder of this TP we provide a detailed specification; the next section provides the underlying assumptions for the TP, fluids, geometry details, boundary conditions (and alternative set-ups), initial conditions, and acceleration history (and ways to treat the acceleration ramp at the start of the experiment). This is followed by a section that defines data to be collected from the simulations, with results from the experiments and DNS from Livescu using the CFDNS code, and ILES simulations from Youngs using the compressible TURMOIL code and Andrews using the incompressible RTI3D code. We close the TP with concluding remarks, and Appendices that includes details of the sister Case 115, initial condition specifications for density and pressure fields. The Tilted-Rig Test Problem is intended to serve as a validation problem for RANS models, and as such we have provided ILES and DNS simulations in support of the test problem definition. The generally good agreement between experiment, ILES and DNS supports our assertion that the Tilted-Rig is useful, and the only 2-D TP that can be used to validate RANS models.

33 ADVANCED PROPULSION SYSTEMS↗

Concurrent Chemoradiotherapy With 5-Fluorouracil and Mitomycin C for Invasive Anal Carcinoma in Human Immunodeficiency Virus-Positive Patients Receiving Highly Active Antiretroviral Therapy

Purpose: To report the clinical outcomes of chemoradiotherapy (CRT) for anal carcinoma in human immunodeficiency virus (HIV)-infected patients receiving highly active antiretroviral therapy. Patients and Methods: Between 1997 and 2008, 21 HIV-positive patients who were receiving highly active antiretroviral therapy were treated with CRT (50.4 Gy at 1.8 Gy/fraction plus a 5.4-10.8-Gy external boost; 5-fluorouracil, 1,000 mg/m{sup 2}, Days 1-4 and 29-32; and mitomycin C, 10 mg/m{sup 2}, Days 1 and 29). A retrospective analysis was performed with respect to the tumor response, local control, cancer-specific and overall survival, and toxicity. The immunologic parameters, including pre- and post-treatment CD4 count, viral load, and acquired immunodeficiency syndrome-specific morbidity was recorded during follow-up (median, 53 months; range, 10-99). Results: CRT could be completed in all 21 patients with a reduction in the chemotherapy dose and/or interruption of radiotherapy in 5 and 5 cases, respectively. Acute Grade 3 toxicity occurred in 8 (38%) of the 21 patients. A complete response was achieved in 17 patients (81%), and tumor persistence or early progression was noted in 4 (19%). Six patients (29%) died, 5 of cancer progression and 1 of treatment-related toxicity. The 5-year local control, cancer-specific, and overall survival rate was 59%, 75%, and 67%, respectively. The median CD4 count significantly decreased from 347.5 cells/muL before CRT to 125 cells/muL 3-7 weeks after CRT completion (p <.001). In 6 (32%) of 19 patients, an increase of the HIV viral load was noted. Both parameters returned to the pretreatment values with additional follow-up. Conclusion: Our data have confirmed that in the highly active antiretroviral therapy era, HIV-related anal cancer can be treated with standard CRT without dose reductions. Close surveillance of the immunologic parameters is necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of pulse shape discrimination performance of stilbene and liquid scintillator under high count-rate active interrogation conditions

Here, we compare the pulse-shape-discrimination performance of a large Stilbene detector, manufactured at the Lawrence Livermore National Laboratory, to a similarly sized liquid scintillator, made by Eljen Technologies, Inc. (type EJ309), under various high-count-rate scenarios, such as can be expected during Active Interrogation of objects using an electric neutron generator for detecting the presence of Special Nuclear Materials and contraband. Pulse Shape Discrimination (PSD) is performed with an extension of previously described wavelet and event fitting algorithms, which are also used to reject pileup events and to correct the energy calibration for event signals clipped during digitization. We find that strong PSD and pileup rejection cuts are required to function in this high-count-rate environment. Whereas the Stilbene detector has intrinsically better pulse-shape discrimination performance, the pulses of events from the liquid scintillator are somewhat narrower, reducing pileup. We use an event fitting cut that provides simultaneous PSD identification and pileup rejection. When applying the same cut to data taken with both detectors, we find that Stilbene has higher event use efficiency by about a factor of two and retains a better gamma rejection ratio compared to EJ309.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RX J1301.9+2747: A HIGHLY VARIABLE SEYFERT GALAXY WITH EXTREMELY SOFT X-RAY EMISSION

In this paper we present a temporal and spectral analysis of X-ray data from XMM-Newton and Chandra observations of the ultrasoft and variable Seyfert galaxy RX J1301.9+2747. In both observations the source clearly displays two distinct states in the X-ray band: a long quiescent state and a short flare (or eruptive) state which differs in count rates by a factor of 5-7. The transition from the quiescent to the flare state occurs in 1-2 ks. We have observed that the quiescent state spectrum is unprecedentedly steep with a photon index {Gamma} {approx} 7.1, and the spectrum of the flare state is flatter with {Gamma} {approx} 4.4. X-rays above 2 keV were not significantly detected in either state. In the quiescent state, the spectrum appears to be dominated by a blackbody component of temperature about {approx}30-40 eV, which is comparable to the expected maximum effective temperature from the inner accretion disk. The quiescent state, however, requires an additional steep power law, presumably arising from Comptonization by transient heated electrons. The optical spectrum from the Sloan Digital Sky Survey shows Seyfert-like narrow lines for RX J1301.9+2747, while Hubble Space Telescope imaging reveals a central point source for the object. In order to precisely determine the hard X-ray component, future longer X-ray observations are required. This will help constrain the accretion disk model for RX J1301.9+2747, and shed new light on the characteristics of the corona and accretion flows around black holes.

79 ASTRONOMY AND ASTROPHYSICS↗

Genotyping‐in‐Thousands by sequencing (GT‐seq): A cost effective SNP genotyping method based on custom amplicon sequencing

Abstract Genotyping‐in‐Thousands by sequencing ( GT ‐seq) is a method that uses next‐generation sequencing of multiplexed PCR products to generate genotypes from relatively small panels (50–500) of targeted single‐nucleotide polymorphisms ( SNP s) for thousands of individuals in a single Illumina HiSeq lane. This method uses only unlabelled oligos and PCR master mix in two thermal cycling steps for amplification of targeted SNP loci. During this process, sequencing adapters and dual barcode sequence tags are incorporated into the amplicons enabling thousands of individuals to be pooled into a single sequencing library. Post sequencing, reads from individual samples are split into individual files using their unique combination of barcode sequences. Genotyping is performed with a simple perl script which counts amplicon‐specific sequences for each allele, and allele ratios are used to determine the genotypes. We demonstrate this technique by genotyping 2068 individual steelhead trout ( Oncorhynchus mykiss ) samples with a set of 192 SNP markers in a single library sequenced in a single Illumina HiSeq lane. Genotype data were 99.9% concordant to previously collected TaqMan ™ genotypes at the same 192 loci, but call rates were slightly lower with GT ‐seq (96.4%) relative to Taqman (99.0%). Of the 192 SNP s, 187 were genotyped in ≥90% of the individual samples and only 3 SNP s were genotyped in <70% of samples. This study demonstrates amplicon sequencing with GT ‐seq greatly reduces the cost of genotyping hundreds of targeted SNP s relative to existing methods by utilizing a simple library preparation method and massive efficiency of scale.

Campbell, Nathan R.↗

The Integration of Wi-Fi Location-Based Services to Optimize Energy Efficient Commercial Building Operations

This project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at commercial buildings located in Saint Paul, MN; Madison, WI; New York City; and Fort Worth, TX.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computer vision-based rock bolt detection in orthomosaic imagery obtained in the Waste Isolation Pilot Plant underground facility

Assessing structural integrity of large underground tunnel facilities is often a time consuming and human-labor intensive task. Thus, research using various modes of sensing and automated detection of key structural components in mines is posed to aid in safety assessments and establishing overall structural health. We propose an approach utilizing off-the-shelf camera and lidar technology fixed to a custom sensing platform, image stitching techniques, fine-tuned object detection models, and specialized model-inference methods to automatically detect, count, and map roof bolts for assessment of structural safety in man-made underground tunnels. Results show a novel workflow for effective object counting in orthomosaic tunnel ceiling images generated from collections in GPS-denied mining environments. Additionally, we demonstrate effective fine-tuning of EfficientDet object detectors utilizing state-of-the-art image augmentation techniques known as the mosaic and mixup transformations. Our work is demonstrated on sensed data and imagery collected from the Department of Energy (DOE) Waste Isolation Pilot Plant (WIPP) where miles of tunnel ceiling must be assessed for structural integrity.

42 ENGINEERING↗

Allometric and Mobile Terrestrial LiDAR Modeling of Aboveground Woody Biomass of Populus in Coppice Production

Poplars ( Populus spp.) and their hybrids are increasingly being grown in coppice production to generate bioenergy feedstocks at frequent intervals. Allometric equations are re-quired to predict aboveground biomass (AGB) of coppiced individuals with minimal field measurements. Likewise, remote sensing tools like LiDAR (light detection and ranging) can be used if models are available to predict AGB from point cloud data. Therefore, this study sought to develop equations to predict dry woody AGB from field measurements and LiDAR data from coppiced poplar field trials containing eastern cottonwood ( P. del-toides ) and hybrid poplar taxa. We found that taxa-specific allometric models containing the summed basal area of the three largest stems in the coppice provided the best predictive model, with stem height and stem count failing to provide additional explanatory power. The best predictive LiDAR-based model was independent of taxa but had slightly lower adjusted R 2 and higher RMSE than the allometric model. It contained four parameters including crown volume, leaf area index, variance of height returns, and the top point density (i.e., density metric 9 or the proportion of points in the highest point interval when the point cloud is evenly divided into ten vertical intervals). In total, these models can be used to quickly and efficiently estimate dry woody AGB of Populus coppice systems for bioenergy feedstock production.

AGB↗