Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Wide-Field Imaging Interferometry Spatial-Spectral Image Synthesis Algorithms

Developed is an algorithmic approach for wide field of view interferometric spatial-spectral image synthesis. The data collected from the interferometer consists of a set of double-Fourier image data cubes, one cube per baseline. These cubes are each three-dimensional consisting of arrays of two-dimensional detector counts versus delay line position. For each baseline a moving delay line allows collection of a large set of interferograms over the 2D wide field detector grid; one sampled interferogram per detector pixel per baseline. This aggregate set of interferograms, is algorithmically processed to construct a single spatial-spectral cube with angular resolution approaching the ratio of the wavelength to longest baseline. The wide field imaging is accomplished by insuring that the range of motion of the delay line encompasses the zero optical path difference fringe for each detector pixel in the desired field-of-view. Each baseline cube is incoherent relative to all other baseline cubes and thus has only phase information relative to itself. This lost phase information is recovered by having point, or otherwise known, sources within the field-of-view. The reference source phase is known and utilized as a constraint to recover the coherent phase relation between the baseline cubes and is key to the image synthesis. Described will be the mathematical formalism, with phase referencing and results will be shown using data collected from NASA/GSFC Wide-Field Imaging Interferometry Testbed (WIIT).

Lyon, Richard G.↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗

Sperm quality biomarkers complement reproductive and endocrine parameters in investigating environmental contaminants in common carp (Cyprinus carpio) from the Lake Mead National Recreation Area

Highlights: • Reproductive and endocrine biomarkers were differentially altered in carp in Lake Mead National Recreational Area. • Sex steroid hormone, sperm motility, and vitellogenin biomarker data pointed to lessened endocrine disrupting effects in 2006 versus late 1990's. • Among sub-basins, fish in Gregg Basin were least affected by endocrine disrupting compounds. • Compounds indicating risks in LMNRA included galaxolide, methyl triclosan, polybrominated diphenyl ether-47, hexachlorobenzene, and polychlorinated biphenyls. • Male germplasm provides pertinent cell and molecular biomarkers for endocrine disrupting compound studies. Lake Mead National Recreational Area (LMNRA) serves as critical habitat for several federally listed species and supplies water for municipal, domestic, and agricultural use in the Southwestern U.S. Contaminant sources and concentrations vary among the sub-basins within LMNRA. To investigate whether exposure to environmental contaminants is associated with alterations in male common carp (Cyprinus carpio) gamete quality and endocrine- and reproductive parameters, data were collected among sub-basins over 7 years (1999–2006). Endpoints included sperm quality parameters of motility, viability, mitochondrial membrane potential, count, morphology, and DNA fragmentation; plasma components were vitellogenin (VTG), 17ß-estradiol, 11-keto-testosterone, triiodothyronine, and thyroxine. Fish condition factor, gonadosomatic index, and gonadal histology parameters were also measured. Diminished biomarker effects were noted in 2006, and sub-basin differences were indicated by the irregular occurrences of contaminants and by several associations between chemicals (e.g., polychlorinated biphenyls, hexachlorobenzene, galaxolide, and methyl triclosan) and biomarkers (e.g., plasma thyroxine, sperm motility and DNA fragmentation). By 2006, sex steroid hormone and VTG levels decreased with subsequent reduced endocrine disrupting effects. The sperm quality bioassays developed and applied with carp complemented endocrine and reproductive data, and can be adapted for use with other species.

54 ENVIRONMENTAL SCIENCES↗

Machine Learning Application in Aircraft Engine Conceptual Design

In the current competitive environment, the successful creation and application of machine learning (ML) technologies have become crucial across multiple industries. This study outlines the process of creating and implementing ML models for conceptualizing and evaluating aircraft engines. These models use supervised deep-learning algorithms to analyze patterns within an open-source repository containing data on both production and research conventional turbofan engines. Key focus areas include crucial engine parameters such as thrust-specific fuel consumption (TSFC), engine weight, engine diameter, and turbomachinery stage counts. While developing ML models is fundamental, ensuring their seamless deployment is equally important. To address this, a conversational AI chatbot is constructed using natural language processing (NLP) techniques to facilitate the deployment of these ML models. The comprehensive workflow includes several key stages: gathering and enhancing engine data, training and cross validating the ML models, testing and evaluating their performance, and finally, deploying, monitoring, and updating the ML models. By following this systematic approach, the aim is to streamline the development and deployment process of ML models tailored for aircraft engine conceptual design.

Aircraft Engine↗

Counting Calories: Light Yield Studies for ADRIANO Calorimeter Prototype

To estimate the light yield for ADRIANO prototype, we must calibrate the light sensors as well as collect data from beams of known properties. Future experiments searching for new physics require special calorimetric techniques to detect new particles. ADRIANO2(A Dual Readout Integrally Active Non-segmented Option) is one such technique. Several prototypes have been tested at Mtest Facility at Fermi National Accelerator Laboratory in the last few years. This work consisting of new and more refined analysis of the data taken with the intent of improving the understanding of this calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Axial Asymmetry Studies in Gaia Data Release 2 Yield the Pattern Speed of the Galactic Bar

Our recent studies of axial-symmetry breaking in the nearby ($d <3 \,{\rm kpc}$) star counts are sensitive to the distortions of stellar orbits perpendicular and parallel to the orientation of the bar just within and beyond the outer Lindblad resonance (OLR) radius. Using the location of the sign flip in the left-right asymmetry in stars counts about the anticenter line to determine the OLR radius $R_{\rm OLR}$, and treating the bar as if it were a weakly non-axisymmetric effect, we use $R_{\rm OLR}$ and recent measurements of the Galactic rotation curve and the Sun-Galactic-center distance $R_{0}$ to determine the pattern speed $\Omega_{\rm p}$ of the Galactic bar, as well as the Galactic corotation radius $R_{\rm CR}$. After removing the effect of the Large and Small Magellanic clouds from our asymmetry measurement, we find that $R_{\rm OLR}=(0.96 \pm 0.03)R_0 = 7.85 \pm 0.25 \ \rm kpc$, $\Omega_{\rm p} = 49.3 \pm 2.2 \ \rm km \ s^{-1} \ kpc^{-1}$, $R_{\rm CR}=(0.58 \pm 0.04)R_0 = 4.76 \pm 0.27 \ \rm kpc$, revealing, as we shall show, that the Milky Way's bar is likely both weak and fast, though we also note possible evidence for non-steady-state effects in the bar region.

79 ASTRONOMY AND ASTROPHYSICS↗

Low Count and Background Radionuclides Analysis - 20488

The US Department of Energy (DOE) is often faced with the need to evaluate radionuclides at low concentrations. When site sample data are likely to be close to threshold activity concentrations of interest, then the means by which the radiochemical analysis is performed and reported is critical. This situation can occur when differentiating from zero (presence/absence) for radionuclides that do not occur naturally, close comparison with environmental background for naturally occurring radionuclides, close comparison with a risk- or dose-based threshold concentrations of interest, or even comparisons across studies. There are several analytical issues that are of concern, but the two that appear to cause incorrect decisions to be made most often involve establishing detection limits and subtracting ambient background conditions in the laboratory. These issues are not critical when radionuclide activity concentrations are large relative to thresholds of concern, but they seem to be poorly understood when it matters. When the comparisons are important and are likely to be close to a threshold of interest, then the general contract with the analytical laboratories needs to be changed so that the right or appropriate data are obtained. The concern is that important decisions are made incorrectly more often as greater scrutiny is placed on DoE's radionuclide cleanup or monitoring decisions by the public and other stakeholders. Examples are presented of problems that have been observed for different projects, both within and outside the realm of DOE and NRC remediation and radioactive waste disposal problems, and solutions are offered that should lead to better data from which important decisions need to be made. The first example is from Los Alamos National Laboratory (LANL) and involves radionuclide concentrations in soil and rock beneath LANL's Material Disposal Area (MDA) G. An initial review of the data led to a conclusion that americium and plutonium are a long way present beneath MDA G. A more thorough review of the data that accounted properly for ambient background and the detection limits that had been established led to the opposite conclusion. Another example is from the Nevada National Security Site where tritium results from one of the wells were unexpectedly high. Proper understanding and analysis of ambient background led to the conclusion that the increased concentrations were not so obvious, and that a different contract with the analytical laboratory was needed to provide more appropriate data to support a better determination. Other examples are used from regulatory review of projects in Nevada, where background levels and secular equilibrium for naturally occurring radionuclides are not established correctly because of analytical issues. The same basic issues have also been found to create difficulties analyzing historical data from the West Valley Demonstration Project. There is evidence in the data that the apparent lack of secular equilibrium where it is expected to exist is related to ambient background subtraction or other analytical issues. A final example is presented for analysis of Tc-99 in samples of depleted uranium. In this case, two different studies that were performed only three months apart provide quite different results. The US Environmental Protection Agency (EPA) established the data quality objectives (DQO) process in the mid-1980's to establish decision performance criteria for data collection. EPA guidance (EPA G-4, for example) clearly distinguishes between DQOs and measurement performance objectives (MQOs) that should be addressed for laboratory analysis of samples. The language of DQOs and MQOs has become confused over time it seems, and the subsequent effects seem to include a lack of attention to decision performance and a routine approach to measurement quality. In order to better address radionuclide sample analysis when the concentrations are close to thresholds of concern, which might be zero for some radionuclides, background for others, and risk-based thresholds for yet others, it is important that routine laboratory analysis methods are adjusted, and that the project team and the laboratory work closely together to ensure that the data meets the MQO requirements of laboratory analysis and reporting of results, and that the MQOs effectively support project-specific DQOs. This basic approach will be applied in Los Alamos in the coming year to the collection of moisture data from underneath MDA T that will be analyzed for americium and neptunium isotopes. Proper understanding of the radiochemistry methods and reporting, and of appropriate statistical methods is critical to the success of such projects, ensuring that the right decisions are made. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Walk on Floor Eyes Closed Test: A Unique Test of Spaceflight Induced Ataxia

Measurement and quantification of posture and locomotion following spaceflight is an evolving process. Based on the data obtained from the current investigation we believe that the walk on the floor line test with the eyes closed (WOFEC) provides a unique procedure for quantifying postflight ataxia. As a part of an ongoing investigation designed to look at functional changes in astronauts returning from spaceflight seven astronauts (5 short duration with flights of 12-16 days; 2 long duration crewmembers with flights of 6 months) were tested twice before flight, on landing day (short duration only), and 1, 6, and 30 days after flight. The WOFEC consisted of walking for 10 steps (repeated twice) with the feet heel to toe in tandem, arms folded across the chest and the eyes closed. The performance metric (scored by three examiners from video) was the percentage of correct steps completed over the three trials. A step was not counted as correct if the crewmember side-stepped, opened their eyes, or paused for more than three seconds between steps. The data reveled a significant decrease in percentage of correct steps on landing day (short duration crew) and on the first day following landing (long duration) with partial recovery the following day, and full recovery beginning on day sixth after flight. Both short and long duration fliers appeared to be unaware of foot position relative to their bodies or the floor. Postflight, deviation from a straight path was common, and seemed to be determined by the angle of foot placement relative to their body. While deviation from a straight line could be either left or right, primary deviations were observed to occur to the right. Furthermore, the test for two crewmembers elicited motion sickness symptoms. These data clearly demonstrate the sensorimotor challenges facing crewmembers after returning from spaceflight. The WOFEC test has value providing the investigator or crew surgeon with a simple method to quantify vestibular ataxia, as well as providing instant feedback of postural ataxia without the use of complex test equipment.

Reschke, M. F.↗

Microphysical properties of the Shuttle exhaust cloud

A data base describing the properties of the exhaust cloud produced by the launch of the STS has been developed based on data from a series of ground and aircraft based measurements made during the launches of STS 2, 3, and 4. Aircraft observations were performed during the STS-3 launch with a NOAA WP-3D Orion hurricane research aircraft which contained instrumentation for cloud condensation nucleus and ice nucleus counting, Aitken particle counting, and pH determination. Ground observations were conducted at 50 different sites, as well as in the direct exhaust from the solid rocket booster flame trench at all three launches. The data is analyzed in order to determine any possible adverse impacts of the exhaust products on human health and/or the environment. Analyses of the exhaust cloud measurements indicate that in the case of the ground cloud where plenty of large water drops are present and considerable scavenging and fallout of aerosol takes place, possible adverse impacts of the remaining aerosols (CCN and IN) on natural precipitation processes which may occur in the launch area hours after the launch are remote. However, it is determined that under certain atmospheric conditions there could be short term adverse effects on visibility.

Keller, V. W.↗

A petabyte size electronic library using the N-Gram memory engine

A model library containing petabytes of data is proposed by Triada, Ltd., Ann Arbor, Michigan. The library uses the newly patented N-Gram Memory Engine (Neurex), for storage, compression, and retrieval. Neurex splits data into two parts: a hierarchical network of associative memories that store 'information' from data and a permutation operator that preserves sequence. Neurex is expected to offer four advantages in mass storage systems. Neurex representations are dense, fully reversible, hence less expensive to store. Neurex becomes exponentially more stable with increasing data flow; thus its contents and the inverting algorithm may be mass produced for low cost distribution. Only a small permutation operator would be recalled from the library to recover data. Neurex may be enhanced to recall patterns using a partial pattern. Neurex nodes are measures of their pattern. Researchers might use nodes in statistical models to avoid costly sorting and counting procedures. Neurex subsumes a theory of learning and memory that the author believes extends information theory. Its first axiom is a symmetry principle: learning creates memory and memory evidences learning. The theory treats an information store that evolves from a null state to stationarity. A Neurex extracts information data without a priori knowledge; i.e., unlike neural networks, neither feedback nor training is required. The model consists of an energetically conservative field of uniformly distributed events with variable spatial and temporal scale, and an observer walking randomly through this field. A bank of band limited transducers (an 'eye'), each transducer in a bank being tuned to a sub-band, outputs signals upon registering events. Output signals are 'observed' by another transducer bank (a mid-brain), except the band limit of the second bank is narrower than the band limit of the first bank. The banks are arrayed as n 'levels' or 'time domains, td.' The banks are the hierarchical network (a cortex) and transducers are (associative) memories. A model Neurex was built and studied. Data were 50 MB to 10 GB samples of text, data base, and images: black/white, grey scale, and high resolution in several spectral bands. Memories at td, S(m(sub td)), were plotted against outputs of memories at td-1. S(m(sub td)) was Boltzman distributed, and memory frequencies exhibited self-organized criticality (SOC); i.e., 'l/f(sup beta)' after long exposures to data. Whereas output signals from level n may be encoded with B(sub output) = O(-log(2)f(sup beta)) bits, and input data encoded with B(sub input) = O((S(td)/S(td-1))(sup n)), B(sup output)/B(sub input) is much less than 1 always, the Neurex determines a canonical code for data and it is a lossless data compressor. Further tests are underway to confirm these results with more data types and larger samples.

Bugajski, Joseph M.↗

Study of the Few Nucleon Systems at $\mathrm{CLAS}$

The study of few nucleon systems with electromagnetic probes is an essential component of the scientific program carried out at the Thomas Jefferson National Accelerator Facility (JLab). Here we present measurements of exclusive reactions on light nuclei using real photon beams with energies up to 3 GeV and the CEBAF Large Acceptance Spectrometer (CLAS), a nearly 4π magnetic spectrometer, in order to study the properties of strongly interacting matter and the transition from hadronic (i.e in terms of nucleons and mesons) to partonic (in terms of quark and gluons) degrees of freedom in nuclear interactions. We discuss the progress made in understanding the relevant degrees of freedom using polarisation observables and cross sections of deuteron and 3 He photodisintegration in the few-GeV photon-energy region. In addition, recent high-statistics experiments with the CLAS detector have provided us with sufficient counting rates to study the effects of initial- and final-state interactions in reactions off the deuteron. Such data allow us to extract a large set of polarisation observables for final-state interactions in hyperon photoproduction and to study the properties of the hyperon–nucleon interaction. Initial-state effects are studied by mapping the dependence of experimental observables on the spectator-nucleon momentum. We also present recent results for polarisation observables for quasi-free K + Λ off the bound proton in a deuteron as well as for final-state interactions in the reaction γd→K + Λn , and will discuss their impact on hyperon–nucleon studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A wearable sensor based on CLYC scintillators

We developed a wearable radiation sensor using Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous gamma-ray and neutron detection. The system includes two ø2.5×2.5 cm 3 crystals coupled to small, metal-body photomultiplier tubes. A custom, low-power electronics base digitizes the output signal at three time points and enables both pulse height and pulse shape discrimination of neutrons and gamma-rays. Data, including spectra, can be transferred via a wired or wireless connection. The total gamma-ray and neutron counts, anomaly detection metrics, and identified isotopes are displayed on a small screen on the device. Users may leave the system in unattended mode to collect long-dwell energy spectra. The prototype system has overall dimensions of 13×7.5×18 cm 3 and weight of 1.3 kg, not including the protective pouch, and runs on six AA alkaline batteries for 29 hours with a 1% wireless transmission duty cycle and 41 hours with the wireless turned off . In this paper, we summarize the system design and present characterization results from the detector modules. The energy resolution is about 6.5% full width at half maximum at 662 keV due to the small photomultiplier tube selected, and the linearity and pulse shape discrimination performance are very good.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CsI calorimeter for the J-PARC KOTO experiment

An electromagnetic calorimeter made of undoped CsI crystals is used in the J-PARC KOTO experiment to search for new physics beyond the standard model with the KL → π 0 νν¯ decay. The calorimeter is designed to operate in vacuum of 0.1 Pa and in a high-rate environment where the counting rate due to KL decays is O(100) kHz. A special method to calibrate the calorimeter during the data taking without using a tracking system for charged particles is reported. The energy, position, and timing resolutions of the calorimeter were evaluated in several beam tests, and the resolutions satisfy the required performance. Finally, the energy resolution with the total energy E is 0.66 ⊕ 1.81/ √ E[GeV]% in the inner region of the calorimeter.

47 OTHER INSTRUMENTATION↗

ULTRAVIOLET OBSERVATIONS OF THE GLOBULAR CLUSTER M10 FROM HST AND GALEX: THE BSS POPULATION

We present a combination of high-resolution Hubble Space Telescope and wide-field ground-based and Galaxy Evolution Explorer data of the Galactic globular cluster M10 (NGC 6254). By using this large data set, we determined the center of gravity of the cluster and we built its density profile from star counts over its entire radial extension. We find that the density profile is well reproduced by a single-mass King model with structural parameters c = 1.41 and r{sub c} = 41''. We also studied the blue straggler star (BSS) population and its radial distribution. We count a total number of 120 BSS within the tidal radius. Their radial distribution is bimodal: highly peaked in the cluster center, decreasing at intermediate distances, and rising again outward. We discuss these results in the context of the dynamical clock scheme presented by Ferraro et al. and of recent results about the radial distribution of binary systems in this cluster.

79 ASTRONOMY AND ASTROPHYSICS↗

Small animal simultaneous PET/MRI: initial experiences in a 9.4T microMRI

We developed a non-magnetic positron-emission tomography (PET) device based on the rat conscious animal PET that operates in a small-animal magnetic resonance imaging (MRI) scanner, thereby enabling us to carry out simultaneous PET/MRI studies. The PET detector comprises 12 detector blocks, each being a 4 x 8 array of lutetium oxyorthosilicate crystals (2.22 x 2.22 x 5 mm{sup 3}) coupled to a matching non-magnetic avalanche photodiode array. The detector blocks, housed in a plastic case, form a 38 mm inner diameter ring with an 18 mm axial extent. Custom-built MRI coils fit inside the positron-emission tomography (PET) device, operating in transceiver mode. The PET insert is integrated with a Bruker 9.4 T 210 mm clear-bore diameter MRI scanner. We acquired simultaneous PET/MR images of phantoms, of in vivo rat brain, and of cardiac-gated mouse heart using [{sup 11}C]raclopride and 2-deoxy-2-[{sup 18}F]fluoro-d-glucose PET radiotracers. There was minor interference between the PET electronics and the MRI during simultaneous operation, and small effects on the signal-to-noise ratio in the MR images in the presence of the PET, but no noticeable visual artifacts. Gradient echo and high-duty-cycle spin echo radio frequency (RF) pulses resulted in a 7% and a 28% loss in PET counts, respectively, due to high PET counts during the RF pulses that had to be gated out. The calibration of the activity concentration of PET data during MR pulsing is reproducible within less than 6%. Our initial results demonstrate the feasibility of performing simultaneous PET and MRI studies in adult rats and mice using the same PET insert in a small-bore 9.4 T MRI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-pion-exchange and other higher-order contributions to the pp{yields}pp{pi}{sup 0} reaction

Much effort has been invested on effective-field-theoretical studies of the near-threshold NN{yields}NN{pi} reactions and, in order to deal with the somewhat large three-momentum transfers involved, the momentum counting scheme (MCS) was proposed as an alternative to the usual Weinberg counting scheme. Given the fact that a quantitative explanation of the existing high-precision NN{yields}NN{pi} data requires a careful examination of higher chiral order contributions to the transition operator, we make a detailed numerical investigation of the convergence property of MCS for a pilot case of the pp{yields}pp{pi}{sup 0} reaction. Our study indicates that MCS is superior to the Weinberg scheme in identifying dominant higher order contributions to the NN{yields}NN{pi} reactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accurate U 238 ( n , 2 n ) U 237 reaction cross-section measurements from 6.5 to 14.8 MeV

In this study, the cross section for the 238 U(n,2n) 237 U reaction has been measured in the incident neutron energy range from 6.5 to 14.8 MeV in small energy steps using an activation technique. Monoenergetic neutron beams were produced via the 2 H( d,n ) 3 He and 3 H ( d,n ) 4 He reactions. 238 U targets were activated along with Au and Al monitor foils to determine the incident neutron flux. The activity of the reaction products was measured in TUNL's low-background counting facility using high-resolution γ-ray spectroscopy. The results are compared with previous measurements and latest data evaluations. Statistical-model calculations, based on the Hauser-Feshbach formalism, have been carried out using the CoH 3 code and are compared with the experimental results. Finally, the present self-consistent and high-quality data are important for stockpile stewardship and nuclear forensic purposes as well as for the design and operation of fast reactors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Linear diffraction grating interferometer with high alignment tolerance and high accuracy

We present an innovative structure of a linear diffraction grating interferometer as a long stroke and nanometer resolution displacement sensor for any linear stage. The principle of this diffractive interferometer is based on the phase information encoded by the {+-}1st order beams diffracted by a holographic grating. Properly interfering these two beams leads to modulation similar to a Doppler frequency shift that can be translated to displacement measurements via phase decoding. A self-compensation structure is developed to improve the alignment tolerance. LightTool analysis shows that this new structure is completely immune to alignment errors of offset, standoff, yaw, and roll. The tolerance of the pitch is also acceptable for most installation conditions. In order to compact the structure and improve the signal quality, a new optical bonding technology by mechanical fixture is presented so that the miniature optics can be permanently bonded together without an air gap in between. For the output waveform signals, a software module is developed for fast real-time pulse counting and phase subdivision. A laser interferometer HP5529A is employed to test the repeatability of the whole system. Experimental data show that within 15 mm travel length, the repeatability is within 15 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗