Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X-ray system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Hard X-ray observations of fast pulsars from HEAO-1

A favorable combination of sensitive area and viewing time for the UCSD/MIT Hard X-Ray and Gamma-Ray Telescope on satellite HEAO-1 permitted significant contributions to the study of binary systems. Results are reviewed for five fast pulsars: Her X-1, 4U0115+63, LMC X-4, SMC X-1 and Cen X-3.

Gruber, D. E.↗

Rye Canyon X-ray noise test: One-third octave-band data

Acoustic data were obtained for the 25 ft. diameter X-wing rotor model during performance testing of the rotor system in hover. Data collected at the outdoor whirl tower test facility with a twelve microphone array were taken for approximately 150 test conditions comprised of various combinations of RPM, blade pressure ratio (BPR), and blade angle of attack (collective). The three test parameters had four values of RPM from 404 to 497, twelve values of BPR from 1.0 to 2.1, and six values of collective from 0.0 deg to 8.5 deg. Fifteen to twenty seconds of acoustic data were reduced to obtain an average 1/3 octave band spectrum for each microphone for each test condition. The complete, as measured, 1/3 octave band results for all the acoustic data are listed. Another part of the X-wing noise test was the acoustic calibration of the Rye Canyon whirl tower bowl. Corrections were computed which, when applied to as measured data, yield estimates of the free field X-wing noise. The free field estimates provide a more realistic measure of the rotor system noise levels. Trend analysis of the three test parameters on noise level were performed.

Willshire, W. L., Jr.↗

Photon-counting array detectors for space and ground-based studies at ultraviolet and vacuum ultraviolet /VUV/ wavelengths

The Multi-Anode Microchannel Arrays (MAMAs) are a family of photoelectric photon-counting array detectors, with formats as large as (256 x 1024)-pixels that can be operated in a windowless configuration at vacuum ultraviolet (VUV) and soft X-ray wavelengths or in a sealed configuration at ultraviolet and visible wavelengths. This paper describes the construction and modes of operation of (1 x 1024)-pixel and (24 x 1024)-pixel MAMA detector systems that are being built and qualified for use in sounding-rocket spectrometers for solar and stellar observations at wavelengths below 1300 A. The performance characteristics of the MAMA detectors at ultraviolet and VUV wavelengths are also described.

Timothy, J. G.↗

Multi-anode microchannel arrays - New detectors for imaging and spectroscopy in space

Consideration is given to the construction and operation of multi-anode microchannel array detector systems having formats as large as 256 x 1024 pixels. Such arrays are being developed for imaging and spectroscopy at soft X-ray, ultraviolet and visible wavelengths from balloons, sounding rockets and space probes. Both discrete-anode and coincidence-anode arrays are described. Two types of photocathode structures are evaluated: an opaque photocathode deposited directly on the curved-channel MCP and an activated cathode deposited on a proximity-focused mesh. Future work will include sensitivity optimization in the different wavelength regions and the development of detector tubes with semitransparent proximity-focused photocathodes.

Timothy, J. G.↗

X Persei - Optical polarization variation on the 580 day binary-like period

Observations of periodicities in the optical polarization of the weak X-ray source X Persei are reported. Polarization was measured in the V band 400 times over the course of 356 nights during 1977-1982. The Q and U Stokes parameters derived from the measurements show a definite variability with a typical amplitude of 0.1%, which is strongest at periods greater than 100 days. In particular, a strong peak is observed with a period of 297 days, consistent with the second-harmonic component of the known 580-day radial velocity cycle. A component with 590-day periodicity is not ruled out by the observations, although it was not detected. Observations imply the 580-day period to be an effect of orbital or rotational processes, with the corotating scattering body either close to the light source or very large in extent, and a system inclination close to 80 deg.

Kemp, J. C.↗

Discovery of 13.5 s X-ray pulsations from LMC X-4 and an orbital determination

X-ray pulsations with a 13.5-sec period have been detected from the 1.4-d X-ray binary LMC X-4. By measuring the apparent pulse period at several binary orbital phases, and assuming the orbit to be nearly circular, the semimajor axis of the orbit is determined to be 30 + or - 5 ly-sec. This result, together with a revised orbital velocity amplitude of 37.9 + or - 2.4 km/sec, and other available information, suffice for the determination of the component masses of the binary system and the radius of the companion star. The mass of the neutron star is found to be 1.6 +1.0 -0.5 solar masses, while the mass, radius, and effective temperature of the companion star indicate that it may be undermassive for its luminosity.

Kelley, R. L.↗

Stellar contributions to the hard X-ray galactic ridge

The number density of serendipitous sources in galactic plane Einstein Observatory IPC fields are compared with predictions based on the intensity of the HEAO 1 A-2 unresolved hard X-ray galactic ridge emission. It is concluded that it is unlikely that X-ray sources with 2-10 keV luminosities from about 8 x 10 to the 32nd to about 3 x 10 to the 34th ergs/s are dominant contributors to the hard X-ray galactic ridge. Their surfacea density is less than about 8 x 10 to the -4th/L(32)/sq pc. In particular, Be/neutron star systems such as X Per are not expected to be dominant contributors, both because the 2-10 keV luminosity is roughly 10 to the 33rd ergs/s and their scale height is too small. Lower luminosity stellar systems are likely to be major contributors to the ridge. RS CVn and CV systems with 2-10 keV luminosities between 2 x 10 to the 30th and 4 x 10 to the 32nd ergs/s contribute about 43 + or 18 percent.

Worrall, D. M.↗

Constraints on the inclination and masses of the HDE 226868/Cygnus X-1 system from the observations

Analyses of two high-dispersions IUE spectra of HDE 226868 (the optical counterpart of Cygnus X-1) are combined with studies of low-dispersion IUE spectra to provide a more accurate determination of the variation of C IV stellar wind absorption as a function of orbital phase. By incorporating these observational results into an analysis of the structure of the X-ray ionization cavity in the stellar wind, it is found that the orbital inclination must lie between 36 and 67 deg, leading to a mass for the compact object between 5.7 and 11.2 solar masses.

Davis, R.↗

History, status and future applications of spaceborne cryogenic systems

Cryogenic cooling is employed for an increasing number of space instruments. Cryogenic cooling is needed to provide the required detector response, reduce preamplifier noise, and/or reduce background radiation. Cryogenic cooling is required by instruments employed for applications missions, gamma-ray and X-ray astronomy, cosmic ray measurements, space surveillance, IR astronomy, relativity measurements, superconductivity devices, and basic research experiments. The cooling is provided with the aid of radiant coolers, stored solid cryogen coolers, stored liquid-helium coolers, mechanical coolers, He-3 coolers, adiabatic demagnetization, refrigeration, and higher temperature adsorption and magnetic systems. Radiant coolers will continue to find widespread application for low cooling-load/high-temperature situation. It is pointed out that a long-lifetime closed-cycle, mechanical cooler is one of the most critical space technological needs.

Sherman, A.↗

High resolution X- and gamma-ray spectroscopy of solar flares

A balloon-borne X- and gamma-ray instrument was developed, fabricated, and flown. This instrument has the highest energy resolution of any instrument flown to date for measurements of solar and cosmic X-ray and gamma-ray emission in the 13 to 600 keV energy range. The purpose of the solar measurements was to study electron acceleration and solar flare energy release processes. The cosmic observations were to search for cyclotron line features from neutron stars and for low energy gamma-ray lines from nucleosynthesis. The instrument consists of four 4 cm diameter, 1.3 cm thick, planar intrinsic germanium detectors cooled by liquid nitrogen and surrounded by CsI and NaI anti-coincidence scintillation crystals. A graded z collimator limited the field of view to 3 deg x 6 deg and a gondola pointing system provided 0.3 deg pointing accuracy. A total of four flights were made with this instrument. Additional funding was obtained from NSF for the last three flights, which had primarily solar objectives. A detailed instrument description is given. The main scientific results and the data analysis are discussed. Current work and indications for future work are summarized. A bibliography of publications resulting from this work is given.

Lin, R. P.↗

The Advanced X-Ray Astrophysics Facility. Observing the Universe in X-Rays

An overview of the Advanced X ray Astronophysics Facility (AXAF) program is presented. Beginning with a brief introduction to X ray astrophysics, the AXAF observatory is described including the onboard instrumentation and system capabilities. Possible X ray sources suitable for AXAF observation are identified and defined.

Neal, V.↗

Nuclear Science Symposium, 30th, and Symposium on Nuclear Power Systems, 15th, San Francisco, CA, October 19-21, 1983, Proceedings

The range of disciplines covered includes physics instrumentation, data acquisition, FASTBUS, radiation detectors, scintillators, photomultipliers and optical detectors, subnanosecond 2-D imaging, medical and health instrumentation, reactor instrumentation, and space instrumentation. Cerenkov detectors, the prevention and rate capability of breakdown processes in wire chambers, and an interactive parallel processor for data analysis are studied. Attention is also given to bismuth germanate's role in gamma-ray spectroscopy, and the construction of a broadband universal sampling head is described. Gamma-ray imaging with a rotating hexagonal uniform redundant array, and broadband X-ray astronomical spectrometry are considered.

Nakamura, M.↗

Very long baseline interferometry observations of the RS Canum Venaticorum system HR 5110 at 8.4 GHz

The RS CVn binary system HR 5110 was observed with a well-calibrated four-element VLBI array at a frequency of 8.4 GHz. The total flux density, which was nearly constant at 32 + or - 2 mJy, was monitored throughout the experiment with a 20 km baseline interferometer allowing accurate visibilities to be calculated. The observed visibilities are consistent with a source unresolved on all the baselines. The maximum size of the equivalent Gaussian source is 1.4 milli-arcsec (FWHM), corresponding to a linear size of 1.1 x 10 to the 12th cm at 52 pc. This maximum size is comparable with the overall size of the binary system. The inferred lower limit of the brightness temperature is 4 x 10 to the 8th K, which is higher than the coronal temperature of 10 to the 7th K measured in a soft X-ray survey. This is consistent with a nonthermal mechanism for the radiation process of the moderate radio outburst observed.

Mutel, R. L.↗

High-resolution soft X-ray spectra of Scorpius X-1 - The structure of circumsource accreting material

Four observations of Scorpius X-1 with the Objective Grating Spectrometer of the Einstein Observatory have provided high-resolution spectra (lambda/Delta lambda = approximately 20-50) in the wavelength range 7-46 A. The spectra reveal the presence of absorption structure due to oxygen, nitrogen, and iron, and variable emission structure associated with ionized iron and nitrogen. The strengths of these features suggest that the N/O abundance ratio in the absorbing and line emitting gas is anomalously high, which might indicate that these spectral components are associated with processed material, probably accreting matter transferred from the surface of an evolved companion. Constraints on the inclination of the system, however, imply that this cool, dense, accreting material must be well out of the plane of the binary system. Possible models for the origin and nature of this circumsource medium are discussed. An extensive discussion of the calibration of the Objective Grating Spectrometer and of the analysis of spectra acquired by that instrument is also provided.

Kahn, S. M.↗

SMC X-1 variability observed from HEAO 1

Studies are reported of the slow variability of SMC X-1 and its spectrum. An analysis of red-noise random variability is based on a method discussed by Deeter and Boynton (1982). The 0.7 s X-ray pulsar SMC X-1 is in a 3.89 day eclipsing binary system with a B0 I supergiant companion. Observations of the pulsar were conducted with the aid of the UCSD/MIT instrument on HEAO 1 from 1977 August through 1979 January. A light curve was constructed for the period 1977 September to 1978 December. The apparent tendency of SMC X-1 to be in one of two states, high or low, suggests the acquisition of average spectra separately for each state. The total (steady plus pulsed) emission from SMC X-1 displays a continuum spectrum with a dominant exponential form which implies a temperature of 17 keV for thin thermal bremsstrahlung emission or 5 keV if the other limit of a Wien spectrum is assumed.

Gruber, D. E.↗

A spectroscopic study of LMC X-4

The orbital radial velocity semi-amplitude of the binary star system LMC X-4 primary was determined to be 37.9 + or - 2.4 km/s from measurements of the hydrogen absorption lines. The semi-amplitude of the He I and He II absorption lines are consistent with this, namely 44.9 + or - 5.0 and 37.3 + or - 5.3 km/s. The phase and shape of the radial velocity curves of the three ions are consistent with a circular orbit and an ephemeris based upon X-ray measurements of the neutron star, with the exception that the He II absorption line radial velocity curve has detectable shape distortion. Measurements of the He II LAMBOA 4686 emission line velocity are consistent with a phase shifted sine wave of semi-amplitude 535 km/s, a square wave of semi-amplitude 407 km/s, or high order harmonic fits. The spectral type was found to be 08.5 IV-V during X-ray eclipse. Variations to types as early as 07 occur, but not as a function or orbital phase. Absorption line peculiarities were noted on 6 of 58 spectra.

Petro, L. D.↗

Hercules X-1: Pulsed gamma-rays detected above 150 GeV

The 1.24 second binary pulsar Her X-1, first observed in X-rays in 1971 by UHURU has now been seen as a sporadic gamma ray source from 1 TeV up to at least 500 TeV. In addition, reprocessed optical and infrared pulses are seen from the companion star HZ Herculis. Thus measurements of the Her X-1/HZ Herculis system span 15 decades in energy, rivaling both the Crab pulsar and Cygnus X-3 in this respect for a discrete galactic source.

Cawley, M. F.↗

Homogeneous versus heterogeneous crystal nucleation in Li2O-2SiO2 glass

When analyzing crystal nucleation in glasses, it is difficult to distinguish between homogeneous and heterogeneous nucleation. A method is proposed to investigate the nature of crystal nucleation in Li2O-2SiO2, and calculations are performed to determine under which conditions saturation effects help ascertain the nature of the nucleation. The capability of detecting impurity particles in unheated glass via standard micrographic techniques (SEM or REM) and small angle X-ray scattering (SAXS) is explored. Results indicate that if the maximum impurity particle densities do not exceed 2 x 10 to the 7th per cu cm then heterogeneous nucleation may be excluded and most impurity particles with densities in excess of 10 to the 10th per cu cm are detectable by SAXS. It is concluded that crystal nucleation in this system most probably occurs homogeneously.

Weinberg, M. C.↗