Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing and Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

SU-F-T-313: Clinical Results of a New Customer Acceptance Test for Elekta VMAT

Purpose: To report the results of a customer acceptance test (CAT) for VMAT treatments for two matched Elekta linear accelerators. Methods: The CAT tests were performed on two clinically matched Elekta linear accelerators equipped with a 160-leaf MLC. Functional tests included performance checks of the control system during dynamic movements of the diaphragms, MLC, and gantry. Dosimetric tests included MLC picket fence tests at static and variable dose rates and a diaphragm alignment test, all performed using the on-board EPID. Additionally, beam symmetry during arc delivery was measured at the four cardinal angles for high and low dose rate modes using a 2D detector array. Results of the dosimetric tests were analyzed using the VMAT CAT analysis tool. Results: Linear accelerator 1 (LN1) met all stated CAT tolerances. Linear accelerator 2 (LN2) passed the geometric, beam symmetry, and MLC position error tests but failed the relative dose average test for the diaphragm abutment and all three picket fence fields. Though peak doses in the abutment regions were consistent, the average dose was below the stated tolerance corresponding to a leaf junction that was too narrow. Despite this, no significant differences in patient specific VMAT quality assurance measured were observed between the accelerators and both passed monthly MLC quality assurance performed with the Hancock test. Conclusion: Results from the CAT showed LN2 with relative dose averages in the abutment regions of the diaphragm and MLC tests outside the tolerances resulting from differences in leaf gap distances. Tolerances of the dose average tests from the CAT may be small enough to detect MLC errors which do not significantly affect patient QA or the routine MLC tests.

60 APPLIED LIFE SCIENCES↗

Radar Level Measurement in the Presence of Foam Using an LAW High Bound Pretreated Waste Simulant

During previous testing with LAW simulants, the radar level detector, installed in a scale WTP LAW CRV tank at the VSL, worked well when the tank was being mixed. However, if the agitator was stopped and foam was present on the surface, then the radar detector measured the distance to the top of the foam, not the liquid level beneath the foam. This finding has a significant impact on the WTP because if the foam is thick enough, this will cause a high-biased level reading which could affect the composition of the melter feed because too much GFCs would be added to the tank. To address the response of the radar level detector to foam, a Test Exception was issued to perform additional testing that would determine whether the radar level detector signal can be adjusted such that it can identify the foam and liquid levels and reliably operate in the presence of foam on the surface of the slurry. This final report provides results of the testing that was performed with the radar level detector in the presence of foam on the liquid surface.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transition to Online Cable Insulation Condition Monitoring

Nuclear power plant cables were originally qualified for 40 year life and generally have not required specific test verification to assure service availability through the initial plant qualification period. However, license renewals to 60 and 80 years of operation require a cable aging management program that depends on some form of test and verification to assure fitness for service. Environmental stress (temperature, radiation, chemicals, water, and mechanical) varies dramatically within a nuclear power plant and, in some cases, cables have degraded and required repair or replacement before their qualified end-of-life period. In other cases, cable conditions have been mild and dependable cable performance confirmed to extend well beyond the initial qualified life. Most offline performance-based testing requires cables to be de-coupled and de-energized for specially trained technicians to perform testing. These offline tests constitute an expensive operational burden that limits the economic viability of nuclear power plants. Although initial investment may be higher, new online test practices are emerging as options or complements to offline testing that avoid or minimize the regularly scheduled offline test burden. These online methods include electrical and fiber-optic partial discharge measurement, spread spectrum time or frequency domain reflectometry, distributed temperature profile measurements, and local interdigital capacitance measurement of insulation characteristics. Introduction of these methods must be supported by research to confirm efficacy plus either publicly financed or market driven investment to support the start-up expense of cost-effective instrumentation to monitor cable condition and assure reliable operation. This work summarizes various online cable assessment technologies plus introduces a new cable motor test bed to assess some of these technologies in a controlled test environment.

Glass, Samuel W.↗

Integrated Data Collection Analysis (IDCA) Program - KClO 3 /Dodecane Mixture

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small-Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 3 and dodecane—KClO 3 /dodecane mixture. This material was selected because of the challenge of performing SSST testing of a mixture of solid and liquid materials. The mixture was found to: 1) be more sensitive to impact than RDX, and PETN, 2) less sensitive to friction than PETN, and 3) less sensitive to spark than RDX. The thermal analysis showed little or no exothermic features suggesting that the dodecane volatilized at low temperatures. A prominent endothermic feature was observed assigned to melting of KClO 3 . This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 3 /dodecane mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), and Indian Head Division, Naval Surface Warfare Center, (NSWC IHD). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these things cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) program--KClO 4 /Dodecane Mixture

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 4 and dodecane—KClO 4 /dodecane mixture. This material was selected because of the challenge of performing SSST testing of a mixture of solid and liquid materials. The mixture was found to: 1) be less sensitive to impact than RDX, and PETN, 2) less sensitive to friction than RDX and PETN, and 3) less sensitive to spark than RDX and PETN. The thermal analysis showed little or no exothermic features suggesting that the dodecane volatilized at low temperatures. A prominent endothermic feature was observed and assigned to a phase transition of KClO 4 . This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 4 /dodecane mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these testing variables cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Data Collection Analysis (IDCA) Program - KClO 4 /Carbon Mixture

The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of a mixture of KClO 4 and activated carbon—KClO 4 /C mixture. This material was selected because of the challenge of performing SSST testing of a mixture of two solids. The mixture was found to be insensitive to impact, friction, and thermal stimulus, and somewhat sensitive to spark discharge. This effort, funded by the Department of Homeland Security (DHS), ultimately will put the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study has the potential to suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. Note, however, the test procedures differ among the laboratories. The results are compared among the laboratories and then compared to historical data from various sources. The testing performers involved for the KClO 4 /carbon mixture are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to understand how to compare results when these testing variables cannot be made consistent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of a Test Article and Test Facility to Investigate Flow-Induced Vibration of a Helical Coil Steam Generator

NuScale Power LLC (NuScale) is developing a small modular reactor (SMR) with unique design features and arrangements that require testing to provide quality data for safety analysis codes and design validation, as well as for technology maturation. A multi-phase testing program is underway at NuScale to demonstrate that its unique helical coil steam generator design is not susceptible to flow-induced vibration during operation. The phases of the testing program include modal testing of individual tubes during test article fabrication and modal and flow testing after test article completion. NuScale has contracted SIET S.p.A. in Piacenza, Italy for the design and fabrication of the test article and test facility. In-fabrication testing was performed at the site of test article build in Cremosano, Italy. Modal testing and flow testing of the completed test article will be performed at SIET’s facilities in Piacenza. This paper discusses the design of the test article and test facility, including supporting systems, required to generate the quality data required to support NuScale’s comprehensive vibration assessment program as part of the overall licensing effort for NuScale’s first-of-a-kind small modular light water reactor.

Flow-induced vibration, helical coil, steam genera↗

Ballistic penetration test results for Ductal and ultra-high performance concrete samples.

This document provides detailed test results of ballistic impact experiments performed on several types of high performance concrete. These tests were performed at the Sandia National Laboratories Shock Thermodynamic Applied Research Facility using a 50 caliber powder gun to study penetration resistance of concrete samples. This document provides test results for ballistic impact experiments performed on two types of concrete samples, (1) Ductal{reg_sign} concrete is a fiber reinforced high performance concrete patented by Lafarge Group and (2) ultra-high performance concrete (UHPC) produced in-house by DoD. These tests were performed as part of a research demonstration project overseen by USACE and ERDC, at the Sandia National Laboratories Shock Thermodynamic Applied Research (STAR) facility. Ballistic penetration tests were performed on a single stage research powder gun of 50 caliber bore using a full metal jacket M33 ball projectile with a nominal velocity of 914 m/s (3000 ft/s). Testing was observed by Beverly DiPaolo from ERDC-GSL. In all, 31 tests were performed to achieve the test objectives which were: (1) recovery of concrete test specimens for post mortem analysis and characterization at outside labs, (2) measurement of projectile impact velocity and post-penetration residual velocity from electronic and radiographic techniques and, (3) high-speed photography of the projectile prior to impact, impact and exit of the rear surface of the concrete construct, and (4) summarize the results.

36 MATERIALS SCIENCE↗

Fatigue Testing of Metallurgically-Bonded EBR-II Superheater Tubes

Fatigue crack growth and impact tests were performed on 2¼Cr-1Mo steel specimens machined from ex-service Experimental Breeder Reactor – II (EBR-II) superheater duplex tubes. The tubes had been metallurgically bonded with a 100 µm thick Ni layer; the specimens incorporated this bond layer. Impact tests were performed at temperatures from –50 to 400°C; cracks propagating from the V-notch were arrested by delamination at the bond layer for all tests with one exception at –50°C. Fatigue crack growth tests were performed at room temperature in air and at 400°C in air and humid Ar; cracks were grown at varied levels of constant ?K. In all conditions the presence of the Ni bond layer was found to result in a net retardation of growth as the crack passed through the layer. The mechanism of retardation was identified as a disruption of crack planarity and uniformity after passing through the porous bond layer. Full crack arrest was only observed in a single test performed at near-threshold ?K level (12 MPa?m) at 400°C. In this case the crack tip was blunted by oxidation of the base steel at the steel-nickel interface.

36 MATERIALS SCIENCE↗

EXPERIMENTS ON CAKE DEVELOPMENT IN CROSSFLOW FILTRATION FOR HIGH LEVEL WASTE

Crossflow filtration is a key process step in many operating and planned waste treatment facilities to separate undissolved solids from supernate slurries. This separation technology generally has the advantage of self cleaning through the action of wall shear stress, which is created by the flow of waste slurry through the filter tubes. However, the ability of filter wall self cleaning depends on the slurry being filtered. Many of the alkaline radioactive wastes are extremely challenging to filtration, e.g., those containing compounds of aluminum and iron, which have particles whose size and morphology reduces permeability. Low filter flux can be a bottleneck in waste processing facilities such as the Salt Waste Processing Facility at the Savannah River Site and the Waste Treatment Plant at the Hanford Site. Any improvement to the filtration rate would lead directly to increased throughput of the entire process. To date, increased rates are generally realized by either increasing the crossflow filter axial flowrate, which is limited by pump capacity, or by increasing filter surface area, which is limited by space and increases the required pump load. In the interest of accelerating waste treatment processing, DOE has funded studies to better understand filtration with the goal of improving filter fluxes in existing crossflow equipment. The Savannah River National Laboratory (SRNL) was included in those studies, with a focus on startup techniques and filter cake development. This paper discusses those filter studies. SRNL set up both dead-end and crossflow filter tests to better understand filter performance based on filter media structure, flow conditions, and filter cleaning. Using non-radioactive simulated wastes, which were both chemically and physically similar to the actual radioactive wastes, the authors performed several tests to demonstrate increases in filter performance. With the proper use of filter flow conditions filter flow rates can be increased over rates currently realized today. This paper describes the selection of a challenging simulated waste and crossflow filter tests to demonstrate how performance can be improved over current operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Evaluation of Heat Transfer in a High Temperature High Pressure Test Facility

Performance of film cooling holes is generally evaluated near ambient conditions, so scaling the film cooling performance from ambient to engine conditions is important. These performance metrics can be reported in terms of net heat flux reduction, heat transfer enhancement, and effectiveness. There are several challenges and penalties in conducting experiments on a real engine or even on a stationary flat plate test article at near engine conditions. In this study, an experimental methodology capable of delivering film cooling performance for the experiments conducted in the high-temperature high-pressure test facility at NETL will be explored. More specifically, this study focuses on various challenges that are present and how these concerns are addressed to evaluate the heat transfer coefficient on the test article. Steady state experiments were conducted on a flat plate test article whose surface temperature distribution was obtained using an IR camera calibrated with a combination of bench top experiments and in-situ calibrations based on embedded thermocouple measurements. A detailed radiation analysis is conducted to enable differentiation of heat transfer by convection from heat transfer by radiation. The estimated surface heat flux and heat transfer coefficient were found to be higher than the one obtained from flat plate correlation.

Ramesh, Sridharan↗

Sludge Batch 5 Slurry Fed Melt Rate Furnace Test with Frits 418 and 550

Based on Melt Rate Furnace (MRF) testing for the Sludge Batch 5 (SB5) projected composition and assessments of the potential frits with reasonable operating windows, the Savannah River National Laboratory (SRNL) recommended Slurry Fed Melt Rate Furnace (SMRF) testing with Frits 418 and 550. DWPF is currently using Frit 418 with SB5 based on SRNL's recommendation due to its ability to accommodate significant sodium variation in the sludge composition. However, experience with high boron containing frits in DWPF indicated a potential advantage for Frit 550 might exist. Therefore, SRNL performed SMRF testing to assess Frit 550's potential advantages. The results of SMRF testing with SB5 simulant indicate that there is no appreciable difference in melt rate between Frit 418 and Frit 550 at a targeted 34 weight % waste loading. Both batches exhibited comparable behavior when delivered through the feed tube by the peristaltic pump. Limited observation of the cold cap during both runs showed no indication of major cold cap mounding. MRF testing, performed after the SMRF runs due to time constraints, with the same two Slurry Mix Evaporator (SME) dried products led to the same conclusion. Although visual observations of the cross-sectioned MRF beakers indicated differences in the appearance of the two systems, the measured melt rates were both {approx}0.6 in/hr. Therefore, SRNL does not recommend a change from Frit 418 for the initial SB5 processing in DWPF. Once the actual SB5 composition is known and revised projections of SB5 after the neptunium stream addition and any decants is provided, SRNL will perform an additional compositional window assessment with Frit 418. If requested, SRNL can also include other potential frits in this assessment should processing of SB5 with Frit 418 result in less than desirable melter throughput in DWPF. The frits would then be subjected to melt rate testing at SRNL to determine any potential advantages.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The EGS Collab project: Outcomes and lessons learned from hydraulic fracture stimulations in crystalline rock at 1.25 and 1.5 km depth

With the goal of better understanding stimulation in crystalline rock for improving enhanced geothermal systems (EGS), the EGS Collab Project performed a series of stimulations and flow tests at 1.25 and 1.5 km depths. The tests were performed in two well-instrumented testbeds in the Sanford Underground Research Facility in Lead, South Dakota, United States. The testbed for Experiment 1 at 1.5 km depth contained two open wells for injection and production and six instrumented monitoring wells surrounding the targeted stimulation zone. Four multi-step stimulation tests targeting hydraulic fracturing and nearly year-long ambient temperature and chilled water flow tests were performed in Experiment 1. The testbed for Experiments 2 and 3 was at 1.25 km depth and contained five open wells in an outwardly fanning five-spot pattern and two fans of well-instrumented monitoring wells surrounding the targeted stimulation zone. Experiment 2 targeted shear stimulation, and Experiment 3 targeted low-flow, high-flow, and oscillating pressure stimulation strategies. Hydraulic fracturing was successful in Experiments 1 and 3 in generating a connected system wherein injected water could be collected. However, the resulting flow was distributed dynamically, and not entirely collected at the anticipated production well. Thermal breakthrough was not observed in the production well, but that could have been masked by the Joule-Thomson effect. Shear stimulation in Experiment 2 did not occur - despite attempting to pressurize the fractures most likely to shear - because of the inability to inject water into a mostly-healed fracture, and the low shear-to-normal stress ratio. The EGS Collab experiments are described to provide a background for lessons learned on topics including induced seismicity, the correlation between seismicity and permeability, distributed and dynamic flow systems, thermoelastic and pressure effects, shear stimulation, local geology, thermal breakthrough, monitoring stimulation, grouting boreholes, modeling, and system management.

15 - GEOTHERMAL ENERGY↗

Post mortem results of laser-optical system packaged for use in harsh environments

In this study, the design and packaging of laser-optical system was tested to harsh environments outside lab conditions and post mortem activities will be discussed. Previously, custom mounts and bonded optical assemblies were environmentally tested to ensure their survivability. The results verified the sub-assemblies would enable the design of a laser-optical initiation system that could be fielded for use in extreme conditions. The design package, which utilized the proven opto-mechanical sub-assemblies, was then tested to the same levels as the sub-assemblies. The test regiment encompassed the harshest environments currently utilized. Temperature tests were performed ranging from a maximum of +75 degrees C to a minimum of -55 degrees C, allowing for two hour soak at each temperature set point. Vibration tests were performed to a maximum level of 15.5 grms for forty seconds in each of three critical axes. Shock tests were performed to a maximum impulse level of 5700 G's for the sub-assemblies with a 1.1 millisecond long pulse; whereas the packaged laser system maximum level reached was 3700 G's at 1.1 millisecond long pulse. The laser-optical assembly was visually inspected and functionally tested before and after each test to verify survival. As designed, the system covers were laser welded shut for hermetic seal. The only open port was the laser output for testing and verification of laser performance. No optical cables were utilized. Therefore the visual inspection of the interior was performed post mortem. Finally, the post mortem results will be discussed as will the potential of redesigns on future packaging strategies.

42 ENGINEERING↗

Comparison of the performance of TLD, OSL and RPL personal dosimetry systems to the American National Standard Institute (ANSI) test categories

The Laboratory Accreditation Program (LAP) tests the capability and performance of the United States Department of Energy's (USDOE) facilities to accurately measure and quantify the whole-body and extremity radiation equivalent doses to the occupational workers. The dosimetry methods used in personal dosimetry can be Thermoluminescence (TL), Optically Stimulated Luminescence (OSL) and Radiophotoluminescence (RPL), among other techniques available. Currently, the TL (LiF:Mg,Ti) and OSL (Al 2 O 3 :C) dosimetry systems are DOELAP-accredited for occupational dose measurements and regulatory reporting. In this study, the performance of a beryllium oxide (BeO) OSL dosimetry system and of a silver-doped phosphate glass RPL dosimetry system is compared against the performance of an accredited LiF:Mg,Ti TL dosimetry system. The bias and standard deviation in each of the performance test categories are compared between these three systems for exposures to photons, beta, and mixed radiation fields with the criteria established by the American National Standard Institute (ANSI) and Health Physics Society (HPS) N13.11-2022 standard. The practical implementation of the dosimetry program and its equivalency to the occupational personal equivalent dose H p (0.07) and H p (10) measurements were evaluated. The TL, OSL and RPL dosimetry systems passed the ANSI performance test criteria for H p (0.07) and H p (10) occupational dose measurements and met the DOELAP accreditation requirements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental Investigation of Drillstring Torsional Vibration Effect on Rate of Penetration with PDC Bits in Hard Rock

Polycrystalline diamond compact (PDC) bits have shown tremendous performance compared to roller cone bits and have gained attraction in deep geothermal drilling applications. While PDC bits can reach a higher rate of penetration compared to other bits, they are more prone to drilling vibrations. The scope of this paper is to quantify the effects of drillstring torsional vibrations on PDC bit performance using a laboratory testing facility. Here, the tests were performed with three drillstring configurations to evaluate the effect of drillstring vibrations. The results showed that rigid testing overestimates the bit rate of penetration by 35% due to torsional vibrations.

15 GEOTHERMAL ENERGY↗

Post-Transient Examination Results of RIA Commissioning Teats at the Transient Reactor Test Facility

Six reactivity-initiated-accident (RIA) commissioning tests have been performed at Idaho National Laboratory’s (INL) Transient Reactor Test Facility. Five of these tests were performed using fresh fuel rodlets, and the sixth test was performed using a previously irradiated rodlet from the ATF-2 irradiation experiment. These experiments demonstrate the ability to perform RIA testing including the ability to perform experiments using previously irradiated materials. Post-transient examinations revealed pellet cladding interactions and cladding ballooning depending on the initial boundary conditions of the test. Increased thickness of both zirconium oxide and alpha-zirconium were found in the cladding with tests performed at higher levels of total energy deposition. No oxide or alpha-zirconium was found in the test with the greatest amount of ballooning, which was also the test with the highest initial rod internal pressure. The highest energy deposition test (1110 J/g) resulted in failure of the rodlet. Fragmentation of the fuel pellets occurred in this test with the size of the fragments decreasing inversely to the pellet radius.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗