Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TUBING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

DGEN Aeropropulsion Research Turbofan (DART) Core/Combustor-Noise Infinite-Tube-Probe (ITP) Transfer Function

Direct measurements of turbofan engine core unsteady pressure is complicated by the extreme thermal environment within the engine, preventing currently available transducers from operating. It is necessary to use a remote measurement configuration such as an infinite-tube-probe (ITP) configuration in which the transducer is teed into a line pneumatically coupled with the location of interest and the other end of the ITP contains an "infinite" waveguide designed to prevent any reflections. This configuration has become a standard method for experiments concerning core noise. In order to relate the spectral pressure measurements obtained remotely with the ITP, a transfer (frequency response) function needs to be calculated based on a known pressure field. This is accomplished using a normal impedance tube at Glenn Research Center, where a flush-mounted microphone is used as a reference to the ITP signal in the calculation of the ITP's transfer function.

Boyle, Devin K.↗

Transfer-Function Determination for Infinite-Tube-Probe Pressure Transducers with Application to Turbofan Core/Combustor Noise

Turbofan hot-section unsteady pressure measurements are complicated by environmental limitations of current-generation sensors. Accurate direct measurements are normally not possible and engine-external measurement techniques, using sufficiently long sense lines, are utilized instead. Remote measurement comes at a cost, however, as it introduces a magnitude reduction within the line as well as a phase lag relative to the desired engine-internal measurement location. Determination, or validation, of a transfer function relating the engine internal pressure to the observed remote value is necessary. Transfer functions are examined for various configurations of the so-called infinite-tube-probe arrangement in order to optimize measurement performance. The experimental setup uses a normal-incidence tube that ordinarily is utilized for impedance eduction. Here, its downstream end instead is made up of a hard-wall termination instrumented with a flush-mounted microphone and a Kulite pressure transducer as well as a sense line connection. This allows the remote and direct measurements to be related under controlled conditions. Transfer-function measurements are presented and compared to predictions for several parametric variations.

Combustor Noise↗

Transfer-Function Determination for Infinite-Tube-Probe Pressure Transducers with Application to Turbofan Core/Combuster Noise

Turbofan hot-section unsteady pressure measurements are complicated by environmental limitations of current-generation sensors. Accurate direct measurements are normally not possible and engine-external measurement techniques, using sufficiently long sense lines, are utilized instead. Remote measurement comes at a cost, however, as it introduces a magnitude reduction within the line as well as a phase lag relative to the desired engine-internal measurement location. Determination, or validation, of a transfer function relating the engine internal pressure to the observed remote value is necessary. Transfer functions are examined for various configurations of the so-called infinite-tube-probe arrangement in order to optimize measurement performance. The experimental setup uses a normal-incidence tube that ordinarily is utilized for impedance eduction. Here, its downstream end instead is made up of a hard-wall termination instrumented with a flush-mounted microphone and a Kulite pressure transducer as well as a sense line connection. This allows the remote and direct measurements to be related under controlled conditions. Transfer-function measurements are presented and compared to predictions for several parametric variations.

Turbomachinery Noise↗

Computational Modeling for Non-Equilibrium Shock Tube Flows

Time accurate simulation of non-equilibrium flows inside shock tube facilities presents several challenges from both physical and mathematical aspects. Furthermore, the large computational cost makes it impractical to support a real-time experimental test campaign. In this work, we explore other methods for modeling the shock tube problem with the main focus on the post-shock region and the absolute radiation emanating from it. The proposed alternative approach is several orders of magnitude less computationally expensive while still accurate enough with regards to the quantities of interest. Excellent agreement is found with the established stagnation-line approach. Comparison with time-accurate simulations shows good agreement close to the peak values and disagreement of the temperatures relaxation and radiance profiles toward equilibrium.

Bensassi, Khalil↗

Computational Modeling for Non-equilibrium Shock Tube Flows

Time accurate simulation of non-equilibrium flows inside shock tube facilities presents several challenges from both physical and mathematical aspects. Furthermore, the drastic computational cost makes it non-practical to support real-time experimental test campaign. In this work, we explore other methods for modeling the shock tube prob- lem with the main focus on the post-shock region and the absolute radiation emanating from it. The proposed alternative approach is several orders of magnitude less computa- tionally expansive while still accurate enough with regards to the quantities of interest. Excellent agreement is found with the well-established stagnation-line approach. Comparison with the time-accurate simulation shows good agreement close to the peak values and disagreement of the temperatures relaxation and radiance profiles toward equilibrium, due to shock speed unsteadiness.

Bensassi, Khalil↗

A NASA First in Nano-Technology: Nanoscale Vacuum Tube for Radiation Immune Electronics

Vacuum provides the fastest electron speed, better than any semiconductor. Nevertheless vacuum tubes were bulky, fragile and consumed much power. Now nanotechnology has enabled fabrication of vacuum tubes at nanoscale in silicon chips. The speed, immunity to radiation and high temperature operation are expected to revolutionize space electronics.

Ingrid Desilestre↗

Gated-Dynode Photomultiplier Tube Assembly for the Boronated Scintillator Detector of the ISS-CREAM Experiment

We present the design of a four-photomultiplier tube (PMT) assembly for measuring light generation in theBoronated Scintillator Detector (BSD) of the Cosmic Ray Energetics And Mass experiment for the InternationalSpace Station (ISS-CREAM). The light produced in the scintillator includes a contribution from the captureof thermalized neutrons produced in cosmic ray interactions, as well as delayed fluorescence, in the range ofseveral microseconds following the incident cosmic ray impact. The BSD is held in an insensitive state until acosmic-ray trigger causes a rapid turn on of the PMTs to detect late light signals, several microseconds afterthe trigger. The design includes two pulsed high-voltage supplies, which serve to gate the first two dynodesof the Hamamatsu R1924A PMTs used in the assembly. When the dynode gates are held in the "off" state,this scheme is shown to suppress >105 photons from injection into the tube's multiplier stage, while beingcapable of rapid switching into a stable operating mode in less than 1 s. This mitigates any backgroundsfrom afterpulsing that might otherwise be present in the PMT response following the cosmic ray incidence.

Anderson, T.↗

Over-the-Rotor Liner Investigation via the NASA Langley Normal Incidence Tube

NASA Langley and Glenn Research Centers have collaborated on the usage of acoustic liners mounted very near or directly over the rotor of turbofan aircraft engines. This collaboration began over a decade ago with the investigation of a metallic foam liner. Similar to conventional acoustic liner applications, this liner was designed to absorb sound generated by the rotor-alone and rotor-stator interaction sources within the fan duct. Given its proximity to the rotor tips, the expectation was that the liner would also serve as a pressure release and thereby inhibit the amount of noise generated. Initial acoustic results were promising, but there was concern regarding potential aerodynamic penalties. Nevertheless, there were sufficient positive results to warrant further investigation. To that end, the current report presents results obtained in the NASA Langley Normal Incidence Tube for 20 acoustic liner candidates for the OTR application. The majority contain grooves at their surface, designed to minimize aerodynamic penalties caused by placing the liner in close proximity to the fan rotor tips. The intent is to assess the acoustic properties of each liner configuration, and in particular to assess the effects of including the grooves on the overall acoustic performance. An additional intent of this paper is to provide documentation regarding recent enhancements to the NASA Langley Normal Incidence Tube.

Jones, Michael G↗

High Intensity Modal Impedance Tube Development at NASA Langley

A High Intensity Modal Impedance Tube (HIMIT) was developed for evaluation of acoustic liners in a normal incidence, high sound pressure level (SPL), and high frequency environment. Capabilities of the HIMIT are demonstrated here by testing three classes of acoustic liners: a narrow chamber liner, conventional single degree of freedom liners, and over-the-rotor liners. The experimental results are compared to results in NASA Langley's Normal Incidence Tube (NIT) for validation. The Zwikker and Kosten Transmission Line (ZKTL) model is also compared to the HIMIT results for selected configurations to study its applicability at high SPLs and frequencies. The HIMIT and NIT impedance spectra compare favorably up to 3.0 kHz, which is the upper frequency limit of the NIT analysis. The ZKTL model was used at frequencies up to 6.0 kHz and showed great comparison for the entire frequency range tested, indicating that the model may be used at high frequencies when the plane wave mode is dominant.

Chelsea Solano↗

Consolidation of Braided Carbon Fiber/ Thermoplastic Tubes by Induction Heating

Thermoplastic composites have experienced renewed enthusiasm within the U.S. aerospace industry, due in part to opportunities for rapidly manufacturing large structures. Unlike the lengthy cure cycles required by thermosets, the thermoplastic matrix prepreg requires only heat and pressure to consolidate consecutive layers of material; with sufficient inter-ply contact time to develop a strong interface. The manufacturing requirements for thermoplastics provide manufacturing flexibility and of particular interest are in-situ consolidation processes; i.e consolidation during layup on a tool. In-situ consolidation removes the time-consuming and costly secondary processing step of autoclave or press consolidation. Process variables which contribute to laminate quality include temperature, heat transfer, inter-ply contact time, and consolidation pressure. Most of the work to date related to in-situ consolidation has been in conjunction with automated fiber placement (AFP), where prepreg tows are consolidated when placed on the tool. Considering this process for a braided structure adds complexity relative to AFP due to the rapid lay-down rate of the braider and simultaneous placement of a multiple prepreg tows. Processes considered for consolidation during AFP could not be applied to a braided part. Alternatively, a fully braided preform could be consolidated on the tool using well established thermoplastic welding techniques. The goal of this effort was to evaluate the effectiveness of induction welding to consolidate braided carbon fiber/thermoplastic composite tubes up to eight plies in thickness. The manufacturing process, thermal characterization, and initial mechanical property data of the consolidated tubes are reported.

In-situ consolidation, induction heating/welding, ↗

Comparison of Oxygen Liquefaction Gaseous Oxygen Injection via Ullage and Dip Tube

The Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) testing demonstrated constant and transient oxygen liquefaction in a scaled lander tank integrated with an industrial cryocooler. Early in the test series, two methods for injecting gaseous oxygen into the test tank were ran under similar constant liquefaction conditions for comparison. Gaseous oxygen was either injected directly from the lid into the ullage or bubbled up through the liquid using a dip tube that extends to the bottom of the test tank. The direct comparison of these gaseous oxygen injection methods for constant liquefaction indicated ullage injection provided a greater liquefaction rate than injection via a dip tube. Injection through the ullage was subsequently selected as the nominal injection method for the CryoFILL test series. The comparison of the two injection methods will be highlighted with a discussion of what may cause the variation in liquefaction rate.

Cryogenic Fluid Management↗

Fabrication and Mechanical Testing of Heat Exchanger Tubes for Nuclear Propulsion and Other Applications from Continuous Carbon Nanotube Yarns and Tapes

As NASA and other agencies are looking to conduct sustained operations in space, nuclear engines have been receiving increased focus. The high specific impulse and high fuel efficiency at high thrust output of these engines can halve the transit time for human missions to Mars, or enable missions requiring multiple orbital parameter adjustments. In both Nuclear Thermal Propulsion (NTP) and Nuclear Electric Propulsion (NEP) systems, heat exchangers play a critical role in transferring energy from the reactor to a working fluid, hydrogen in the case of NTP and a molten salt or other fluid for electricity generation in NEP. Heat exchangers are also required in other parts of the spacecraft. Various manufacturing methods and materials are being considered for the heat exchangers. In this presentation the fabrication and testing of heat exchangers made from continuous carbon nanotube (CNT) yarns and tapes are discussed. The fabrication workflow is compared and contrasted, as well as performance of prototype heat exchanger tubes fabricated using the various CNT formats. The failure loads and mechanisms of the tubes under tensile, compression, and bending loads are assessed. A further comparison of the CNT materials to components fabricated from carbon fiber is made. The presented work will contribute to the selection of approaches for heat exchanger fabrication methods for nuclear propulsion and other applications.

Heat Exchanger↗

Thermophysical Properties of Pore-confined Supercritical CO2 by Vibrating Tube Densimetry

Properties of fluids confined in pore systems are needed for modeling fluid flow, fluid-rock interactions, and changes in reservoir porosity. The properties of CO2-rich fluids are particularly relevant to geothermal heat mining using carbon dioxide instead of water. While manometric, volumetric, and gravimetric techniques have been used successfully to investigate adsorption of low-density subcritical vapors, the results have not been satisfactory at higher, liquid-like densities of supercritical fluids. Even if the requirements for high experimental accuracy in the neighborhood of the critical region were met, these methods are fundamentally unable to deliver the total adsorption capacity, since the properties (e.g. density) of the adsorbed phase are in general not known. In this work we utilize vibrating tube densimetry for the first time to measure the total amount of fluid contained within a mesoporous solid. The method is first demonstrated using propane at subcritical and supercritical temperatures between 35 C and 97 C confined in silica aerogel (density 0.2 g cm-3, porosity 90%) that was synthesized inside Hastelloy U-tubes. Sorption and desorption of carbon dioxide on the same solid was measured at 35 C at pressures to 120 bar (density to 0.767 g cm-3). The results show total adsorption increasing monotonically with increasing pressure, unlike excess adsorption isotherms which show a maximum close to the critical density.

36 MATERIALS SCIENCE↗

3D Surface Mapping of Capsule Fill-Tube Assemblies used in Laser-Driven Fusion Targets

This paper presents the development of a 3D surface mapping system used to measure the surface of a fusion target Capsule Fill-Tube Assembly (CFTA). The CFTA consists of a hollow Ge-doped plastic sphere, called a capsule, ranging in outer diameter between 2.2 mm and 2.6 mm and an attached 150 {micro}m diameter glass-core fill-tube that tapers down to a 10{micro} diameter at the capsule. The mapping system is an enabling technology to facilitate a quality assurance program and to archive 3D surface information of each capsule used in fusion ignition experiments that are currently being performed at the National Ignition Facility (NIF). The 3D Surface Mapping System is designed to locate and quantify surface features with a height of 50 nm and 300 nm in width or larger. Additionally, the system will be calibrated such that the 3D measured surface can be related to the capsule surface angular coordinate system to within 0.25 degree (1{sigma}), which corresponds to approximately 5 {micro}m linear error on the capsule surface.

42 ENGINEERING↗

Development of a Permanent-Magnet Microwave Ion Source for a Sealed-Tube Neutron Generator

A microwave ion source has been designed and constructed for use with a sealed-tube, high-yield neutron generator. When operated with a tritium-deuterium gas mixture the generator will be capable of producing 5*1011 n/s in non-proliferation applications. Microwave ion sources are well suited for such a device because they can produce high extracted beam currents with a high atomic fraction at low gas pressures of 0.2-0.3 Pa required for sealed tube operation. The magnetic field strength for achieving electron cyclotron resonance (ECR) condition, 87.5 mT at 2.45 GHz microwave frequency, was generated and shaped with permanent magnets surrounding the plasma chamber and a ferromagnetic plasma electrode. This approach resulted in a compact ion source that matches the neutron generator requirements. The needed proton-equivalent extracted beam current density of 40 mA/cm^2 was obtained at moderate microwave power levels of 400 W. Results on magnetic field design, pressure dependency and atomic fraction measured for different wall materials are presented.

43 PARTICLE ACCELERATORS↗

Plasma Sprayed Pour Tubes and Other Melt Handling Components for Use in Gas Atomization

Ames Laboratory has successfully used plasma sprayed ceramic components made from yttria stabilized zirconia as melt pouring tubes for gas atomization for many years. These tubes have proven to be strong, thermal shock resistant and versatile. Various configurations are possible both internally and externally. Accurate dimensions are achieved internally with a machined fugitive graphite mandrel and externally by diamond grinding. The previous study of the effect of spray parameters on density was extended to determine the effect of the resulting density on the thermal shock characteristics on down-quenching and up-quenching. Encouraging results also prompted investigation of the use of plasma spraying as a method to construct a melt pour exit stopper that is mechanically robust, thermal shock resistant, and not susceptible to attack by reactive melt additions. The Ames Laboratory operates two close-coupled high pressure gas atomizers. These two atomizers are designed to produce fine and coarse spherical metal powders (5{mu} to 500{mu} diameter) of many different metals and alloys. The systems vary in size, but generally the smaller atomizer can produce up to 5 kg of powder whereas the larger can produce up to 25 kg depending on the charge form and density. In order to make powders of such varying compositions, it is necessary to have melt systems capable of heating and containing the liquid charge to the desired superheat temperature prior to pouring through the atomization nozzle. For some metals and alloys this is not a problem; however for some more reactive and/or high melting materials this can pose unique challenges. Figure 1 is a schematic that illustrates the atomization system and its components.

36 MATERIALS SCIENCE↗

Electron tube

An electron tube of the present invention includes: a vacuum vessel including a face plate portion made of synthetic silica and having a surface on which a photoelectric surface is provided, a stem portion arranged facing the photoelectric surface and made of synthetic silica, and a side tube portion having one end connected to the face plate portion and the other end connected to the stem portion and made of synthetic silica; a projection portion arranged in the vacuum vessel, extending from the stem portion toward the photoelectric surface, and made of synthetic silica; and an electron detector arranged on the projection portion, for detecting electrons from the photoelectric surface, and made of silicon.

47 OTHER INSTRUMENTATION↗

A Multi-Anode Photomultiplier Tube Based Wavelength-Shifting-Fiber Detector for neutron diffraction

The wavelength-shifting (WLS) fiber scintillator neutron detectors were developed for two time-of-flight (TOF) neutron powder diffractometers (POWGEN, VULCAN) at Spallation Neutron Source (SNS). In a recent module (v3.0), however, there are 32 1-inch-diameter photomultiplier tubes (PMTs) which are bulky and expensive. We built a new detector module (v3.1) based on four multi-anode (MA) PMTs, and tested its performance including detection efficiency, count rate capability, spatial resolution, ghosting properties, and gamma-ray sensitivity. The v3.1 module was compared with two prior v3.0 modules, and 3He tube detectors.

Berry, Kevin D↗