Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systematic Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Simultaneous Sensing Error Recovery and Tomographic Inversion Using an Optimization-Based Approach

Tomography can be used to reveal internal properties of a 3D object using any penetrating wave. Advanced tomographic imaging techniques, however, are vulnerable to both systematic and random errors associated with the experimental conditions, which are often beyond the capabilities of the state-of-the-art reconstruction techniques such as regularizations. Because they can lead to reduced spatial resolution and even misinterpretation of the underlying sample structures, these errors present a fundamental obstacle to full realization of the capabilities of next-generation physical imaging. In this work, we develop efficient and explicit recovery schemes of the most common experimental error: movement of the center of rotation during the experiment. We formulate new physical models to capture the experimental setup, and we devise new mathematical optimization formulations for reliable inversion of complex samples. We demonstrate and validate the efficacy of our approach on synthetic data under known perturbations of the center of rotation.

Nonlinear optimization↗

MO-E-BRB-04: Real-Time Exit-Fluence Delivery Validation

Recent high profile reports of technical failures and human errors causing severe radiation- induced injuries and deaths come in support of the sustained efforts to ensure patient safety in the delivery of radiation treatments. In addition, highly conformal radiation therapies and escalated fraction doses mandate increased and sustained accuracy of the entire radiotherapy process. Consequently, and as a Result of AAPM and ASTRO led efforts patient specific quality assurance for specialized radiation treatments such as IMRT, SRS/SBRT and Arc Therapy had become a three-tier process: Pre-treatment, during treatment, and post treatment patient specific QA. Traditional patient QA consists of pre-treatment data transfer integrity dosimetric verifications and during-treatment geometric verifications. However, as treatment adaptation becomes closer to deployment in the clinics, during treatment validation via exit detectors had become a realistic QA option, permitting plan assessment in near real time. Post-treatment, machine logs allow comparisons of a range of mechanical parameters. A combination of these techniques could be used in evaluating inter-fraction, and intra-fraction delivery over a long time period such as an year, to evaluate the significant errors per site, per treatment technique. This type of data mining over longer periods of time provides the potential to recognize suboptimal radiation treatments, while allowing to identify systematic, possibly significant errors. This would allow creation of a data base of realized errors, small and large in dosimetry that could be for process or equipment improvement. This educational symposium will describe and review patient QA techniques, results, and strategies for patient specific quality assurance. Learning Objectives: review the goals of pre-treatment QA for various specialized procedures review methods and means for pre-treatment QA, limitations and tolerances review the scenarios where Varian/Tomo Log files could be used. review error detection via log file analysis Learn how exit detector signal recorded in log file could be used to improve patient safety understand real-time EPID-based transmission dosimetry methods understand the goals of real-time delivery monitoring CMS Innovation grant. Rapid response supportive and palliative care program for patients with advanced cancer, starts July, 2012; Accuray Inc. Exit detector based QA software evaluation, Sept, 2012-Sept, 2013; ROI GRant from ASTRO “Safety and Quality: IMRT treatment delivery accuracy”.

60 APPLIED LIFE SCIENCES↗

Effect of MLC leaf position, collimator rotation angle, and gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma

The purpose of this study was to investigate the effect of multileaf collimator (MLC) leaf position, collimator rotation angle, and accelerator gantry rotation angle errors on intensity-modulated radiotherapy plans for nasopharyngeal carcinoma. To compare dosimetric differences between the simulating plans and the clinical plans with evaluation parameters, 6 patients with nasopharyngeal carcinoma were selected for simulation of systematic and random MLC leaf position errors, collimator rotation angle errors, and accelerator gantry rotation angle errors. There was a high sensitivity to dose distribution for systematic MLC leaf position errors in response to field size. When the systematic MLC position errors were 0.5, 1, and 2 mm, respectively, the maximum values of the mean dose deviation, observed in parotid glands, were 4.63%, 8.69%, and 18.32%, respectively. The dosimetric effect was comparatively small for systematic MLC shift errors. For random MLC errors up to 2 mm and collimator and gantry rotation angle errors up to 0.5°, the dosimetric effect was negligible. We suggest that quality control be regularly conducted for MLC leaves, so as to ensure that systematic MLC leaf position errors are within 0.5 mm. Because the dosimetric effect of 0.5° collimator and gantry rotation angle errors is negligible, it can be concluded that setting a proper threshold for allowed errors of collimator and gantry rotation angle may increase treatment efficacy and reduce treatment time.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-AB-202-02: Real-Time Verification and Error Detection for MLC Tracking Deliveries Using An Electronic Portal Imaging Device

Purpose: The added complexity of the real-time adaptive multi-leaf collimator (MLC) tracking increases the likelihood of undetected MLC delivery errors. In this work we develop and test a system for real-time delivery verification and error detection for MLC tracking radiotherapy using an electronic portal imaging device (EPID). Methods: The delivery verification system relies on acquisition and real-time analysis of transit EPID image frames acquired at 8.41 fps. In-house software was developed to extract the MLC positions from each image frame. Three comparison metrics were used to verify the MLC positions in real-time: (1) field size, (2) field location and, (3) field shape. The delivery verification system was tested for 8 VMAT MLC tracking deliveries (4 prostate and 4 lung) where real patient target motion was reproduced using a Hexamotion motion stage and a Calypso system. Sensitivity and detection delay was quantified for various types of MLC and system errors. Results: For both the prostate and lung test deliveries the MLC-defined field size was measured with an accuracy of 1.25 cm{sup 2} (1 SD). The field location was measured with an accuracy of 0.6 mm and 0.8 mm (1 SD) for lung and prostate respectively. Field location errors (i.e. tracking in wrong direction) with a magnitude of 3 mm were detected within 0.4 s of occurrence in the X direction and 0.8 s in the Y direction. Systematic MLC gap errors were detected as small as 3 mm. The method was not found to be sensitive to random MLC errors and individual MLC calibration errors up to 5 mm. Conclusion: EPID imaging may be used for independent real-time verification of MLC trajectories during MLC tracking deliveries. Thresholds have been determined for error detection and the system has been shown to be sensitive to a range of delivery errors.

60 APPLIED LIFE SCIENCES↗

Systematic softening in universal machine learning interatomic potentials

Machine learning interatomic potentials (MLIPs) have introduced a new paradigm for atomic simulations. Recent advancements have led to universal MLIPs (uMLIPs) that are pre-trained on diverse datasets, providing opportunities for universal force fields and foundational machine learning models. However, their performance in extrapolating to out-of-distribution complex atomic environments remains unclear. In this study, we highlight a consistent potential energy surface (PES) softening effect in three uMLIPs: M3GNet, CHGNet, and MACE-MP-0, which is characterized by energy and force underprediction in atomic-modeling benchmarks including surfaces, defects, solid-solution energetics, ion migration barriers, phonon vibration modes, and general high-energy states. The PES softening behavior originates primarily from the systematically underpredicted PES curvature, which derives from the biased sampling of near-equilibrium atomic arrangements in uMLIP pre-training datasets. Our findings suggest that a considerable fraction of uMLIP errors are highly systematic, and can therefore be efficiently corrected. We argue for the importance of a comprehensive materials dataset with improved PES sampling for next-generation foundational MLIPs.

36 MATERIALS SCIENCE↗

COMPARING THE ENERGY SPECTRA OF ULTRAHIGH ENERGY COSMIC RAYS MEASURED WITH EXTENSIVE AIR SHOWER ARRAYS

The energy spectra of ultrahigh energy cosmic rays (CRs) measured with giant extensive air shower (EAS) arrays exhibit discrepancies between the flux intensities and/or estimated CR energies exceeding experimental errors. The well-known intensity correction factor due to the dispersion of the measured quantity in the presence of a rapidly falling energy spectrum is insufficient to explain the divergence. Another source of systematic energy determination error is proposed concerning the charged particle density measured with the surface arrays, which arises due to simplifications (namely, the superposition approximation) in nucleus-nucleus interaction description applied to the shower modeling. Making use of the essential correction factors results in congruous CR energy spectra within experimental errors. Residual differences in the energy scales of giant arrays can be attributed to the actual overall accuracy of the EAS detection technique used. CR acceleration and propagation model simulations using the dip and ankle scenarios of the transition from galactic to extragalactic CR components are in agreement with the combined energy spectrum observed with EAS arrays.

79 ASTRONOMY AND ASTROPHYSICS↗

Interfraction rotation of the prostate as evaluated by kilovoltage X-ray fiducial marker imaging in intensity-modulated radiotherapy of localized prostate cancer

To quantify the daily rotation of the prostate during a radiotherapy course using stereoscopic kilovoltage (kV) x-ray imaging and intraprostatic fiducials for localization and positioning correction. From 2005 to 2009, radio-opaque fiducial markers were inserted into 38 patients via perineum into the prostate. The ExacTrac/Novalis Body X-ray 6-day image acquisition system (ET/NB; BrainLab AG, Feldkirchen, Germany) was used to determine and correct the target position. During the first period in 10 patients we recorded all rotation errors but used only Y (table) for correction. For the next 28 patients we used for correction all rotational coordinates, i.e., in addition Z (superior-inferior [SI] or roll) and X (left-right [LR] or tilt/pitch) according to the fiducial marker position by use of the Robotic Tilt Module and Varian Exact Couch. Rotation correction was applied above a threshold of 1 Degree-Sign displacement. The systematic and random errors were specified. Overall, 993 software-assisted rotational corrections were performed. The interfraction rotation errors of the prostate as assessed from the radiodense surrogate markers around the three axes Y, Z, and X were on average 0.09, -0.52, and -0.01 Degree-Sign with standard deviations of 2.01, 2.30, and 3.95 Degree-Sign , respectively. The systematic uncertainty per patient for prostate rotation was estimated with 2.30, 1.56, and 4.13 Degree-Sign and the mean random components with 1.81, 2.02, and 3.09 Degree-Sign . The largest rotational errors occurred around the X-axis (pitch), but without preferring a certain orientation. Although the error around Z (roll) can be compensated on average by a transformation with 4 coordinates, a significant error around X remains and advocates the full correction with 6 coordinates. Rotational errors as assessed via daily stereoscopic online imaging are significant and dominate around X. Rotation possibly degrades the dosimetric coverage of the target volume and may require suitable strategies for correction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Processing Aleatory and Epistemic Uncertainties in Experimental Data From Sparse Replicate Tests of Stochastic Systems for Real-Space Model Validation

This paper presents a practical methodology for propagating and processing uncertainties associated with random measurement and estimation errors (that vary from test-to-test) and systematic measurement and estimation errors (uncertain but similar from test-to-test) in inputs and outputs of replicate tests to characterize response variability of stochastically varying test units. Also treated are test condition control variability from test-to-test and sampling uncertainty due to limited numbers of replicate tests. These aleatory variabilities and epistemic uncertainties result in uncertainty on computed statistics of output response quantities. The methodology was developed in the context of processing experimental data for “real-space” (RS) model validation comparisons against model-predicted statistics and uncertainty thereof. The methodology is flexible and sufficient for many types of experimental and data uncertainty, offering the most extensive data uncertainty quantification (UQ) treatment of any model validation method the authors are aware of. It handles both interval and probabilistic uncertainty descriptions and can be performed with relatively little computational cost through use of simple and effective dimension- and order-adaptive polynomial response surfaces in a Monte Carlo (MC) uncertainty propagation approach. A key feature of the progressively upgraded response surfaces is that they enable estimation of propagation error contributed by the surrogate model. Sensitivity analysis of the relative contributions of the various uncertainty sources to the total uncertainty of statistical estimates is also presented. Finally, the methodologies are demonstrated on real experimental validation data involving all the mentioned sources and types of error and uncertainty in five replicate tests of pressure vessels heated and pressurized to failure. Simple spreadsheet procedures are used for all processing operations.

97 MATHEMATICS AND COMPUTING↗

Enhancing quantum memory lifetime with measurement-free local error correction and reinforcement learning

Reliable quantum computation requires systematic identification and correction of errors that occur and accumulate in quantum hardware. To diagnose and correct such errors, standard quantum error-correcting protocols utilize global error information across the system obtained by mid-circuit readout of ancillary qubits. We investigate circuit-level error-correcting protocols that are measurement-free and based on local error information. Such a local error correction (LEC) circuit consists of faulty multi-qubit gates to perform both syndrome extraction and ancilla-controlled error removal. We develop and implement a reinforcement learning framework that takes a fixed set of faulty gates as inputs and outputs an optimized LEC circuit. To evaluate this approach, we quantitatively characterize an extension of logical qubit lifetime by a noisy LEC circuit. For the two-dimensional (2D) classical Ising model and four-dimensional toric code, our optimized LEC circuit performs better at extending a memory lifetime compared with a conventional LEC circuit based on Toom's rule in a subthreshold gate error regime. We further show that such circuits can be used to reduce the rate of mid-circuit readouts to preserve a 2D toric code memory. Lastly, we discuss the application of the LEC protocol on dissipative preparation of quantum states with topological phases.

74 ATOMIC AND MOLECULAR PHYSICS↗

On the use of Graphs for Test Sequence Selection

This report demonstrates that applying graph theory techniques provides a way to obtain sufficient statistics in finding errors when testing complex state machines. It discusses how to define the tests, then demonstrates how to automatically generate test suites that diversify test cases, subject to constraints. If included within a continuous integration approach, these constructs provide an unbiased means to systematically check for errors within the latest controller software release.

97 MATHEMATICS AND COMPUTING↗

Imperfect slope measurements drive overestimation in a geometric cone model of lake and reservoir depth

Lake and reservoir (waterbody) depth is a critical characteristic that influences many important ecological processes. Unfortunately, depth measurements are labor-intensive to gather and are only available for a small fraction of waterbodies globally. Therefore, scientists have tried to predict depth from characteristics easily obtained for all waterbodies, such as surface area or the slope of the surrounding land. One approach for predicting waterbody depth simulates basins using a geometric cone model where the nearshore land slope and distance to the center of the waterbody are assumed to be representative proxies for in-lake slope and distance to the deepest point respectively. We tested these assumptions using bathymetry data from ~5000 lakes and reservoirs to examine whether differences in waterbody type or shape influenced depth prediction error. Here, we found that nearshore land slope was not representative of in-lake slope, and using it for prediction increases error substantially relative to models using true in-lake slope for all waterbody types and shapes. Predictions were biased toward overprediction in concave waterbodies (i.e., bowl-shaped; up to 18% of the study population) and reservoir waterbodies (up to 30% of the study population). Despite this systematic overprediction, model errors were fewer (in absolute and relative terms, irrespective of any specific slope covariate) for concave than convex waterbodies, suggesting the geometric cone model is an adequate representation of depth for these waterbodies. But because convex waterbodies are far more common (>72% of our study population), minimizing overall depth prediction error remains a challenge.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Rotational Errors in Treatment Setup of Stereotactic Body Radiation Therapy of Liver Cancer

Purpose: To evaluate the dosimetric impact of rotational setup errors in stereotactic body radiotherapy (SBRT) treatment of liver tumors and to investigate whether translational shifts can compensate for rotation. Methods and Materials: The positioning accuracy in 20 patients with liver malignancies treated with SBRT was reevaluated offline by matching the patients' cone-beam computed tomography (CT) scans (n=75) to the planning CT scans and adjusting the 3 rotational angles (pitch, roll, and yaw). Systematic and random setup errors were calculated. The dosimetric changes caused by rotational setup errors were quantified for both simulated and observed patient rotations. Dose distributions recalculated on the rotated CT scans were compared with the original planned doses. Translational corrections were simulated based on manual translational registration of the rotated images to the original CT scans. The correction efficacy was evaluated by comparing the recalculated plans with the original plans. Results: The systematic rotational setup errors were -0.06 Degree-Sign {+-} 0.68 Degree-Sign , -0.29 Degree-Sign {+-} 0.62 Degree-Sign , and -0.24 Degree-Sign {+-} 0.61 Degree-Sign ; the random setup errors were 0.80 Degree-Sign , 1.05 Degree-Sign , and 0.61 Degree-Sign for pitch, roll, and yaw, respectively. Analysis of CBCT images showed that 56.0%, 14.7%, and 1.3% of treated fractions had rotational errors of >1 Degree-Sign , >2 Degree-Sign , and >3 Degree-Sign , respectively, in any one of the rotational axes. Rotational simulations demonstrated that the reduction of gross tumor volume (GTV) coverage was <2% when rotation was <3 Degree-Sign . Recalculated plans using actual patient roll motions showed similar reduction (<2%) in GTV coverage. Translational corrections improved the GTV coverage to within 3% of the original values. For organs at risk (OAR), the dosimetric impact varied case by case. Conclusion: Actual rotational setup errors in SBRT for liver tumors are relatively small in magnitude and are unlikely to affect GTV coverage significantly. Translational corrections can be optimized to compensate for rotational setup errors. However, caution regarding possible dose increases to OAR needs to be exercised.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Density-functional errors in ionization potential with increasing system size

This work investigates the effects of molecular size on the accuracy of density-functional ionization potentials for a set of 28 hydrocarbons, including series of alkanes, alkenes, and oligoacenes. As the system size increases, delocalization error introduces a systematic underestimation of the ionization potential, which is rationalized by considering the fractional-charge behavior of the electronic energies. The computation of the ionization potential with many density-functional approximations is not size-extensive due to excessive delocalization of the incipient positive charge. While inclusion of exact exchange reduces the observed errors, system-specific tuning of long-range corrected functionals does not generally improve accuracy. These results emphasize that good performance of a functional for small molecules is not necessarily transferable to larger systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Error quantification and comparison of binary neutron star gravitational waveforms from numerical relativity codes

Future gravitational wave detections of merging binary neutron star systems have the possibility to tightly constrain the equation of state of dense nuclear matter. In order to extract such constraints, gravitational waveform models need to be calibrated to accurate numerical relativity simulations of the late inspiral and merger. In this work, we take an essential step toward classifying the error and potential systematics in current generation numerical relativity simulations of merging binary neutron stars. To this end, we perform a direct comparison of two codes (fil, spec), which differ in many aspects, including the numerical methods and discretizations used and equations solved. We find that despite these different approaches, the codes are—within current numerical resolution bounds—fully consistent, and broadly comparable in cost for a given accuracy level. Our results indicate that the error in the waveforms is primarily dominated by the hydrodynamic evolution, consistent with earlier findings in the literature. Finally, we also discuss current limitations and cost estimates for numerical relativity simulations to reach the accuracies required in the era of next-generation gravitational detectors.

gravitational waves↗

Zero-noise extrapolation for quantum-gate error mitigation with identity insertions

Quantum-gate errors are a significant challenge for achieving precision measurements on noisy intermediate-scale quantum (NISQ) computers. Here, this paper focuses on zero-noise extrapolation (ZNE), a technique that can be implemented on existing hardware, studying it in detail and proposing modifications to existing approaches. In particular, we consider identity insertion methods for amplifying noise because they are hardware agnostic. We build a mathematical formalism for studying existing ZNE techniques and show how higher order polynomial extrapolations can be used to systematically reduce depolarizing errors. Furthermore, we introduce a method for amplifying noise that uses far fewer gates than traditional methods. This approach is compared with existing methods for simulated quantum circuits. Comparable or smaller errors are possible with fewer gates, which illustrates the potential for empowering an entirely new class of moderate-depth circuits on near term hardware.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LiG Metrology, Correlated Error, and the Integrity of the Global Surface Air-Temperature Record

The published 95% uncertainty of the global surface air-temperature anomaly (GSATA) record through 1980 is impossibly less than the 2σ = ±0.25 °C lower limit of laboratory resolution of 1 °C/division liquid-in-glass (LiG) thermometers. The ~0.7 °C/century Joule-drift of lead- and soft-glass thermometer bulbs renders unreliable the entire historical air-temperature record through the 19th century. A circa 1900 Baudin meteorological spirit thermometer bulb exhibited intense Pb X-ray emission lines (10.55, 12.66, and 14.76 keV). Uncorrected LiG thermometer non-linearity leaves 1σ = ±0.27 °C uncertainty in land-surface air temperatures prior to 1981. The 2σ = ±0.43 °C from LiG resolution and non-linearity obscures most of the 20th century GSATA trend. Systematic sensor-measurement errors are highly pair-wise correlated, possibly across hundreds of km. Non-normal distributions of bucket and engine-intake difference SSTs disconfirm the assumption of random measurement error. Semivariogram analysis of ship SST measurements yields half the error difference mean, ±½Δε 1,2, not the error mean. Transfer-function adjustment following a change of land station air-temperature sensor eliminates measurement independence and forward-propagates the antecedent uncertainty. LiG resolution limits, non-linearity, and sensor field calibrations yield GSATA mean ±2σ RMS uncertainties of, 1900–1945, ±1.7 °C; 1946–1980, ±2.1 °C; 1981–2004, ±2.0 °C; and 2005–2010, ±1.6 °C. Finally, the 20th century (1900–1999) GSATA, 0.74 ± 1.94 °C, does not convey any information about rate or magnitude of temperature change.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-602: Patient-Specific Online Dose Verification Based On Transmission Detector Measurements

Purpose: Intensity modulated radiotherapy requires a comprehensive quality assurance program in general and ideally independent verification of dose delivery. Since conventional 2D detector arrays allow only pre-treatment verification, there is a debate concerning the need of online dose verification. This study presents the clinical performance, including dosimetric plan verification in 2D as well as in 3D and the error detection abilities of a new transmission detector (TD) for online dose verification of 6MV photon beam. Methods: To validate the dosimetric performance of the new device, dose reconstruction based on TD measurements were compared to a conventional pre-treatment verification method (reference) and treatment planning system (TPS) for 18 IMRT and VMAT treatment plans. Furthermore, dose reconstruction inside the patient based on TD read-out was evaluated by comparing various dose volume indices and 3D gamma evaluations against independent dose computation and TPS. To investigate the sensitivity of the new device, different types of systematic and random errors for leaf positions and linac output were introduced in IMRT treatment sequences. Results: The 2D gamma index evaluation of transmission detector based dose reconstruction showed an excellent agreement for all IMRT and VMAT plans compared to reference measurements (99.3±1.2)% and TPS (99.1±0.7)%. Good agreement was also obtained for 3D dose reconstruction based on TD read-out compared to dose computation (mean gamma value of PTV = 0.27±0.04). Only a minimal dose underestimation within the target volume was observed when analyzing DVH indices (<1%). Positional errors in leaf banks larger than 1mm and errors in linac output larger than 2% could clearly identified with the TD. Conclusion: Since 2D and 3D evaluations for all IMRT and VMAT treatment plans were in excellent agreement with reference measurements and dose computation, the new TD is suitable to qualify for routine treatment plan verification. Funding Support, Disclosures, and Conflict of Interest: COIs: Frank Lohr: Elekta: research grant, travel grants, teaching honoraria IBA: research grant, travel grants, teaching honoraria, advisory board C-Rad: board honoraria, travel grants Frederik Wenz: Elekta: research grant, teaching honoraria, consultant, advisory board Zeiss: research grant, teaching honoraria, patent Hansjoerg Wertz: Elekta: research grant, teaching honoraria IBA: research grant.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cosmological Constraints from the SDSS maxBCG Cluster Catalog

We use the abundance and weak lensing mass measurements of the SDSS maxBCG cluster catalog to simultaneously constrain cosmology and the richness-mass relation of the clusters. Assuming a flat {Lambda}CDM cosmology, we find {sigma}{sub 8}({Omega}{sub m}/0.25){sup 0.41} = 0.832 {+-} 0.033 after marginalization over all systematics. In common with previous studies, our error budget is dominated by systematic uncertainties, the primary two being the absolute mass scale of the weak lensing masses of the maxBCG clusters, and uncertainty in the scatter of the richness-mass relation. Our constraints are fully consistent with the WMAP five-year data, and in a joint analysis we find {sigma}{sub 8} = 0.807 {+-} 0.020 and {Omega}{sub m} = 0.265 {+-} 0.016, an improvement of nearly a factor of two relative to WMAP5 alone. Our results are also in excellent agreement with and comparable in precision to the latest cosmological constraints from X-ray cluster abundances. The remarkable consistency among these results demonstrates that cluster abundance constraints are not only tight but also robust, and highlight the power of optically-selected cluster samples to produce precision constraints on cosmological parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗