Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Effect of sample geometry on the phase boundary of a mesoscopic superconducting loop.

We studied the effect of sample geometry on the evolution of the superconducting state in nanoscale Nb circular and square loops by transport measurements. A multistage resistive transition with temperature is found for both samples, which is related to the effect of contact leads made from the same superconducting material. The H-T phase diagrams close to T{sub c0} show clear periodic oscillations on top of a parabolic background, i.e., Little-Parks effect. However, the amplitude of the oscillations decreases faster in the circular loop compared to the one in the square sample. Numerical simulations are conducted within the nonlinear Ginzburg-Landau theory to show the effect of sample geometry on the nucleation of superconductivity in superconducting loop structures.

36 MATERIALS SCIENCE↗

Long-term {alpha}- and spontaneous fission measurement of a Rf/Db sample chemically prepared in a {sup 48}Ca on {sup 243}Am experiment

Results from long-term measurements of a chemically separated Db/Rf sample prepared from the products of a {sup 48}Ca on {sup 243}Am irradiation are presented. The sample with the highest spontaneous fission activity out of eight samples produced in the course of chemical experiments performed in 2004 was selected for these measurements. We conclude that there is no evidence for SF-decay originating from heavy actinide isotopes in this sample. Hence, it is appropriate to assign the SF-events observed in this experiment to decay products of {sup 288}115.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterizing plasma conditions in radiatively heated solid-density samples with x-ray Thomson scattering

Here, we have developed an experimental platform to generate radiatively heated solid density samples for warm dense matter studies at the OMEGA laser facility. Cylindrical samples of boron and beryllium are isochorically heated by K- and L-shell emission from x-ray converter foils wrapped around the cylinders' radii. X-ray Thomson scattering (XRTS) measures the temperature and the ionization state of the samples as function of time. Temperatures approach 10 eV, and the ionization states are found to be Z B = 3 and Z Be = 2. Radiation hydrodynamics simulations were performed to confirm a homogeneous plasma state exists in the center of the sample for the duration of the experiment. Results from the study can be extended to improve understanding of radiative heating processes in the warm dense matter regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface characterization of Nb samples electropolished together with real superconducting rf accelerator cavities

Here, we report the results of surface characterizations of niobium (Nb) samples electropolished together with a single cell superconducting radio-frequency accelerator cavity. These witness samples were located in three regions of the cavity, namely at the equator, the iris and the beam-pipe. Auger electron spectroscopy (AES) was utilized to probe the chemical composition of the topmost four atomic layers. Scanning electron microscopy with energy dispersive X-ray for elemental analysis (SEM/EDX) was used to observe the surface topography and chemical composition at the micrometer scale. A few atomic layers of sulfur (S) were found covering the samples non-uniformly. Niobium oxide granules with a sharp geometry were observed on every sample. Some Nb-O granules appeared to also contain sulfur.

43 PARTICLE ACCELERATORS↗

A fully contained sample holder capable of electron-yield detection at soft X-ray energies

A holder has been developed that enables electron yield-detected soft X-ray spectroscopy of fully contained samples at low temperature. Crucially, this design uses elements of the sample containment to collect ejected electrons, removing the need to expose samples directly to the vacuum environment of the spectrometer. The design is modular and should be adaptable to a number of different endstation configurations, enabling spectroscopy of air-sensitive, radioactive and vacuum-sensitive (biological) samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Sampling on NISQ Devices: "Who’s the Fairest One of All?"

Modern NISQ devices are subject to a variety of biases and sources of noise that degrade the solution quality of computations carried out on these devices. A natural question that arises in the NISQ era, is how fairly do these devices sample ground state solutions. To this end, we run five fair sampling problems (each with at least three ground state solutions) that are based both on quantum annealing and, on the Grover Mixer, -QAOA algorithm for gate-based NISQ hardware. In particular, we use seven IBM Q devices, the Aspen-9 Rigetti device, the IonQ device, and three D-Wave quantum annealers. For each of the fair sampling problems, we measure the ground state probability, the relative fairness of the frequency of each ground state solution with respect to the other ground state solutions, and the aggregate error as given by each hardware provider. Overall, our results show that NISQ devices do not achieve fair sampling yet. Furthermore, we also observe differences in the software stack with a particular focus on compilation techniques that illustrate what work will still need to be done to achieve a seamless integration of frontend (i.e., quantum circuit description) and backend compilation.

Computer Science↗

Sampling in Long-Screened Wells: Issues, Misconceptions, and Solutions

The issues associated with long-screened wells (LSWs) (and open boreholes) at contaminated sites are well documented in the groundwater literature but are still not fully appreciated in practice. As established in seminal and review papers going back over three decades, the interpretation of sampling results from LSWs is challenging in the presence of vertical hydraulic gradients and borehole flow; furthermore, LSWs allow for vertical redistribution of contamination between aquifer layers. Acknowledgment of these issues has led to the development of new technologies and well designs to enable discrete-zone monitoring (DZM), yet LSWs remain common for many reasons, for example, as multipurpose wells, for geophysical logging, and (or) as legacy installations. Despite the literature on LSWs and despite the adoption of DZM at many sites, the use of LSWs persists and the challenges of interpreting sampling results from LSWs remain. In this issue paper, we provide a conceptual overview of the problems posed by LSWs and review existing literature and past work to improve the interpretation of sampling in LSWs. We draw on experience from previous studies at the Hanford Site in eastern WA, USA, and use synthetic examples to illustrate key concepts and challenges for interpretation. A recently published analytical modeling framework is used to develop illustrative synthetic examples and demonstrate a workflow for building scientific intuition to understand issues around interpreting samples from LSWs, which is critical to effective characterization and groundwater remediation at sites with LSWs.

54 ENVIRONMENTAL SCIENCES↗

Multiple stable isotope characterization as a forensic tool to distinguish acid scavenger samples

Acid scavengers are frequently used as stabilizer compounds in a variety of applications. When used to stabilize volatile compounds such as nerve agents, the lower volatility and higher stability of acid scavengers make them more persistent in a post-event forensic setting. We are employing compound-specific stable isotope analysis of the carbon, nitrogen, and hydrogen components of three acid scavenging compounds (N,N-diethylaniline, tributylamine, and triethylamine) as a tool for distinguishing between different samples of the stabilizers. Combined analysis of three stable isotopes in these samples improves the technique’s resolving potential, enhancing sample matching capabilities. The compound specific methods developed here can be applied to instances where these compounds are not pure, such as when mixed with an agent or when found as a residue at an event site. Effective sample matching can be crucial for linking compounds at multiple event sites or linking a supply inventory to an event.

08 HYDROGEN↗

The iron oxidation state of Ryugu samples

The Hayabusa2 mission sampled Ryugu, an asteroid that did not suffer extensive thermal metamorphism, and returned rocks to the Earth with no significant air exposure. It therefore offers a unique opportunity to study the redox state of carbonaceous Cb-type asteroids and evaluate the overall redox state of the most primitive rocks of the solar system. An analytical framework was developed to investigate the iron mineralogy and valence state in extraterrestrial material at the micron scale by combining x-ray diffraction, conventional Mössbauer (MS), and nuclear forward scattering (NFS) spectroscopies. An array of standard minerals was analyzed and cross-calibrated between MS and NFS. Then, MS and NFS spectra on three Ryugu grains were collected at the bulk and the micron scales. In Ryugu samples, iron is essentially accommodated in magnetite, clay minerals (serpentine–smectite), and sulfides. Only a single set of Mössbauer parameters was necessary to account for the entire variability observed in MS and NFS spectra, at all spatial scales investigated. These parameters therefore make up a fully consistent iron mineralogical model for the Ryugu samples. As far as MS and NFS spectroscopies are concerned, Ryugu grains are overall similar to each other and share most of their mineralogical features with CI-type chondrites. In detail however, no ferrihydrite is found in Ryugu particles even at the very sensitive scale of Mössbauer spectroscopy. The typical Fe 3+ /Fe tot of clay minerals is much lower than typical redox ratios measured in CI chondrites (Fe 3+ /Fe tot = 85%–90%). Furthermore, magnetite from Ryugu is stoichiometric with no significant maghemite component, whereas up to 12% of maghemite was previously identified in the Orgueil's so-called magnetite. These differences suggest that most CI meteorites suffered terrestrial alteration and that the preterrestrial composition of these carbon-rich samples was less oxidized than previously measured. However, it is not clear yet whether or not the parent bodies of CI chondrites were as reduced as Ryugu. Finally, the high spatial resolution of NFS allows to disentangle the redox state and the crystal chemistry of iron accommodated in serpentine and smectite. The most likely polytype of serpentine is lizardite, containing <35% of Fe 3+ , a fraction of which being tetrahedrally coordinated. Smectite is more oxidized (Fe 3+ /Fe tot > 65%) and mainly contains octahedral ferric iron. In conclusion, this finding implies that these clays formed from highly alkaline fluids and the spatial variability highlighted here may suggest a temporal evolution or a spatial variability of the nature of this fluid.

58 GEOSCIENCES↗

Simple effective conservative treatment of uncertainty from sparse samples of random functions

This paper examines the variability of predicted responses when multiple stress-strain curves (reflecting variability from replicate material tests) are propagated through a finite element model of a ductile steel can being slowly crushed. Over 140 response quantities of interest (including displacements, stresses, strains, and calculated measures of material damage) are tracked in the simulations. Each response quantity’s behavior varies according to the particular stress-strain curves used for the materials in the model. We desire to estimate response variability when only a few stress-strain curve samples are available from material testing. Propagation of just a few samples will usually result in significantly underestimated response uncertainty relative to propagation of a much larger population that adequately samples the presiding random-function source. A simple classical statistical method, Tolerance Intervals, is tested for effectively treating sparse stress-strain curve data. The method is found to perform well on the highly nonlinear input-to-output response mappings and non-standard response distributions in the can-crush problem. The results and discussion in this paper support a proposition that the method will apply similarly well for other sparsely sampled random variable or function data, whether from experiments or models. Finally, the simple Tolerance Interval method is also demonstrated to be very economical.

36 MATERIALS SCIENCE↗

Bridging the gap between IMRT and VMAT: Dense angularly sampled and sparse intensity modulated radiation therapy

Purpose: To propose an alternative radiation therapy (RT) planning and delivery scheme with optimal angular beam sampling and intrabeam modulation for improved dose distribution while maintaining high delivery efficiency. Methods: In the proposed approach, coined as dense angularly sampled and sparse intensity modulated RT (DASSIM-RT), a large number of beam angles are used to increase the angular sampling, leading to potentially more conformal dose distributions as compared to conventional IMRT. At the same time, intensity modulation of the incident beams is simplified to eliminate the dispensable segments, compensating the increase in delivery time caused by the increased number of beams and facilitating the plan delivery. In a sense, the proposed approach shifts and transforms, in an optimal fashion, some of the beam segments in conventional IMRT to the added beams. For newly available digital accelerators, the DASSIM-RT delivery can be made very efficient by concatenating the beams so that they can be delivered sequentially without operator's intervention. Different from VMAT, the level of intensity modulation in DASSIS-RT is field specific and optimized to meet the need of each beam direction. Three clinical cases (a head and neck (HN) case, a pancreas case, and a lung case) are used to evaluate the proposed RT scheme. DASSIM-RT, VMAT, and conventional IMRT plans are compared quantitatively in terms of the conformality index (CI) and delivery efficiency. Results: Plan quality improves generally with the number and intensity modulation of the incident beams. For a fixed number of beams or fixed level of intensity modulation, the improvement saturates after the intensity modulation or number of beams reaches to a certain level. An interplay between the two variables is observed and the saturation point depends on the values of both variables. For all the cases studied here, the CI of DASSIM-RT with 15 beams and 5 intensity levels (0.90, 0.79, and 0.84 for the HN, pancreas, and lung cases, respectively) is similar with that of conventional IMRT with seven beams and ten intensity levels (0.88, 0.79, and 0.83) and is higher than that of single-arc VMAT (0.75, 0.75, and 0.82). It is also found that the DASSIM-RT plans generally have better sparing of organs-at-risk than IMRT plans. It is estimated that the dose delivery time of DASSIM-RT with 15 beams and 5 intensity levels is about 4.5, 4.4, and 4.2 min for the HN, pancreas, and lung case, respectively, similar to that of IMRT plans with 7 beams and 10 intensity levels.Conclusion: DASSIS-RT bridges the gap between IMRT and VMAT and allows optimal sampling of angular space and intrabeam modulation, thus it provides improved conformity in dose distributions while maintaining high delivery efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Organ sample generator for expected treatment dose construction and adaptive inverse planning optimization

Purpose: To create an organ sample generator (OSG) for expected treatment dose construction and adaptive inverse planning optimization. The OSG generates random samples of organs of interest from a distribution obeying the patient specific organ variation probability density function (PDF) during the course of adaptive radiotherapy. Methods: Principle component analysis (PCA) and a time-varying least-squares regression (LSR) method were used on patient specific geometric variations of organs of interest manifested on multiple daily volumetric images obtained during the treatment course. The construction of the OSG includes the determination of eigenvectors of the organ variation using PCA, and the determination of the corresponding coefficients using time-varying LSR. The coefficients can be either random variables or random functions of the elapsed treatment days depending on the characteristics of organ variation as a stationary or a nonstationary random process. The LSR method with time-varying weighting parameters was applied to the precollected daily volumetric images to determine the function form of the coefficients. Eleven h and n cancer patients with 30 daily cone beam CT images each were included in the evaluation of the OSG. The evaluation was performed using a total of 18 organs of interest, including 15 organs at risk and 3 targets. Results: Geometric variations of organs of interest during h and n cancer radiotherapy can be represented using the first 3 {approx} 4 eigenvectors. These eigenvectors were variable during treatment, and need to be updated using new daily images obtained during the treatment course. The OSG generates random samples of organs of interest from the estimated organ variation PDF of the individual. The accuracy of the estimated PDF can be improved recursively using extra daily image feedback during the treatment course. The average deviations in the estimation of the mean and standard deviation of the organ variation PDF for h and n cancer radiotherapy were less than 2 and 1 mm, respectively, for most organs after the second week of treatment. After the first three weeks of treatment, the mean discrepancy of the dose estimation accuracy was within 1% for most of organs, the corresponding standard deviation was within 2.5% for parotids, the brain stem and the cochleae, and within 1% for other organs. Conclusions: A patient specific OSG is feasible and can be used to generate random samples of organs of interest for the expected treatment dose construction and adaptive inverse planning. The accuracy of the OSG can be improved continuously and recursively during the adaptive treatment course using daily volumetric image feedback.

60 APPLIED LIFE SCIENCES↗

SU-E-I-46: Sample-Size Dependence of Model Observers for Estimating Low-Contrast Detection Performance From CT Images

Purpose: Recently, task-based assessment of diagnostic CT systems has attracted much attention. Detection task performance can be estimated using human observers, or mathematical observer models. While most models are well established, considerable bias can be introduced when performance is estimated from a limited number of image samples. Thus, the purpose of this work was to assess the effect of sample size on bias and uncertainty of two channelized Hotelling observers and a template-matching observer. Methods: The image data used for this study consisted of 100 signal-present and 100 signal-absent regions-of-interest, which were extracted from CT slices. The experimental conditions included two signal sizes and five different x-ray beam current settings (mAs). Human observer performance for these images was determined in 2-alternative forced choice experiments. These data were provided by the Mayo clinic in Rochester, MN. Detection performance was estimated from three observer models, including channelized Hotelling observers (CHO) with Gabor or Laguerre-Gauss (LG) channels, and a template-matching observer (TM). Different sample sizes were generated by randomly selecting a subset of image pairs, (N=20,40,60,80). Observer performance was quantified as proportion of correct responses (PC). Bias was quantified as the relative difference of PC for 20 and 80 image pairs. Results: For n=100, all observer models predicted human performance across mAs and signal sizes. Bias was 23% for CHO (Gabor), 7% for CHO (LG), and 3% for TM. The relative standard deviation, σ(PC)/PC at N=20 was highest for the TM observer (11%) and lowest for the CHO (Gabor) observer (5%). Conclusion: In order to make image quality assessment feasible in the clinical practice, a statistically efficient observer model, that can predict performance from few samples, is needed. Our results identified two observer models that may be suited for this task.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney

Purpose: The radioligand {sup 11}C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of {sup 11}C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method in pigs with the goal of translation into human studies. Methods: The experimental animals were injected with [{sup 11}C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. Results: In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the subsequent phase of the ID-IF. The combined use of FBP and OS-EM resulted in reduced bias and noise. After performing all the necessary corrections, the areas under the curves (AUCs) of the AD-IF were close to that of the AD-IF (average AUC ratio =1 ± 0.08) during the early phase. When applied in a two-tissue-compartmental kinetic model, the average difference between the estimated model parameters from ID-IF and AD-IF was 10% which was within the error of the estimation method. Conclusions: The bias of radioligand concentration in the aorta from the OS-EM image reconstruction is significantly affected by radioligand uptake in the adjacent kidney and cannot be neglected for quantitative evaluation. With careful calibrations and corrections, the ID-IF derived from quantitative dynamic PET images can be used as the input function of the compartmental model to quantify the renal kinetics of {sup 11}C-KR31173 in experimental animals and the authors intend to evaluate this method in future human studies.

60 APPLIED LIFE SCIENCES↗

The Spectrum of Thermally Stimulated Surface Plasmon Polaritons of a Linear Sample

An analytical model of the spectrum of thermally stimulated surface plasmon polaritons (TSSPPs) coming to the edge of a linear conducting sample has been developed. It has been found that the spectrum of such TSSPPs obeys neither the Wien law nor the Stefan–Boltzmann law for thermal radiation. The maximum of this spectrum is shifted to the low-frequency region with respect to the spectrum of the absolutely black body, and the magnitude of the shift is proportional to the sample length. The plasmon nature of the intensity increment of thermal radiation from the edge of a plane face of a duralumin sample has been verified experimentally. It has been shown that the intensity and spectrum of this increment can be controlled both by the sample temperature and by the extension of the face.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The I-V characteristics of asymmetrically necked samples of high-resistivity silicon

The results of investigation of the I-V characteristics are presented for asymmetrically necked n-Si samples. It is established that the asymmetry of the I-V characteristic for the samples under investigation at the room and liquid-nitrogen temperatures in high electric fields is caused by the space-charge formation. At T = 78 K in the warm-electron region, the asymmetry of the I-V characteristic is caused by nonlocal relation between the electron mobility and the nonuniform electric-field intensity. It is found that the sample resistance at liquid-nitrogen temperature insignificantly increases after applying high electric-field pulses. The effect under observation is attributed to a decrease in the electron concentration in the necked section of the sample due to the redistribution of hot electrons between bulk and surface.

36 MATERIALS SCIENCE↗

Silicon with an increased content of monoatomic sulfur centers: Sample fabrication and optical spectroscopy

The effect of the high-temperature heating (at 1340 Degree-Sign C) of sulfur-doped silicon samples and their subsequent quenching is studied. The results of such a treatment are analyzed on the basis of Hall-effect data obtained in the temperature range T = 78-500 K. It is shown that the heating duration strongly affects the relative concentrations of different types of deep sulfur-related centers. At comparatively short heating durations of t = 2-10 min, the concentration of quasi-molecular S{sub 2} centers and S{sub X} complexes substantially decreases, whereas the density of monoatomic S{sub 1} centers grows. At the same time, the heating of a sample is accompanied by a monotonic decrease in the total concentration of electrically active sulfur over time. The results obtained make it possible to give recommendations concerning the optimal conditions for the fabrication of samples with a high concentration of S{sub 1} centers. The absorption spectra of the samples show that the method is promising for the observation of a number of quantum-optical effects involving deep S{sub 1} donors in silicon.

36 MATERIALS SCIENCE↗

Experimental Determination of the Radial Displacement Field in the Neck of Samples after a Tensile Test

This Letter presents the results of a study of the radial displacement fields arising upon stretching of cylindrical samples before their disintegration. The object of study was sv-07Kh16N6 stainless steel wire containing filiform defects oriented along the sample axis. Using X-ray tomography of the sample necks, the coordinates of the defect points in the sample are determined and the displacement field is recovered from them. The resulting dependence is represented by an approximate formula.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗