Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Review”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Patient-based radiographic exposure factor selection: a systematic review

Digital technology has wider exposure latitude and post-processing algorithms which can mask the evidence of underexposure and overexposure. Underexposure produces noisy, grainy images which can impede diagnosis and overexposure results in a greater radiation dose to the patient. These exposure errors can result from inaccurate adjustment of exposure factors in response to changes in patient thickness. This study aims to identify all published radiographic exposure adaptation systems which have been, or are being, used in general radiography and discuss their applicability to digital systems. Studies in EMBASE, MEDLINE, CINAHL and SCOPUS were systematically reviewed. Some of the search terms used were exposure adaptation, exposure selection, exposure technique, 25% rule, 15% rule, DuPont™ Bit System and radiography. A manual journal-specific search was also conducted in The Radiographer and Radiologic Technology. Studies were included if they demonstrated a system of altering exposure factors to compensate for variations in patients for general radiography. Studies were excluded if they focused on finding optimal exposures for an ‘average’ patient or focused on the relationship between exposure factors and dose. The database search uncovered 11 articles and the journal-specific search uncovered 13 articles discussing systems of exposure adaptation. They can be categorised as simple one-step guidelines, comprehensive charts and computer programs. Only two papers assessed the efficacy of exposure adjustment systems. No literature compares the efficacy of exposure adaptations system for film/screen radiography with digital radiography technology nor is there literature on a digital specific exposure adaptation system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of deep inspiration breath-hold techniques for the treatment of breast cancer

Radiation treatment to the left breast is associated with increased cardiac morbidity and mortality. The deep inspiration breath-hold technique (DIBH) can decrease radiation dose delivered to the heart and this may facilitate the treatment of the internal mammary chain nodes. The aim of this review is to critically analyse the literature available in relation to breath-hold methods, implementation, utilisation, patient compliance, planning methods and treatment verification of the DIBH technique. Despite variation in the literature regarding the DIBH delivery method, patient coaching, visual feedback mechanisms and treatment verification, all methods of DIBH delivery reduce radiation dose to the heart. Further research is required to determine optimum protocols for patient training and treatment verification to ensure the technique is delivered successfully.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

What the radiologist needs to know: the role of preoperative computed tomography in selection of operative approach for adrenalectomy and review of operative techniques

Adrenalectomy is the standard of care for management of many adrenal tumor types and, in the United States alone, approximately 6000 adrenal surgeries are performed annually. Two general approaches to adrenalectomy have been described; (1) the open approach, in which a diseased adrenal is removed through a large (10–20 cm) abdominal wall incision, and (2) the minimally invasive approach, in which laparoscopy is used to excise the gland through incisions generally no longer than 1–2 cm. Given these disparate technique options, clear preoperative characterization of those specific disease features that inform selection of adrenalectomy approach is critically important to the surgeon. Because most of these features are directly assessed via preoperative abdominal imaging, in particular computed tomography (CT) scanning, a clear mutual understanding among surgeons and radiologists of those adrenal tumor features impacting operative approach selection is vital for planning adrenal surgery. In this context, we review the preoperative CT imaging features that specifically inform adrenalectomy approach selection, provide illustrative examples from our institution’s imaging and surgical archives, and provide a stepwise guide to both the open and laparoscopic adrenalectomy approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Incomplete tumor capsule on preoperative imaging reveals microvascular invasion in hepatocellular carcinoma: a systematic review and meta-analysis

Purpose: Microvascular invasion (MVI), which is difficult to diagnose before surgery, is a major factor affecting postoperative recurrence in patients with hepatocellular carcinoma (HCC). The relationship between the radiological tumor capsule and MVI is controversial. This study aimed to evaluate the association between the tumor capsule and MVI. Methods: We searched Medline (by PubMed) and Embase (by OvidSP). Two review authors independently screened titles and abstracts, selected studies about MVI prediction with radiologic tumor capsule and studies with enough data for extracted, assessed the methodological quality and collected data. Summary results were presented as the diagnostic odds ratio (DOR), sensitivity, specificity, and 95% confidence interval. Results: Fifteen studies with 2038 patients were included; fourteen studies, including 1331 patients, with no significant heterogeneity indicated no relationship between absent tumor capsule and MVI [DOR = 0.90 (0.64, 1.26)]. Six studies, including 541 patients, with no significant heterogeneity showed incomplete capsule could be used to predict MVI of HCC preoperatively [DOR = 1.85 (1.13, 3.04)]. The overall sensitivity and specificity estimate were 0.50 (0.37, 0.64) and 0.64 (0.53, 0.74), respectively. Eight studies, including 1349 patients, with highly significant heterogeneity revealed that complete capsule could be a protective factor for MVI [DOR = 1.97 (1.01, 3.86)]. Conclusions: For MVI of HCC, incomplete tumor capsule is a risk factor, while a complete tumor capsule might be a protective factor. However, absent capsule doesn’t show significant relationship with MVI. This might be due to combination of the risk and protective effects of present capsule in MVI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Embolization Before Liver Resection: A Systematic Review

This is a review of literature on the indications, technique, and outcome of portal vein embolization (PVE). A systematic literature search on outcome of PVE from 1990 to 2011 was performed in Medline, Cochrane, and Embase databases. Forty-four articles were selected, including 1,791 patients with a mean age of 61 {+-} 4.1 years. Overall technical success rate was 99.3 %. The mean hypertrophy rate of the FRL after PVE was 37.9 {+-} 0.1 %. In 70 patients (3.9 %), surgery was not performed because of failure of PVE (clinical success rate 96.1 %). In 51 patients (2.8 %), the hypertrophy response was insufficient to perform liver resection. In the other 17 cases, 12 did not technically succeed (0.7 %) and 7 caused a complication leading to unresectability (0.4 %). In 6.1 %, resection was cancelled because of local tumor progression after PVE. Major complications were seen in 2.5 %, and the mortality rate was 0.1 %. A head-to-head comparison shows a negative effect of liver cirrhosis on hypertrophy response. The use of n-butyl cyanoacrylate seems to have a greater effect on hypertrophy, but the difference with other embolization materials did not reach statistical significance. No difference in regeneration is seen in patients with cholestasis or chemotherapy. Preoperative PVE has a high technical and clinical success rate. Liver cirrhosis has a negative effect on regeneration, but cholestasis and chemotherapy do not seem to have an influence on the hypertrophy response. The use of n-butyl cyanoacrylate may result in a greater hypertrophy response compared with other embolization materials used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of Interventional Radiology in the Management of Chylothorax: A Review of the Current Management of High Output Chylothorax

Chylothorax is an uncommon type of pleural effusion whose etiology may be classified as traumatic or nontraumatic. Low-output chylothoraces usually respond well to conservative management, whereas high-output chylothoraces are more likely to require surgical or interventional treatment. Conservative management focuses on alleviation of symptoms, replacement of fluid and nutrient losses, and reduction of chyle output to facilitate spontaneous healing. Surgical management can be technically difficult due to the high incidence of variant anatomy and the high-risk patient population. Percutaneous treatments have rapidly developed and evolved during the past 14 years to represent a minimally invasive treatment compared with the more invasive nature of surgery. Percutaneous therapies provide a range of treatment options despite difficult or variant anatomy, with a reported high success rate coupled with low morbidity and mortality. This article is a review of etiology, diagnosis, and treatment of chylothorax, with a focus on interventional management techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of 3D Rotational Angiography on Liver Embolization Procedures: Review of Technique and Applications

In the last years, the interest into interventional applications of C-arm cone-beam CT (CBCT) progressively raised, widening its clinical application from the original field of interventional neuroradiology to the field of peripheral procedures. Liver embolization procedures, due to their complexity and potential treatment-related life-threatening complications, represent one of the main clinical applications of this novel angiographic technique. CBCT has been demonstrated to render procedures safer and technically easier, and to predict outcome as well as to avoid major complications in different treatment scenarios (trans-arterial embolization, trans-arterial chemoembolization, selective internal radiation therapy, percutaneous portal vein embolization). This review summarizes all technical, dosimetric and procedural aspects of CBCT techniques, underlying all its potential clinical advantages in the field of liver embolization procedures. Moreover, the paper provides all the instructions to obtain the best diagnostic performance out of this novel angiographic technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Refractory Hepatic Encephalopathy Complication of Transjugular Intrahepatic Portosystemic Shunt (TIPS): Comprehensive Review and Clinical Practice Algorithm

Transjugular intrahepatic portosystemic shunt (TIPS) has evolved as an effective intervention for treatment of complications of portal hypertension. The use of polytetrafluoroethylene-covered stents have improved the patency of the shunts and diminished the incidence of TIPS dysfunction. However, TIPS-related refractory hepatic encephalopathy (rHE) poses a significant challenge. Approximately 3–7 % of patients with TIPS develop rHE. Refractory hepatic encephalopathy is defined as a recurrent or persistent encephalopathy despite appropriate medical treatment. Hepatic encephalopathy can be an extremely debilitating complication that profoundly affects quality of life. The approach to management of patients with rHE is complex and typically requires collaboration between different specialties. Liver transplantation is the ultimate treatment for rHE; however, the ongoing shortage of organ donation markedly limits this treatment option. Alternative therapies such as shunt occlusion or reduction can control symptoms and serve as a ‘bridge’ therapy to liver transplantation. Therefore, interventional radiologists play a key role in the management of these patients by offering a variety of endovascular techniques. The purpose of this review is to highlight some of these endovascular techniques and to develop a therapeutic algorithm that can be applied in clinical practice for the management of rHE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-Induced Cataractogenesis: A Critical Literature Review for the Interventional Radiologist

Extensive research supports an association between radiation exposure and cataractogenesis. New data suggests that radiation-induced cataracts may form stochastically, without a threshold and at low radiation doses. We first review data linking cataractogenesis with interventional work. We then analyze the lens dose typical of various procedures, factors modulating dose, and predicted annual dosages. We conclude by critically evaluating the literature describing techniques for lens protection, finding that leaded eyeglasses may offer inadequate protection and exploring the available data on alternative strategies for cataract prevention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of the Clinical Evidence for the Use of DEBIRI in the Treatment of Colorectal Metastatic Disease

Colorectal cancer is a common malignancy that most commonly metastasizes to the liver. There has been considerable effort in developing new treatment options for these patients. One method that has been developed for the treatment of colorectal metastases to the liver is irinotecan-loaded drug-eluting bead (DEBIRI) embolization. This article reviews the current literature on DEBIRI and discusses the state of current knowledge and possible areas of future investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fusion Imaging and Virtual Navigation to Guide Percutaneous Thermal Ablation of Hepatocellular Carcinoma: A Review of the Literature

As medical imaging advancements have improved the detectability of hepatocellular carcinoma (HCC) in early stages, the approach to percutaneous thermal ablation for curative treatment has concomitantly advanced. Although many centers are adopting cross-sectional imaging to guide percutaneous ablation, the majority of procedures are still performed under ultrasound (US) guidance worldwide. Challenges to ultrasound guidance may present due to relatively poor resolution particularly with small or isoechoic lesions, or due to intervening structures such as the bowel or diaphragm that obstruct lesional visualization. Fusion imaging (FI) systems have been employed to address these challenges. By merging or synchronizing the real-time images from US with a previously obtained cross-sectional study, FI mitigates the inherent limitations of each individual imaging modality and expands procedural feasibility and technical outcomes. This manuscript reviews the current literature on the use of FI during percutaneous thermal ablation of HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Assessment of a Novel Touchless Interface for Intraprocedural Imaging Review

Purpose: To examine the feasibility of a novel technology platform that enables real-time touchless interaction with radiology images in both a simulated and an actual clinical setting. Materials and Methods: This platform offers three different modes for image interaction. The gesture recognition mode uses a depth camera to detect the user’s hand gestures which are translated to image manipulation commands. The light projection mode uses the same camera to detect finger point-and-tap movements above the icons which are projected on a surface to activate the commands. The capacitive sensing mode is enabled by a handheld, portable device, over which finger movements are detected by capacitive sensors to control the image review. Following initial feedback, light projection and capacitive sensing modes were selected for further testing by comparing with the conventional mode of image interaction in time trials for performing a series of standardized image manipulation tasks. Finally, the usability of the technology platform was examined in actual clinical procedures. Results: The light projection and the capacitive sensing modes were evaluated in the time trials and exhibited 60% and 71% reduction in time, respectively, relative to the control mode (p < 0.001). Clinical feasibility for this platform was demonstrated in three actual interventional radiology cases. Conclusion: Accessing, navigating, and extracting relevant information from patient images intraprocedurally are cumbersome and time-consuming tasks that affect safety, efficiency, and decision-making during image-guided procedures. This study demonstrated that the novel technology addressed this issue by allowing touchless interaction with these images in the sterile field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of mineral dissolution at the pore scale with evolving fluid-solid interfaces: review of approaches and benchmark problem set

This manuscript presents a benchmark problem for the simulation of single-phase flow, reactive transport, and solid geometry evolution at the pore scale. The problem is organized in three parts that focus on specific aspects: flow and reactive transport (part I), dissolution-driven geometry evolution in two dimensions (part II), and an experimental validation of three-dimensional dissolution-driven geometry evolution (part III). Five codes are used to obtain the solution to this benchmark problem, including Chombo-Crunch, OpenFOAM-DBS, a lattice Boltzman code, Vortex, and dissolFoam. These codes cover a good portion of the wide range of approaches typically employed for solving pore-scale problems in the literature, including discretization methods, characterization of the fluid-solid interfaces, and methods to move these interfaces as a result of fluid-solid reactions. A short review of these approaches is given in relation to selected published studies. Results from the simulations performed by the five codes show remarkable agreement both quantitatively--based on upscaled parameters such as surface area, solid volume, and effective reaction rate--and qualitatively--based on comparisons of shape evolution. This outcome is especially notable given the disparity of approaches used by the codes. Therefore, these results establish a strong benchmark for the validation and testing of pore-scale codes developed for the simulation of flow and reactive transport with evolving geometries. They also underscore the significant advances seen in the last decade in tools and approaches for simulating this type of problem.

58 GEOSCIENCES↗

A Review on Biodegradable Polymeric Materials Striving Towards the Attainment of Green Environment

Polymers are a chain of repeating monomers that can be either non-biodegradable or biodegradable with technical properties for a wide range of applications. The present scenario drives industries to develop new and eco-friendly materials to replace non-biodegradable materials to attain a clean and green environment. Significant research work has been carried out on the development of biocomposites based on biodegradable polymers and natural fibers. The review article addresses the wide range of biodegradable composites that are capable of undergoing degradation by various routes. Our main emphasis has been on the preparation and characterization of biocomposites, using various biodegradable polymers and natural fibers for wide applications like biomedical, packaging, aerospace, agriculture etc. It is clear that blending of reinforcing fibers and fillers with biodegradable polymers significantly enhanced the physical, chemical, biological, mechanical, thermal and biodegradation properties of the base matrix.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Review of Magneto-Elastic Interaction and Its Theoretical Descriptions in Type-II Superconductors

It is well known that the interaction between defect-induced strain field and vortex lattice (VL) gives rise to vortex pinning behaviors. Likewise, magneto-elastic (ME) interaction is caused by the difference between specific volumes of normal phase and superconducting (SC) phase. Acting as inhomogeneous strain sources, the normal-state vortex cores produce local deformation in the surrounding SC matter and thus affect VL energy. ME interaction belongs to the fundamental physics of interdependences between vortex matter and crystal lattice. The review starts with the effects of ME interaction on magnetization, vortex morphology and intervortex interaction. In Sect. 2, theoretical descriptions of ME interaction are classified in terms of different simplifications. The core ideas and outstanding results of these theories are given. It is followed by Sect. 3, where the correlation and difference between ME and pinning interaction are outlined. Although pinning differs from ME interaction in their formation mechanisms, the pinning interaction is established upon the vortex-induced strain field from Ginzburg-Landau (GL) viewpoint. Section 4 goes further with the GL treatment for solving ME and pinning problem; the general thoughts and steps can be found in this section. The last section gives some outlooks which involve pressure dependence of T{sub c} and anisotropy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sampling Density in Regional Exploration and Environmental Geochemical Studies: A Review

A variety of factors contribute to the proper and efficient evaluation of geochemical programs including sampling medium, sample size and sample fraction, sampling density, digestion procedure, and analytical techniques. Among the aforementioned factors, sampling density is of great importance, affecting project ability to detect anomalous sites, which are either economically viable or environmentally hazardous. It is quite critical to have a sufficient number of samples to delineate geochemical anomalies or baselines and to reveal the relative variations in elemental concentrations in a study area. The resolution of the subsequent maps obtained by sampling greatly depends on sampling density. While a large number of samples may generate redundant data, a small number of samples smooth out the patterns and may completely miss anomalies. This review provides a platform for applied geochemists who desire to design a sampling scheme for a regional geochemical program and do not have the financial resources to perform an orientation survey, which will give them the necessary information for designing, according to project objectives, a cost-effective regional geochemical survey for their study area. It is advisable to integrate during the desktop study all available information, such as geological, structural, geophysical, remote sensing data and topographical data by using different data fusion algorithms to arrive at a sampling density fit-for-purpose of the target area. This in turn facilitates an effective spatial positioning of sample locations. Quantitative analyses of the efficiency of different sampling densities for delineating geochemical patterns have not been well documented, warranting more attention and research.

58 GEOSCIENCES↗

Unconventional Energy Resources: 2017 Review

This review presents six summaries for energy resource commodities including coal and unconventional resources, and an analysis of energy economics and technology for the different commodities, as prepared by the Energy Minerals Division of the American Association of Petroleum Geologists. Unconventional energy resources, as defined in this report, are those energy resources that do not occur in discrete oil or gas reservoirs held within stratigraphic and/or structural traps of sedimentary basins. As defined, such energy resources include coal, coalbed methane (CBM), tight gas and liquids, bitumen and heavy oil, uranium (U), thorium (Th), and associated rare earth elements of interest to industry, and geothermal. Current North American and global research and development activities are summarized for each of the unconventional energy resource commodities in separate topical sections of this report.

58 GEOSCIENCES↗