Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Repeatability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Gravitational production of completely dark photons with nonminimal couplings to gravity

Dark photons are a theorized massive spin-1 particle which can be produced via various mechanisms, including cosmological gravitational particle production (GPP) in the early universe. In this work, we extend previous results for GPP of dark photons to include nonminimal couplings to gravity. We find that nonminimal couplings can induce a ghost instability or lead to runaway particle production at high momentum and discuss the constraints on the parameter space such that the theory is free of instabilities. Within the instability-free regime we numerically calculate the particle production and find that the inclusion of nonminimal couplings can lead to an enhancement of the particle number. As a result, GPP of nonminimally coupled dark photons can open the parameter space for production of a cosmological relevant relic density (constituting all or part of the dark matter) as compared to the minimally-coupled theory. These results are independent of the choice of inflation model, which we demonstrate by repeating the analysis for a class of rapid-turn multi-field inflation models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Lund jet plane

Lund diagrams, a theoretical representation of the phase space within jets, have long been used in discussing parton showers and resummations. We point out that they can be created for individual jets through repeated Cambridge/Aachen declustering, providing a powerful visual representation of the radiation within any given jet. Concentrating here on the primary Lund plane, we outline some of its analytical properties, highlight its scope for constraining Monte Carlo simulations and comment on its relation with existing observables such as the zg variable and the iterated soft-drop multiplicity. We then examine its use for boosted electroweak boson tagging at high momenta. It provides good performance when used as an input to machine learning. Much of this performance can be reproduced also within a transparent log-likelihood method, whose underlying assumption is that different regions of the primary Lund plane are largely decorrelated. This suggests a potential for unique insight and experimental validation of the features being used by machine-learning approaches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantifying the Potential of Argon Detection Capabilities for Nuclear Explosion Monitoring

Abstract Current noble gas detection systems for nuclear explosion monitoring are based on the detection of four radioxenon isotopes—Xe-131m, -133, -133m and -135. The data provided by radioxenon detection could be enhanced by other radionuclide signatures such as Ar-37. Activation of Ca-40 in rock by neutrons produces Ar-37, and monitoring for this additional nuclide could help distinguish detections of nuclear explosions from background sources, such as medical isotope production. This work studies the capabilities of a hypothetical argon detection network. A 10 kt explosion was modeled using MCNP and SCALE to determine the inventory of Ar-37 created in a representative granite rock layer, assuming either 0.1, 1 or 10% of the total inventory was released. The Ar-37 inventory was combined with atmospheric transport data from HYSPLIT compiled in a previous study, along with the detection limits of standard Ar-37 detection systems, to determine how many hypothetical monitoring stations would detect Ar-37 from an explosion. This method was repeated for 365 HYSPLIT data sets to create a year’s worth of hypothetical explosions, releases, and detections. The study quantified the average number of detections per release, the number of stations detecting Ar-37, and the possibility of detecting Ar-37 in coincidence with xenon.

37Ar↗

Identification of a QTL region for tomato brown rugose fruit virus resistance in Solanum pimpinellifolium

Abstract Tomato (Solanum lycopersicumL.), one of the most widely grown vegetables in the world, has been seriously impacted in the past decade by the emerging tomato brown rugose fruit virus (ToBRFV). ToBRFV is a seed-borne tobamovirus, with ability to overcome the commonly usedTm-2 2 resistance gene in tomato. The objective of this study was to conduct quantitative trait locus (QTL) mapping and identify single-nucleotide polymorphism (SNP) markers associated with ToBRFV resistance in tomato. Two F 2 populations were used for QTL mapping: One derived from a cross betweenS. pimpinellifoliumUSVL333 (PI 390718) × USVL332 (PI 390717) and another from ‘Moneymaker’ × USVL332 (PI 390717), with population sizes of 195 and 79 plants, respectively. The resistance trait was derived from theS. pimpinellifoliumaccession USVL332 (PI 390717). A major QTL for ToBRFV resistance was identified on chromosome 11 (SL4.0ch11), with the peak located at approximately 46.84 Mbp. This QTL spans a 22-kb interval between 46,825,788 bp and 46,847,421 bp, as determined through both genome-wide association study (GWAS) and QTL linkage mapping. Three SNP markers, SL4.0ch11_46825788, SL4.0ch11_46847421, and SL4.0ch11_46850215, demonstrated the most significant association with high LOD values (LOD = 13 in the Blink model) in GWAS analysis. In this genomic region, two disease resistance gene analogs, Solyc11g062150 (TIR-NBS-LRR resistance protein, Toll-Interleukin receptor) and Solyc11g062180 (disease resistance protein, leucine-rich repeat), were identified, which may serve as candidates for ToBRFV resistance. The QTL identified in this study could be valuable for plant breeders in facilitating tomato breeding with ToBRFV resistance.

Agriculture↗

Ti and Zn Content in Moss Shoots After Exposure to TiO{sub 2} and ZnO Nanoparticles: Biomonitoring Possibilities

To assess the uptake of nanoparticles by moss shoots and the possibility of biomonitoring the moss of nanoparticle pollution, two moss species frequently used in biomonitoring surveys [Hylocomium splendens (Hedw.) Schimp. and Pleurozium schreberi (Brid.) Mitt.] were repeatedly exposed to known concentrations of either nano-TiO{sub 2} or nano-ZnO suspensions. The interspecies differences were assessed by exposing both the species to 1 g L{sup −1} nano-ZnO suspension, H. splendens samples were also exposed to either 0.1 g L{sup −1} or 1 g L{sup −1} suspension of nano TiO{sub 2}. The exposed samples were analysed for Zn or Ti content using Inductively Coupled Plasma-Atomic Emission Spectroscopy. Both species showed a similar accumulation pattern, H. splendens being a slightly better accumulator. The washing suggests that Ti successfully penetrated the interior of the gametophyte. Since the relationship between the exposure and accumulation is linear, moss biomonitoring is, hereby, considered to be a viable, novel technique in nanoparticle pollution assessment.

54 ENVIRONMENTAL SCIENCES↗

Combined shape and topology optimization for minimization of maximal von Mises stress

Here, this work shows that a combined shape and topology optimization method can produce optimal 2D designs with minimal stress subject to a volume constraint. The method represents the surface explicitly and discretizes the domain into a simplicial complex which adapts both structural shape and topology. By performing repeated topology and shape optimizations and adaptive mesh updates, we can minimize the maximum von Mises stress using the p-norm stress measure with p-values as high as 30, provided that the stress is calculated with sufficient accuracy.

42 ENGINEERING↗

Numerical study of multiscale compaction-initiated detonation

A multiscale model of heterogeneous condensed-phase explosives is examined computationally to determine the course of transient events following the application of a piston-driven stimulus. The model is a modified version of that introduced by Gonthier (Combust Sci Technol 175(9):1679–1709, 2003. https://doi.org/10.1080/00102200302373) in which the explosive is treated as a porous, compacting medium at the macro-scale and a collection of closely packed spherical grains capable of undergoing reaction and diffusive heat transfer at the meso-scale. A separate continuum description is ascribed to each scale, and the two scales are coupled together in an energetically consistent manner. Following piston-induced compaction, localized energy deposition at the sites of intergranular contact creates hot spots where reaction begins preferentially. Reaction progress at the macro-scale is determined by the spatial average of that at the grain scale. A parametric study shows that combustion at the macro-scale produces an unsteady detonation with a cyclical character, in which the lead shock loses strength and is overtaken by a stronger secondary shock generated in the partially reacted material behind it. Finally, the secondary shock in turn becomes the new lead shock and the process repeats itself.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Caffeine improves reaction time, vigilance and logical reasoning during extended periods with restricted opportunities for sleep

Rationale Various occupational groups are required to maintain optimal physical and cognitive function during overnight periods of wakefulness, often with less than optimal sleep. Strategies are required to help mitigate the impairments in cognitive function to help sustain workplace safety and productivity. Objectives To test the effectiveness of repeated 200 mg doses of caffeine on cognitive function and live-fire marksmanship with soldiers during three successive nights of sustained wakefulness followed by 4-h afternoon sleep periods. Methods Twenty Special Forces personnel (28.6±4.7 years, 177.6±7.5 cm and 81.2±8.0 kg) were randomly assigned to receive four 200-mg doses of caffeine (n=10) or placebo (n= 10) during the late evening and early morning hours during three successive days. An afternoon 4-h sleep period followed. The psychomotor (PVT) and field (FVT) vigilance, logical reasoning (LRT) tests and a vigilance monitor assessed cognitive function throughout the study. Live-fire marksmanship requiring friend–foe discrimination was assessed. Results Caffeine maintained speed on the PVT (p<0.02), improved detection of events during FVT (p<0.001), increased number of correct responses to stimuli as assessed by the vigilance monitor (p<0.001) and increased response speed during the LRT (p<0.001) throughout the three overnight testing periods. Live-fire marksmanship was not altered by caffeine. Conclusions A total daily dose of 800 mg caffeine during successive overnight periods of wakefulness is an effective strategy to maintain cognitive function when optimal sleep periods during the day are not available.

60 APPLIED LIFE SCIENCES↗

Single-Shot Decoding of Good Quantum LDPC Codes

Abstract Quantum Tanner codes constitute a family of quantum low-density parity-check codes with good parameters, i.e., constant encoding rate and relative distance. In this article, we prove that quantum Tanner codes also facilitate single-shot quantum error correction (QEC) of adversarial noise, where one measurement round (consisting of constant-weight parity checks) suffices to perform reliable QEC even in the presence of measurement errors. We establish this result for both the sequential and parallel decoding algorithms introduced by Leverrier and Zémor. Furthermore, we show that in order to suppress errors over multiple repeated rounds of QEC, it suffices to run the parallel decoding algorithm for constant time in each round. Combined with good code parameters, the resulting constant-time overhead of QEC and robustness to (possibly time-correlated) adversarial noise make quantum Tanner codes alluring from the perspective of quantum fault-tolerant protocols.

97 MATHEMATICS AND COMPUTING↗

Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*)

Purpose: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). Methods: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1–5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen’s κ test. Results: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). Conclusions: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precision and accuracy of magnetic resonance imaging for lobar classification of benign prostatic hyperplasia

Purpose: To validate the application of a magnetic resonance imaging (MRI)-based lobar classification of benign prostatic hyperplasia (BPH) for use in research and clinical management. Methods: Two radiologists with 5 and 11 years post-fellowship experience were trained in the lobar classification of BPH using an internally developed atlas of prostate anatomy with example MRI images edited by a third senior radiologist designated as the “administrator” of the study. A study population of 140 patients referred to a tertiary academic medical center with known or suspected prostate cancer was selected by the administrator to test the interrater reliability (IRR; precision) of the classification as well as accuracy of the two readers compared to the administrator as the “gold” standard. The intrarater reliability of repeat readings of the administrator was also examined. Percentage of agreement, proportion of agreement, and Cohen’s κ were applied. This was a retrospective IRB-approved study. Results: IRR (precision) between the two interpreting radiologists was 64% agreement, corresponding to unweighted κ of 0.52. Composite proportion of agreement across all BPH types (categories) for interpreting radiologists was 0.67. Observer accuracy was 62% agreement, unweighted κ 0.49, for observer 1 and 67%, unweighted κ 0.58, for observer 2. Intrarater reliability for the administrator was 87% agreement, unweighted κ 0.81 with composite proportion of agreement across all categories of 0.87. Conclusions: MRI lobar classification of BPH is a reproducible and reliable tool for research and clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of a Hemorrhoid Following 18 Hours of Life-Threatening Bleeding

Hemorrhoids usually do not pose diagnostic difficulties and they rarely cause massive bleeding. We report a case of massive rectal bleeding over 18 h needing 22 U blood transfusion treated by superselective transcatheter coil embolization 12 h following operative treatment performed in a different hospital. Diagnostic angiography with a view to superselective embolization, following failure of sigmoidoscopy to localize and treat the cause of hemorrhage, might act as a life-saving treatment in massive rectal bleeding, obviating the need for repeated endoscopy or emergency surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Chemoembolization (TACE) for Inoperable Intrahepatic Cholangiocarcinoma

The aim of this retrospective study was to determine the safety and efficacy of chemoembolization (TACE) as palliative treatment for patients with unresectable intrahepatic cholangiocarcinoma (CCA) and to compare the results with those in the literature. Fifteen patients with histology-proven CCA (5 men, 10 women) had received palliative treatment with TACE over a 6-year period. The treatment protocol comprised repeated TACE at a minimum of 8-week intervals. TACE was performed with a mixture of 10 ml Lipiodol and 10 mg mitomycin C injected into the tumor-supplying vessels. Follow-up investigations after 8-10 weeks comprised contrast-enhanced multislice spiral CT and laboratory control. Statistical evaluation included survival analysis using the Kaplan-Meier method. During the investigation period 58 TACEs (3.9 {+-} 3.8; 1-15) were performed in 15 patients. Mean tumor size was 10.8 {+-} 4.6 cm (range, 2.0-18.0 cm). Unifocal tumor disease was diagnosed in eight patients, and multifocal disease in seven. Mean survival was 21.1 months (95% CI, 9.4-32.5 months). At the end of the investigation period 3 patients are still alive, and 12 patients have died. The 1-, 2-, and 3-year survival rate was 51.3%, 27.5%, and 27.5% respectively. According to RECIST criteria interim best response to therapy was stable disease in 9 of 15 patients, a partial response in 1 of 15 patients, and tumor progression in 4 of 15 patients. No deaths and no acute liver failure occurred under TACE therapy. Major complications were observed in two patients, comprising anaphylactic shock owing to contrast medium administration in one and gastric ulceration due to lipiodol displacement in the second patient. These results demonstrate that TACE is a safe procedure with a moderate number of complications for patients suffering from inoperable CCA. According to recently published data on i.v. chemotherapy we suggest that TACE might be able to prolong survival in selected patients who would succumb under other palliative treatment modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes After Unilateral Uterine Artery Embolization: A Retrospective Review

Purpose. Bilateral uterine artery embolization (UAE) is considered necessary to provide effective treatment for symptomatic uterine fibroids. Occasionally, only unilateral embolization is performed, and this study evaluates these outcomes. Materials and Methods. As part of a prospective observational study of more than 1600 patients treated with UAE since 1996, there have been 48 patients in whom unilateral embolization has been performed. This study retrospectively reviews clinical response as assessed by our standard questionnaire and radiological response assessed by either magnetic resonance imaging or ultrasound. Results. Two principal groups emerged: the largest, where only the dominant unilateral arterial supply was electively embolized (30 patients); and the second, where there was technical failure to catheterize the second uterine artery as a result of anatomical constraints (12 patients). Favorable clinical response with a reduction in menorrhagia at 1 year was seen in 85.7% (18/21) of those patients with a dominant arterial supply to the fibroid(s). In contrast, in those patients where there was technical failure to embolize one uterine artery, there was a high rate of clinical failure requiring further intervention in 58.3% (7/12). Comparison of the technical failure group with the dominant uterine artery group demonstrated a statistically significant (Fisher's exact test) difference in the proportion of patients with evidence of persistent fibroid vascularity (p < 0.001) and requiring repeat intervention (p < 0.01). Conclusion. We conclude that unilateral UAE can achieve a positive clinical result in the group of patients where there is a dominant unilateral artery supplying the fibroid(s), in contrast to the poor results seen following technical failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Primary Cutting Balloon Angioplasty for Treatment of Venous Stenoses in Native Hemodialysis Fistulas: Long-Term Results from Three Centers

Aim. To evaluate the technical success and patency rates following primary cutting balloon angioplasty for venous stenoses in native dialysis fistulas. Methods. Forty-one patients (26 men, 15 women; age range 26-82 years, average age 59 years) underwent 50 (repeat procedures in 9 patients) primary cutting balloon (PCB) angioplasty procedures in three institutions by three primary operators. The indication was primary stenosis in 21 patients, recurrent lesions in 15, and immature fistulas in 5. A PCB was used alone in 17 cases, but was followed by a larger standard balloon in 33 cases. Follow-up included ultrasound, flow analysis and urea reduction ratio, and ranged from 2 to 30 months (mean 14 months). Results. The technical success rate was 98%. All procedures were relatively painless. Two PCBs burst and 4 leaked, but without causing any morbidity. Nineteen fistulas were still working at last follow-up. Primary patency rates at 6, 12, and 24 months using Kaplan-Meier analysis were 88%, 73%, and 34%, respectively, and the primary assisted patencies were 90%, 75%, and 50%, respectively. Conclusion. PCB angioplasty has high technical success and low complication rates. The long-term patency rates are favorable for PCB angioplasty and compare favorably with other series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization Coils Migrating and Being Passed per Rectum After Embolization of a Splenic Artery Pseudoaneurysm, 'The Migrating Coil': A Case Report

Acute or chronic blood loss from pseudoaneurysms of the splanchnic artery in chronic pancreatitis poses diagnostic and management challenges. Arteriographic examination offers both diagnostic and therapeutic options, with success rates of 76%-100% for both modalities. In cases of failure of embolization, repeat embolization is also an option. Surgical intervention is advocated for rebleeding and failure of embolization. Evidence-based guidelines regarding the optimal treatment modality for this condition are lacking. There has been a reported case of dislodgement of coil into the stomach through a gastropseudocystic fistula. We report the case of a migrating steel-wire coil through the gastrointestinal tract and splenic artery pseudoaneurysm. We highlight the potential complications of pseudoaneurysm and other available therapeutic management options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Chemoembolization of Unresectable Hepatocellular Carcinoma with Drug Eluting Beads: Results of an Open-Label Study of 62 Patients

The purpose of this study was to assess the safety and efficacy of doxorubicin-loaded beads (DC Beads) delivered by transarterial embolization for the treatment of unresectable hepatocellular carcinoma (HCC). This open-label, single-center, single-arm study included 62 cirrhotic patients with documented single unresectable HCC. Mean tumor diameter was 5.6 cm (range, 3-9 cm) classified as Okuda stages 1 (n = 53) and 2 (n = 9). Patients received repeat embolizations with doxorubicin-loaded beads every 3 months (maximum of three). The maximum doxorubicin dose was 150 mg per embolization, loaded in DC Beads of 100-300 or 300-500 {mu}m. Regarding efficacy, overall, an objective response according to the European Association for the Study of the Liver criteria was observed in 59.6%, 81.8%, and 70.8% across three treatments. A complete response was observed in 4.8% after the first procedure and 3.6% and 8.3% after the second and third procedures, respectively. At 9 months a complete response was seen in 12.2%, an objective response in 80.7%, progressive disease in 6.8%, and 12.2% showed stable disease. Mean tumor necrosis ranged from 77.4% to 83.9% (range, 28.6%-100%) across three treatments. {alpha}-Fetoprotein levels showed a mean decrease of 1123 ng/ml (95% CI = 846-1399; p = 3 x 10{sup -11}) after the first session and remained stable after the second and third embolizations (42 and 70 ng/ml decrease, respectively). Regarding safety, bilirubin, {gamma}-glutamyl transferase, aspartate aminotransferase, alanine aminotransferase, and alkaline phosphatase showed only transient increases during the study period. Severe procedure-related complications were seen in 3.2% (cholecystitis, n 1; liver abscess, n = 1). Postembolization syndrome was observed in all patients. We conclude that hemoembolization using doxorubicin-loaded DC Beads is a safe and effective treatment of HCC as demonstrated by the low complication rate, increased tumor response, and sustained reduction of {alpha}-fetoprotein levels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of Spontaneous Hemarthrosis Post Total Knee Replacement

Spontaneous nonhemophiliac hemarthrosis is an unusual entity, which has been little described. We present three cases of spontaneous recurrent hemarthrosis post total knee replacement (TKR) and successful management with embolization. Three male patients were referred to our service for angiography and treatment of recurrent hemarthrosis post TKR. In all three patients antegrade ipsilateral common femoral artery punctures and selective angiography of the geniculate branches were performed with a microcatheter. Abnormal vasculature was noted in all cases. Subsequent embolization was performed with Contour (Boston Scientific, Target Vascular, Cork, Ireland) embolization particles (150-250 and 250-355 {mu}m) in two patients and microcoils in the third (TornadoR; Cook Inc., Bloomington, IN, USA). Technical success was 100%. One patient had a recurrence of symptoms requiring a repeat procedure 6 months later. No complications were encountered. Selective angiography and particle embolization is an effective technique for management of this unusual but problematic postoperative sequelae.

62 RADIOLOGY AND NUCLEAR MEDICINE↗