Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Artifacts in X-ray Dark-Field Tomography

Grating-based x-ray imaging provides three principle kinds of contrast: absorption, phase, and dark-field. Due to the availability of tomographic reconstruction algorithms for the dark-field contrast, it is now possible to take advantage of quantitative scatter information. However, the published algorithm is based on several assumptions that might be violated in reality. We use numerical simulations in order to identify artifacts in the reconstructions, which is crucial for the interpretation of experimental data.

07 ISOTOPE AND RADIATION SOURCES↗

Development of Coherent X-ray Diffraction Apparatus with Kirkpatrick-Baez Mirror Optics

To realize coherent x-ray diffraction microscopy with higher spatial resolution, it is necessary to increase the density of x-ray photons illuminated onto the sample. In this study, we developed a coherent x-ray diffraction apparatus with Kirkpatrick-Baez mirror optics. By using mirrors fabricated by elastic emission machining, a high-density coherent x-ray beam was produced. In a demonstration experiment using a silver nanocube as a sample, a high-contrast coherent x-ray diffraction pattern was observed over a wide-q range. This proves that both the density and the degree of coherence of the focused beam were high.

07 ISOTOPE AND RADIATION SOURCES↗

SSRF Beamline Control System

There are seven beamlines in the Phase-I of SSRF. Five of them are equipped with Insertion Devices, while two with Bending Magnets. The beamline control system is based on the standard hardware and software architecture. The VME(PowerPC) with VxWorks is used for motion control, while the personal computers with Scientific Linux are the front end controllers of equipment protection and personnel safety systems. The control software is developed under EPICS which makes various experimental programs of Blu-Ice, LabView, VC and SPEC conveniently access Monochromators, mirror chambers and other optical components.

43 PARTICLE ACCELERATORS↗

Preliminary Results from Pyroelectric Crystal Accelerator

The Nuclear Science and Engineering Research Center (NSERC), a Defense Threat Reduction Agency (DTRA) office located at the United States Military Academy (USMA), sponsors and manages cadet and faculty research in support of DTRA objectives. Cadets in the Department of Physics and Nuclear Engineering at USMA are using pyroelectric crystals to ionize and accelerate residual gas trapped inside a vacuum system. A system using two lithium tantalate crystals with associated diagnostics was designed and is now operational. X-ray energies of approximately 150 keV have been achieved. Future work will focus on developing a portable neutron generator using the D-D nuclear fusion process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scattering and; Delay, Scale, and Sum Migration

How do we see? What is the mechanism? Consider standing in an open field on a clear sunny day. In the field are a yellow dog and a blue ball. From a wave-based remote sensing point of view the sun is a source of radiation. It is a broadband electromagnetic source which, for the purposes of this introduction, only the visible spectrum is considered (approximately 390 to 750 nanometers or 400 to 769 TeraHertz). The source emits an incident field into the known background environment which, for this example, is free space. The incident field propagates until it strikes an object or target, either the yellow dog or the blue ball. The interaction of the incident field with an object results in a scattered field. The scattered field arises from a mis-match between the background refractive index, considered to be unity, and the scattering object refractive index ('yellow' for the case of the dog, and 'blue' for the ball). This is also known as an impedance mis-match. The scattering objects are referred to as secondary sources of radiation, that radiation being the scattered field which propagates until it is measured by the two receivers known as 'eyes'. The eyes focus the measured scattered field to form images which are processed by the 'wetware' of the brain for detection, identification, and localization. When time series representations of the measured scattered field are available, the image forming focusing process can be mathematically modeled by delayed, scaled, and summed migration. This concept of optical propagation, scattering, and focusing have one-to-one equivalents in the acoustic realm. This document is intended to present the basic concepts of scalar scattering and migration used in wide band wave-based remote sensing and imaging. The terms beamforming and (delayed, scaled, and summed) migration are used interchangeably but are to be distinguished from the narrow band (frequency domain) beamforming to determine the direction of arrival of a signal, and seismic migration in which wide band time series are shifted but not to form images per se. Section 3 presents a mostly graphically-based motivation and summary of delay, scale, and sum beamforming. The model for incident field propagation in free space is derived in Section 4 under specific assumptions. General object scattering is derived in Section 5 and simplified under the Born approximation in Section 6. The model of this section serves as the basis in the derivation of time-domain migration. The Foldy-Lax, full point scatterer scattering, method is derived in Section 7. With the previous forward models in hand, delay, scale, and sum beamforming is derived in Section 8. Finally, proof-of-principle experiments are present in Section 9.

42 ENGINEERING↗

Future Opportunities in Plasma Physics with FELs

I will discuss experiments to understand the nature of hot and dense matter using ultrafast x-ray pulses from synchrotrons and free electron lasers. The capabilities of these new light sources will allow greater understanding of the structure, bonding, and properties of these unique plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New Nanoscale Imaging with a Simple Hard X-Ray Nanoslit

A simple and new procedure to measure the optimal intensity distribution of an x-ray wavefield in nanoscale resolution is proposed. A heavy-metal wire can work as a ''nanoslit'' with a nanoscale aperture size. Its basic function can be described simply with geometrical optics using total reflection. The further function is investigated with numerical calculation of a diffraction edge. In the experiment, Fresnel fringes generated by a rectangular aperture were measured by using a 300-{mu}m platinum wire as the nanoslit. Its high potential use in imaging applications is discussed.

07 ISOTOPE AND RADIATION SOURCES↗

X-ray propagation microscopy of biological cells using waveguides as a quasipoint source

We have used x-ray waveguides as highly confining optical elements for nanoscale imaging of unstained biological cells using the simple geometry of in-line holography. The well-known twin-image problem is effectively circumvented by a simple and fast iterative reconstruction. The algorithm which combines elements of the classical Gerchberg-Saxton scheme and the hybrid-input-output algorithm is optimized for phase-contrast samples, well-justified for imaging of cells at multi-keV photon energies. The experimental scheme allows for a quantitative phase reconstruction from a single holographic image without detailed knowledge of the complex illumination function incident on the sample, as demonstrated for freeze-dried cells of the eukaryotic amoeba Dictyostelium discoideum. The accessible resolution range is explored by simulations, indicating that resolutions on the order of 20 nm are within reach applying illumination times on the order of minutes at present synchrotron sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Following Dynamic Processes by X-ray Tomographic Microscopy with Sub-second Temporal Resolution

Several non-destructive imaging techniques offer the possibility to observe rapid phenomena in real time, yet most of these techniques fail when it comes to bulky samples and micrometer precision in three dimensions. Therefore there is clearly a need to develop approaches that address such conditions. We identified the large potential that lies in synchrotron-based x-rays as a probe and developed a direct-space tomographic instrument suitable to provide sub-second temporal resolution with several-micrometers spatial resolution. Selected applications from the field of biology and material science are shown in order to demonstrate the unique capabilities in generating three-dimensional images with very high quality making image segmentation and analysis possible for samples that could, until now, only be studied in two dimensions due to the occurrence of rapid structural changes.

07 ISOTOPE AND RADIATION SOURCES↗

Radiation Safety of Sealed Radioactive Sources

Sealed radioactive sources are used in a wide variety of occupational settings and under differing regulatory/licensing structures. The definition of a sealed radioactive source varies between US regulatory authorities and standard-setting organizations. Potential problems with sealed sources cover a range of risks and impacts. The loss of control of high activity sealed sources can result in very high or even fatal doses to members of the public who come in contact with them. Sources that are not adequately sealed, and that fail, can cause spread of contamination and potential intake of radioactive material. There is also the possibility that sealed sources may be (or threatened to be) used for terrorist purposes and disruptive opportunities. Until fairly recently, generally-licensed sealed sources and devices received little, if any, regulatory oversight, and were often forgotten, lost or unaccounted for. Nonetheless, generally licensed devices can contain fairly significant quantities of radioactive material and there is some potential for exposure if a device is treated in a way that it was never designed. Industrial radiographers use and handle high activity and/or high-dose rate sealed sources in the field with a high degree of independence and minimal regulatory oversight. Failure to follow operational procedures and properly handle radiography sources can and has resulted in serious injuries and death. Industrial radiographers have experienced a disproportionately large fraction of incidents that result in unintended exposure to radiation. Sources do not have to contain significant quantities of radioactive material to cause problems in the event of their failure. A loss of integrity can cause the spread of contamination and potential exposure to workers and members of the public. The NCRP has previously provided recommendations on select aspects of sealed source programs. Future efforts to provide recommendations for sealed source programs are discussed.

radioactive material↗

Beam Stability: Benefits from Concentrating on Basics

In recent years there has been a lot of activity aimed at producing smaller and more intense beams. However, experience has shown that with these beams the quality of the data obtained is highly sensitive to alignment issues, mechanical (in)stabilities, source instabilities, material choices and surface degradations of optical components. Over several years the ESRF has investigated many beamline optical components with the view to improve both beam and sample stability. The measures that have been taken to achieve these improvements are described together with possible improvements that could be envisaged in the future.

43 PARTICLE ACCELERATORS↗

Focusing Kinoform Lenses: Optical Design and Experimental Validation

X-ray focusing lenses with a kinoform profile are high brilliance optics that can produce nano-sized beams on 3rd generation synchrotron beamlines. The lenses are fabricated with sidewalls of micrometer lateral size. They are virtually non-absorbing and therefore can deliver a high flux over a good aperture. We are developing silicon and germanium lenses that will focus hard x-ray beams to less than 0.5 {mu}m size using a single refractive element. In this contribution, we present preliminary optical design and experimental test carried out on ID06 ESRF: the lenses were used to image directly the undulator source, providing a beam with fwhm of about 0.7 {mu}m.

43 PARTICLE ACCELERATORS↗

Confocal Microscope Alignment of Nanocrystals for Coherent Diffraction Imaging

We have installed and tested an Olympus LEXT confocal microscope at the 34-ID-C beamline of the Advanced Photon Source (APS). The beamline is for Coherent X-ray Diffraction (CXD) experiments in which a nanometre-sized crystal is aligned inside a focussed X-ray beam. The microscope was required for three-dimensional (3D) sample alignment to get around sphere-of-confusion issues when locating Bragg peaks in reciprocal space. In this way, and by use of strategic sample preparations, we have succeeded in measuring six Bragg peaks from a single 200 nm gold crystal and obtained six projections of its internal displacement field. This enables the clear identification of stacking-fault bands within the crystal. The confocal alignment method will allow a full determination of the strain tensor provided three or more Bragg reflections from the same crystal are found.

43 PARTICLE ACCELERATORS↗

γ-ray generation enhancement by the charge separation field in laser-target interaction in the radiation dominated regime

A new source of radiation can be created with a laser pulse of intensity ≈10{sup 23 }W/cm{sup 2} interacting with a slightly overdense plasma. Collective effects driven by the electrostatic field significantly enhance the synchrotron radiation. They impact on the laser energy repartition leading to a specific emission but also constitute a crucial element for the intense radiation production. They allow electrons to be accelerated over a length up to 10 laser wavelengths favoring emission of an intense radiation. It is shown that charge separation field depends on the ion mass and target thickness but also on laser polarization. These phenomena are studied with an one dimensional relativistic particle-in-cell code accounting for the classical radiation reaction force.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Soft X-ray Spectromicroscopy Beamline at SSRF

Commissioning of the soft x-ray spectromicroscopy beanmline at SSRF was formally started on Dec 26, 2008. Beamline performance has reached or surpassed the designing goals according to the measurements by domestic experts, especially for its high energy resolution and high spatial resolution. Since its first operation by users on May 6, 2009, tens of experiments have been conducted, and some preliminary exciting results have been acquired.

07 ISOTOPE AND RADIATION SOURCES↗

Optical Design of VLS-PGM Soft X-Ray Beamline on Indus-2

The optical design of a soft x-ray beamline on the bending magnet of Indus-2 synchrotron source is presented. A Varied Line Spacing Plane Grating Monochromator (VLS-PGM) was adopted with Hettrick type optics. The VLS-PGM consists of a spherical mirror and three interchangeable gratings of line densities 1200 l/mm, 400 l/mm and 150 l/mm to efficiently cover the energy region 50-1500 eV. The VLS groove parameters were obtained by minimizing defocus aberration, coma and spherical aberration. The overall performance of the beamline was estimated by detailed raytracing calculations. The beamline design, results of the raytracing calculations and the expected performances are presented.

43 PARTICLE ACCELERATORS↗

How Much Does Lead Shielding during Fluoroscopy Reduce Radiation Dose to Out-of-Field Body Parts?

Fluoroscopy technologists routinely place a lead shield between the x-ray table and the patient's gonads, even if the gonads are not directly in the x-ray field. Internal scatter radiation is the greatest source of radiation to out-of-field body parts, but a shield placed between the patient and the x-ray source will not block internal scatter. Prior nonfluoroscopy research has shown that there is a small reduction in radiation dose when shielding the leakage radiation that penetrates through the collimator shutters. The goal of this in vitro study was to determine if there was any radiation dose reduction when shielding leakage radiation during fluoroscopy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗