Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Development of a broadband hard x-ray radiography platform for pulsed-power experiments

In this article, we develop and demonstrate a broadband hard x-ray radiography platform at the Zebra Pulsed Power Laboratory that integrates point-projection radiography, bremsstrahlung measurements, and hard x-ray pinhole imaging, designed to diagnose current-driven, cylindrically compressed matter. Initial laser-pulsed-power coupled experiments revealed that intense background radiation generated during 1 MA Zebra current shots overwhelmed laser-produced hard x-rays, obscuring radiographic images. Using combined spectral and spatial diagnostics, we identify energetic electrons accelerated by return currents as the dominant source of background hard x-rays, with electron energies inferred to be 3–4 MeV based on Monte Carlo simulations, and demonstrate mitigation through modifications to the radiation shielding and return-current configuration. The diagnostic platform was validated using a wire-pinch hard x-ray source, allowing radiographs of static 1-mm-diameter aluminum wires to be obtained while simultaneously measuring x-ray source spectra and spatial emission distributions within a single shot. Measured wire transmission profiles were quantitatively reconstructed using radiation transport simulations that incorporate an experimentally inferred two-temperature exponential x-ray spectrum from bremsstrahlung signal analysis and spatially distributed emission sources identified by pinhole imaging. Agreement between measured and simulated transmission profiles demonstrates the validity of the radiographic and x-ray source characterization approach, establishing this diagnostic platform as a promising tool for diagnosing magnetically driven, high-density plasmas relevant to warm dense matter and inertial fusion energy research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photon energy-modulated radiotherapy: Monte Carlo simulation and treatment planning study

Purpose: To demonstrate the feasibility of photon energy-modulated radiotherapy during beam-on time. Methods: A cylindrical device made of aluminum was conceptually proposed as an energy modulator. The frame of the device was connected with 20 tubes through which mercury could be injected or drained to adjust the thickness of mercury along the beam axis. In Monte Carlo (MC) simulations, a flattening filter of 6 or 10 MV linac was replaced with the device. The thickness of mercury inside the device varied from 0 to 40 mm at the field sizes of 5 x 5 cm{sup 2} (FS5), 10 x 10 cm{sup 2} (FS10), and 20 x 20 cm{sup 2} (FS20). At least 5 billion histories were followed for each simulation to create phase space files at 100 cm source to surface distance (SSD). In-water beam data were acquired by additional MC simulations using the above phase space files. A treatment planning system (TPS) was commissioned to generate a virtual machine using the MC-generated beam data. Intensity modulated radiation therapy (IMRT) plans for six clinical cases were generated using conventional 6 MV, 6 MV flattening filter free, and energy-modulated photon beams of the virtual machine. Results: As increasing the thickness of mercury, Percentage depth doses (PDD) of modulated 6 and 10 MV after the depth of dose maximum were continuously increased. The amount of PDD increase at the depth of 10 and 20 cm for modulated 6 MV was 4.8% and 5.2% at FS5, 3.9% and 5.0% at FS10 and 3.2%-4.9% at FS20 as increasing the thickness of mercury from 0 to 20 mm. The same for modulated 10 MV was 4.5% and 5.0% at FS5, 3.8% and 4.7% at FS10 and 4.1% and 4.8% at FS20 as increasing the thickness of mercury from 0 to 25 mm. The outputs of modulated 6 MV with 20 mm mercury and of modulated 10 MV with 25 mm mercury were reduced into 30%, and 56% of conventional linac, respectively. The energy-modulated IMRT plans had less integral doses than 6 MV IMRT or 6 MV flattening filter free plans for tumors located in the periphery while maintaining the similar quality of target coverage, homogeneity, and conformity. Conclusions: The MC study for the designed energy modulator demonstrated the feasibility of energy-modulated photon beams available during beam-on time. The planning study showed an advantage of energy-and intensity modulated radiotherapy in terms of integral dose without sacrificing any quality of IMRT plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE EMISSION BY DUST AND STARS OF NEARBY GALAXIES IN THE HERSCHEL KINGFISH SURVEY

Using new far-infrared imaging from the Herschel Space Observatory with ancillary data from ultraviolet (UV) to submillimeter wavelengths, we estimate the total emission from dust and stars of 62 nearby galaxies in the KINGFISH survey in a way that is as empirical and model independent as possible. We collect and exploit these data in order to measure from the spectral energy distributions (SEDs) precisely how much stellar radiation is intercepted and re-radiated by dust, and how this quantity varies with galaxy properties. By including SPIRE data, we are more sensitive to emission from cold dust grains than previous analyses at shorter wavelengths, allowing for more accurate estimates of dust temperatures and masses. The dust/stellar flux ratio, which we measure by integrating the SEDs, has a range of nearly three decades (from 10{sup -2.2} to 10{sup 0.5}). The inclusion of SPIRE data shows that estimates based on data not reaching these far-IR wavelengths are biased low by 17% on average. We find that the dust/stellar flux ratio varies with morphology and total infrared (IR) luminosity, with dwarf galaxies having faint luminosities, spirals having relatively high dust/stellar ratios and IR luminosities, and some early types having low dust/stellar ratios. We also find that dust/stellar flux ratios are related to gas-phase metallicity log(f{sub dust}/f{sub *})-bar = -0.66{+-}0.08 and -0.22 {+-} 0.12 for metal-poor and intermediate-metallicity galaxies, respectively), while the dust/stellar mass ratios are less so (differing by {approx}0.2 dex); the more metal-rich galaxies span a much wider range of the flux ratios. In addition, the substantial scatter between dust/stellar flux and dust/stellar mass indicates that the former is a poor proxy of the latter. Comparing the dust/stellar flux ratios and dust temperatures, we also show that early types tend to have slightly warmer temperatures (by up to 5 K) than spiral galaxies, which may be due to more intense interstellar radiation fields, or possibly to different dust grain compositions. Finally, we show that early types and early-type spirals have a strong correlation between the dust/stellar flux ratio and specific star formation rate, which suggests that the relatively bright far-IR emission of some of these galaxies is due to ongoing (if limited) star formation as well as to the radiation field from older stars, which is heating the dust grains.

79 ASTRONOMY AND ASTROPHYSICS↗

Simultaneous beam sampling and aperture shape optimization for SPORT

Purpose: Station parameter optimized radiation therapy (SPORT) was recently proposed to fully utilize the technical capability of emerging digital linear accelerators, in which the station parameters of a delivery system, such as aperture shape and weight, couch position/angle, gantry/collimator angle, can be optimized simultaneously. SPORT promises to deliver remarkable radiation dose distributions in an efficient manner, yet there exists no optimization algorithm for its implementation. The purpose of this work is to develop an algorithm to simultaneously optimize the beam sampling and aperture shapes. Methods: The authors build a mathematical model with the fundamental station point parameters as the decision variables. To solve the resulting large-scale optimization problem, the authors devise an effective algorithm by integrating three advanced optimization techniques: column generation, subgradient method, and pattern search. Column generation adds the most beneficial stations sequentially until the plan quality improvement saturates and provides a good starting point for the subsequent optimization. It also adds the new stations during the algorithm if beneficial. For each update resulted from column generation, the subgradient method improves the selected stations locally by reshaping the apertures and updating the beam angles toward a descent subgradient direction. The algorithm continues to improve the selected stations locally and globally by a pattern search algorithm to explore the part of search space not reachable by the subgradient method. By combining these three techniques together, all plausible combinations of station parameters are searched efficiently to yield the optimal solution. Results: A SPORT optimization framework with seamlessly integration of three complementary algorithms, column generation, subgradient method, and pattern search, was established. The proposed technique was applied to two previously treated clinical cases: a head and neck and a prostate case. It significantly improved the target conformality and at the same time critical structure sparing compared with conventional intensity modulated radiation therapy (IMRT). In the head and neck case, for example, the average PTV coverage D99% for two PTVs, cord and brainstem max doses, and right parotid gland mean dose were improved, respectively, by about 7%, 37%, 12%, and 16%. Conclusions: The proposed method automatically determines the number of the stations required to generate a satisfactory plan and optimizes simultaneously the involved station parameters, leading to improved quality of the resultant treatment plans as compared with the conventional IMRT plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time-resolved studies of the order-disorder phase transformations in rare-earth-transition metal intermetallics with 2-17 stoichiometry

High-temperature order-disorder transformations in R{sub 2}T{sub 17} and R{sub 2}T{sub 17}-M-C intermetallics with R = Pr, Sm, Dy, Tb; T = Co, Fe; and M = Zr, Nb were studied utilizing time-resolved synchrotron x-ray diffraction at the Advanced Photon Source (APS) at the U.S. Department of Energy's Argonne National Laboratory (Argonne, IL). High-energy synchrotron radiation provides intense, highly penetrating x-rays, which are ideal for in situ studies of phase transformations. Alloying additions are used to stabilize formation of metastable phases; their influence on order recovery was investigated. The experimental setup utilized Debye-Scherrer geometry; specimens were heated at a rate of 10 K/min. Full-profile diffraction patterns collected every 10 s were refined in sequence using the Rietveld method to track changes of lattice parameters and phase assemblages during heating. Sharp changes observed in the evolution of temperature-dependent lattice parameters suggested formation of ordered structure via nucleation and growth. Both 2-17 polymorphs co-existed in light and heavy rare-earth systems at high temperatures. The presence of alloying additions in the solid solution greatly influenced long-range order formation.

43 PARTICLE ACCELERATORS↗

SU-C-210-06: Quantitative Evaluation of Dosimetric Effects Resulting From Positional Variations of Pancreatic Tumor Volumes

Purpose: The aim of this study is to quantify dosimetric effects resulting from variation in pancreatic tumor position assessed by bony anatomy and implanted fiducial markers Methods: Twelve pancreatic cancer patients were retrospectively analyzed for this study. All patients received modulated arc therapy (VMAT) treatment using fiducial-based Image Guided Radiation Therapy (IGRT) to the intact pancreas. Using daily orthogonal kV and/or Cone beam CT images, the shift needed to co-register the daily pre-treatment images to reference CT from fiducial to bone (Fid-Bone) were recorded as Left-Right (LR), Anterior-Posterior (AP) and Superior-Inferior (SI). The original VMAT plan iso-center was shifted based on KV bone matching positions at 5 evenly spaced fractions. Dose coverage of the planning target volumes (PTVs) (V100%), mean dose to liver, kidney and stomach/duodenum were assessed in the modified plans. Results: A total of 306 fractions were analyzed. The absolute fiducial-bone positional shifts were greatest in the SI direction, (AP = 2.7 ± 3.0, LR = 2.8 ± 2.8, and SI 6.3 ± 7.9 mm, mean ± SD). The V100% was significantly reduced by 13.5%, (Fid-Bone = 95.3 ± 2.0 vs. 82.3 ± 11.8%, p=0.02). This varied widely among patients (Fid-Bone V100% Range = 2–60%), where 33% of patients had a reduction in V100% of more than 10%. The impact on OARs was greatest to the liver (Fid-Bone= 14.6 vs. 16.1 Gy, 10%), and stomach, (Fid-Bone = 23.9 vx. 25.5 Gy, 7%), however was not statistically significant (p=0.10 both). Conclusion: Compared to matching by fiducial markers, matching by bony anatomy would have substantially reduced the PTV coverage by 13.5%. This reinforces the importance of online position verification based on fiducial markers. Hence, implantation of fiducial markers is strongly recommended for pancreatic cancer patients undergoing intensity modulated radiation therapy treatments.

60 APPLIED LIFE SCIENCES↗

6 MV dosimetric characterization of the 160 MLC, the new Siemens multileaf collimator

New technical developments constantly aim at improving the outcome of radiation therapy. With the use of a computer-controlled multileaf collimator (MLC), the quality of the treatment and the efficiency in patient throughput is significantly increased. New MLC designs aim to further enhance the advantages. In this article, we present the first detailed experimental investigation of the new 160 MLC{sup TM}, Siemens Medical Solutions. The assessment included the experimental investigation of typical MLC characteristics such as leakage, tongue-and-groove effect, penumbra, leaf speed, and leaf positioning accuracy with a 6 MV treatment beam. The leakage is remarkably low with an average of 0.37% due to a new design principle of slightly tilted leaves instead of the common tongue-and-groove design. But due to the tilt, the triangular tongue-and-groove effect occurs. Its magnitude of approximately 19% is similar to the dose defect measured for MLCs with the common tongue-and-groove design. The average longitudinal penumbra measured at depth d{sub max}=15 mm with standard 100x100 mm{sup 2} fields is 4.1{+-}0.5 mm for the central range and increases to 4.9{+-}1.3 mm for the entire field range of 400x400 mm{sup 2}. The increase is partly due to the single-focusing design and the large distance between the MLC and the isocenter enabling a large patient clearance. Regarding the leaf speed, different velocity tests were performed. The positions of the moving leaves were continuously recorded with the kilovoltage-imaging panel. The maximum leaf velocities measured were 42.9{+-}0.6 mm/s. In addition, several typical intensity-modulated radiation therapy treatments were performed and the delivery times compared to the Siemens OPTIFOCUS MLC. An average decrease of 11% in delivery time was observed. The experimental results presented in this article indicate that the dosimetric characteristics of the 160 MLC are capable of improving the quality of dose delivery with respect to precision and dose conformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contouring Guidelines for the Axillary Lymph Nodes for the Delivery of Radiation Therapy in Breast Cancer: Evaluation of the RTOG Breast Cancer Atlas

Purpose: The purpose of this study was to identify the axillary lymph nodes on pretreatment diagnostic computed tomography (CT) of the chest to determine their position relative to the anatomic axillary borders as defined by the Radiation Therapy Oncology Group (RTOG) breast cancer atlas for radiation therapy planning. Methods and Materials: Pretreatment diagnostic CT chest scans available for 30 breast cancer patients with clinically involved lymph nodes were fused with simulation CT. Contouring of axillary levels I, II, and III according to the RTOG guidelines was performed. Measurements were made from the area of distal tumor to the anatomic borders in 6 dimensions for each level. Results: Of the 30 patients, 100%, 93%, and 37% had clinical involvement of levels I, II, and III, respectively. The mean number of lymph nodes dissected was 13.6. The mean size of the largest lymph node was 2.4 cm. Extracapsular extension was seen in 23% of patients. In 97% of patients, an aspect of the involved lymph node lay outside of the anatomic border of a level. In 80% and 83% of patients, tumor extension was seen outside the cranial (1.78 ± 1.0 cm; range, 0.28-3.58 cm) and anterior (1.27 ± 0.92 cm; range, 0.24-3.58 cm) borders of level I, respectively. In 80% of patients, tumor extension was seen outside the caudal border of level II (1.36 ± 1.0 cm, range, 0.27-3.86 cm), and 0% to 33% of patients had tumor extension outside the remaining borders of all levels. Conclusions: To cover 95% of lymph nodes at the cranial and anterior borders of level I, an additional clinical target volume margin of 3.78 cm and 3.11 cm, respectively, is necessary. The RTOG guidelines may be insufficient for coverage of axillary disease in patients with clinical nodal involvement who are undergoing neoadjuvant chemotherapy, incomplete axillary dissection, or treatment with intensity modulated radiation therapy. In patients with pretreatment diagnostic CT chest scans, fusion with simulation CT should be considered for tumor delineation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Internal margin assessment using cine MRI analysis of deglutition in head and neck cancer radiotherapy

Purpose: Intensity-modulated radiation therapy (IMRT) is a promising treatment modality for patients with head and neck cancer (HNC). The dose distributions from IMRT are static and, thus, are unable to account for variations and/or uncertainties in the relationship between the patient (region being treated) and the beam. Organ motion comprises one such source of this uncertainty, introduced by physiological variation in the position, size, and shape of organs during treatment. In the head and neck, the predominant source of this variation arises from deglutition (swallowing). The purpose of this study was to investigate whether cinematographic MRI (cine MRI) could be used to determine asymmetric (nonuniform) internal margin (IM) components of tumor planning target volumes based on the actual deglutition-induced tumor displacement. Methods: Five head and neck cancer patients were set up in treatment position on a 3 T MRI scanner. Two time series of single-slice, sagittal, cine images were acquired using a 2D FLASH sequence. The first time series was a 12.8 min scan designed to capture the frequency and duration of deglutition in the treatment position. The second time series was a short, 15 s scan designed to capture the displacement of deglutition in the treatment position. Deglutition frequency and mean swallow duration were estimated from the long time series acquisition. Swallowing and resting (nonswallowing) events were identified on the short time series acquisition and displacement was estimated based on contours of gross tumor volume (GTV) generated at each time point of a particular event. A simple linear relationship was derived to estimate 1D asymmetric IMs in the presence of resting- and deglutition-induced displacement. Results: Deglutition was nonperiodic, with frequency and duration ranging from 2.89-24.18 mHz and from 3.86 to 6.10 s, respectively. The deglutition frequency and mean duration were found to vary among patients. Deglutition-induced maximal GTV displacements ranged from 0.00 to 28.36 mm with mean and standard deviation of 4.72{+-}3.18, 3.70{+-}2.81, 2.75{+-}5.24, and 10.40{+-}10.76 mm in the A, P, I, and S directions, respectively. Resting-induced maximal GTV displacement ranged from 0.00 to 5.59 mm with mean and standard deviation of 3.01{+-}1.80, 1.25{+-}1.10, 3.23+2.20, and 2.47{+-}1.11 mm in the A, P, I, and S directions, respectively. For both resting and swallowing states, displacement along the S-I direction dominated displacement along the A-P direction. The calculated IMs were dependent on deglutition frequency, ranging from 3.28-4.37 mm for the lowest deglutition frequency patient to 3.76-6.43 mm for the highest deglutition frequency patient. A statistically significant difference was detected between IMs calculated for P and S directions (p=0.0018). Conclusions: Cine MRI is able to capture tumor motion during deglutition. Swallowing events can be demarcated by MR signal intensity changes caused by anatomy containing fully relaxed spins that move medially into the imaging plane during deglutition. Deglutition is nonperiodic and results in dynamic changes in the tumor position. Deglutition-induced displacements are larger and more variable than resting displacements. The nonzero mean maximum resting displacement indicates that some tumor motion occurs even when the patient is not swallowing. Asymmetric IMs, derived from deglutition frequency, duration, and directional displacement, should be employed to account for tumor motion in HNC RT.

60 APPLIED LIFE SCIENCES↗

Numerical studies of powerful terahertz pulse generation from a super-radiant surface wave oscillator

The results of theoretical and numerical studies of coherent stimulated terahertz radiation from intense, subnanosecond electron beam are presented. The mechanism of terahertz pulse generation is associated with self-bunching of the beam and slippage of the wave over the whole electron flow. This so called Cherenkov super-radiance (SR) is used to propose a compact terahertz generator with high peak power. A large cross-section (overmoded), slow wave structure is designed to support the high power handling capability, and the mode competition is avoided by operating the device in the surface wave status. With 2.5 D particle-in-cell simulation, the 'hot' characteristics of the proposed super-radiant terahertz generator are investigated, and the numerical results show that the SR peak power could be further increased by optimizing the amplitude profile of electron pulse. Under the condition of 0.5 ns pulsewidth, 500 kV voltage, and 1.5 kA current, the 110 ps, 680 MW, and 0.14 THz SR pulse is achieved with a power efficiency of 90.67% in TM{sub 01} mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive beamlet-based finite-size pencil beam dose calculation for independent verification of IMRT and VMAT

Purpose: The use of sophisticated dose calculation procedure in modern radiation therapy treatment planning is inevitable in order to account for complex treatment fields created by multileaf collimators (MLCs). As a consequence, independent volumetric dose verification is time consuming, which affects the efficiency of clinical workflow. In this study, the authors present an efficient adaptive beamlet-based finite-size pencil beam (AB-FSPB) dose calculation algorithm that minimizes the computational procedure while preserving the accuracy. Methods: The computational time of finite-size pencil beam (FSPB) algorithm is proportional to the number of infinitesimal and identical beamlets that constitute an arbitrary field shape. In AB-FSPB, dose distribution from each beamlet is mathematically modeled such that the sizes of beamlets to represent an arbitrary field shape no longer need to be infinitesimal nor identical. As a result, it is possible to represent an arbitrary field shape with combinations of different sized and minimal number of beamlets. In addition, the authors included the model parameters to consider MLC for its rounded edge and transmission. Results: Root mean square error (RMSE) between treatment planning system and conventional FSPB on a 10 × 10 cm{sup 2} square field using 10 × 10, 2.5 × 2.5, and 0.5 × 0.5 cm{sup 2} beamlet sizes were 4.90%, 3.19%, and 2.87%, respectively, compared with RMSE of 1.10%, 1.11%, and 1.14% for AB-FSPB. This finding holds true for a larger square field size of 25 × 25 cm{sup 2}, where RMSE for 25 × 25, 2.5 × 2.5, and 0.5 × 0.5 cm{sup 2} beamlet sizes were 5.41%, 4.76%, and 3.54% in FSPB, respectively, compared with RMSE of 0.86%, 0.83%, and 0.88% for AB-FSPB. It was found that AB-FSPB could successfully account for the MLC transmissions without major discrepancy. The algorithm was also graphical processing unit (GPU) compatible to maximize its computational speed. For an intensity modulated radiation therapy (∼12 segments) and a volumetric modulated arc therapy fields (∼90 control points) with a 3D grid size of 2.0 × 2.0 × 2.0 mm{sup 3}, dose was computed within 3–5 and 10–15 s timeframe, respectively. Conclusions: The authors have developed an efficient adaptive beamlet-based pencil beam dose calculation algorithm. The fast computation nature along with GPU compatibility has shown better performance than conventional FSPB. This enables the implementation of AB-FSPB in the clinical environment for independent volumetric dose verification.

60 APPLIED LIFE SCIENCES↗

H I-to-H{sub 2} transitions and H I column densities in galaxy star-forming regions

We present new analytic theory and radiative transfer computations for the atomic-to-molecular (H I-to-H{sub 2}) transitions and the buildup of atomic hydrogen (H I) gas columns in optically thick interstellar clouds irradiated by far-UV (FUV) photodissociating radiation fields. We derive analytic expressions for the total H I column densities for (one-dimensional (1D)) planar slabs, for beamed or isotropic radiation fields, from the weak- to strong-field limits, for gradual or sharp atomic-to-molecular transitions, and for arbitrary metallicity. Our expressions may be used to evaluate the H I column densities as functions of the radiation field intensity and the H{sub 2}-dust-limited dissociation flux, the hydrogen gas density, and the metallicity-dependent H{sub 2} formation rate coefficient and FUV dust grain absorption cross section. We make the distinction between 'H I-dust' and 'H{sub 2}-dust' opacity, and we present computations for the 'universal H{sub 2}-dust-limited effective dissociation bandwidth'. We validate our analytic formulae with Meudon PDR code computations for the H I-to-H{sub 2} density profiles and total H I column densities. We show that our general 1D formulae predict H I columns and H{sub 2} mass fractions that are essentially identical to those found in more complicated (and approximate) spherical (shell-core) models. We apply our theory to compute H{sub 2} mass fractions and star-formation thresholds for individual clouds in self-regulated galaxy disks, for a wide range of metallicities. Our formulae for the H I columns and H{sub 2} mass fractions may be incorporated into hydrodynamics simulations for galaxy evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of EBT2 film using a red-channel PDD method in combination with a modified three-channel technique

Purpose: Ashland Inc. EBT2 and EBT3 films are widely used in quality assurance for radiation therapy; however, there remains a relatively high degree of uncertainty [B. Hartmann, M. Martisikova, and O. Jakel, “Homogeneity of Gafchromic EBT2 film,” Med. Phys. 37, 1753–1756 (2010)]. Micke et al. (2011) recently improved the spatial homogeneity using all color channels of a flatbed scanner; however, van Hoof et al. (2012) pointed out that the corrected nonuniformity still requires further investigation for larger fields. To reduce the calibration errors and the uncertainty, the authors propose a new red-channel percentage-depth-dose method in combination with a modified three-channel technique. Methods: For the ease of comparison, the EBT2 film image used in the authors’ previous study (2012) was reanalyzed using different approaches. Photon beams of 6-MV were delivered to two different films at two different beam on times, resulting in the absorption doses of ranging from approximately 30 to 300 cGy at the vertical midline of the film, which was set to be coincident with the central axis of the beam. The film was tightly sandwiched in a 30{sup 3}-cm{sup 3} polystyrene phantom, and the pixel values for red, green, and blue channels were extracted from 234 points on the central axis of the beam and compared with the corresponding depth doses. The film was first calibrated using the multichannel method proposed by Micke et al. (2010), accounting for nonuniformities in the scanner. After eliminating the scanner and dose-independent nonuniformities, the film was recalibrated via the dose-dependent optical density of the red channel and fitted to a power function. This calibration was verified via comparisons of the dose profiles extracted from the films, where three were exposed to a 60° physical wedge field and three were exposed to composite fields, and all of which were measured in a water phantom. A correction for optical attenuation was implemented, and treatment plans of intensity modulated radiation therapy and volumetric modulated arc therapy were evaluated. Results: The method described here demonstrated improved accuracy with reduced uncertainty. The relative error compared with the measurements of a water phantom was less than 1%, and the overall calibration uncertainty was less than 2%. Verification tests revealed that the results were close to those of the authors’ previous study, and all differences were within 3%, except those with a high-dose gradient. The gamma pass rates (2%/2 mm) of the treatment plan evaluated using the method described here were greater than 99%, and no obvious stripe patterns were observed in the dose-difference maps. Conclusions: Spatial homogeneity was significantly improved via the calibration method described here. This technique is both convenient and time-efficient because it does not require cutting the film, and only two exposures are necessary.

60 APPLIED LIFE SCIENCES↗

Calculation of radiative properties of nonequilibrium hydrogen plasma

A computer program called NEQRAP is described that calculates the radiative properties of nonequilibrium ionized hydrogen. From the given electron temperature, electron density, and atom density values (which do not necessarily satisfy the equilibrium relationship) and intensities of incident radiation, the non-Boltzmann populations of electronic states are computed by solving the equation of quasi-steady-state population distribution. Emission and absorption coefficients are determined as functions of wavelength by invoking the principle of detailed balance between the upper and lower states of each radiative transition. Radiative transport through the medium is computed assuming a one-dimensional uniform slab. The rate of ionic reaction is also computed. When used on a sample case, the program shows that there is a large difference between the calculated intensities of radiation emitted by a bulk of equilibrium and nonequilibrium hydrogen. The accuracy of the program is estimated to be better than 10%.

Park, C.↗

Coherent Manipulation of Single Electrons with Optical Photons in Condensed Helium-4

Single electrons are one of the simplest quantum objects in nature. In free space or conventional materials, single electrons hardly interact with optical (ultraviolet-visible-infrared) photons, so their quantum states cannot be easily manipulated by optics. Here, a notable exception is is theoretically demonstrated: A single electron in condensed helium-4 can be self-confined in a nanometric bubble of 1 to 2 nm radius and resonantly interact with mid-infrared photons of 3 to 12 μm wavelength. A femtosecond laser can drive the electron into Rabi oscillations and prepare it onto arbitrary superposition states between the ground and excited states. After the laser pulse, the electron bubble can exhibit remarkable nonequilibrium quantum dynamics and evolve toward various final states with various lifetimes. These processes are accompanied with intense phonon radiation.

36 MATERIALS SCIENCE↗

Multiconfiguration Dirac–Fock calculations of Zn K‐shell radiative and nonradiative transitions

Zinc K‐shell radiative and radiationless transition rates are calculated using the multiconfiguration Dirac–Fock method. Correlation up to the 4p orbital is included in almost all transition rate calculations. Calculated radiative transition rates and transition probabilities are compared with Scofield's Dirac–Hartree–Slater and Dirac–Hartree–Fock calculations, presenting good agreement with the later. Radiative transition intensity ratios involving the strongest lines are compared with theoretical, experimental, and empirical‐fit values. Most ratios are in close agreement with the empirical‐fit values from NIST's Fundamental Parameters database. Calculated radiationless transition rates and ratios are compared with Chen et al.'s Dirac–Fock values and Safronova et al.'s Dirac–Fock values. The K‐LL transition rates are overall lower than Chen et al.'s values, whereas the K‐LX and K‐XY transition rates are overall higher. Calculated K‐LX/K‐LL and K‐XY/K‐LL ratios are relatively close to the experimental values compared. Some calculated intensities relative to K‐L are in good agreement with the experimental values, whereas others present worse agreement. The calculated fluorescence yield is higher than all theoretical, experimental, and empirical‐fitted values compared, probably because the total radiationless transition rate value calculated in the present work is relatively low.

Martins, Luís↗

Frozen storage of proteins: Use of mannitol to generate a homogenous freeze-concentrate

Therapeutic proteins may be subjected to several freeze–thaw cycles throughout manufacturing and storage. The protein solution composition and the freezing conditions may lead to incomplete ice crystallization in the frozen state. This can also result in freeze-concentrate heterogeneity characterized by multiple glass transition temperatures and protein destabilization. The overall objective was to investigate the potential advantages of including a crystallizing excipient (mannitol) along with a sugar (sucrose or trehalose) for frozen storage. Here, this study showed that the addition of mannitol, a readily crystallizing excipient, facilitated ice crystallization. Inclusion of an isothermal hold during cooling (annealing) maximized the mannitol crystallization and resulted in a homogenous freeze-concentrate of a constant composition characterized by a single glass transition temperature. The role of freezing rate and annealing on both mannitol and ice crystallization were discerned using high intensity synchrotron radiation. The addition of sucrose or trehalose, at an appropriate concentration, stabilized the protein. The mannitol to sugar ratio (3:1 or 1:1, 5 % w/v) was optimized to selectively cause maximal crystallization of mannitol while retaining the sugar amorphous. Human serum albumin (1 mg/mL) in these optimized and annealed compositions did not show any meaningful aggregation, even after multiple freeze–thaw cycles. Thus, in addition to a sugar as a stabilizer, the use of a crystallizing excipient coupled with an annealing step can provide an avenue for frozen storage of proteins.

59 BASIC BIOLOGICAL SCIENCES↗

An Approach for Practical Multiobjective IMRT Treatment Planning

Purpose: To introduce and demonstrate a practical multiobjective treatment planning procedure for intensity-modulated radiation therapy (IMRT) planning. Methods and Materials: The creation of a database of Pareto optimal treatment plans proceeds in two steps. The first step solves an optimization problem that finds a single treatment plan which is close to a set of clinical aspirations. This plan provides an example of what is feasible, and is then used to determine mutually satisfiable hard constraints for the subsequent generation of the plan database. All optimizations are done using linear programming. Results: The two-step procedure is applied to a brain, a prostate, and a lung case. The plan databases created allow for the selection of a final treatment plan based on the observed tradeoffs between the various organs involved. Conclusions: The proposed method reduces the human iteration time common in IMRT treatment planning. Additionally, the database of plans, when properly viewed, allows the decision maker to make an informed final plan selection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗