Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Optimizing Transition-Edge Sensor Design for High Count-Rate Applications

We are developing transition-edge sensor (TES) X-ray detectors optimized for high count-rate applications. These devices are fabricated on thick (300 {mu}m) Si substrates, resulting in a 20 times increase in thermal conductance to the heat sink compared to our conventional membrane isolated TES's. Operating a TES with higher heat sink conductance requires 4.5 times more bias current. This results in a 2.7 times increase in {beta}, the logarithmic derivative of resistance with respect to current. Noise measurements show a lower limit on the TES excess noise scales as (2{beta}){sup 1/2}, consistent with the near-equilibrium, non-linear expansion of the Ohmic Johnson noise. This is consistent with our membrane devices though the increased {beta} means the theoretical best attainable resolution is degraded by 25-35%. We have tested devices with different contact geometries between the absorber, and the TES and substrate. This allows us to investigate the loss of athermal phonons to the substrate, which can degrade the resolution. Results show a correlation between the stem contact area and a low-energy tail in the spectral response at 5.9 keV due to the athermal phonon loss. In several devices tested we demonstrate a resolution of 4.1-5.6 eV, coupled with detector time constants as fast as 44 {mu}s, representing an increase in detector response by 7 times compared to the membrane devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pion studies with silicon detectors.

Most probable energy loss in silicon for pions with energies from 365 to 50 mev, examining pion beam behavior through different absorption material thicknesses

MUON↗

Experimental Searches for SuperSymmetry at the Tevatron

At the Tevatron collider, the CDF and DOe experiments are carrying out a wide program of searches for SuperSymmetry. Recent results, based on up to 4 fb{sup -1} of collected data, are presented. No evidence of new physics is found and exclusion limits are extracted for the investigated SUSY phase space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Underlying Event Studies at ATLAS and CDF

Improving our understanding and modeling of the underlying event in high energy collider environment is important for more precise measurements at the LHC. CDF Run II data for the underlying event associated with Drell-Yan lepton pair production and early ATLAS data measuring underlying event activity with respect to the leading transverse momentum track are presented. The data are compared with several QCD Monte Carlo models. It is seen that no current standard Monte Carlo tune adequately describes all the early ATLAS data and CDF data simultaneously. The underlying event observables presented here are particularly important for constraining the energy evolution of multiple parton interaction models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Z{sup '} model for the CDF dijet anomaly

We adopt a bottom-up approach to constructing a new physics model to explain the CDF excess seen in dijets with an associated lepton and missing transverse energy. We find that the 145 GeV broad feature seen by CDF in the dijet invariant mass distribution can be explained by a Z{sup '} boson with a mass of 145 GeV that couples only to first generation quarks. After dijet resonance constraints are considered, a sizeable region of the parameter space favored by the CDF anomaly remains viable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct Mass Limits for Chiral Fourth-Generation Quarks in All Mixing Scenarios

Present limits on chiral fourth-generation quark masses m{sub b}{sup '} and m{sub t}{sup '} are broadly generalized and strengthened by combining both t{sup '} and b{sup '} decays and considering a full range of t{sup '} and b{sup '} flavor-mixing scenarios with the lighter generations (to 1- parallel V{sub 44} parallel {sup 2{approx_equal}}10{sup -13}). Various characteristic mass-splitting choices are considered. With m{sub t}{sup '}>m{sub b}{sup '} we find that CDF Collaboration limits on the b{sup '} mass vary by no more than 10%-20% with any choice of flavor mixing, while for the t{sup '} mass, we typically find stronger bounds, in some cases up to m{sub t}{sup '}>430 GeV. For m{sub b}{sup '}>m{sub t}{sup '}, we find m{sub b}{sup '}>380-430 GeV, depending on the flavor mixing and the size of the m{sub t}{sup '}-m{sub b}{sup '} mass splitting.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results from a Low-Energy Analysis of the CDMS II Germanium Data

We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from weakly interacting massive particles (WIMPs) with masses below {approx}10 GeV/c{sup 2}. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c{sup 2} and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Baryonic Z{sup '} Explanation for the CDF Wjj Excess

The latest CDF anomaly, the excess of dijet events in the invariant-mass window 120-160 GeV in associated production with a W boson, can be explained by a baryonic Z{sup '} model in which the Z{sup '} boson has negligible couplings to leptons. Although this Z{sup '} model is hardly subject to the Drell-Yan constraint from Tevatron, it is constrained by the dijet data from UA2 ({radical}(s)=630 GeV), and the precision measurements at LEP through the mixing with the SM Z boson. We show that under these constraints this model can still explain the excess in the M{sub jj{approx}}120-160 GeV window, as well as the claimed cross section {sigma}(WZ{sup '}){approx}4 pb. Implications at the Tevatron would be the associated production of {gamma}Z{sup '}, ZZ{sup '}, and Z{sup '}Z{sup '} with the Z{sup '}{yields}jj. We show that with tightened jet cuts and improved systematic uncertainties both {gamma}Z{sup '}{yields}{gamma}jj and ZZ{sup '}{yields}l{sup +}l{sup -}jj channels could be useful to probe this model at the Tevatron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resolving small signal measurements in experimental plasma environments using calibrated subtraction of noise signals

The performance of many diagnostic and control systems within fusion and other fields of research are often detrimentally affected by spurious noise signals. This is particularly true for those (such as radiation or particle detectors) working with very small signals. Common sources of radiated and conducted noise in experimental fusion environments include the plasma itself and instrumentation. The noise complicates data analysis, as illustrated by noise on signals measured with the heavy ion beam probe (HIBP) installed on the Madison Symmetric Torus. The noise is time-varying and often exceeds the secondary ion beam current (in contrast with previous applications). Analysis of the noise identifies the dominant source as photoelectric emission from the detectors induced by ultraviolet light from the plasma. This has led to the development of a calibrated subtraction technique, which largely removes the undesired temporal noise signals from data. The advantages of the technique for small signal measurement applications are demonstrated through improvements realized on HIBP fluctuation measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ Determination of the ATLAS Muon Performance

The ATLAS detector allows for the precise and efficient reconstruction of muons. Muon tracks are reconstructed with 97% efficiency with a momentum resolution of approximately 2-3% over most of the kinematic range and better than 10% for transverse momenta up to 1 TeV and |eta|<2.7. We present methods to measure the performance of the muon identification during the operation of the ATLAS detector using muons from Z and J/psi decays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A universal setup for active control of a single-photon detector

The influence of bright light on a single-photon detector has been described in a number of recent publications. The impact on quantum key distribution (QKD) is important, and several hacking experiments have been tailored to fully control single-photon detectors. Special attention has been given to avoid introducing further errors into a QKD system. We describe the design and technical details of an apparatus which allows to attack a quantum-cryptographic connection. This device is capable of controlling free-space and fiber-based systems and of minimizing unwanted clicks in the system. With different control diagrams, we are able to achieve a different level of control. The control was initially targeted to the systems using BB84 protocol, with polarization encoding and basis switching using beamsplitters, but could be extended to other types of systems. We further outline how to characterize the quality of active control of single-photon detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated semiconductor quantum dot scintillation detector: Ultimate limit for speed and light yield

Here, a picosecond-range timing of charged particles and photons is a long-standing challenge for many high-energy physics, biophysics, medical and security applications. We present a design, technological pathway and challenges, and some properties important for realization of an ultrafast high-efficient room-temperature semiconductor scintillator based on self-assembled InAs quantum dots (QD) embedded in a GaAs matrix. Low QD density (<; 10 15 cm -3 ), fast (~5 ps) electron capture, luminescence peak redshifted by 0.2-0.3 eV from GaAs absorption edge with fast decay time (0.5-1 ns) along with the efficient energy transfer in the GaAs matrix (4.2 eV/pair) allows for fabrication of a semiconductor scintillator with the unsurpassed performance parameters. The major technological challenge is fabrication of a large volume (> 1 cm 3 ) of epitaxial QD medium. This requires multiple film separation and bonding, likely using separate epitaxial films as waveguides for improved light coupling. Compared to traditional inorganic scintillators, the semiconductor-QD based scintillators could have about 5x higher light yield and 20x faster decay time, opening a way to gamma detectors with the energy resolution better than 1% and sustaining counting rates MHz. Picosecond-scale timing requires segmented low-capacitance photodiodes integrated with the scintillator. For photons, the proposed detector inherently provides the depth-of-interaction information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Remote Method for Estimation of Contamination Levels of Reactor Equipment - 13175

Projects for decommissioning of shutdown reactors and reactor facilities carried out in several countries, including Russia. In the National Research Centre 'Kurchatov Institute' decontamination and decommissioning of the research reactor MR (Material Testing Reactor) has been initiated. The research reactor MR has a long history and consists of nine loop facilities for experiments with different kinds of fuel. During the operation of main and auxiliary equipment of reactors it was subjected to strong radioactive contamination. The character of this contamination requires individual strategies for the decontamination work. This requires information about the character of the distribution of radioactive contamination of equipment in the premises. A detailed radiation survey of these premises using standard dosimetric equipment is almost impossible because of high levels of radiation and high-density of the equipment that does not allow identifying the most active fragments using standard tools of measurement. The problem can be solved using the method of remote measurements of distribution of radioactivity with help of the collimated gamma-ray detectors. For radiation surveys of the premises of loop installations remotely operated spectrometric collimated system was used [1, 2, 3]. As a result of the work, maps of the distribution of activity and dose rate for surveyed premises were plotted and superimposed on its photo. The new results of measurements in different areas of the reactor and at its loop installations, with emphasis on the radioactive survey of highly-contaminated samples, are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Heavy-Baryons and Hyperfine Mass-Splittings: Analysis from QCD Rum Rules

We extract directly the charmed and bottom heavy-baryons (spin 1/2 and 3/2) masssplittings due to SU(3) breaking using double ratios of QCD spectral sum rules (QSSR) in full QCD. We deduce M{sub {Omega}{sub b}} = 6078.5(27.4) MeV which agrees with the recent CDF data but disagrees by 2.4{sigma} with the one from D0. Predictions of the {Xi}{sub Q}' and of the spectra of spin 3/2 baryons containing one or two strange quark are given in Table 1. Predictions of the hyperfine splittings {Omega}{sub Q}*-{Omega}{sub Q} and {Xi}{sub Q}*-{Xi}{sub Q} are also given in Table 2.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New determination of the N-{Delta}(1232) axial form factors from weak pion production and coherent pion production off nuclei at T2K and MiniBooNE energies revisited

We re-evaluate our model predictions in Phys. Rev. D 79, 013002 (2009) for different observables in neutrino induced coherent pion production. This comes as a result of the new improved fit to old bubble chamber data of the dominant axial C{sub 5}{sup A} nucleon-to-Delta form factor. We find an increase of 20%{approx}30% in the values for the total cross sections. Uncertainties induced by the errors in the determination of C{sub 5}{sup A} are computed. Our new results turn out to be compatible within about 1{sigma} with the former ones. We also stress the existing tension between the recent experimental determination of the {sigma}(CCcoh{pi}{sup +})/{sigma}(NCcoh{pi}{sup 0}) ratio by the SciBooNE Collaboration and the theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino-impact ionization of atoms in searches for neutrino magnetic moment

The ionization of atomic electrons by scattering of neutrinos is revisited. This process is the one studied in the experimental searches for a neutrino magnetic moment using germanium detectors. Current experiments are sensitive to the ionization energy comparable with the atomic energies, and the effects of the electron binding should be taken into account. We find that the so-called stepping approximation to the neutrino-impact ionization is in fact exact in the semiclassical limit and also that the deviations from this approximation are very small already for the lowest bound Coulomb states. We also consider the effects of electron-electron correlations and argue that the resulting corrections to the ionization of independent electrons are quite small. In particular, we estimate that in germanium these are at a 1% level at the energy transfer down to a fraction of keV. Exact sum rules are also presented as well as analytical results for a few lowest hydrogenlike states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗