Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Uncertainty Quantification Analysis of Both Experimental and CFD Simulation Data of a Bench-scale Fluidized Bed Gasifier

Adequate assessment of the uncertainties in modeling and simulation is becoming an integral part of the simulation based engineering design. The goal of this study is to demonstrate the application of non-intrusive Bayesian uncertainty quantification (UQ) methodology in multiphase (gas-solid) flows with experimental and simulation data, as part of our research efforts to determine the most suited approach for UQ of a bench scale fluidized bed gasifier. UQ analysis was first performed on the available experimental data. Global sensitivity analysis performed as part of the UQ analysis shows that among the three operating factors, steam to oxygen ratio has the most influence on syngas composition in the bench-scale gasifier experiments. An analysis for forward propagation of uncertainties was performed and results show that an increase in steam to oxygen ratio leads to an increase in H2 mole fraction and a decrease in CO mole fraction. These findings are in agreement with the ANOVA analysis performed in the reference experimental study. Another contribution in addition to the UQ analysis is the optimization-based approach to guide to identify next best set of additional experimental samples, should the possibility arise for additional experiments. Hence, the surrogate models constructed as part of the UQ analysis is employed to improve the information gain and make incremental recommendation, should the possibility to add more experiments arise. In the second step, series of simulations were carried out with the open-source computational fluid dynamics software MFiX to reproduce the experimental conditions, where three operating factors, i.e., coal flow rate, coal particle diameter, and steam-to-oxygen ratio, were systematically varied to understand their effect on the syngas composition. Bayesian UQ analysis was performed on the numerical results. As part of Bayesian UQ analysis, a global sensitivity analysis was performed based on the simulation results, which shows that the predicted syngas composition is strongly affected not only by the steam-to-oxygen ratio (which was observed in experiments as well) but also by variation in the coal flow rate and particle diameter (which was not observed in experiments). The carbon monoxide mole fraction is underpredicted at lower steam-to-oxygen ratios and overpredicted at higher steam-to-oxygen ratios. The opposite trend is observed for the carbon dioxide mole fraction. These discrepancies are attributed to either excessive segregation of the phases that leads to the fuel-rich or -lean regions or alternatively the selection of reaction models, where different reaction models and kinetics can lead to different syngas compositions throughout the gasifier. To improve quality of numerical models used, the effect that uncertainties in reaction models for gasification, char oxidation, carbon monoxide oxidation, and water gas shift will have on the syngas composition at different grid resolution, along with bed temperature were investigated. The global sensitivity analysis showed that among various reaction models employed for water gas shift, gasification, char oxidation, the choice of reaction model for water gas shift has the greatest influence on syngas composition, with gasification reaction model being second. Syngas composition also shows a small sensitivity to temperature of the bed. The hydrodynamic behavior of the bed did not change beyond grid spacing of 18 times the particle diameter. However, the syngas concentration continued to be affected by the grid resolution as low as 9 times the particle diameter. This is due to a better resolution of the phasic interface between the gases and solid that leads to stronger heterogeneous reactions. This report is a compilation of three manuscripts published in peer-reviewed journals for the series of studies mentioned above.

01 COAL, LIGNITE, AND PEAT↗

A modified time-of-flight method for precise determination of high speed ratios in molecular beams

Time-of-flight (TOF) is a standard experimental technique for determining, among others, the speed ratio S (velocity spread) of a molecular beam. The speed ratio is a measure for the monochromaticity of the beam and an accurate determination of S is crucial for various applications, for example, for characterising chromatic aberrations in focussing experiments related to helium microscopy or for precise measurements of surface phonons and surface structures in molecular beam scattering experiments. For both of these applications, it is desirable to have as high a speed ratio as possible. Molecular beam TOF measurements are typically performed by chopping the beam using a rotating chopper with one or more slit openings. The TOF spectra are evaluated using a standard deconvolution method. However, for higher speed ratios, this method is very sensitive to errors related to the determination of the slit width and the beam diameter. The exact sensitivity depends on the beam diameter, the number of slits, the chopper radius, and the chopper rotation frequency. We present a modified method suitable for the evaluation of TOF measurements of high speed ratio beams. The modified method is based on a systematic variation of the chopper convolution parameters so that a set of independent measurements that can be fitted with an appropriate function are obtained. We show that with this modified method, it is possible to reduce the error by typically one order of magnitude compared to the standard method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Densely Aligned Graphene Nanoribbon Arrays and Bandgap Engineering

Graphene has attracted great interest for future electronics due to its high mobility and high thermal conductivity. However, a two-dimensional graphene sheet behaves like a metal, lacking a bandgap needed for the key devices components such as field effect transistors (FETs) in digital electronics. It has been shown that, partly due to quantum confinement, graphene nanoribbons (GNRs) with ~2 nm width can open up sufficient bandgaps and evolve into semiconductors to exhibit high on/off ratios useful for FETs. However, a challenging problem has been that, such ultra-narrow GNRs (~2 nm) are difficult to fabricate, especially for GNRs with smooth edges throughout the ribbon length. Despite high on/off ratios, these GNRs show very low mobility and low on-state conductance due to dominant scattering effects by imperfections and disorders at the edges. Wider GNRs (>5 nm) show higher mobility, higher conductance but smaller bandgaps and low on/off ratios undesirable for FET applications. It is highly desirable to open up bandgaps in graphene or increase the bandgaps in wide GNRs to afford graphene based semiconductors for high performance (high on-state current and high on/off ratio) electronics. Large scale ordering and dense packing of such GNRs in parallel are also needed for device integration but have also been challenging thus far. It has been shown theoretically that uniaxial strains can be applied to a GNR to engineer its bandgap. The underlying physics is that under uniaxial strain, the Dirac point moves due to stretched C-C bonds, leading to an increase in the bandgap of armchair GNRs by up to 50% of its original bandgap (i.e. bandgap at zero strain). For zigzag GNRs, due to the existence of the edge states, changes of bandgap are smaller under uniaxial strain and can be increased by ~30%. This work proposes a novel approach to the fabrication of densely aligned graphene nanoribbons with highly smooth edges afforded by anisotropic etching and uniaxial strain for bandgap engineering of GNRs towards high on/off ratio and high on-state current GNR devices. First, we will develop a novel approach for the fabrication of high density GNR arrays (pitch <50 nm, tunable down to 30nm) with pre-defined edge orientation and smooth edges using a free standing nano-mask derived from diblock copolymer assembly for patterning of graphene sheets. Anisotropic graphene edges will be developed to afford smooth edges along crystallographic lattice directions. Then, we will fabricate GNR devices on flexible substrates and apply uniaxial strain to engineer the bandgap of the GNRs. The bandgap of GNRs could be increased by up to 50% under uniaxial strain according to theoretical calculations and will be investigated through electrical transport measurements. Micro-Raman spectroscopy of single GNRs and parallel arrays will be used to probe and quantify the uniaxial strain. Electrical measurements will be used to probe the on/off ratio of GNR FET devices and confirm the bandgap tuning effects. Finally, we plan to use dense parallel arrays of GNRs to demonstrate strained GNR field effect transistors with high on/off ratios and high on-state current, and compare strained GNR FETs with carbon nanotube and Si based field effect transistor (FET) devices.

42 ENGINEERING↗

Photovoltaic Mini-Module Soiling Stations: Cooperative Research and Development (Final Report)

Photovoltaic (PV) panels can become soiled due to a variety of environmental factors. This soiling reduces the amount of light reaching the cells and thus their energy output. The ratio of actual output of the soiled device that of a clean device is known as the soiling ratio. The daily change in soiling ratio is known as the soiling rate. To study soiling for different glass coatings. Two soiling stations were fabricated. The stations were designed to monitor the short-circuit current of PV cells encapsulated with glass featuring different coatings and measure the daily soiling ratio with a pair of reference cells, one of which is automatically brushed daily. This work meets the need to understand how the glass coatings perform in additional environments. The stations are designed to quantify both the soiling ratio (the ratio between actual/expected photovoltaic panel power output) as well as differences in anti-soiling performance of different glass coatings. The design of the dirty/clean reference cell system is described by Toth et al. The soiling ratio is calculated by calculating the average irradiance measured within one hour of solar noon by each of the reference cells and then taking the ratio of these daily near-noon averages. The soiling ratio time series for the station deployed in Georgia is shown in Figure 1. This figure shows that the soiling ratio at the site has not yet fallen below 0.99, indicating that peak daily soiling losses have been below 1%. The site was chosen because it is thought to be affected by pollen soiling. With continued monitoring over the course of at least a full year, we expect to be able to observe and quantify pollen soiling events.

14 SOLAR ENERGY↗

The choking pressure ratio of a critical flow venturi

The critical flow venturi has many important applications in the measurement and control of gas flow. In many of these applications, it is desirable to minimize the pressure loss required to maintain critical flow conditions. The performance of the venturi may be characterized by the ratio of outlet static pressure to inlet total pressure just sufficiently small to produce critical flow. This ratio is called choking pressure ratio. The optimization of diffusers for critical flow venturis is discussed and suggestions for designs practice are presented. Test results are given for six different diffuser configurations, and a comparison is made with data on 11 configurations from other investigators. It is shown that, for the small divergence angles considered, a simply defined diffuser effectiveness parameter is approximately independent of flow conditions and may be used to predict choking pressure ratio.

Hillbrath, H. S.↗

Performance Improvements to the Neutron Imaging System at the National Ignition Facility

A team headed by LANL and including many members from LLNL and NSTec LO and NSTec LAO fielded a neutron imaging system (NIS) at the National Ignition Facility at the start of 2011. The NIS consists of a pinhole array that is located 32.5 cm from the source and that creates an image of the source in a segmented scintillator 28 m from the source. The scintillator is viewed by two gated, optical imaging systems: one that is fiber coupled, and one that is lens coupled. While there are a number of other pieces to the system related to pinhole alignment, collimation, shielding and data acquisition, those pieces are discussed elsewhere and are not relevant here. The system is operational and has successfully obtained data on more that ten imaging shots. This remainder of this whitepaper is divided in five main sections. In Section II, we identify three critical areas of improvement that we believe should be pursued to improve the performance of the system for future experiments: spatial resolution, temporal response and signal-to-noise ratio. In Section III, we discuss technologies that could be used to improve these critical performance areas. In Section IV, we describe a path to evolve the current system to achieve improved performance with minimal impact on the ability of the system to operate on shots. In Section V, we discuss the abilities, scope and timescales of the current teams and the Commissariat energie atomique (CEA). In Section VI, we summarize and make specific recommendations for collaboration on improvements to the NIS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tuning the Co/Fe ratio in BaCo x Fe 0.8– x Zr 0.1 Y 0.1 O 3– δ , a promising triple ionic and electronic conducting oxide, to boost electrolysis and fuel cell performance

The triple conducting oxide BaCo 0.4 Fe 0.4 Zr 0.1 Y0.1O 3–δ (BCFZY4411), which accommodates simultaneous transport of protons, oxygen ions, and p-type electronic carriers, has been intensively investigated in recent years as a high-performance positive electrode material for fuel cell and electrolysis applications. The heavy Co and Fe-based transition metal doping in BCFZY4411 ensures adequate electrical conductivity while the multiple oxidation states of Co and Fe assist the electrocatalytic and redox ability. Despite the considerable role of Co and Fe transition metal doping in controlling electrochemical activity, however, the study of alternative BCFZY compositions with varying Co/Fe ratios has not yet been pursued. Here, we evaluate the electrochemical performance of a series of BaCo x Fe 0.8–x Zr 0.1 Y0.1O 3–δ compositions with varying Co/Fe ratio (x = 0.1, 0.2, 0.4, 0.6, 0.7) and use oxygen ion tracer diffusion and in situ high-temperature X-ray diffraction to investigate the effect of Co/Fe ratio on electrocatalytic activity, electronic conductivity, oxygen ion incorporation and transport kinetics, and thermomechanical behavior. We find that Co-rich BCFZY7111 yields the highest performance due to exceptionally high oxygen vacancy diffusion and shows a lower and more linear thermal expansion behavior compared to Fe-rich compositions. A protonic ceramic button cell incorporating a BCFZY7111 positive electrode yields a peak power density of 695 mW cm –2 under fuel cell mode and an electrolysis current density of 1976 mA cm –2 at 1.4 V at 600 °C, underscoring the promise of this new BCFZY electrode composition.

30 DIRECT ENERGY CONVERSION↗

Thrust performance of a variable-geometry, divergent exhaust nozzle on a turbojet engine at altitude

A variable geometry, low aspect ratio, nonaxisymmetric, two dimensional, convergent-divergent exhaust nozzle was tested at simulated altitude on a turbojet engine to obtain baseline axial, dry thrust performance over wide ranges of operating nozzle pressure ratios, throat areas, and internal expansion area ratios. The thrust data showed good agreement with theory and scale model test results after the data were corrected for seal leakage and coolant losses. Wall static pressure profile data were also obtained and compared with one dimensional theory and scale model data. The pressure data indicate greater three dimensional flow effects in the full scale tests than with models. The leakage and coolant penalties were substantial, and the method to determine them is included.

Straight, D. M.↗

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter

We present an initial investigation into the performance of a multicollector inductively coupled plasmamass spectrometer equipped with a pre-mass filter (Neoma MC-ICP-MS/MS) for making plutonium (Pu) isotope ratio measurements on solutions containing low level (i.e., pg mL –1 ) Pu concentrations. This assessment was achieved by comparison of the 240 Pu/ 239 Pu, 241 Pu/ 239 Pu, and 242 Pu/ 239 Pu ratios attained over a one month period on the MC-ICP-MS/MS with the long-term (∼1 year) performance observed on the predecessor MC-ICP-MS (Neptune Plus) instrument each equipped with an equipped with an APEXΩ desolvating nebulizer for repeated measurements of certified reference materials from New Brunswick Program Office (NBL PO) CRM 136a and CRM 137. The MC-ICP-MS/MS performance of repeated measurement of CRM 136a (n = 20) resulted in mean values of 240 Pu/ 239 Pu = 0.1448 ± 0.0006, 241 Pu/ 239 Pu = 0.00371 ± 0.00006, and 242 Pu/ 239 Pu = 0.00682 ± 0.00006 (k = 2). The CRM 137 (n = 20), analyzed during the same analytical sessions, produced mean values for 240 Pu/ 239 Pu = 0.2414 ± 0.0006, 241 Pu/ 239 Pu = 0.00464 ± 0.00007, and 242 Pu/ 239 Pu = 0.0157 ± 0.0001 (k = 2). These results closely align with the certificate values for CRM 136a and CRM 137 and are within the k = 2 envelopes defined by the long-term performance of the traditional MC-ICP-MS approach (Neptune Plus). Examination of the performance of the various Pu isotope ratios as a function of total Pu content revealed accurate results (<3% relative difference, or RD) above ∼50 fg total Pu. The results presented here demonstrate the capability of the MC-ICP-MS/MS making accurate and precise low level Pu isotopic measurements. While the intent of this work was not to investigate the functionality of the collision cell, the pre-mass filter was employed. Future studies are warranted to investigate the entire capability of the MC-ICP-MS/MS collision cell and pre-cell mass filter optimization for performing low level Pu isotope measurements, even in mixed matrix samples.

CRM↗

Effects of molar expansion ratio of fuels on engine efficiency

Fuel properties have a strong impact on the efficiency of internal combustion engines. Contrary to other physical and thermochemical fuel properties, the molar expansion ratio is normally ignored. Molar expansion ratio is the ratio of number of moles of the products to the reactants. In this work, the impact of the fuel’s molar expansion ratio on engine efficiency is investigated. Findings are based on simulations of a spark ignition engine using different fuels (standard fuels and user-defined fuels) and different dilution ratios. Simulations without heat transfer and friction were performed first. The combustion then takes place at top dead center with a very short combustion duration to approach the ideal Otto cycle. The heat transfer and friction were then added step by step. From this analysis, it could be concluded that the heat loss and friction work decrease as molar expansion ratio increases. The gross indicated and brake thermal efficiencies thus increase. User-defined fuels with different molar expansion ratio, but the same physical and thermochemical properties were then employed. The simulated results showed that the brake thermal efficiency increases by around 1.15% with an increase in molar expansion ratio of 0.02 compared to a fuel with a molar expansion ratio of unity. Lastly, the simulation was also done with air and exhaust gas recirculation dilution.

42 ENGINEERING↗

Recent progress toward an advanced spherical torus operating point in NSTX

Progress in the development of integrated advanced ST plasma scenarios in NSTX (Ono et al., 2000 Nucl. Fusion 40 557) is reported. Recent high-performance plasmas in NSTX following lithium coating of the plasma facing surfaces have achieved higher elongation and lower internal inductance than previously. Analysis of the thermal confinement in these lithiumized discharges shows a stronger plasma current and weaker toroidal field dependence than in previous ST confinement scaling studies; the ITER-98(y, 2) scaling expression describes these scenarios reasonably well. Analysis during periods free of MHD activity has shown that the reconstructed current profile can be understood as the sum of pressure driven, inductive and neutral beam driven currents, without requiring any anomalous fast-ion transport. Non-inductive fractions of 65–70%, and βP > 2, have been achieved at lower plasma current. Some of these low-inductance discharges have a significantly reduced no-wall βN limit, and often have βN at or near the with-wall limit. Coupled m/n = 1/1 + 2/1 kink/tearing modes can limit the sustained β values when rapidly growing ideal modes are avoided. A βN controller has been commissioned and utilized in sustaining high-performance plasmas. 'Snowflake' divertors compatible with high-performance plasmas have been developed. Scenarios with significantly larger aspect ratios have also been developed, in support of next-step ST devices. Furthermore, these NSTX plasmas have many characteristics required for next-step ST devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

WE-AB-207A-10: Transmission Characteristics of a Two Dimensional Antiscatter Grid Prototype for CBCT

Purpose: Scattered radiation remains to be a major contributor to image quality degradation in CBCT. To address the scatter problem, a focused, 2D antiscatter grid (2DASG) prototype was designed, and fabricated using additive manufacturing processes. Its scatter and primary transmission properties were characterized using a linac mounted CBCT system. Methods: The prototype 2DASG was composed of rectangular grid holes separated by tungsten septa, and has a grid pitch of 2.91 mm, grid ratio of 8, and a septal thickness of 0.1 mm. Each grid hole was aligned or focused towards the x-ray source in half-fan (i.e. offset detector) geometry of the Varian TrueBeam CBCT system. Scatter and primary transmission experiments were performed by using acrylic blocks and the beam-stop method. Transmission properties of a radiographic ASG (1DASG) (grid ratio of 10) was also performed by using the identical setup. Results: At 30 cm phantom thickness, scatter to primary ratio (SPR) was 4.51 without any ASG device. SPR was reduced to 1.28 with 1DASG, and it was further reduced to 0.28 with 2DASG. Scatter transmission fraction (Ts) of 1DASG was 21%, and Ts was reduced to 5.8% with 2DASG. The average primary transmission fraction (Tp) of 1DASG was 70.6%, whereas Tp increased to 85.1% with 2DASG. Variation of Tp across 40 cm length (the long axis of flat panel detector) was 2.6%. Conclusion: When compared to conventional ASGs, the focused 2DASG can vastly improve scatter suppression and primary transmission performance. Due to precise alignment of 2DASG’s grid holes with respect to beam divergence, high degree of primary transmission through the 2DASG was maintained across the full length of the prototype. We strongly believe that robust scatter rejection and primary transmission characteristics of our 2DASG can translate into both improved quantitative accuracy and soft tissue resolution in linac mounted CBCT systems.

60 APPLIED LIFE SCIENCES↗

Hypofractionated Versus Standard Radiation Therapy With or Without Temozolomide for Older Glioblastoma Patients

Purpose: Older patients with newly diagnosed glioblastoma have poor outcomes, and optimal treatment is controversial. Hypofractionated radiation therapy (HRT) is frequently used but has not been compared to patients receiving standard fractionated radiation therapy (SRT) and temozolomide (TMZ). Methods and Materials: We conducted a retrospective analysis of patients ≥65 years of age who received radiation for the treatment of newly diagnosed glioblastoma from 1994 to 2013. The distribution of clinical covariates across various radiation regimens was analyzed for possible selection bias. Survival was calculated using the Kaplan-Meier method. Comparison of hypofractionated radiation (typically, 40 Gy/15 fractions) versus standard fractionation (typically, 60 Gy/30 fractions) in the setting of temozolomide was conducted using Cox regression and propensity score analysis. Results: Patients received SRT + TMZ (n=57), SRT (n=35), HRT + TMZ (n=34), or HRT (n=9). Patients receiving HRT were significantly older (median: 79 vs 69 years of age; P<.001) and had worse baseline performance status (P<.001) than those receiving SRT. On multivariate analysis, older age (adjusted hazard ratio [AHR]: 1.06; 95% confidence interval [CI]: 1.01-1.10, P=.01), lower Karnofsky performance status (AHR: 1.02; 95% CI: 1.01-1.03; P=.01), multifocal disease (AHR: 2.11; 95% CI: 1.23-3.61, P=.007), and radiation alone (vs SRT + TMZ; SRT: AHR: 1.72; 95% CI: 1.06-2.79; P=.03; HRT: AHR: 3.92; 95% CI: 1.44-10.60, P=.007) were associated with decreased overall survival. After propensity score adjustment, patients receiving HRT with TMZ had similar overall survival compared with those receiving SRT with TMZ (AHR: 1.10, 95% CI: 0.50-2.4, P=.82). Conclusions: With no randomized data demonstrating equivalence between HRT and SRT in the setting of TMZ for glioblastoma, significant selection bias exists in the implementation of HRT. Controlling for this bias, we observed similar overall survival for HRT and SRT with concurrent TMZ among elderly patients, suggesting the need for a randomized trial to compare these regimens directly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient Data Compression for 3D Sparse TPC via Bicephalous Convolutional Autoencoder

Real-time data collection and analysis in large experimental facilities present a great challenge across multiple domains, including high energy physics, nuclear physics, and cosmology. To address this, machine learning (ML)-based methods for real-time data compression have drawn significant attention. However, unlike natural image data, such as CIFAR and ImageNet that are relatively small-sized and continuous, scientific data often come in as three-dimensional 3D data volumes at high rates with high sparsity (many zeros) and non-Gaussian value distribution. This makes direct application of popular ML compression methods, as well as conventional data compression methods, suboptimal. To address these obstacles, this work introduces a dual-head autoencoder to resolve sparsity and regression simultaneously, called Bicephalous Convolutional AutoEncoder (BCAE). This method shows advantages both in compression fidelity and ratio compared to traditional data compression methods, such as MGARD, SZ, and ZFP. To achieve similar fidelity, the best performer among the traditional methods can reach only half the compression ratio of BCAE. Moreover, a thorough ablation study of the BCAE method shows that a dedicated segmentation decoder improves the reconstruction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of buoyancy and power design parameters on hybrid airship performance

The effects of several design parameters on the performance of hybrid airships having rotors and propellers were examined with a simple mathematical model. The parameters included buoyancy ratio, Froude number, ratio of rotor power to total power, and rotor shaft tilt. Performance variations resulting from changes in these parameters were calculated, and are presented and discussed. Performance quantities included best climb rate, equivalent vehicle L/D, and maximum speed. Performance at all speeds between hover and maximum speed was found to be sensitive to power distribution between rotors and propellers, and to rotor shaft tilt.

Talbot, P. D.↗

A Computational and Experimental Investigation of a Three-Dimensional Hypersonic Scramjet Inlet Flow Field

A combined computational and experimental parametric study of the internal aerodynamics of a generic three dimensional sidewall compression scramjet inlet configuration was performed. The study was designed to demonstrate the utility of computational fluid dynamics as a design tool in hypersonic inlet flow fields, to provide a detailed account of the nature and structure of the internal flow interactions, and to provide a comprehensive surface property and flow field database to determine the effects of contraction ratio, cowl position, and Reynolds number on the performance of a hypersonic scramjet inlet configuration.

Holland, Scott Douglas↗

Design, development, and test of a laser velocimeter for a small 8:1 pressure ratio centrifugal compressor

The instrument was designed as a diagnostic tool for the basic fluid dynamics of the inducer, impeller, and diffuser regions of this type compressor. The LV instrumentation was optimized to measure instantaneous velocities up to approximately 500 m/s, measured in absolute coordinates, within the rotating compressor impeller and in the two dimensional radial plane of the diffuser. Some measurements were made within the diffuser and the impeller inlet flows; however, attempts to make detailed measurements of the velocity field were not successful. Difficulties in maintaining high seed particle rates within the probe volume and the improper operation of the blade gating optics may explain the lack of success. Recommendations are made to further pursue these problems. At 100% speed the stage attained a total static pressure ratio of 7.5:1 at 75% total-static efficiency. Flow range from choke-to-surge was 6.8% of choking mass flow rate. Performance was lower than the design intent of 8:1 pressure ratio at 77% efficiency and 12% flow range. Detailed measurements of the stage components are presented which show the reasons for the stage performance deficiencies.

Dolan, F. X.↗

Theoretical Performance of Liquid Hydrogen with Liquid Oxygen as a Rocket Propellant

Theoretical rocket performance for both equilibrium and frozen composition during expansion was calculated for the propellant combination liquid hydrogen and liquid oxygen at four chamber pressures (60, 150, 300, and 600 lb/sq in. abs) and a wide range of pressure ratios (1 to 4000) and oxidant-fuel ratios (1.190 to 39.683). Data are given to estimate performance parameters at chamber pressures other than those for which data are tabulated. The parameters included are specific impulse, specific impulse in vacuum, combustion-chamber temperature, nozzle-exit temperature, molecular weight, molecular-weight derivatives, characteristic velocity, coefficient of thrust, ratio of nozzle-exit area to throat area, specific heat at constant pressure, isentropic exponent, viscosity, thermal conductivity, Mach number, and equilibrium gas compositions.

Gordon, Sanford↗