Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

NASA’s Surface Deformation and Change Mission Study

The National Academies of Science, Engineering and Medicine 2017 Decadal Survey of Earth Science and Applications identified geodetic measurements of surface deformation and related change as one of the top five “observables” to be prioritized in NASA’s future program. In response, NASA commissioned a multi-center Surface Deformation and Change(SDC) team to perform a five year study of mission architectures that would support SDC observables and provide the most value to the diverse science and applications communities it serves. The study is being conducted in phases, in which the science and applications capabilities identified in the Decadal Survey are refined, candidate architectures and associated technologies to support these needs are identified, architectures are assessed against a science value framework specific to SDC, and recommendations to NASA are made. Ultimately, NASA will decide which amongst these recommendations will proceed to mission formulation. As synthetic aperture radar (SAR) was identified as the prime sensor technology to satisfy SDC observational needs, a key component of the SDC study is to assess the current state of the art in SAR sensor and supporting technology. The number of SAR systems, both civil and commercial, is growing rapidly, requiring that mission architectures not only consider technology, but availability of data from other missions, possible partnerships or collaborations, and even data purchase. The mechanism for assessment involves development of an end-to-end science performance evaluation tool for multi-satellite con-stellations, which feeds into a science value framework that con-siders science performance, technological programmatic risks, and cost. This paper will present an overview of the ongoing study including the candidate architectures and the technology road map needed to achieve the objectives of the mission.

Stephen Horst↗

Understanding the Effect of Baseline Modeling Implementation Choices on Analysis of Demand Response Performance

Accurate evaluation of the performance of buildings participating in Demand Response (DR) programs is critical to the adoption and improvement of these programs. Typically, we calculate load sheds during DR events by comparing observed electric demand against counterfactual predictions made using statistical baseline models. Many baseline models exist and these models can produce different shed calculations. Moreover, modelers implementing the same baseline model can make different modeling implementation choices, which may affect shed estimates. In this work, using real data, we analyze the effect of different modeling implementation choices on shed predictions. We focused on five issues: weather data source, resolution of data, methods for determining when buildings are occupied, methods for aligning building data with temperature data, and methods for power outage filtering. Results indicate sensitivity to the weather data source and data filtration methods as well as an immediate potential for automation of methods to choose building occupied modes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-Use Fleet Evaluation of Fast-Charge Battery Electric Transit Buses

With support from the U.S. Department of Energy's Vehicle Technologies Office, the National Renewable Energy Laboratory (NREL) conducts real-world performance evaluations of advanced medium- and heavy-duty fleet vehicles. Evaluation results can help vehicle manufacturers fine-tune their designs and assist fleet managers in selecting fuel-efficient, low-emission vehicles that meet their economic and operational goals. In 2015, NREL launched an in-service evaluation of 12 battery electric buses (BEBs) compared to conventional compressed natural gas (CNG) buses operated by Foothill Transit in West Covina, California. The study aims to improve understanding of the overall usage and effectiveness of fast-charge BEBs and associated charging infrastructure in transit operation. To date, NREL researchers have analyzed more than 148,000 km of in-use operational data, including driving and charging events. Foothill Transit purchased the BEBs with grant funding from the Federal Transit Administration's Transit Investments for Greenhouse Gas and Energy Reduction Program.

33 ADVANCED PROPULSION SYSTEMS↗

ATS-6 engineering performance report. Volume:Program and systems summaries: Mechanical and thermal details

The overall mission and spacecraft systems, testing, and operations are summarized. The mechanical subsystems are reviewed, encompassing mechanical design requirements; separation and deployment mechanisms; design and performance evaluation; and the television camera reflector monitor. Thermal control and contamination are discussed in terms of thermal control subsystems, design validation, subsystems performance, the advanced flight experiment, and the quartz-crystal microbalance contamination monitor.

Wales, R. O.↗

Status of Electronics Upgrades to the LANL Green is Clean Phoswich Detector Systems - 16419

Los Alamos National Laboratory radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to assay and verify that GIC candidate waste meets free release disposal requirements. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The crystals are set in an oxygen-free high-conductivity copper housing with a very thin (0.025 mm) aluminum entrance window. The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. These electronic modules provide the buffering, amplification, and pulse shape analyzer needed for the proper presentation of signals to the custom Phosmux router module. The router module separates the sodium iodide and cesium iodide signals by their rise times and transfers this information into the computer-mounted multichannel analyzer, a Canberra Model S-100 system. While these NIM Bin counting electronics configurations have been effective for approximately 20 years of operation, they are bulky requiring numerous modules per detector and the important Phosmux module is no longer manufactured by LANL. Modern advancement of commercial counting electronics now offer more compact options for equivalent detector signal processing. A pulse shape discriminator module, the DGF Pixie-4, made by XIA LLC, has been identified that can replace the majority of the original NIM bin electronics in a much more compact chassis - one Pixie-4 replaces four NIM amplifiers and four NIM PSAs and fits in a small National Instruments{sup TM} chassis. Thus, LANL has initiated a system upgrade project to replace the historic NIM electronics with the XIA Pixie4 and associated configuration software. The hardware for one Phoswich systems has been procured for the project and the configuration software, customized for the LANL Phoswich detector application, has been written by the manufacturer. Initial setup and optimization of the Pixie-4 configuration has been performed. Qualitative and quantitative baseline comparisons to the NIM electronics has been performed. Good agreement of key low energy gamma lines between the systems has allowed 'Proof of Concept' to be concluded. Further optimization and performance evaluations are in progress. Modifications to the LabVIEW{sup TM} based operating software (originally written by VI Control Systems Ltd.) are being performed by a LANL LabVIEW{sup TM} programmer to accommodate the electronics upgrade. A new LabVIEW{sup TM} interface to control the Pixie-4 has already been developed. Final optimization and testing, formal software QA, and revisions to operating procedures are in progress to achieve completion of the GIC system upgrade project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters: Preprint

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Controller-Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System With Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). This CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

SuperNeurons: Dynamic GPU Memory Management for Training Deep Neural Networks

Going deeper and wider in neural architectures improves their accuracy, while the limited GPU DRAM places an undesired restriction on the network design domain. Deep Learning (DL) practitioners either need to change to less de- sired network architectures, or nontrivially dissect a network across multiGPUs. These distract DL practitioners from concentrating on their original machine learning tasks. We present SuperNeurons: a dynamic GPU memory scheduling runtime to enable the network training far beyond the GPU DRAM capacity. SuperNeurons features 3 memory optimizations, Liveness Analysis, Unified Tensor Pool, and Cost-Aware Recomputation; together they effectively reduce the network-wide peak memory usage down to the maximal memory usage among layers. We also address the performance issues in these memory-saving techniques. Given the limited GPU DRAM, SuperNeurons not only provisions the necessary memory for the training, but also dynamically allocates the memory for convolution workspaces to achieve the high performance. Evaluations against Caffe, Torch, MXNet and TensorFlow have demonstrated that SuperNeurons trains at least 3.2432 deeper network than current ones with the leading performance. Particularly, SuperNeurons can train ResNet2500 that has 104 basic network layers on a 12GB K40c.

Wang, Linnan↗

Critical heat flux impact due to cladding surface condition

This paper demonstrates how the cladding surface condition can impact fuel rod heat transfer and critical heat flux (CHF) performance at Pressurized Water Reactor (PWR) type conditions. The cladding surface that is investigated here is a surface with a crud deposit similar to ones observed in a PWR reactor. Tests are performed in the Westinghouse WALT (Westinghouse Advanced Loop Tester) loop test facility where a single ZIRLO clad electrically heated rod with approximately one-foot length is tested at PWR thermal hydraulic conditions and chemistry. Tests are performed for a normal clean rod surface, an oxide surface and with CRUD deposits to investigate the impact on fuel rod heat transfer and CHF performance. The CRUD deposit is characterized for thickness, chimney size and porosity. Test results are presented for the different cladding surface conditions along with comparisons to evaluations performed in the literature for different surfaces at pool boiling conditions. The results indicate that the WALT loop test facility can produce CHF test results which are repeatable for the same heater rod and for different rods with the same surface condition. CHF test results for a ZIRLO cladding surface with a CRUD deposit near 20 microns typical of PWR deposits show similar CHF performance to clean rod surfaces. A noticeable increase in CHF performance was observed for a ZIRLO cladding surface with a thermal oxide layer based on one CHF measurement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Examining the Role of IMU Health Characterization and Monitoring in UAS Safety

Inertial measurement units (IMUs) can be vital for vehicle attitude and position estimation in unmanned aerial vehicles (UAVs). Degradation in these units could result in incorrect position estimates that are utilized in vehicle control, trajectory prediction, and other critical systems; however, the modes and effects of degradation in these IMUs are not well understood. In order to quantify the risk posed by degradation in these sensors, a study was conducted on the types of IMUs prevalent in the commercial market, their known failure modes, and the applicability to health monitoring methods for risk reduction and increased safety in an increasingly autonomous airspace. First, use cases and failure modes of the various types and reliability of commercially available IMUs were reviewed, and knowledge gaps and issues in the field were identified. Noting that inexpensive and lightweight MEMS (Microelectromechanical Systems) IMUs are some of the most commonly used but least reliable sensors in sUAS (small Unmanned Aerial Systems), five inexpensive MEMS IMUs were chosen for a performance evaluation study, selected from the Pixhawk autopilot systems, hobby sUAS, and prior NASA experimental studies. For each of these IMUs, a 10-minute bias test and a 12-hour drift test were performed for the accelerometers in a benchtop setting, using a BeagleBone Black for data collection. Using these results, the sensors’ performance is compared to their reported specifications, and the utility of implementing diagnostic methods for MEMS IMUs for research and commercial applications is evaluated. The paper concludes with a planned study for the evaluation of vibration-induced degradation for the selected sensors.

IMUs↗

Modeling of Irradiation Hardening of Polycrystalline Materials

High energy particle irradiation of structural polycrystalline materials usually produces irradiation hardening and embrittlement. The development of predict capability for the influence of irradiation on mechanical behavior is very important in materials design for next generation reactors. In this work a multiscale approach was implemented to predict irradiation hardening of body centered cubic (bcc) alpha-iron. The effect of defect density, texture and grain boundary was investigated. In the microscale, dislocation dynamics models were used to predict the critical resolved shear stress from the evolution of local dislocation and defects. In the macroscale, a viscoplastic self-consistent model was applied to predict the irradiation hardening in samples with changes in texture and grain boundary. This multiscale modeling can guide performance evaluation of structural materials used in next generation nuclear reactors.

36 MATERIALS SCIENCE↗

Fine pointing of the Solar Optical Telescope in the Space Shuttle environment

Instruments requiring fine (i.e., sub-arcsecond) pointing, such as the Solar Optical Telescope (SOT), must be equipped with two-stage pointing devices, coarse and fine. Coarse pointing will be performed by a gimbal system, such as the Instrument Pointing System, while the image motion compensation (IMC) will provide fine pointing. This paper describes work performed on the SOT concept design that illustrates IMC as applied to SOT. The SOT control system was modeled in the frequency domain to evaluate performance, stability, and bandwidth requirements. The two requirements of the pointing control, i.e., the 2 arcsecond reproducibility and 0.03 arcsecond rms pointing jitter, can be satisfied by use of IMC at about 20 Hz bandwidth. The need for this high bandwidth is related to Shuttle-induced disturbances that arise primarily from man push-offs and vernier thruster firings. A block diagram of SOT model/stability analysis, schematic illustrations of the SOT pointing system, and a structural model summary are included.

Gowrinathan, S.↗

EVALUATION OF LVDTS FOR USE IN ATR IRRADIATION EXPERIMENTS

New materials are being considered for fuel, cladding, and structures in next generation and existing nuclear reactors. Such materials can experience significant dimensional changes during high temperature irradiation. Currently, these changes are determined by repeatedly irradiating a specimen for a defined period of time in the Advanced Test Reactor (ATR) and then removing it from the reactor for evaluation. The time and labor to remove, examine, and return irradiated samples for each measurement makes this approach very expensive. In addition, such techniques provide limited data and may disturb the phenomena of interest. To address these issues, the Idaho National Laboratory (INL) recently initiated efforts to evaluate candidate linear variable differential transducers (LVDTs) for use during high temperature irradiation experiments in typical ATR test locations. Two nuclear grade LVDTs are under consideration – a smaller diameter design qualified for temperatures up to 350 °C and a larger design with capabilities to 500 °C. Calibration and long duration performance evaluations are underway for temperatures up to 600 ºC. This paper presents results from these evaluations, which will ultimately lead to recommendations for an improved design for use in the ATR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-512: Intrinsic Characteristics of the Nine Detectors and Evaluation of Their Performance in Non-Equilibrium Radiation Dosimetry

Purpose The aim for the study was to compare intrinsic characteristics of the nine detectors and evaluate their performance in non-equilibrium radiation dosimetry. Methods The intrinsic characteristics of the nine detectors that were evaluated are based on the composition and size of the active volume, operating voltage, initial recombination of the collected charge, temperature, the effective cross section of the detectors. The shortterm stability and collection efficiency has been investigated. The minimum radiation detection sensitivity and detectors leakage current has been measured. The sensitivity to changes in energy spectrum as well as change in incident beam angles were measured an analyzed. Results The short-term stability of the measurements within every detector showed consistency in the measured values with the highest value of the standard deviation of the mean not exceeding 0.5%. Air ion chamber detectors showed minimum sensitivity to change in incident beam angles while diode detectors underestimated measurements up to 16%. Comparing the slope of the tangents for detector’s sensitivity curve, diode detectors illustrate more sensitivity to change in photon spectrum than ion chamber detectors. The change in radiation detection sensitivity with increase in dose delivered has been observed for semiconductor detectors with maximum deviation 0.01% for doses between 1 Gy and 10 Gy. Leakage current has been mainly influenced by bias voltage (ion chamber detectors) and room light intensity (diode detectors). With dose per pulse varying from 1.47E−4 to 5.1E−4 Gy/pulse the maximum change in collection efficiency was 1.4% for the air ion chambers up to 8% for liquid filled ion chamber. Conclusion Broad range of measurements performed showed all the detectors susceptible to some limitations and while they are suitable for use in broad scope of applications, careful selection has to be made for particular range of measurements.

60 APPLIED LIFE SCIENCES↗

Highly-Active and Contaminant-Tolerant Cathodes for Durable Solid Oxide Fuel Cells (Final Report)

The objective of this project is to investigate the fundamental degradation methods occurring in solid oxide fuel cell (SOFC) cathodes when exposed to chromium and carbon dioxide contamination and to rationally design alkaline earth-based catalysts to increase stability and tolerance to contaminate poisoning. With a mechanistic and fundamental understanding of the degradation methods, advanced catalytic surface modifications can be applied to reduce degradation. The specific technical objectives are: (1) To identify/develop new catalysts (alkaline-earth based-) that are compatible chemically with the state-of-the-art cathode materials at high temperatures required for fabrication and with contaminates commonly encountered under operating conditions; (2) To improve the infiltration process for optimal control of the thickness, composition, and uniformity of the catalyst coatings; (3) To evaluate the electro-catalytic activity toward ORR of the chemically-stable materials when exposed to different types of contaminants using electrical conductivity relaxation measurements on bar samples and performance evaluation of catalyst-infiltrated cathodes; (4) To unravel the contamination-tolerant mechanisms of the new catalyst coatings under realistic environmental conditions (with different types of contaminants) using powerful in situ and in operando characterization techniques performed on model cells with thin-film/pattern electrodes, as guided by modeling and simulation; (5) To establish scientific basis for rational design of new catalysts of high tolerance to contaminants; (6) To validate the long term stability of modified LSCF cathodes in commercially available cells/stacks under ROC. Alkaline earth-based catalysts have been systematically explored and tested under various contamination conditions. BaCoO 3-δ (BCO) was shown to produce the best catalytic activity enhancement as well as stability in a variety of contaminating conditions, including CO 2 and chromium. The microstructural evolution was investigated with SEM, EDS, and Raman spectroscopy, showing the BCO catalyst prevents the formation of insulating SrCrO 4 by forming electrically conductive BaCrO 4 . Electrochemical relaxation measurements determined the BCO catalyst coatings increased the surface diffusion coefficient but did not significantly affect the diffusion coefficient and determined an optimum surface modification layer of 100 nm. A novel Ba 0.9 Co 0.7 Fe 0.2 Nb 0.1 O x (BCFN) catalyst was also shown to have excellent stability in chromium containing atmospheres. A novel surface sol-gel (SSG) surface modification, which offers superior thickness and compositional control, was applied to SOFCs to produce BaO catalyst coatings. SSG BaO coatings were shown to produce conformal coatings on the electrode surface, greatly increasing stability in chromium containing atmospheres. An atomic level mechanistic approach was applied to investigate the stability of PrBa 0.8 Ca 0.2 Co2O 5+δ (PBCC) with respect to a variety of common contaminants, demonstrating thermodynamically its superior stability in CO2 containing atmospheres. Finally, the best catalyst coatings demonstrated in this project, BCO and PBCC, were applied to full cells which demonstrated superior stability for over 300 hours in CO 2 and Cr atmospheres.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly-Active and Contaminant-Tolerant Cathodes for Durable Solid Oxide Fuel Cells

The objective of this project is to investigate the fundamental degradation methods occurring in solid oxide fuel cell (SOFC) cathodes when exposed to chromium and carbon dioxide contamination and to rationally design alkaline earth-based catalysts to increase stability and tolerance to contaminate poisoning. With a mechanistic and fundamental understanding of the degradation methods, advanced catalytic surface modifications can be applied to reduce degradation. The specific technical objectives are: (1) To identify/develop new catalysts (alkaline-earth based-) that are compatible chemically with the state-of-the-art cathode materials at high temperatures required for fabrication and with contaminates commonly encountered under operating conditions; (2) To improve the infiltration process for optimal control of the thickness, composition, and uniformity of the catalyst coatings; (3) To evaluate the electro-catalytic activity toward ORR of the chemically-stable materials when exposed to different types of contaminants using electrical conductivity relaxation measurements on bar samples and performance evaluation of catalyst-infiltrated cathodes; (4) To unravel the contamination-tolerant mechanisms of the new catalyst coatings under realistic environmental conditions (with different types of contaminants) using powerful in situ and in operando characterization techniques performed on model cells with thin-film/pattern electrodes, as guided by modeling and simulation; (5) To establish scientific basis for rational design of new catalysts of high tolerance to contaminants; (6) To validate the long term stability of modified LSCF cathodes in commercially available cells/stacks under ROC. Alkaline earth-based catalysts have been systematically explored and tested under various contamination conditions. BaCoO 3-δ (BCO) was shown to produce the best catalytic activity enhancement as well as stability in a variety of contaminating conditions, including CO 2 and chromium. The microstructural evolution was investigated with SEM, EDS, and Raman spectroscopy, showing the BCO catalyst prevents the formation of insulating SrCrO 4 by forming electrically conductive BaCrO 4 . Electrochemical relaxation measurements determined the BCO catalyst coatings increased the surface diffusion coefficient but did not significantly affect the diffusion coefficient and determined an optimum surface modification layer of 100 nm. A novel Ba 0.9 Co 0.7 Fe 0.2 Nb 0.1 O x (BCFN) catalyst was also shown to have excellent stability in chromium containing atmospheres. A novel surface sol-gel (SSG) surface modification, which offers superior thickness and compositional control, was applied to SOFCs to produce BaO catalyst coatings. SSG BaO coatings were shown to produce conformal coatings on the electrode surface, greatly4 increasing stability in chromium containing atmospheres. An atomic level mechanistic approach was applied to investigate the stability of PrBa 0.8 Ca 0.2 Co 2 O 5+δ (PBCC) with respect to a variety of common contaminants, demonstrating thermodynamically its superior stability in CO 2 containing atmospheres. Finally, the best catalyst coatings demonstrated in this project, BCO and PBCC, were applied to full cells which demonstrated superior stability for over 300 hours in CO 2 and Cr atmospheres.

30 DIRECT ENERGY CONVERSION↗

Highly-Active and Contaminant-Tolerant Cathodes for Durable Solid Oxide Fuel Cells

The objective of this project is to investigate the fundamental degradation methods occurring in solid oxide fuel cell (SOFC) cathodes when exposed to chromium and carbon dioxide contamination and to rationally design alkaline earth-based catalysts to increase stability and tolerance to contaminate poisoning. With a mechanistic and fundamental understanding of the degradation methods, advanced catalytic surface modifications can be applied to reduce degradation. The specific technical objectives are: (1) To identify/develop new catalysts (alkaline-earth based-) that are compatible chemically with the state-of-the-art cathode materials at high temperatures required for fabrication and with contaminates commonly encountered under operating conditions; (2) To improve the infiltration process for optimal control of the thickness, composition, and uniformity of the catalyst coatings; (3) To evaluate the electro-catalytic activity toward ORR of the chemically-stable materials when exposed to different types of contaminants using electrical conductivity relaxation measurements on bar samples and performance evaluation of catalyst-infiltrated cathodes; (4) To unravel the contamination-tolerant mechanisms of the new catalyst coatings under realistic environmental conditions (with different types of contaminants) using powerful in situ and in operando characterization techniques performed on model cells with thin-film/pattern electrodes, as guided by modeling and simulation; (5) To establish scientific basis for rational design of new catalysts of high tolerance to contaminants; (6) To validate the long term stability of modified LSCF cathodes in commercially available cells/stacks under ROC. Alkaline earth-based catalysts have been systematically explored and tested under various contamination conditions. BaCoO 3-δ (BCO) was shown to produce the best catalytic activity enhancement as well as stability in a variety of contaminating conditions, including CO 2 and chromium. The microstructural evolution was investigated with SEM, EDS, and Raman spectroscopy, showing the BCO catalyst prevents the formation of insulating SrCrO 4 by forming electrically conductive BaCrO 4 . Electrochemical relaxation measurements determined the BCO catalyst coatings increased the surface diffusion coefficient but did not significantly affect the diffusion coefficient and determined an optimum surface modification layer of 100 nm. A novel Ba 0.9 Co 0.7 Fe 0.2 Nb 0.1 O x (BCFN) catalyst was also shown to have excellent stability in chromium containing atmospheres. A novel surface sol-gel (SSG) surface modification, which offers superior thickness and compositional control, was applied to SOFCs to produce BaO catalyst coatings. SSG BaO coatings were shown to produce conformal coatings on the electrode surface, greatly 4 increasing stability in chromium containing atmospheres. An atomic level mechanistic approach was applied to investigate the stability of PrBa 0.8 Ca 0.2 Co 2 O 5+δ (PBCC) with respect to a variety of common contaminants, demonstrating thermodynamically its superior stability in CO 2 containing atmospheres. Finally, the best catalyst coatings demonstrated in this project, BCO and PBCC, were applied to full cells which demonstrated superior stability for over 300 hours in CO 2 and Cr atmospheres

01 COAL, LIGNITE, AND PEAT↗