Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Design and Performance of an InAs Quantum Dot Scintillator with Integrated Photodetector

A new scintillation material composed of InAs quantum dots (QDs) hosted within a GaAs matrix was developed, and its performance with different types of radiation is evaluated. A methodology for designing an integrated photodetector (PD) with a low defect density and that is optically matched to the QD’s emission spectrum is introduced, utilizing an engineered epitaxial InAlGaAs metamorphic buffer layer. The photoluminescence (PL) collection efficiency of the integrated PD is examined using two-dimensional scanning laser excitation. The detector response to 5.5 MeV α-particles and 122 keV photons is presented. Yields of 13 electrons/keV for α-particles and 30–60 electrons/keV for photons were observed. The energy resolution of 12% observed with α-particles was mainly limited by noise- and geometry-related optical losses. The radiation hardness of an InAs QDs hosted within GaAs and a wider band gap AlGaAs ternary alloy was studied under a 1 MeV proton implantation up to a 10 14 cm –2 dose. The integrated PL responses were compared to evaluate PL quenching due to non-radiative defects. The QDs embedded in the AlGaAs demonstrated improved radiation hardness compared to QDs in the GaAs matrix and in the InGaAs quantum wells.

36 MATERIALS SCIENCE↗

Low-Energy Backgrounds in Solid-State Phonon and Charge Detectors

Solid-state phonon and charge detectors probe the scattering of weakly interacting particles, such as dark matter and neutrinos, through their low recoil thresholds. Recent advancements have pushed sensitivity to eV-scale energy depositions, uncovering previously unseen low-energy excess backgrounds. While some arise from known processes such as thermal radiation, luminescence, and stress, others remain unexplained. This review examines these backgrounds, their possible origins, and parallels to low-energy effects in solids, an understanding of which is essential for interpreting particle interactions at and below the eV scale.

coherent neutrino–nucleus scattering↗

Search for inelastic boosted dark matter with the ICARUS detector at the Gran Sasso Underground National Laboratory

We present the result of a search for inelastic boosted dark matter using the data corresponding to an exposure of 0.13 kton · year , collected by the ICARUS T-600 detector during its 2012–2013 operational period at the INFN Gran Sasso Underground National Laboratory. The benchmark boosted dark matter model features a multiparticle dark sector with a U ( 1 ) ′ gauge boson, the dark photon. The kinetic mixing of the dark photon with the Standard Model photon allows for a portal between the dark sector and the visible sector. The inelastic boosted dark matter interaction occurs when a dark matter particle inelastically scatters with an electron in the ICARUS detector, producing an outgoing, heavier dark sector state which subsequently decays back down to the dark matter particle, emitting a dark photon. The dark photon subsequently couples to a Standard Model photon through kinetic mixing. The Standard Model photon then converts to an electron-positron pair in the detector. This interaction process provides a distinct experimental signature that consists of a recoil electron from the primary interaction and an associated electron-positron pair from the secondary vertex. After analyzing 4,134 triggered events, the search results in zero observed events. Exclusion limits are set in the dark photon mass and coupling ( m X , ε ) parameter space for several selected optimal boosted dark matter mass sets and cover previously unexplored parameter space. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effectiveness of denoising diffusion probabilistic models for fast and high-fidelity whole-event simulation in high-energy heavy-ion experiments

Artificial intelligence (AI) generative models, such as generative adversarial networks (GANs), variational autoencoders, and normalizing flows, have been widely used and studied as efficient alternatives for traditional scientific simulations. However, they have several drawbacks, including training instability and inability to cover the entire data distribution, especially for regions where data are rare. This is particularly challenging for whole-event, full-detector simulations in high-energy heavy-ion experiments, such as sPHENIX at the Relativistic Heavy Ion Collider and Large Hadron Collider experiments, where thousands of particles are produced per event and interact with the detector. This work investigates the effectiveness of denoising diffusion probabilistic models (DDPMs) as an AI-based generative surrogate model for the sPHENIX experiment that includes the heavy-ion event generation and response of the entire calorimeter stack. DDPM performance in sPHENIX simulation data is compared with a popular rival, GANs. Results show that both DDPMs and GANs can reproduce the data distribution where the examples are abundant (low-to-medium calorimeter energies). Nonetheless, DDPMs significantly outperform GANs, especially in high-energy regions where data are rare. Additionally, DDPMs exhibit superior stability compared to GANs. The results are consistent between both central and peripheral centrality heavy-ion collision events. Moreover, DDPMs offer a substantial speedup of approximately a factor of 100 compared to the traditional Geant4 simulation method.

42 ENGINEERING↗

The NEWS-G detector at SNOLAB

The New Experiments With Spheres-Gas (NEWS-G) collaboration intends to achieve sub-GeV/c 2 Weakly Interacting Massive Particles (WIMPs) detection using Spherical Proportional Counters (SPCs). SPCs are gaseous detectors relying on ionisation with a single ionization electron energy threshold. The latest generation of SPC for direct dark matter searches has been installed at SNOLAB in Canada in 2021. This article details the different processes involved in the fabrication of the NEWS-G experiment. Also outlined in this paper are the mitigation strategies, measurements of radioactivity of the different components, and estimations of induced background event rates that were used to quantify and address detector backgrounds.

47 OTHER INSTRUMENTATION↗

MAIA: A new detector concept for a 10 TeV muon collider

Muon colliders offer a compelling opportunity to explore the TeV scale and conduct precision tests of the Standard Model, all within a relatively compact geographical footprint. This paper introduces a new detector concept, MAIA (Muon Accelerator Instrumented Apparatus), optimized for $\sqrt{s}=10$ TeV $\mu\mu$ collisions. The detector features an all-silicon tracker immersed in a 5T solenoid field. High-granularity silicon-tungsten and iron-scintillator calorimeters surrounding the solenoid capture high-energy electronic and hadronic showers, respectively, and support particle-flow reconstruction. The outermost subsystem comprises an air-gap muon spectrometer, which enables standalone track reconstruction for high-momentum muons. The performance of the MAIA detector is evaluated in terms of differential particle reconstruction efficiencies and resolutions. Beam-induced background (BIB) simulations generated in FLUKA are overlaid with single particle gun samples to assess detector reconstruction capabilities under realistic experimental conditions. Even with BIB, reconstruction efficiencies exceed 95% for energetic tracks, photons, and neutrons in the central region of the detector. This paper outlines promising avenues of future work, including forward region optimization and opportunities for enhanced flavor/boosted object tagging, and addresses the technological assumptions needed to achieve the desired detector performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector and Physics Performance at a Muon Collider

A muon collider represents the ideal machine to reach very high center-of-mass energies and luminosities by colliding elementary particles. This is the result of the low level of beamstrahlung and synchrotron radiation compared to linear or circular electron-positron colliders. In contrast with other lepton machines, the design of a detector for a multi-TeV muon collider requires detailed knowledge of the interaction region due to the significant backgrounds created by muon beam decays in the collider ring. The physics reach can be properly evaluated only when the detector performance in such an environment is determined. In this work, the backgrounds generated by muon beams of 750 GeV are characterized and the performance of the tracking system and the calorimeter detector is illustrated. Solutions to minimize the effect of the beam-induced backgrounds are discussed and applied to obtain track and jet reconstruction performance. The μ + μ – → $Hν\bar{ν} → b\bar{b} ν\bar{ν}$ process is fully simulated and reconstructed to demonstrate that physics measurements are possible in this harsh environment. The measurement precision for the Higgs boson coupling to $b\bar{b}$ is evaluated for $\sqrt{s}$=1.5, 3, and 10 TeV and compared to other proposed machines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of the Influence of the RaD-X Balloon Payload on the Onboard Radiation Detectors

The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission, launched on 25 September 2015, provided dosimetric measurements above the Pfotzer maximum. The goal of taking these measurements is to improve aviation radiation models by providing a characterization of cosmic ray primaries, which are the source of radiation exposure at aviation altitudes. The RaD-X science payload consists of four instruments. The main science instrument is a tissue-equivalent proportional counter (TEPC). The other instruments consisted of three solid state silicon dosimeters: Liulin, Teledyne total ionizing dose (TID) and RaySure detectors. The instruments were housed in an aluminum structure protected by a foam cover. The structure partially shielded the detectors from cosmic rays but also created secondary particles, modifying the ambient radiation environment observed by the instruments. Therefore, it is necessary to account for the influence of the payload structure on the measured doses. In this paper, we present the results of modeling the effect of the balloon payload on the radiation detector measurements using a Geant-4 (GEometry ANd Tracking) application. Payload structure correction factors derived for the TEPC, Liulin, and TID instruments are provided as a function of altitude. Overall, the payload corrections are no more than a 7% effect on the radiation environment measurements.

Gronoff, Guilluame↗

A Generic High Bandwidth Data Acquisition Card for Physics Experiments

In high energy physics and nuclear physics experiments particularly the ones based on particle accelerator, the data rate from the detector is usually in the order of Terabytes per second. This high throughput data from detector front-end electronics need to be transmitted to the back-end computing farm for high level event selection and building. A Data Acquisition (DAQ) system with features of high-density, scalable, easily upgradeable is crucial to simplify the readout architecture of whole experiment. This paper will introduce the design of a generic high bandwidth PCIe card which can be used as the important input output card in a scalable DAQ system. It can factorize front-end electronics from data handling, and reduce amount of custom hardware in favor of scalable detectorindependent commercial hardware and software. Besides the 48 channels of bidirectional high speed fiber optical links with frontends, it also supports to synchronize with the experiment timing system, and to fanout the clock and trigger information with a fixed latency to the front-end electronics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for decays of the Higgs boson into pair-produced pseudoscalar particles decaying into τ+τ−τ+τ− using pp collisions at s=13 TeV with the ATLAS detector

A search for a pair of low-mass pseudoscalars a that promptly decay into τ-leptons is presented using 140 fb −1 of proton–proton collision data at 13 TeV centre-of-mass energy recorded with the ATLAS detector at the Large Hadron Collider. The result is used to place constraints on exotic decays of the Higgs boson into four τ-leptons, H→aa→τ+τ−τ+τ−. This search focuses on events with either one or two τ-leptons decaying into hadrons and neutrinos, and the remaining three or two τ-leptons decaying into either electron or muon and neutrinos. No significant excess is observed above the expected Standard Model background and upper limits at the 95% confidence level on B(H→aa→τ+τ−τ+τ−) are set ranging from 0.06 to 0.23, depending on the mass ma ranging from 15 to 60 GeV.

Source record↗

Astrophysics and Technical Study of a Solar Neutrino Spacecraft: NIAC (NASA Innovative Advanced Concepts) Grant - NASA 2018-Phase-1

We report on our study of the design of a neutrino detector, shielding and veto array needed to operate a neutrino detector in space close to the Sun. This study also took into account the expected rates of Galactic gamma and cosmic rays in addition to the particles from the Sun.These preliminary studies show that we can devise a detector such that a small signal of neutrino interactions can be extracted from a large random number of events from the background sources using a double timing method from the conversion electron produced in the neutrino interaction and a secondary delayed signal from the nuclear excited state produced from the initial neutrino interaction; in our case the conversion of Ga 69 or 71 into Ge 69 or 71, but this method could apply to other nuclei with large neutrino cross sections such as Ir 115. Although these types of events need to be above 0.405 megaelectronvolt (MeV) neutrino energy and are only 66 percent of all conversion neutrino interactions on Gallium, this is a small price to pay for an increase of 10,000 by going close to the Sun to enhance the neutrino rate over the background combatorical fake-signal events. The conclusion of this Phase-1 study is very positive in that we can get the backgrounds less than 20 percent fake signals, and in addition to this we have devised another shielding method that makes the Galactic gamma-ray rate a hundred fold less which will make further improvements over these initial estimates. Although these studies are very encouraging it suggests that the next step is a NIAC Phase-II to actually build a test device,measuring basic principles such as light attention within the scintillator with high dopants and to take data in the lab with a cosmic-ray test stand and triggered X-ray source for comparison with simulated expected performance of the detector. This would be the perfect lead into a future proposal beyond a NIAC (NASA Innovative Advanced Concepts) Phase-II for a test flight of a small one-pint detector in orbit of the detector concept beyond Earth outside of the radiation belts.

Astrophysics↗

The structure of low-lying 1 - states in 90,94 Zr from (α,α'γ) and (p,p'γ) reactions

The low-lying dipole strength in the 90,94 Zr nuclei was investigated via (ρ,ρ'γ) at 80 MeV and (α, α', γ) at 130 MeV. The experiments, made at RCNP, used the magnetic spectrometer Grand Raiden for the scattered particles and the array CAGRA with HPGe detectors for the γ-decay. For 94 Zr these are the first data for both reactions and for 90 Zr these are the first data with (ρ,ρ'γ) and the first ones at high resolution for (α, α', γ). The comparison of the present results for the two nuclei with existing (γ, γ') data shows that both nuclear probes produce an excitation pattern different than that of the electromagnetic probes. DWBA calculations were made using form factors deduced from transition densities, based on RPA calculations, characterized by a strong neutron component at the nuclear surface. A combined analysis of the two reactions was performed for the first time to investigate the isoscalar character of the 1 - states in 90,94 Zr. The (ρ,ρ'γ) cross section was calculated using values for the isoscalar electric dipole energy-weighted sum rule (E1 ISEWSR) obtained from the (α, α', γ) data. The isoscalar strength for 90 Zr was found to exhaust 20 ± 2.5% of the EWSR in the energy range up to 12 MeV. In case of 94 Zr, a strength of 9 ± 1.1% of the EWSR was found in the range up to 8.5 MeV. Although an overall general description was obtained in the studied energy intervals, not all proton cross sections were well reproduced using the isoscalar strength from (α, α', γ). This might suggest mixing of isoscalar and isovector components and that this mixing and the degree of collectivity are not the same for all the 1 - states below the particle binding energy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of proton quenching in a plastic scintillator detector

The non-linear energy response of the plastic scintillator EJ-260 is measured with the MicroCHANDLER detector, using neutron beams of energy 5 to 27 MeV at the Triangle Universities Nuclear Laboratory. The first and second order Birks' constants are extracted from the data, and found to be $k_B = (8.70 \pm 0.93)\times 10^{-3}\ {\rm g/cm^2/MeV}$ and $k_C = (1.42 \pm 1.00) \times 10^{-5}\ {\rm (g/cm^2/MeV)^2}$. This result covers a unique energy range that is of direct relevance for fast neutron backgrounds in reactor inverse beta decay detectors. Furthermore, these measurements will improve the energy non-linearity modeling of plastic scintillator detectors. In particular, the updated energy response model will lead to an improvement of fast neutron modeling for detectors based on the CHANDLER reactor neutrino detector technology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Feasibility study to use neutron capture for an ultralow energy nuclear-recoil calibration in liquid xenon

The feasibility of an ultra-low energy nuclear-recoil measurement in liquid xenon using neutron capture is investigated for a small (sub-kilogram) liquid xenon detector that is optimized for a high scintillation gain, and a pulsed neutron source. Further, the measurement uses the recoil energies imparted to xenon nuclei during the de-excitation process following neutron capture, where promptly emitted γ cascades can provide the nuclei with up to 0.3 keV nr of recoil energy due to conservation of momentum. A successful calibration of scintillation photon and ionization electron yields below this energy will contribute to a greater sensitivity for liquid xenon experiments in searches for light WIMPs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measured and projected beam backgrounds in the Belle II experiment at the SuperKEKB collider

The Belle II experiment at the SuperKEKB electron–positron collider aims to collect an unprecedented data set of 50 ab -1 to study CP -violation in the B -meson system and to search for Physics beyond the Standard Model. SuperKEKB is already the world’s highest-luminosity collider. In order to collect the planned data set within approximately one decade, the target is to reach a peak luminosity of 6 x 10 35 cm −2 s −1 by further increasing the beam currents and reducing the beam size at the interaction point by squeezing the betatron function down to β $^*_y$ = 0.3 mm. To ensure detector longevity and maintain good reconstruction performance, beam backgrounds must remain well controlled. We report on current background rates in Belle II and compare these against simulation. We find that a number of recent refinements have significantly improved the background simulation accuracy. Finally, we estimate the safety margins going forward. We predict that backgrounds should remain high but acceptable until a luminosity of at least 2.8 x 10 35 cm −2 s −1 is reached for β $^*_y$ = 0.6 mm. At this point, the most vulnerable Belle II detectors, the Time-of-Propagation (TOP) particle identification system and the Central Drift Chamber (CDC), have predicted background hit rates from single-beam and luminosity backgrounds that add up to approximately half of the maximum acceptable rates.

Detector background↗

Secondary scintillation properties of multi-layer THGEMs operated in low-pressure CF 4 and Ar/5%Xe

We present a measurement of the secondary scintillation yield produced by two-layer Thick Gas Electron Multipliers (M-THGEMs) in pure Tetrafluoromethane (CF 4 ) gas and in Ar mixed with 5% Xe in low-pressures down to 20 Torr. The detector was irradiated with 5.49 MeV alpha particles from a low-rate 241-Am source. The secondary scintillation light generated during the gas avalanche process was read out by a Hamamatsu photomultiplier tube (model R8520-406), sensitive to a broad wavelength range (160–650 nm). The avalanche charge was collected on the bottom electrode of M-THGEM and correlated to the scintillation light on an event-by-event basis. We observed that, for both gas types, the value of the photon to electron production ratio (0.4 ph/el in CF 4 and 0.1 ph/el in Ar/5%Xe) increases with the thickness of the M-THGEM electrodes and varies significantly with the pressure, being higher at lower values. The decrease in electroluminescence yield at higher pressures is much more pronounced in the Ar/Xe mixture. In addition, because of a larger gas avalanche volume, the electroluminescence light yield is larger in thicker M-THGEM structures. Presented results are particularly useful for designing the next generation of Optical-readout Time Projection Chambers (O-TPCs) operated at low-pressure CF 4 ; applications include experimental nuclear physics with rare isotope beams, dark matter detection with directional sensitivity and observation of the Migdal effect in a low-pressure Optical TPC.

47 OTHER INSTRUMENTATION↗

Measurement of the bulk radioactive contamination of detector-grade silicon with DAMIC at SNOLAB

We present measurements of bulk radiocontaminants in the high-resistivity silicon CCDs from the DAMIC experiment at SNOLAB. We utilize the exquisite spatial resolution of CCDs to discriminate between α and β decays, and to search with high efficiency for the spatially-correlated decays of various radioisotope sequences. Using spatially-correlated β decays, we measure a bulk radioactive contamination of 32 Si in the CCDs of 140 ± 30 μBq/kg, and place an upper limit on bulk 210 Pb of < 160 μBq/kg. Using similar analyses of spatially-correlated α and β decays, we set upper limits of < 11 μBq/kg (0.9 ppt) on 238 U and < 7.3 μBq/kg (1.8 ppt) on 232 Th in the bulk silicon. The ability of DAMIC CCDs to identify and reject spatially-coincident backgrounds, particularly from 32 Si, has significant implications for the next generation of silicon-based dark matter experiments, where β's from 32 Si decay will likely be a dominant background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗