Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PIXELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Aspen ploidy level and cover maps from NEON Airborne Observation Platform, 2018, Crested Butte, Colorado

Maps of aspen ploidy (diploid or triploid) developed using National Ecological Observatory Network (NEON) Airborne Observation Platform visible to shortwave infrared imaging spectroscopy data that were acquired over the Upper East River, Colorado in 2018. Maps of aspen distribution, as well as other land cover types that were used to screen for aspen dominated pixels are also provided. Each image file is provided as a GeoTiff with internal tiling and LZW compression. For use of ploidy maps, it is necessary to mask out non-aspen and shaded pixels. Shaded pixels are provided in an associated data package. For full details, please see associated publication and methods description. This dataset is associated with the publication in Ecological Applications.

54 ENVIRONMENTAL SCIENCES↗

Deployment of ADTimePix3 areaDetector Driver at Neutron and X-ray User Facilities

TimePix3 is a 65k hybrid pixel readout chip with simultaneous Time-of-Arrival (ToA) and Time-over-Threshold (ToT) recording in each pixel*. The chip operates without a trigger signal with a sparse readout where only pixels containing events are read out. The flexible architecture allows 40 MHits/s/cm² readout throughput, using simultaneous readout and acquisition by sharing readout logic with transport logic of superpixel matrix formed using 2x4 structure. The chip ToA records 1.5625 ns time resolution. The X-ray and charged particle events are counted directly. However, indirect neutron counts use 6Li fission in a scintillator matrix, such as ZnS(Ag). The fission space-charge region is limited to 5-9 um. A photon from scintillator material excites a photocathode electron, which is further multiplied in dual-stack MCP. The neutron count event is a cluster of electron events at the chip. We report on the EPICS areaDetector** ADTimePix3 driver that controls Serval*** using json commands. The driver directs data to storage and to a real-time processing pipeline and configures the chip. The time-stamped data are stored in raw .tpx3 file format and passed through a socket where the clustering software identifies individual neutron events. The conventional 2D images are available as images for each exposure frame, and a preview is useful for sample alignment. The areaDetector driver allows integration of time-enhanced capabilities of this detector into SNS beamlines controls and unprecedented time resolution.

Gofron, Kaz↗

Development of processing algorithms to enable high-rate microcalorimeter array operation

The millisecond-scale decay constants of microcalorimeter gamma-ray pulses present challenges for operation at high count rates needed to compete with semiconductor HPGe detectors. If using conventional optimal filtering methods, pulse records with pileup events are simply discarded, leading to a large fraction of data unused when count rates are large. For single pixel rates exceeding 1-2 Hz, improved pulse processing algorithms are needed to better deal with pileup and increase the filter throughput. A 256-pixel array operating at 10 Hz per pixel would provide a total counting rate of 2.5 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D, Flash, Induced Current Readout for Silicon Sensors

A new method for silicon microstrip and pixel detector readout using (1) 65 nm-technology current amplifers which can, for the first time with silicon microstrop and pixel detectors, have response times far shorter than the charge collection time (2) 3D trench electrodes large enough to subtend a reasonable solid angle at most track locations and so have adequate sensitivity over a substantial volume of pixel, (3) induced signals in addition to, or in place of, collected charge

47 OTHER INSTRUMENTATION↗

Focal Plane Array Low Background Testing (Focal Plane Array Characterization under a Low Background)

Most infra-red (IR) imagers for tactical applications use a direct injection (DI) input amplifier design. Fewer transistors in the unit cell allow the read-out electronic circuit (ROIC) to be minimized. This allows either more room for charge integration capacitors or finer pixel pitches. These ROICs work well at high background irradiance levels. However, at low background irradiance levels photocurrent inject efficiency for a DI unit cell amplifier is reduced. Some models have shown that this efficiency can drastically affect performance under low background conditions. The main benefit for Sandia National Laboratories (SNL) and L-3 Communications Cincinnati Electronics (L-3) was a better understanding of these types of sensors under low background conditions. It also provided the opportunity for an independent analysis of these sensors. The purpose of this project was to measure DI for low light levels under different operating temperatures of the L-3 CE103 a 1280 x 1024 indium antimonide 15 micron pitch detector. Results showed DI efficiency approaches 75% under extremely low light levels. Additionally, measured data didn't conform well to traditional circuit based models indicated that other effects are contributing to DI efficiency. A "spot scanning" PSF measurement was also conducted to measure pixel-to-pixel crosstalk for this array. Spot scanning data showed near ideal performance.

47 OTHER INSTRUMENTATION↗

Elementary Particle Physics

The UT Dallas High Energy Physics group collaborates on the ATLAS experiment which observes the world’s high energy proton-proton collisions. The UTD group utilized ATLAS 8 TeV Run 1 data to search for evidence of a “dark photon”, a gauge boson outside the “Standard Model of Particle Physics” that theorist hypothesize could mediate a force felt only by the dark matter particles that dominate out universe. The observable signature is a pair of prompt lepton jets. The results of this search were published in 2013. More recently, we have improved the sensitivity of the analysis using machine learning techniques, and we are extending the search to higher and lower mass dark photons using the ATLAS 13 TeV data set. Detection of a new fifth force would represent an important advance beyond the 4 known forces that influence baryonic matter. The LHC Long Shutdown 1 from 2013-2014 was a period of intense work on refurbishment and upgrades for the ATLAS Pixel community and the UTD group. The service quarter panels of the original Pixel detector were replaced, and the Insertable B Layer (IBL) detector was integrated. During IBL integration, UTD participated on the Stave Task Force that solved corrosion problems with IBL wire bonds. We developed a relative humidity sensor that was used during integration and transport to the beamline when detector was unpowered. The sensors were repurposed to monitor relative humidity inside the ID endplates until the built-in sensors were recommissioned. The UTD group worked on the connection of the Pixel and IBL at Point 1 and we were in charge of electric service testing. The IBL wire bond corrosion was the instigation for developing a new conformal coating method using an atomizing spray and Cellpack polyurethane. It is being considered for use in the ITk tracker upgrade. We have demonstrated its tolerance both of a 9 MGy ionizing dose and thermal expansion. Two UTD students are completing authorship qualification projects. One is helping understand variations in impact parameter resolution across different running periods. The second is developing a data-driven method to monitor the fraction of fake tracks in dense jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The ETROC Project: Precision Timing ASIC Development for LGAD-based CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD silicon devices to be read out by ETROCs for precision timing measurement with down to 30 ps timing resolution. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel cell being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. Approximately 15% of the sensors near the highest eta region will experience hadron fluence above 1e15 neq/cm² towards end of operation of HL-LHC, resulting in small signal amplitude with LGAD gain reduced to around 10. For this reason, the front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile.

97 MATHEMATICS AND COMPUTING↗

A New CIERRA Gridded Product Climatology for LIS/OTD

The GLM-CIERRA processing generates two products: A level-2 cluster feature dataset that merges flashes that should have been a single flash following the clustering algorithm flash definition (for GLM, this is due to the LCFA thresholds); A set of level-3 gridded products including Flash Extent Density, Convective Probability, etc. The CIERRA Level-3 products are generated on a 0.1 degree grid. This is suboptimal given the spatial variations in GLM pixel size AND the size of gridpoints in the output grid. As a stepping-stone towards developing improved GLM-CIERRA grids, I am testing pixel matching techniques on the LIS/OTD data. The goal is to maintain accuracy while vastly improving computational efficiency. The CIERRA reclustering codes are also being applied to LIS / OTD to merge flashes split by the “first fit” clustering technique. The end result will be standardized grids at the nominal resolution of each instrument (5 km for LIS, 10 km for OTD) that take into account the pixel geometry for each event that comprises a given reclustered flash.

54 ENVIRONMENTAL SCIENCES↗

Ultra low background time projection alpha particle detector ( Phase II Final Scientific/Technical Report)

When alpha particles are emitted into a gas they create an ionization track of gas ions and electrons. In our commercial UltraLo instrument we apply a voltage between a planar sample and an anode, integrate the anode signal as it collects the electrons, and distinguish between alphas emitted from the sample and elsewhere (anode, sidewalls) by the duration and shape of the resultant signal. The major contributors limiting the instrument’s lower detection limit are cosmic rays that pass through the detector close to the sample and Rn decays that produce charge tracks the originate in the gas and end on the sample. In this work we proposed to identify and reject these events by converting the anode into a multi-pixel array and operating in time projection mode. Cosmic rays would be eliminated by generating charge on many pixels, while charge collection asymmetry would distinguish between sample events (Bragg curve up) and Rn events (Bragg curve down). We therefore proposed to modify an UltraLo by pixilating its anode, developing low noise, low power multiplexed electronics to track each pixel’s signal individually, and develop analysis software to make the required discriminations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chamber Interior Viewing System (CIVS 2.0)

The NIF facility is used to conduct fusion and high-density scientific research. The experiments are conducted inside of a 10-meter diameter vacuum chamber called the “Target Chamber”. The target chamber is covered in ports to permit adding equipment to the exterior. Some of this equipment extends into the target chamber such as the target positioners and diagnostics. Other equipment sits on the surface and looks inward, such as the CIVS system. CIVS stands for Chamber Interior Viewing System. The CIVS system provides simple black and white digital images of the interior of the target chamber in real time. These images are used for positioner alignment, trouble shooting and observing for positioner collision. The views through these cameras need to be clear enough for the operators to safely conduct these tasks. One of the products of the experiments conducted in the target chamber are neutrons. These neutrons expand outward from the center of the target chamber with great energy. If the neutrons hit the sensor chip on a digital camera they will “kill” the sensor pixel where they contact, and the result will be a permanently bright white pixel on the image. Over time these “dead” pixels will build up and make the camera less and less usable providing a “staticky” image. The current solution of replacing the cameras when they become damaged is unsustainable due to both the cameras being out of production and the increased rate of camera failure based upon the increased number and energy of neutrons being generated. Current supplies of the correct camera type are dwindling with no source of replacement and the projected rate of replacement is unsustainable. Without a redesign, the function provided by the current CIVS system will be lost.

42 ENGINEERING↗

Characterization of ORNL PSD ASIC

The performance of the ORNL ASIC and its readout system was tested with pixelated organic scintillators. We use a pixelated trans-Stilbene scintillator array from Inrad Optics and a pixelated organic glass scintillator array developed at Sandia National Laboratories to characterize the energy and timing resolutions and the pulse-shape discrimination (PSD) figure-of-merit (FoM). The results are compared to previous work in which the same metrics were measured on waveforms digitized at 250 MHz with 14-bit resolution. We found that the PSD FoM at 340 keVee of the ASIC configuration compared to waveform data varied with the scintillator type. We measured a PSD FoM of 1.12 ± 0.14 with the ASIC configuration versus 1.39 ± 0.23 with waveform data using the trans-Stilbene array. We measured a PSD FoM of 0.52 ± 0.18 with the ASIC configuration versus 1.25 ± 0.19 with waveform data using the the organic glass scintillator array. The coincidence timing resolution was measured using two 6x6x6 mm 3 cubes of trans-Stilbene. It was measured to be 805 ± 9 ps with the ASIC configuration versus 300 ps on average with waveform data.

42 ENGINEERING↗

Dense Image Matching Uncertainty Estimation and Confidence Metrics

Dense stereo matching takes overlapping image pairs as input and outputs a disparity map which encodes pixel-by-pixel matches between the images. Recently, there has been an interest in ranking the quality, or even quantifying the accuracy, of disparity estimates. The proposed methods can be described as either uncertainty estimators or confidence metrics. Uncertainty estimators are a small minority of the research. However, they have the potential to be the most useful because they estimate disparity accuracy (in pixel units) that can be used to threshold matches or carried forward using error propagation. The majority of the research deals with confidence metrics which give an ordinal (or binary) ranking of a match’s quality relative to other matches. Confidence metrics do not have units and thus are useful primarily for thresholding matches from mismatches. The methods could also be described as handcrafted or deep-learning based. The majority of the research focused on outdoor driving scenes. Hence, our interest–application to a satellite semi-global matching pipeline–is a domain shift that may challenge deep-learning based methods. We conclude by recommending five handcrafted and two deep-learning based methods for evaluation in our pipeline.

97 MATHEMATICS AND COMPUTING↗

Digital Silicon Photomultiplier Chip Testing

Silicon Photomultipliers (SiPMs) are highly sensitive photodetectors. Traditional analog SiPMs require complex external readout electronics. Digital SiPMs (dSiPMs) include digital readout circuitry directly on-chip, offering superior timing resolution, reduced power consumption and compact size, pixel-level masking for active noise reduction. The primary objectives of this study are to, verify digital logic integrity of the shift registers used for controlling the pixel masking circuit, and determine the dark count rate of individual pixels as a function of bias voltage and clock frequency. I observe and explain behavior of the shift register and counting circuit.

Graham, Bennett [U. Chicago (main)]↗

DECAL MDN Resolution Calibration

The simulated pixelated calorimeter uses 0.1 mm × 0.1 mm silicon pixels (0.0001 cm²) silicon pixels as active layers — far finer than current concepts like HGCAL (~0.5 cm²) — improving energy resolution through much finer segmentation. While the standard resolution formalism fits three numbers to a handful of discrete test-beam energies, this work is a first try at a more data-efficient alternative: learning the full response shape continuously in energy with a mixture density network. This continuous, differentiable surrogate is a natural building block for fast simulation of extremely complex calorimeters.

Wang, Peter [U. Chicago (main)]↗

Thermal Microphotonic Focal Plane Array (TM-FPA).

The advent of high quality factor (Q) microphotonic-resonators has led to the demonstration of high-fidelity optical sensors of many physical phenomena (e.g. mechanical, chemical, and biological sensing) often with far better sensitivity than traditional techniques. Microphotonic-resonators also offer potential advantages as uncooled thermal detectors including significantly better noise performance, smaller pixel size, and faster response times than current thermal detectors. In particular, microphotonic thermal detectors do not suffer from Johnson noise in the sensor, offer far greater responsivity, and greater thermal isolation as they do not require metallic leads to the sensing element. Such advantages make the prospect of a microphotonic thermal imager highly attractive. Here, we introduce the microphotonic thermal detection technique, present the theoretical basis for the approach, discuss our progress on the development of this technology and consider future directions for thermal microphotonic imaging. Already we have demonstrated viability of device fabrication with the successful demonstration of a 20{micro}m pixel, and a scalable readout technique. Further, to date, we have achieved internal noise performance (NEP{sub Internal} < 1pW/{radical}Hz) in a 20{micro}m pixel thereby exceeding the noise performance of the best microbolometers while simultaneously demonstrating a thermal time constant ({tau} = 2ms) that is five times faster. In all, this results in an internal detectivity of D*{sub internal} = 2 x 10{sup 9}cm {center_dot} {radical}Hz/W, while roughly a factor of four better than the best uncooled commercial microbolometers, future demonstrations should enable another order of magnitude in sensitivity. While much work remains to achieve the level of maturity required for a deployable technology, already, microphotonic thermal detection has demonstrated considerable potential.

47 OTHER INSTRUMENTATION↗

Performance of the AstroPix Prototype Module for the Barrel Imaging Calorimeter at the ePIC Detector and in Space-Based Payloads

AstroPix is a high-voltage CMOS (HV-CMOS) monolithic active pixel sensor originally developed to enable precision gamma-ray imaging and spectroscopy in the medium-energy regime (~100 keV–100 MeV) based on the groundwork laid by ATLASpix and MuPix. It features a 500 μm pixel pitch, in-pixel amplification and digitization, and low power consumption (~3-4 mW/cm2), making it scalable for large-area, multilayer telescope detector planes. The detectors have a designed dynamic range of 25 keV to 700 keV. With these features, AstroPix meets the requirements of future space-based high-energy telescopes and the imaging layers of the Barrel Imaging Calorimeter (BIC) in the Electron-Proton/Ion Collider (ePIC) detector at the future Electron-Ion Collider (EIC). For the space-based payload, AstroPix is being integrated into sounding rocket and balloon payloads to demonstrate the technical readiness of the devices. For BIC, AstroPix-based imaging layers interleaved within the lead/scintillating-fiber (Pb/SciFi) sampling calorimeter provide granular shower imaging, enabling key performance features such as electron/pion or gamma/neutral pion separation. As part of the ongoing detector R&D efforts, we have been testing various AstroPix_v3 configurations: the single chip, a quad-chip assembly, a three-layer stack of quad chips, and a 9-chip module that represents the smallest prototype unit of the BIC imaging layer. This presentation will highlight recent performance test results from these AstroPix detector configurations.

Kim, Bobae (ORCID:0000000295396815)↗

SLOPE daily and 250 m gross primary productivity (GPP) for the CONUS, 2000-2019, Carbon Monitoring System (CMS)

The SatelLite Only Photosynthesis Estimation (SLOPE) GPP product is a daily, 250 m GPP dataset covering the Contiguous United States (CONUS) from 2000 to present with 1 day latency. Gross primary productivity (GPP) quantifies the amount of carbon dioxide (CO2) fixed by plants through photosynthesis. Although as a key quantity of terrestrial ecosystems, there is a lack of high-spatial-and-temporal-resolution, real-time, and observation-based GPP products. This product has been developed to address this critical gap, leveraging a number of MODIS land and atmosphere products. There are three distinct features of the SLOPE GPP production algorithm. (1) SLOPE couples machine learning models with MODIS atmosphere and land products to accurately estimate PAR. (2) SLOPE couples highly efficient and pragmatic gap-filling and filtering algorithms with surface reflectance acquired by both Terra and Aqua MODIS satellites to derive a soil-adjusted NIRv (SANIRv) dataset. (3) SLOPE couples a temporal pattern recognition approach with a long-term Crop Data Layer (CDL) product to predict dynamic C4 crop fraction. PAR, SANIRv and C4 fraction are used to drive a parsimonious model with only two slope parameters to estimate GPP along with a quantitative uncertainty on a per-pixel and daily basis. The slope GPP product has a R2 = 0.84 and a root-mean-square error (RMSE) of 1.65 gC m-2 d-1, evaluated against from 50 AmeriFlux eddy covariance sites (332 site-years). Archived data from 2000 to 2019 are publicly available at the NASA's Oak Ridge National Laboratory Distributed Active Archive Center (ORNL DAAC). Data from 2020 are available from the authors upon request. All data are projected in the standard MODIS Land Integerized Sinusoidal tile map projection. Each processing tile is in size of 4800 pixels by 4800 pixels, representing approximately 1200 km by 1200 km land region. In addition to the GPP product, SLOPE PAR, SANIRV, and C4 fraction, along with their uncertainties, are also released.

Jiang, Chongya↗

Diffraction-Based Optical Switching with MEMS

In this article, we are presenting an overview of MEMS-based (Micro-Electro-Mechanical System) optical switch technology starting from the reflective two-dimensional (2D) and three-dimensional (3D) MEMS implementations. To further increase the speed of the MEMS from these devices, the mirror size needs to be reduced. Small mirror size prevents efficient reflection but favors a diffraction-based approach. Two implementations have been demonstrated, one using the Texas Instruments DLP (Digital Light Processing), and the other an LCoS-based (Liquid Crystal on Silicon) SLM (Spatial Light Modulator). These switches demonstrated the benefit of diffraction, by independently achieving high speed, efficiency, and high number of ports. We also demonstrated for the first time that PSK (Phase Shift Keying) modulation format can be used with diffraction-based devices. To be truly effective in diffraction mode, the MEMS pixels should modulate the phase of the incident light. We are presenting our past and current efforts to manufacture a new type of MEMS where the pixels are moving in the vertical direction. The original structure is a 32 x 32 phase modulator array with high contrast grating pixels, and we are introducing a new sub-wavelength linear array capable of a 310 kHz modulation rate

36 MATERIALS SCIENCE↗