At least 1,567 records · Page 87

Scalable membrane-less microbial electrolysis cell with multiple compact electrode assemblies for high performance hydrogen production

Bioelectrochemical hydrogen production via microbial electrolysis cells (MECs) is a promising method for sustainable energy production and decarbonization of energy systems. However, the application of MECs is limited by the electrochemical performance, scalability, and the cost associated with expensive materials. Here, in this study, a scalable MEC (500 mL) with novel compact electrode assemblies and high electrode surface area to volume ratio (160 m 2 /m 3 ) was designed and constructed. The use of membranes, precious metal catalyst, and current collectors with high costs was avoided. A high current density at the steady state of 49.5 ± 5.3 A/m 2 was achieved using acetate as the substrate with phosphate buffer under the applied voltage of 1.01 V. The corresponding volumetric current density was 3948 ± 422 A/m 3 . The compact electrode assembly design limited methane production rate to 3.9 ± 0.2 L/L/D, while achieving a hydrogen production rate of 33.7 ± 1.7 L/L/D. With the suppression of microbial hydrogen consumption, the hydrogen production rate was 39.8 ± 1.9 L/L/D, higher by almost one order of magnitude than those of MECs with scaling up attempts. The compact electrode configuration reduced internal resistance to 88.5 ± 4.4 Ω cm 2 . The energy efficiency based on input electricity was 146 ± 7 % to 189 ± 9 % within the applied voltage range of 0.71 to 1.05 V. The results in this study demonstrated successful scaling up of high performance small MECs and offered a new possible approach of scaling up MECs by stacking high-performance subunits, with no trade-offs on electrochemical performance.

08 HYDROGEN↗

Unraveling the relationship between physicochemical properties of NiFeReOx catalysts and the correlated performance toward electrochemical oxygen evolution reaction

NiFeO x catalysts with single site Re dopants exhibit much higher active and stability toward electrochemical oxygen evolution reaction (OER) compared to traditional NiFeO x catalysts. Nevertheless, the relationship between physicochemical properties of NiFeReO x catalysts and the correlated performance toward OER is unclear, which hampers to enhance the OER performance further. Herein, we prepared a series of NiFeReO x catalysts with different physicochemical properties by treating them at different temperatures (up to 350 °C) and then evaluated their performance toward OER. Here, the results show that heat treatment can convert all metal oxidation states to higher values as well as specific surface areas, which are believed to favor real active site generation and OER activity enhancement. A decrease in activity is observed with the temperature increase at the low current range, and the smallest overpotential of 248 mV at 10 mA cm −2 is achieved with the pristine NiFeReO x catalyst. In contrast, the heat-treated samples possess smaller Tafel slopes and lower charge transfer resistance likely due to enhanced intrinsic activity (from higher oxidation states) and conductivity, which facilitate the reaction kinetics and surpass the pristine sample at a large current density. Additionally, the sample treated at 350 °C exhibits a higher activity at 1000 mA cm −2 (1.68 V vs. RHE compared to pristine sample of 1.92 V vs. RHE); however, it manifests a poorer stability compared to the pristine one due to the imbalance of reconstruction/transformations that occurred on the catalyst surface during OER operation. Our work unravels the relationship between physicochemical properties of NiFeReO x catalysts and the correlated OER performance and provides valuable insights for designing NiFeReO x catalysts with high activity and durability.

Catalyst reconstruction↗

Structural origin of size effect on piezoelectric performance of Pb(Zr,Ti)O 3

Grain size effect plays a vital role in piezoelectric performance from both scientific and technological view. However, the underlying structural mechanism related to grain size is still unclear. In the present study, the structural mechanism of grain size effect on piezoelectric performance has been revealed in the prototype Pb(Zr, Ti)O 3 system by using in-situ synchrotron X-ray diffraction. The miniaturization of grain size tends to favor the appearance of higher symmetric tetragonal phase, while a single monoclinic phase is determined in the coarse-grained ceramics. The direct structural evidence reveals that both tetragonal and monoclinic phases in the fine-grained ceramics are less sensitive to the electric field, corresponding to the inferior piezoelectric performance, while the single monoclinic phase in the coarse-grained ceramics is more active to be driven by the electric field, generating good piezoelectric behavior. Both domain switching ability and lattice strain are suppressed with decreasing grain size, which directly leads to the deterioration in piezoelectric performance. In conclusion, the current results will benefit the structural understanding of the size effect of piezoelectric and other related systems.

36 MATERIALS SCIENCE↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

This work presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 °C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 °C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 °C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COP th ) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COP el ) in most cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Impact of Off-Design CHP Performance on the Optimal Sizing and Dispatch on Hybrid Renewable-CHP Distributed Energy Resources

The maturation of distributed energy resources (DER) has prompted the exploration of their deployment in commercial building applications due to their potential to supply energy at lower costs and emissions rates compared to centralized generation. While several software tools exist for evaluating the techno-economic potential of integrated renewable energy and combined heat and power (CHP) systems for distributed generation applications, many suffer from poor accuracy in capturing off-design (part load and changes in ambient air temperature and pressure) performance characteristics of microturbines, combustion turbines, or internal combustion engines. Thus, this paper presents a methodology for integrating these off-design characteristics in the mixed-integer linear program within REopt, a hybrid DER screening tool. The economic impact of the CHP off-design performance is observed through several application studies of various hybrid system configurations in different climates. Each study indicates how CHP off-design performance influences optimal sizing and dispatch decisions and therefore overall system economic value. We observe through case studies that modeling without the off-design effects, depending on the CHP prime mover and site, can result in Net Present Value predictions of hybrid systems that can be overoptimistic in frequently hot climates (up to 52%), too conservative in frequently cold climates (up to 11%), or unaffected (+/-1%) in temperate climates. Cases also highlight several advantages of hybrid systems relative to non-hybrid systems such as total economic value and the systems' ability to mitigate potentially negative consequences attributed to off-design performance.

ambient de-rate↗

Design and performance analysis of a Swirl Pintle injector for a 1 MW th pressurized oxy-coal combustor

Pressurized Oxy-coal combustion has the potential to achieve high thermal efficiency by recovering the latent heat of steam from flue gases and providing options for up to 95% carbon capture. Here, this study proposes a novel burner technology for pressurized oxy-coal combustion and investigates its operability. Three burner versions are designed and tested; no swirl, swirl numbers 0.9 and 1.2 to identify optimum design parameters and performance. A commercially available Dantec Dynamics software is used to conduct the shadowgraph experiments to observe burner performance. Coal water slurry is used as fuel with three different slurry ratios where the coal percentage by weights were 30, 40 and 50. Droplet size, distribution, spray angle and jet breakup lengths are measured and analyzed to quantify the performance. The study found that increasing the swirl number enhanced atomization. Implementing swirlers allowed the jet to spread through faster primary jet separation, thus improving atomization. In addition, higher slurry ratios improved the generation of smaller particles. However, it was also found that excessive increases in oxidizer momentums negatively impact the atomization process by jet shrinkage. The study concluded that operating a pintle burner at 1.2 swirl conditions with a 40/60 slurry ratio produces optimum performance.

42 ENGINEERING↗

Comprehensive evaluation of commercially scalable atomic-layer-deposited alumina coating impact on full cell battery performance across varied test conditions

Atomic Layer Deposition (ALD) has emerged as a strategic enhancement method for lithium-ion battery (LIB) materials offering potential benefits and durability benefits for industrial battery production. However, the translation from laboratory achievements to commercial-scale applications has been limited. Here, this study aims to bridge this gap by comprehensively evaluating the effects of commercially scalable Al 2 O 3 ALD coatings using full pouch cell performance as a means to assess the ALD impact. We utilized large-scale slot-die coating techniques to ensure consistent electrode quality and tested four configurations of pouch cells to analyze the individual effects of ALD coating on anode and cathode electroactive materials. Our extensive testing matrix included long-term cycling, fast discharge, fast charge, leakage current, and high voltage tests. While at lower C-rates (<~1C), the influence of Al 2 O 3 coatings on cell performance is not significant. Fast charging conditions reveal that the anode ALD coating significantly enhances performance via a passivating effect, while on the cathode, it is detrimental, potentially due to increased resistance of the thin interfacial layer formed during the ALD processing. Leakage current and high-voltage tests show that the application of ALD coatings on either anode or cathode effectively minimizes side reactions at the electrode-electrolyte interface. Additionally, ALD coatings significantly mitigate concentrated and localized lithium plating on the anodes. These insights provide a valuable understanding of the potential of ALD technologies in LIB manufacturing to tailor cell performance, paving the way for safer, more efficient, and cost-effective battery solutions.

25 ENERGY STORAGE↗

Methane foam performance in oil-wet unconsolidated porous media: A systematic experimental investigation at reservoir conditions

Methane foam performance was systematically evaluated using high-pressure and high-temperature experiments performed on oil-wet proppant packs. The sensitivities of foam performance to various key factors, including surfactant concentration, foam quality, total injection rate, salinity, operating pressure, and initial oil saturation were examined. The results showed that even though the foamability and foam strength in oil-wet proppant packs were adversely affected by wettability and presence of oil, the steady-state pressure drops across the proppant packs were insensitive to the quantity of oil initially present. The presence of oil above the critical oil saturation impeded the onset of foam generation. This suggested that the foamability of surfactants depends on the synergetic effects of surfactant’s ionic nature and foam parameters, such as foam quality and total injection rate, on their ability to reduce the oil saturation to a threshold value below which favorable bubble generation sites could be created. It was observed that, for low injection rate, anionic surfactant was ineffective at low salinity conditions, while amphoteric agent performed well at all salinities. Additionally, an increase in salinity resulted in enhanced pressure drop across the proppant packs for both anionic and amphoteric surfactants. Further, the results also established that too high operating pressures are somewhat detrimental to the foam strength and stability, irrespective of the ionic nature of foaming agents and the wettability of the porous medium. For the anionic surfactant, the increase in the total flow rate was found to mitigate the adverse effects of low salt concentration and operating pressure. Results from quality-sensitivity foam tests identified two regions for the foam behavior, named low-quality and high-quality regimes, separated by the transition foam quality. Finally, we discuss the implications of the results for the design and effective implementation of enhanced oil recovery (EOR) schemes that deploy hydrocarbon-based foams.

02 PETROLEUM↗

Boosting the performances of protonic solid oxide fuel cells for co-production of propylene and electricity from propane by integrating thermo- and electro- catalysis

Protonic solid oxide fuel cells (p-SOFC) integrated with clean thermal energy sources are promising platforms for decarbonized chemical production in addition to power generation, such as on-purpose propylene production from propane dehydrogenation (PDH). The catalytic performance of the conventional nickel-cermet-based anode materials in p-SOFC for propane conversion is restrained by their low active surface area and proneness to coking. In this work, by integration of a highly efficient industry-relevant thermal catalyst PtGa/ZSM-5 for PDH reaction, we demonstrate that both the electrochemical and catalytic performance of the propane-fueled p-SOFC can be effectively enhanced. The PtGa catalyst integrated p-SOFC exhibits a peak power density of 93 mW cm -2 at 600°C, which is greater by about 100% and 50% than that without catalyst or with a perovskite-based (Pr 0.3 Sr 0.7 ) 0.9 Ni 0.1 Ti 0.9 O 3 (PSNT) catalyst layer, respectively. The PDH activity and olefin selectivity of the PtGa catalyst is also significantly higher than that of the PSNT catalyst. In addition, much improved coke tolerance and propylene selectivity (over 90%) compared to the catalyst-free Ni-cermet anode materials were achieved by integrating the industrial catalyst layer. The propane conversion can be further improved by an applied current density, whereas the olefin selectivity is almost unaltered. The excellent performance of the PtGa catalyst integrated p-SOFC is attributed to the high surface area, intrinsically high catalytic activity, selectivity, and anti-coking properties of the catalytic layer for propane conversion. In conclusion, this work provides a general approach and a case study for boosting the performances of p-SOFCs in chemical production by integrating thermo- and electro- catalysis.

30 DIRECT ENERGY CONVERSION↗

Fluid dynamic and thermal performance of a slotted cylinder at low Reynolds number

The fluid dynamic and thermal performance of a circular cylinder with a slot parallel to the flow is numerically investigated. The study utilized the semi-implicit finite volume multi-material algorithm MPM-ICE, a component of the Uintah framework. The normalized slot width s/D ranges from 0.1 - 0.3, introducing an additional heat transfer surface area between ~ 10 and ~ 50%, and a mass reduction between ~ 13 and ~ 38% in the cylinder. We assumed two-dimensional incompressible flow and simulated a Reynolds number Re D between 100 and 1000. The slotted cylinders are found to have a total drag force reduction up to ~ 45%, compared to a solid cylinder despite the additional viscous drag force in the slot. Convection heat transfer is enhanced up to ~ 70%. Further, the slotted cylinder performance index, defined as the ratio of the heat rate to the drag force, increases up to maximum of ~ 3, indicating better overall thermal fluid performance. An entropy analysis showed the best performance index occurs at the highest Re D . Correlations for drag coefficient and Nusselt number are proposed along with an entropy optimization method.

42 ENGINEERING↗

Modeling the performance and faradaic efficiency of solid oxide electrolysis cells using doped barium zirconate perovskite electrolytes

Y-doped BaZrO 3 (BaZr 1 x Y x O 3 δ , or “BZY”), a proton-conducting ceramic featuring high bulk conductivity and good chemical stability, is a promising electrolyte material for solid oxide electrolysis cells. Further doping with Ce and/or Yb (creating materials “BCZY” and “BCZYYb”) can improve conductivity and sintering properties, but at significant penalty to cells’ faradaic efficiency (FE). Studies have proposed that reduction of lattice Ce can occur in the hydrogen electrode, which consumes some hydrogen produced by the hydrogen evolution reaction, leading to decreased FE. Despite studies suggesting this phenomenon, the mechanism is largely unknown. In this work, we developed a multiphysics model to study the transport of multiple defect species and the performance of BZY, BCZY, and BCZYYb, capturing the tradeoff between enhanced performance at the cost of FE for BCZY and BCZYYb electrolytes compared to BZY. We also found that increasing the water content of the anode gas supply lowers the current output of the cell but results in better FE. The model, which uses several parameters previously unavailable in the literature, was validated to experiments varying temperature, steam water content, and electrolyte material, as well as two performance metrics (performance curves and FE). Results verify and explain observed trends, informing future work on Ce-doped BZY electrolytes.

08 HYDROGEN↗

High-performance SO 2 -depolarized electrolysis cell using advanced polymer electrolyte membranes

Three different proton conducting polymeric membrane materials (Nafion® 115, Nafion® 212, and sulfonated Diels-Alder polyphenylene [SDAPP]) were evaluated for use in SO 2 -depolarized electrolyzers for the production of hydrogen via the hybrid sulfur cycle. Their performance was measured using different water feed strategies to minimize overpotential losses while maintaining high product acid concentration. Both thin membranes (Nafion® 212 and SDAPP) showed performance superior to that of the thicker Nafion® 115. Here, the SDAPP membrane electrode assembly (MEA) performed well at higher acid concentrations, maintaining low ohmic and kinetic overpotentials. Finally, short-term (100-h) stability tests under constant current conditions showed minimal degradation for the SDAPP and Nafion® 212 MEAs. SDAPP MEA performance approached the targets needed to make the hybrid sulfur cycle a competitive process for hydrogen production (product acid concentration ≥65 wt% H 2 SO 4 at ≤ 0.6-V cell potential and ≥0.5 A-cm –2 current density).

08 HYDROGEN↗

Zinc treatment to enhance nickel electrode performance for liquid alkaline water electrolyzers

Raney Ni treatment is introduced to the surface of Ni mesh anode electrodes, enhancing liquid alkaline water electrolyzer performance. The surface of the Ni mesh is alloyed with Zn, deposited by either an aqueous infiltration of Zn salt or direct reaction with Zn foil. The extent of alloying is controlled by a heat treatment step. For both processes, fine porosity and enhanced surface area are obtained after leaching the Zn out of the surface alloy layer. The observed electrode surface structure and performance is quite sensitive to the thermal treatment temperature. The enhanced surface area improves full cell performance by 90 mV for infiltrated Zn treated at 600 °C and by 185 mV for Zn foil reacted at 425 °C (at 2 A cm −2 and 80 °C). In conclusion, the Zn treatment methods produce stable operating performance, exhibiting no decay after 150 h for the infiltrated Zn treated at 600 °C, and a decay rate of 4.6 μV h −1 over 100 h for the Zn foil reacted at 425 °C (at 1 A cm −2 and 80 °C).

LAWE↗

A Performance analysis of the Claridge-Culp-Liu dehumidification process: A novel approach for drying moist air based on membrane separation, vacuum compression and sub-atmospheric condensation

This article covers a basic model for analyzing the performance of the Claridge-Culp-Liu dehumidification process. The fundamental process efficiency limit for dehumidification is close to COP Carnot , but for the eight dehumidification cases examined, the limiting or ideal energy use required is 26% to 56% that of a Carnot condensing system as shown in an earlier paper. The model presented in this paper is used to show the membrane system performance reduction caused by finite membrane area, finite water vapor permeance, non-zero air permeance, non-zero system air pressure drop, non-ideal compressors, vacuum pumps, and condensers. The performance of a “conservative” membrane system based on the use of existing components is computed for eight specific conditions along with that of a “target” system that assumes expected component performance after additional future component development. The “conservative” membrane system would use 36% to 66% as much energy as a system with a COP=7 chiller to produce the same dehumidification for the eight cases examined while the “target” system would use 15% to 40% the energy of a system with a COP=7 chiller. In addition to the significant energy reduction over conventional technology, the membrane system offers the advantages of: 1) no HFC refrigerant use; 2) direct isothermal control over humidity ratio setpoint; 3) maximum capacity occurs at design conditions; and 4) system generates pure water extracted from air as a by-product.

42 ENGINEERING↗

Multi-objective optimization of low-GWP mixture composition and heat exchanger circuitry configuration for improved system performance and reduced refrigerant flammability

The recently introduced hydrofluoroolefin (HFO) refrigerants, including R1234yf and R1234ze(E), have significantly lower global warming potentials (GWPs) than traditional hydrofluorocarbon (HFC) refrigerants like R410A. However, prior tests show that direct drop-in of pure R1234yf or R1234ze(E) into equipment designed for R410A results in a decrease in heat exchanger capacity and the system coefficient of performance. The primary reason is the lower in-tube heat transfer performance of R1234yf and R1234ze(E) compared with that of R410A. To address this issue, previous studies have mixed the mildly flammable HFC R32 with HFOs to improve system performance, with HFC R125 also added to suppress flammability. Previous studies selected compositions based on simple cycle analyses and did not consider modifications of the heat exchanger circuitry configuration to adapt to the new refrigerants. This study presents a novel multi-objective optimization approach to design a refrigerant composition that maximizes energy efficiency within flammability and GWP limits. The approach in this work simultaneously optimizes mixture composition and heat exchanger circuitry configuration. A case study on a rooftop unit indicates that, compared with mixture-only optimization, simultaneous optimization of mixture and heat exchanger circuitry yields a 5.9% improvement in cycle efficiency and a 48.6% reduction in refrigerant flammability with a GWP of 268. Circuitry optimization using refrigerants with different temperature glides shows that the larger the temperature glide is, the larger EER improvement is obtained. The results show that zeotropic blends with a large temperature glide are more sensitive to the refrigerant circuitry than pure refrigerants and may suffer significant performance degradation with subpar heat exchanger circuitry design. The proposed optimization approach is generally applicable to mixtures with any number of components. Using this approach to design a HVAC system can yield higher system efficiency within flammability and GWP constraints.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An economic analysis of the role of materials, system engineering, and performance in electrochemical carbon dioxide conversion to formate

The development of technologies that utilize carbon dioxide is important to mitigating climate change. The electrochemical reduction of carbon dioxide is one technology that can utilize greenhouse gasses that would be otherwise be emitted to the atmosphere by producing chemicals and fuels from carbon dioxide and electricity. Significant progress has been made in the experimental performance of carbon dioxide reduction systems with novel catalyst designs, new materials, and systems engineering; however, no work has linked such changes in stack design and materials to capital costs for the stack itself. In this study, we present an analysis that accounts for and analyzes the impacts of alternative materials and system architectures on manufactured costs of carbon dioxide reduction stacks, thus providing a framework to understand exactly how these advances impact the at-scale capital costs of these systems. Specifically, we consider the impact that the addition of a catholyte buffer layer has on an electrolyzer reducing carbon dioxide to formate, finding that the cost of manufacturing this part only increases stack costs by about $30/m 2 at high manufacturing rates, while previous work finds that this part improves system performance. This work shows that the links between system performance, materials, and costs are nonlinear, and that achieving low-cost scalability requires optimization of not just performance parameters but also the use of low-cost and highly scalable materials. These results bridge experimental and techno-economic analysis of processes for carbon dioxide reduction, informing researchers by providing a quantifiable estimate of the impact of advances in electrochemical carbon dioxide reduction technology on manufactured stack capital costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Performance and long-term stability of CO 2 conversion to formic acid using a three-compartment electrolyzer design

The electrochemical reduction of CO 2 to formate and formic acid has attracted a great amount of academic and commercial interest over the past five years. A number of experimental studies have generated data on the Faradaic performance and stability of various candidate catalyst materials in producing formate or formic acid. However, most of the data has been conducted at low current densities and over short time periods, typically hours to days. There is a critical need in providing long-term catalyst stability as well as electrolyzer-based operating data, which are needed for the commercial scale-up and operation of this technology, especially at high current densities. In this paper, the electrochemical CO 2 conversion to pure formic acid was conducted using a three-compartment design electrolyzer, demonstrating electrolyzer catalyst and performance stability for over 1000 h at current densities up to 200 mA cm -2 . Depending on the operation conditions, the electrolyzer directly produced a 6.03 to 12.92 wt% (1.3 to 2.8 M) formic acid product at Faradaic efficiencies ranging between 73.0 to 91.3%. Data on electrolyzer performance, including formic acid product generation rate, energy efficiency, and energy consumption are reported at three different current densities, 100, 200, and 250 mA cm -2 . Finally, a long term 1000 h electrolyzer stability run at 200 mA cm -2 is presented, providing information on the operating conditions required in obtaining stable electrolyzer performance. All the data will be extremely useful in the commercial scale-up of this technology.

10 SYNTHETIC FUELS↗