Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ozone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Natural variability of tropical upper stratospheric ozone inferred from the Atmosphere Explorer backscatter ultraviolet experiment

Analysis of backscattered ultraviolet radiances observed at tropical latitudes by the Atmosphere Explorer-E satellite reveals both annual and semiannual cycles in upper stratospheric ozone. The annual variation dominates the signal at wavelengths which sense ozone primarily above 45 km while below this, to the lowest altitude sensed, 35 km, the semiannual component has comparable amplitude. Comparison of radiance measurements taken with the same instrument at solar minimum during 1976 and solar maximum in 1979 show no significant differences. This suggests that variations in upper stratospheric ozone over the solar cycle are small, although the data presently available do not allow a definite conclusion.

Frederick, J. E.↗

Total ozone trend significance from space time variability of daily Dobson data

Estimates of standard errors of total ozone time and area means, as derived from ozone's natural temporal and spatial variability and autocorrelation in middle latitudes determined from daily Dobson data are presented. Assessing the significance of apparent total ozone trends is equivalent to assessing the standard error of the means. Standard errors of time averages depend on the temporal variability and correlation of the averaged parameter. Trend detectability is discussed, both for the present network and for satellite measurements.

Wilcox, R. W.↗

Cabin ozone and tropopause definition

A method to estimate ozone profiles is based on knowing the total ozone which may come from any observational system available such as Dobson photometers that are available from NMC forecasts and used operationally in flight planning. From this an ozone profile at selected pressure levels is obtained. The technique was based on five years of ozonesonde data. So far, models have been developed for winter, spring, and fall.

Belmont, A. D.↗

Error in Dasibi flight measurements of atmospheric ozone due to instrument wall-loss

Theory suggests that in laminar flow the percent loss of a trace constituent to the walls of a measuring instrument varies as P to the -2/3, where P is the total gas pressure. Preliminary laboratory ozone wall-loss measurements confirm this P to the -2/3 dependence. Accurate assessment of wall-loss is thus of particular importance for those balloon-borne instruments utilizing laminar flow at ambient pressure, since the ambient pressure decreases by a factor of 350 during ascent to 40 km. Measurements and extrapolations made for a Dasibi ozone monitor modified for balloon flight indicate that the wall-loss error at 40 km was between 6 and 30 percent and that the wall-loss error in the derived total ozone column-content for the region from the surface to 40 km altitude was between 2 and 10 percent. At 1000 mb, turbulence caused an order of magnitude increase in the Dasibi wall-loss.

Ainsworth, J. E.↗

A technique for evaluating the influence of spatial sampling on the determination of global mean total columnar ozone

A technique is described for providing a means of evaluating the influence of spatial sampling on the determination of global mean total columnar ozone. A finite number of coefficients in the expansion are determined, and the truncated part of the expansion is shown to contribute an error to the estimate, which depends strongly on the spatial sampling and is relatively insensitive to data noise. First and second order statistics are derived for each term in a spherical harmonic expansion which represents the ozone field, and the statistics are used to estimate systematic and random errors in the estimates of total ozone.

Tolson, R. H.↗

Total ozone seasonal and interannual variations derived from the 7 year Nimbus-4 BUV data set

BUV total ozone data from the Nimbus 4 satellite were used to derive the seasonal and interannual variations of total ozone over a 7-year period. The variations were studied using harmonic and superposition analyses of zonal mean data at 10 deg latitudinal increments. Harmonic analysis of the zonal mean data revealed a clear quasibiennial oscillation (QBO) strongest in the tropics and at high latitudes in the Southern Hemisphere. An estimation of the QBO period using a superposition analysis for each latitude zone revealed a decreasing period with latitude in both hemispheres. A maximum period of 27 months occurs in the tropics, while the minimum period in the Northern Hemisphere is about 20 months. This decrease in QBO period with latitude implies that the observed QBO in ozone at low and high latitudes are not directly related. The results do indicate, however, that the interannual variations are latitude dependent.

Hilsenrath, E.↗

Ground-based lidar measurements of ozone, water vapor and aerosols in the lower stratosphere and troposphere

Lidar measurements of ozone and water vapor concentrations were performed during several field experiments in 1980-1981 by means of the differential absorption laser technique. Profiles up to 26 km for ozone and up to 9 km for water vapor are presented. Also, a lidar survey of aerosol layers ranging from 12 to 23 km were performed following the Mt. St. Helens major eruption (May 1980). Experiments were conducted at the CNRS lidar facility of the Haute Provence Observatory which is located in southern France (44 deg N, 5 deg E). For ozone a vertical profile is recorded in three sequences, each requiring 15 min of acquisition time. The relative accuracy is better than 5 percent at the lower altitude and falls to 20 percent at 25 km. For water vapor the time sequences are 4 min or 8 min long and the accuracy is better than 10 percent in the lower troposphere.

Flamant, P. H.↗

Ozone flow visualization techniques

Flow visualization techniques using ozone for tracing gas flows are proposed whereby ozone is detected through its strong absorption of ultraviolet light, which is easily made visible with fluorescent materials, or through its reaction with nitric oxide to form excited nitrogen dioxide, which in relaxing emits detectable light. It is shown that response speeds in the kHz range are possible with an ultraviolet detection system for initial ozone concentrations of about 1%.

Dickerson, R. R.↗

Direct measurements of ozone and nitrogen dioxide photolysis rates in the troposphere

The photolysis frequencies of ozone and nitrogen dioxide were measured under a variety of conditions commonly found in the troposphere. Ozone photolysis frequencies show a strong dependence on solar zenith angle, overhead ozone column, and temperature, but only a weak dependence on altitude (when only downward radiation is detected). Nitrogen dioxide photolysis frequencies also show strong dependence on solar zenith angle, but show little dependence on temperature, pressure, or altitude. Both j values are strongly affected by cloud cover, but aerosol loading has much less effect. The disagreement of measured j(O3) and j(NO2) with many modeled values, especially disagreement over altitude dependence, shows that atmospheric UV radioactive processes are complicated and poorly understood, although experimental conditions may not always be applicable to conditions modeled.

Dickerson, R. R.↗

Total ozone variations 1970-74 using Backscattered Ultraviolet /BUV/ and ground-based observations

The most long-lived satellite set of ozone observations, to date, is that derived from the Backscatter Ultraviolet (BUV) ozone sensor on Nimbus 4 and extends from April 1970 through 1976. Unfortunately, this experiment suffered spacecraft power limitations which limited the spatial and temporal coverage and also appears to have suffered from long-term drifts which may be associated with changes in the instrument characteristics or the incident solar flux. Techniques have been developed to account for these problems, and this paper presents results of the BUV total ozone variations and compares them with those from ground-based observations, specifically the computations of Angell and Korshover (1978). After adjustments for the spatial gaps and comparison with concurrent Dobson ground-based observations, no significant trend was found in the BUV data over the years 1970-74. This finding is in contrast to a general decrease of about 2% during the same period appearing in the data of Angell and Korshover. The difference in these results is discussed in terms of the geographic sampling and the methods of hemispheric integration.

Miller, A. J.↗

An intercomparison of ground-based total ozone instruments

Five ground-based total ozone spectrophotometers were intercompared at Wallops Island, VA between October 1979 and January 1981. The tests were conducted to evaluate the stability and accuracy of each instrument over an extended time period. Acceptable performance regarding these two characteristics is essential if an instrument is to be useful in field measurements and network monitoring of the atmospheric total ozone content. The Dobson spectrophotometer was used as the standard of comparison for the Brewer grating spectrophotometer, the USSR M-83 ozonometer, the Canterbury filter photometer, and the SenTran filter photometer. The grating instrument was found to be potentially the equal of the Dobson but was subject to unreliable performance by its rather sophisticated electronic components. The filter photometers performed acceptably for short periods but filter aging and eventual degradation rendered both units unusable before the end of the intercomparison. Finally, the M-83 results were found to be in acceptable agreement with the Dobson throughout the period when certain qualifications are invoked. The accuracy of a single M-83 ozone measurement may be low. Averages tend to improve its agreement with the Dobson.

Parsons, C. L.↗

Atmospheric ozone determination by solar occultation using the UV spectrometer on the Solar Maximum Mission

The UV spectrometer polarimeter instrument on the Solar Maximum Mission spacecraft has been used to measure ozone in the 53-75 km altitude interval by the technique of solar occultation. A 1 x 180 arcsec entrance aperture spectrometer with 0.04-A spectral resolution was employed. Resulting high-quality data are reduced by expressing measured UV attenuation as a Volterra integral equation. Solution of the equation is accomplished by expressing the integral in terms of a series representing the sum of ozone densities contained in concentric shells through tangent points separated by specified altitude increments. Sample ozone vs altitude profiles are presented for the equatorial region. These data show reproducibility to better than 10%. The density at 60 km is 7.3 + or - 0.15 x 10 to the 9th/cu cm for 2.5 deg latitude and longitudes between 81 and 105 deg west in September 1980. Density vs altitude profile exhibits changes in slope between 50 and 75 km.

Aikin, A. C.↗

Microwave measurement of stratospheric and mesospheric ozone

It is pointed out that ozone has a rich rotational spectrum with many lines at millimeter wavelengths. Measurement of these lines can provide a means of remotely sensing stratospheric and mesospheric ozone. Technology has recently advanced to the state where it is reasonable to consider monitoring upper atmospheric O3 on a global scale by microwave radiometers in earth orbit. An investigation indicates that approximately 1% accuracy and approximately 2 km vertical resolution O3 mixing ratio measurements are reasonable goals for limb-viewing microwave radiometers in earth orbit. Mesospheric ozone can also be measured by the considered techniques using stronger (but more temperature-sensitive) O3 lines. A balloon-borne microwave limb sounder has recently been constructed to test the practical limitations on the measurement concepts. Also under study is a microwave limb sounder for operation in earth orbit.

Waters, J. W.↗

Seasonal variations of total ozone revealed by the Nimbus-4 BUV data set

Backscattered ultraviolet (BUV) data from the Nimbus-4 spacecraft for the period 1970-1977 have been processed to a refined level. The seasonal and interannual variations of total ozone are examined on a global scale, using daily zonal means of 10 deg latitude bands and a time-latitude cross section. A harmonic analysis was performed on the daily zonal means and the amplitude, days of peak ozone values, and percentage of variance were computed for the annual, semiannual and higer harmonics for several years and each year. A clear quasi-biennial oscillation (QBO) was revealed from the tropics to midlatitudes after removing the mean annual wave. Asymmetries in the annual wave in the two hemispheres found earlier for the period 1970-1972 persist through the entire observation period. Interannual variations appear to be the result of the QBO of ozone from low to midlatitudes. Asymmetries in the QBO amplitude phase, and period were also detected in the two hemispheres.

Hilsenrath, E.↗

Ozone photochemistry and OH - A two-dimensional model study

Recent measurements of key HO(x) reaction rates are presented which imply that OH concentrations at altitudes below 30 km are lower than those predicted by current photochemical models. The consequences of the lower OH abundances are examined with respect to calculated perturbations of ozone by added nitrogen oxides, chlorine, and water vapor. Consideration is also given to the perturbation of stratospheric ozone by continuing release of chlorofluoromethanes in light of the new HO(x) reaction rates. The ozone loss is found to be reduced by about 25% compared with earlier estimates, mainly because the reduced OH abundance below 30 km slows the reaction between OH and HCl.

Whitten, R. C.↗

Stratospheric ozone and temperature perturbations - An examination of synergistic effects

Experiments have been carried out to investigate the time-dependent effects of combined releases of CO2 and chlorofluoromethanes (CFM) on stratospheric ozone and temperature. The analysis also examines the effects of steady-state variations in CFM, CO2, and solar UV flux levels on surface temperature and latitudinal temperature distribution. Results indicate that ozone depletion, due to combined effects of CO2 and CFM increases, may show a local maximum of about 6% at about the time CO2 doubles (approximately 60 yr from now). After that, the downward trend in ozone due to Cl(x) catalytic destruction is reestablished and continues, reaching approximately 15% depletion. At steady state, compensation due to CO2 increases is approximately 1% for two to four times the ambient CO2 levels.

Callis, L. B.↗

Observations of the interaction of ozone and dynamics

Data on the global distribution of temperature and ozone obtained with the Limb Radiance Inversion Radiometer which flew on the Nimbus 6 spacecraft are analyzed within the conceptual framework of Hartmann and Garcia (1979). The analysis supports the conclusion that ozone perturbations are dynamically controlled when the photochemical time constant is much greater than the dynamical time constant; when the photochemical constant is much less than the dynamical constant, ozone perturbations are photochemically controlled. It is also shown that the transports of planetary waves, or eddy transports, appear to be strongly localized in the region between the regimes in which dynamical and photochemical controls operate.

Gille, J. C.↗

Numerical experiments with a general circulation model concerning the stratospheric distribution of ozone

Three experiments have been performed using a three-dimensional, spectral quasi-geostrophic model in order to investigate the sensitivity of ozone transport to tropospheric orographic and thermal effects and to the zonal wind distribution. In the first experiment, the ozone distribution averaged over the last 30 days of a 60 day transport simulation was determined; in the second experiment, the transport simulation was repeated, but nonzonal orographic and thermal forcing was omitted; and in the final experiment, the simulation was conducted with the intensity and position of the stratospheric jets altered by addition of a Newtonian cooling term to the zonal-mean diabatic heating rate. Results of the three experiments are summarized by comparing the zonal-mean ozone distribution, the amplitude of eddy geopotential height, the zonal winds, and zonal-mean diabatic heating.

Kurzeja, R. J.↗