Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OUTDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Thermal performance of honeywell double covered liquid solar collector

The test procedures and results obtained during an evaluation test program to determine the outdoor performance characteristics of the Honeywell liquid solar collector are presented. The program was based on the thermal evaluation of a Honeywell double covered liquid solar collection. Initial plans included the simultaneous testing of a single covered Honeywell collector. During the initial testing, the single covered collector failed due to leakage; thus, testing continued on the double covered collector only. To better define the operating characteristics of the collector, several additional data points were obtained beyond those requested.

Losey, R.↗

Concorde noise-induced building vibrations John F. Kennedy International Airport

The outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at six home sites along with the associated vibration levels in the walls, windows, and floors of these test homes. Limited subjective tests conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise showed that both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Preliminary results indicate that the relationship between window vibration and aircraft noise is: (1) linear, with vibration levels being accurately predicted from OASPL levels measured near the window; (2) consistent from flyover to flyover for a given aircraft type under approach conditions; (3) no different for Concorde than for other conventional jet transports (in the case of window vibrations induced under approach power conditions); and (4) relatively high levels of window vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde source characteristics.

Mayes, W. H.↗

Assessment of the impact of increased solar ultraviolet radiation upon marine ecosystems

Specifically, the study has addressed the following: (1) potential for irreversible damage to the productivity, structure and/or functioning of a model estuarine ecosystem by increased UV-B radiation or ecosystems highly stable or amenable to adaptive change, and (2) the sensitivity of key community components (the primary producers, consumers, and decomposers) to increased UV-B radiation. Three areas of study were examined during the past year: (1) a continuation of the study utilizing the two seminatural ecosystem chambers, (2) a pilot study utilizing three flow-through ecosystem tanks enclosed in a small, outdoor greenhouse, and (3) sensitivity studies of representative primary producers and consumers.

Vandyke, H.↗

Use of the Marshall Space Flight Center solar simulator in collector performance evaluation

Actual measured values from simulator checkout tests are detailed. Problems encountered during initial startup are discussed and solutions described. Techniques utilized to evaluate collector performance from simulator test data are given. Performance data generated in the simulator are compared to equivalent data generated during natural outdoor testing. Finally, a summary of collector performance parameters generated to date as a result of simulator testing are given.

Humphries, W. R.↗

Flight service evaluation of Kevlar-49 epoxy composite panels in wide-bodied commercial transport aircraft

Kevlar-49 fairing panels, installed as flight service components on three L-1011s, were inspected after four years' service, and found to be performing satisfactorily. The Kevlar-49 components were all found to be performing satisfactorily in service with no major problems, or any condition requiring corrective action. The only defects noted were minor impact damage, and a minor degree of fastener hole fraying and elongation. These are for the most part comparable to damage noted on fiberglass fairings. A concurrent investigation was conducted on Kevlar-49/epoxy coupons exposed to an outdoor environment over a three year period at various locations providing a variety of climatic conditions. Weight changes and retention of mechanical properties were determined after one and three years exposure. A net weight loss occurred due to ultraviolet effects on the unpainted specimens. Mechanical property retentions were satisfactory with most specimens retaining well over 80% of their original value.

Stone, R. H.↗

Indoor thermal performance evaluation of the SEPCO air collector

The procedures used and the results obtained during the evaluation test program on the Solaron solar air collector, model EF-212, under simulated conditions for comparison with data collected in outdoor tests on the same collector are given. The test article was a single glazed collector with a nonsensitive absorber plate, aluminum box frame, and one inch isocyanurate foam insulation.

Source record↗

Accelerated/abbreviated test methods, study 4 of task 3 (encapsulation) of the low-cost silicon solar array project

Inherent weatherability is controlled by the three weather factors common to all exposure sites: insolation, temperature, and humidity. Emphasis was focused on the transparent encapsulant portion of miniature solar cell arrays by eliminating weathering effects on the substrate and circuitry (which are also parts of the encapsulant system). The most extensive data were for yellowing, which were measured conveniently and precisely. Considerable data also were obtained on tensile strength. Changes in these two properties after outdoor exposure were predicted very well from accelerated exposure data.

Kolyer, J. M.↗

Environmental effects on composites for aircraft

A number of ongoing, long-term environmental effects programs for composite materials are evaluated. The flight service experience was evaluated for 142 composite aircraft components after more than 5 years and 1 million successful component flight hours. Ground-based outdoor exposures of composite material coupons after 3 years of exposure at 5 sites have reached equilibrium levels of moisture pickup which are predictable. Solar ultraviolet-induced material loss is discussed for these same exposures. No significant degradation was observed in residual strength for either stressed or unstressed specimens, or for exposures to aviation fuels and fluids.

Pride, R. A.↗

Concorde noise-induced building vibrations: John F. Kennedy International Airport

Outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at eight homesites and a school along with the associated vibration levels in the walls, windows, and floors at these test sites. Limited subjective tests were conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise. Both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Seated subjects more readily detected floor vibrations than wall or window vibrations. Aircraft noise generally caused more window vibrations than common nonaircraft events such as walking and closing doors. Nonaircraft events and aircraft flyovers resulted in comparable wall vibration levels, while floor vibrations were generally greater for nonaircraft events than for aircraft flyovers. The relationship between structural vibration and aircraft noise is linear, with vibration levels being accurately predicted from overall sound pressure levels (OASPL) measured near the structure. Relatively high levels of structural vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde-source characteristics.

Mayes, W. H.↗

Environmental effects on composites for aircraft

The influence of the operational environment on the behavior of composite materials and aircraft components fabricated with these composite materials was considered. Structural weight savings, manufacturing cost savings, and long-term environmental durability are among the factors examined. The flight service experience to date of composite components is evaluated. In addition, the influence of a number of worldwide, ground based outdoor exposures on the physical and mechanical properties of six composite materials is discussed. In particular, the current extent of the ultraviolet surface degradation and the moisture gained by diffusion is shown.

Pride, R. A.↗

Flight effects on the aerodynamic and acoustic characteristics of inverted profile coannular nozzles, volume 1

Jet noise spectra obtained at static conditions from an acoustic wind tunnel and an outdoor facility are compared. Data curves are presented for (1) the effect of relative velocity on OASPL directivity (all configurations); (2) the effect of relative velocity on noise spectra (all configurations); (3) the effect of velocity on PNL directivity (coannular nozzle configurations); (4) nozzle exhaust plume velocity profiles; and (5) the effect of relative velocity on aerodynamic performance.

Kozlowski, H.↗

Noise-Induced Building Vibrations Caused by Concorde and Conventional Aircraft Operations at Dulles and Kennedy International Airports

Outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded, as were the associated vibration levels in the walls, windows, and floors at building test sites. In addition, limited subjective tests were conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise. Representative peak levels of aircraft noise-induced building vibrations are reported and comparisons are made with structural damage criteria and with vibration levels induced by common domestic events. In addition, results of a pilot study are reported which indicate the human detection threshold for noise-induced floor vibrations.

Mayes, W. H.↗

U.S. terrestrial solar cell calibration and measurement procedures

An outline is presented of changes in measurement procedures concerning solar cells. Outdoor measurements of cell performance based on pyranometer or pyrheliometer determination of intensity are discouraged. The absolute scale of irradiance is to be adopted as soon as possible. The standard atmosphere conditions are 1000 W/sq m irradiance, temperature 28 C, air mass 1.5, and precipitable water vapor content of 2 cm. The allowable light sources for solar simulation are short arc xenon lamps, pulsed xenon lamps, and dichroic filtered tungsten lamps. Key considerations in the design of a reference cell are considered and approaches for the matching of a reference cell to a test cell or modules are discussed.

Brandhorst, H. W., Jr.↗

Building penetration analysis

The airborne exposure to carbon fibers experienced within a building may be substantially less than that outside the building. By their very nature, buildings provide a barrier to the free flow of airborne particulate contaminants through the air space they occupy. The objective of this report is an evaluation of the degree to which buildings and other structures will attenuate potential exposures to carbon fibers. Most if not all types of buildings, and all phenomena which may influence the extent to which fibers in outdoor air can penetrate structures are addressed.

Source record↗

Investigation of surface fluctuating pressures on a 1/4 scale YC-14 upper surface blown flap model

Fluctuating pressures were measured at 30 positions on the surface of a 1/4-scale YC-14 wing and fuselage model during an outdoor static testing program. These data were obtained as part of a NASA program to study the fluctuating loads imposed on STOL aircraft configurations and to further the understanding of the scaling laws of unsteady surface pressure fields. Fluctuating pressure data were recorded at several discrete engine thrust settings for each of 16 configurations of the model. These data were reduced using the technique of random data analysis to obtain auto-and cross-spectral density functions and coherence functions for frequencies from 0 to 10 kHz, and cross-correlation functions for time delays from 0 to 10.24 ms. Results of this program provide the following items of particular interest: (1) Good collapse of normalized PSD functions on the USB flap was found using a technique applied by Lilley and Hodgson to data from a laboratory wall-jet apparatus. (2) Results indicate that the fluctuating pressure loading on surfaces washed by the jet exhaust flow was dominated by hydrodynamic pressure variations, loading on surface well outside the flow region dominated by acoustic pressure variations, and loading near the flow boundaries from a mixture of the two.

Pappa, R. S.↗

End-to-end testing

The principle objective of the kinds of demonstration tests that are discussed is to try to verify whether or not carbon fibers that are released by burning composite parts in an aircraft-fuel fires can produce failures in electrical equipment. A secondary objective discussed is to experimentally validate the analytical models for some of the key elements in the risk analysis. The approach to this demonstration testing is twofold: limited end-to-end test are to be conducted in a shock tube; and planning for some large outdoor burn tests is being done.

Pride, R. A.↗

Develop Silicone Encapsulation Systems for Terrestrial Silicon Solar Arrays

The results of a study for Task 3 of the Low Cost Solar Array Project, directed toward the development of a cost effective encapsulation system for photovoltaic modules using silicon based materials, are reported. Results of the following are discussed: (1) weather-ometer stressing vs. weathering history of silicon and silicon modified materials; (2) humidity/temperature cycling exposure; (3) exposure at high humidity/high temperature; (4) outdoor exposure stress; (5) thermal cycling stress; and (6) UV screening agents. The plans for the next quarter are outlined.

Source record↗

Carbon fiber behavior in an enclosed volume

Tests were performed to evaluate the behavior of single carbon fibers existing in an enclosed space such as a room of a building. Three general phenomena were explored: the concentration decay rate of a fiber-charged room, the degree of uniform mixing of fibers within a room, and the effects of fibers being redisseminated off deposition surfaces within a room. The results were required in understanding the ratio of total indoor fiber exposure to total outdoor fiber exposure, a quantity essential to risk analysis. Results indicate that decay rate is predictable within acceptable limits and that homogeneous mixing can always be assumed. Some factors of redissemination are identified and effects discussed.

Harvey, M. C.↗