Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Multiple operating system rotation environment moving target defense

Systems and methods for providing a multiple operating system rotation environment ("MORE") moving target defense ("MTD") computing system are described. The MORE-MTD system provides enhanced computer system security through a rotation of multiple operating systems. The MORE-MTD system increases attacker uncertainty, increases the cost of attacking the system, reduces the likelihood of an attacker locating a vulnerability, and reduces the exposure time of any located vulnerability. The MORE-MTD environment is effectuated by rotation of the operating systems at a given interval. The rotating operating systems create a consistently changing attack surface for remote attackers.

97 MATHEMATICS AND COMPUTING↗

Exploring Operational Safeguards, Safety, and Security by Design to Address Real Time Threats in Nuclear Facilities

Over the last few years, significant attention has been paid to both encourage application and provide domestic and international guidance for designing in safeguards and security in new facilities.1,2,3 However, once a facility is operational, safeguards, security, and safety often operate as separate entities that support facility operations. This separation is potentially a serious weakness should insider or outsider threats become a reality.Situations may arise where safeguards detects a possible loss of material in a facility. Will they notify security so they can, for example, check perimeter doors for tampering? Not doing so might give the advantage to an insider who has already, or is about to, move nuclear material outside the facility building. If outsiders break into a facility, the availability of any information to coordinate the facility’s response through segregated alarm stations or a failure to include all available radiation sensors, such as safety’s criticality monitors can give the advantage to the adversary who might know to disable camera systems, but would most likely be unaware of other highly relevant sensors in a nuclear facility.This paper will briefly explore operational safeguards, safety, and security by design (3S) at a high level for domestic and State facilities, identify possible weaknesses, and propose future administrative and technical methods, to strengthen the facility system’s response to threats.

Schanfein, Mark J.↗

Impact of Reactor Operating Parameters on Cask Reactivity in BWR Burnup Credit

This paper discusses the effect of reactor operating parameters used in fuel depletion calculations onspent fuel cask reactivity, with relevance for boiling-water reactor (BWR) burnup credit (BUC)applications. Assessments that used generic BWR fuel assembly and spent fuel cask configurationsare presented. The considered operating parameters, which were independently varied in thedepletion simulations for the assembly, included fuel temperature, bypass water density, specificpower, and operating history. Different operating history scenarios were considered for the assemblydepletion to determine the effect of relative power distribution during the irradiation cycles, as wellas the downtime between cycles. Depletion, decay, and criticality simulations were performed usingcomputer codes and associated nuclear data within the SCALE code system. Results quantifying thedependence of cask reactivity on the assembly depletion parameters are presented herein.

Ilas, Germina↗

Optimizing Biorefinery Design and Operations via Linear Programming Models

The ability to assess and optimize economics of biomass resource utilization for the production of fuels, chemicals and power is essential for the ultimate success of a bioenergy industry. The team of authors, consisting of members from the National Renewable Energy Laboratory (NREL) and the Idaho National Laboratory (INL), has developed simple biorefinery linear programming (LP) models to enable the optimization of theoretical or existing biorefineries. The goal of this analysis is to demonstrate how such models can benefit the developing biorefining industry. It focuses on a theoretical multi-pathway, thermochemical biorefinery configuration and demonstrates how the biorefinery can use LP models for operations planning and optimization in comparable ways to the petroleum refining industry. Using LP modeling tools developed under U.S. Department of Energy's Bioenergy Technologies Office (DOE-BETO) funded efforts, the authors investigate optimization challenges for the theoretical biorefineries such as (1) optimal feedstock slate based on available biomass and prices, (2) breakeven price analysis for available feedstocks, (3) impact analysis for changes in feedstock costs and product prices, (4) optimal biorefinery operations during unit shutdowns / turnarounds, and (5) incentives for increased processing capacity. These biorefinery examples are comparable to crude oil purchasing and operational optimization studies that petroleum refiners perform routinely using LPs and other optimization models. It is important to note that the analyses presented in this article are strictly theoretical and they are not based on current energy market prices. The pricing structure assigned for this demonstrative analysis is consistent with $4 per gallon gasoline, which clearly assumes an economic environment that would favor the construction and operation of biorefineries. The analysis approach and examples provide valuable insights into the usefulness of analysis tools for maximizing the potential benefits of biomass utilization for production of fuels, chemicals and power.

09 BIOMASS FUELS↗

Operational Performance Risk Assessment in Support of A Supervisory Control System

Supervisory control system (SCS) is developed for multi-unit advanced small modular reactors to minimize human interventions in both normal and abnormal operations. In SCS, control action decisions made based on probabilistic risk assessment approach via Event Trees/Fault Trees. Although traditional PRA tools are implemented, their scope is extended to normal operations and application is reversed; success of non-safety related system instead failure of safety systems this extended PRA approach called as operational performance risk assessment (OPRA). OPRA helps to identify success paths, combination of control actions for transients and to quantify these success paths to provide possible actions without activating plant protection system. In this paper, a case study of the OPRA in supervisory control system is demonstrated within the context of the ALMR PRISM design, specifically power conversion system. The scenario investigated involved a condition that the feed water control valve is observed to be drifting to the closed position. Alternative plant configurations were identified via OPRA that would allow the plant to continue to operate at full or reduced power. Dynamic analyses were performed with a thermal-hydraulic model of the ALMR PRISM system using Modelica to evaluate remained safety margins. Successful recovery paths for the selected scenario are identified and quantified via SCS.

Denning, Richard S.↗

Commissioning and operation of the horizontal test apparatus at SNS

The Spallation Neutron Source (SNS) at Oak Ridge National Lab (ORNL) has built, commissioned and operated a Horizontal Test Apparatus (HTA) vessel in the Radiofrequency Test Facility (RFTF) test cave. It can be operated at 4.5 K using the independent Cryogenic Test Facility (CTF). The HTA is designed to be a single cavity version of an SNS cryomodule with the ability to demount and replace the cavity. It provides the functionality for testing a single dressed SNS medium or high beta Superconducting Radiofrequency (SRF) cavity. The HTA is currently being used in support of R&D for in-situ plasma processing of the cavity's inner niobium surface. The design and commissioning of the HTA at 4.5 K will be presented as well as results from operating the HTA including cool-down, warm-up and steady state operations. Results from plasma processing a warm SCRF cavity in-between cold HTA tests will also be reported.

Kim, Sang-Ho↗

Operation of a cascade air conditioning system with two-phase loop

A method of operating a heat transfer system includes starting operation of a first heat transfer fluid vapor/compression circulation loop including a fluid pumping mechanism, a heat exchanger for rejecting thermal energy from a first heat transfer fluid, and a heat absorption side of an internal heat exchanger. A first conduit in a closed fluid circulation loop circulates the first heat transfer fluid therethrough. Operation of a second two-phase heat transfer fluid circulation loop is started after starting operation of the first heat transfer fluid circulation loop. The second heat transfer fluid circulation loop transfers heat to the first heat transfer fluid circulation loop through the internal heat exchanger and includes a heat rejection side of the internal heat exchanger, a liquid pump, and a heat exchanger evaporator. A second conduit in a closed fluid circulation loop circulates a second heat transfer fluid therethrough.

42 ENGINEERING↗

Proactive Operations and Investment Planning via Stochastic Optimization to Enhance Power Systems Extreme Weather Resilience

We present novel stochastic optimization models to improve power systems resilience to extreme weather events. We consider proactive redispatch, transmission line hardening, and transmission line capacity increases as alternatives for mitigating expected load shed due to extreme weather. Our model is based on linearized or "DC" optimal power flow, similar to models in widespread use by independent system operators (ISOs) and regional transmission operators (RTOs). Our computational experiments indicate that proactive redispatch alone can reduce the expected load shed by as much as 25% relative to standard economic dispatch. This resiliency enhancement strategy requires no capital investments and is implementable by ISOs and RTOs solely through operational adjustments. We additionally demonstrate that transmission line hardening and increases in transmission capacity can, in limited quantities, be effective strategies to further enhance power grid resiliency, although at significant capital investment cost. We perform a cross validation analysis to demonstrate the robustness of proposed recommendations. Our proposed model can be augmented to incorporate a variety of other operational and investment resilience strategies, or combination of such strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Atmospheric Radiation Measurement Climate Research Facility Operations Quarterly Report April 1-June 30, 2017

Individual datastreams from instrumentation at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility fixed and mobile research observatories (sites) are collected and routed to the ARM Data Center (ADC). The Data Management Facility (DMF), a component of the ADC, executes datastream processing in near-real time. Processed data are then delivered approximately daily to the ARM Data Archive, also a component of the ADC, where they are made freely available to the research community. For each instrument, ARM calculates the ratio of the actual number of processed data records received daily at the ARM Data Archive to the expected number of data records. DOE requires national user facilities to report time-based operating data. The requirements involve: Actual hours of operation (ACTUAL)—24 hours per day, 91 days or 2184 hours for this quarter Estimated maximum operation or uptime target (TARGET) Variance (VARIANCE), which is equal to (1–[ACTUAL/TARGET]) TARGET and VARIANCE numbers account for unplanned downtime. Differences in TARGET performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure TARGET for each instrument or datastream. Data availability reported here refers to the average of the individual, continuous datastreams received by the ARM Data Archive. Therefore, data availability is directly related to individual instrument uptime expressed in hours. Data not at the ARM Data Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Missing data caused by scheduled downtime are not included in the metrics. Thus, the average percentage of data in the ARM Data Archive represents the average percentage of the time the instruments were operating for the quarter.

Aerosol↗

Atmospheric Radiation Measurement Climate Research Facility Operations Quarterly Report January 1-March 31, 2017

Individual datastreams from instrumentation at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility fixed and mobile research observatories (sites) are collected and routed to the ARM Data Center (ADC). The Data Management Facility (DMF), a component of the ADC, executes datastream processing in near-real time. Processed data are then delivered approximately daily to the ARM Data Archive, also a component of the ADC, where they are made freely available to the research community. For each instrument, ARM calculates the ratio of the actual number of processed data records received daily at the ARM Data Archive to the expected number of data records. DOE requires national user facilities to report time-based operating data. The requirements involve: Actual hours of operation (ACTUAL)—24 hours per day, 90 days or 2160 hours for this quarter Estimated maximum operation or uptime target (TARGET) Variance (VARIANCE), which is equal to (1–[ACTUAL/TARGET]) TARGET and VARIANCE numbers account for unplanned downtime. Differences in TARGET performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure TARGET for each instrument or datastream. Data availability reported here refers to the average of the individual, continuous datastreams received by the ARM Data Archive. Therefore, data availability is directly related to individual instrument uptime expressed in hours. Data not at the ARM Data Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Missing data caused by scheduled downtime are not included in the metrics. Thus, the average percentage of data in the ARM Data Archive represents the average percentage of the time the instruments were operating for the quarter.

Eastern North Atlantic, Southern Great Plains, Nor↗

Atmospheric Radiation Measurement Climate Research Facility Operations Quarterly Report July 1-September 30, 2016

Individual datastreams from instrumentation at the Atmospheric Radiation Measurement (ARM) Climate Research Facility fixed and mobile research sites are collected and routed to the Data Management Facility (DMF) for processing in near-real time. Instrument and processed data are then delivered approximately daily to the ARM Data Archive, where they are made freely available to the research community. For each instrument, ARM calculates the ratio of the actual number of processed data records received daily at the ARM Data Archive to the expected number of data records. The results are tabulated by 1) individual datastream, site, and month for the current year, and 2) site and fiscal year dating back to 1998. The U.S. Department of Energy requires national user facilities to report time-based operating data. The requirements involve the: Actual hours of operation (ACTUAL) – 24 hours per day, 92 days or 2208 hours for this quarter Estimated maximum operation or uptime target (TARGET) Variance (VARIANCE), which is equal to (1 – [ACTUAL/TARGET]) TARGET and VARIANCE numbers account for unplanned downtime. Differences in TARGET performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure TARGET for each instrument or datastream. Data availability reported here refers to the average of the individual, continuous datastreams received by the ARM Data Archive. Therefore, data availability is directly related to individual instrument uptime expressed in hours. Data not at the ARM Data Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Missing data caused by scheduled downtime are not included in the metrics. Thus, the average percentage of data in the ARM Data Archive represents the average percentage of the time the instruments were operating for the quarter.

Southern Great Plains, North Slope of Alaska, East↗

Atmospheric Radiation Measurement Climate Research Facility Operations Quarterly Report April 1-June 30, 2016

Individual datastreams from instrumentation at the Atmospheric Radiation Measurement (ARM) Climate Research Facility fixed and mobile research sites are collected and routed to the Data Management Facility (DMF) for processing in near-real time. Instrument and processed data are then delivered approximately daily to the ARM Data Archive, where they are made freely available to the research community. For each instrument, ARM calculates the ratio of the actual number of processed data records received daily at the ARM Data Archive to the expected number of data records. The results are tabulated by 1) individual datastream, site, and month for the current year, and 2) site and fiscal year dating back to 1998. The U.S. Department of Energy requires national user facilities to report time-based operating data. The requirements involve the: Actual hours of operation (ACTUAL) – 24 hours per day, 91 days or 2184 hours for this quarter Estimated maximum operation or uptime target (TARGET) Variance (VARIANCE), which is equal to (1 – [ACTUAL/TARGET]) TARGET and VARIANCE numbers account for unplanned downtime. Differences in TARGET performance reflect the complexity of local logistics and the frequency of extreme weather events. It is impractical to measure TARGET for each instrument or datastream. Data availability reported here refers to the average of the individual, continuous datastreams received by the ARM Data Archive. Therefore, data availability is directly related to individual instrument uptime expressed in hours. Data not at the ARM Data Archive are caused by downtime (scheduled or unplanned) of the individual instruments. Missing data caused by scheduled downtime are not included in the metrics. Thus, the average percentage of data in the ARM Data Archive represents the average percentage of the time the instruments were operating for the quarter.

North Slope of Alaska, Eastern North Atlantic, Sou↗

Performing optimized collective operations in an irregular subcommunicator of compute nodes in a parallel computer

In a parallel computer, performing optimized collective operations in an irregular subcommunicator of compute nodes may be carried out by: identifying, within the irregular subcommunicator, regular neighborhoods of compute nodes; selecting, for each neighborhood from the compute nodes of the neighborhood, a local root node; assigning each local root node to a node of a neighborhood-wide tree topology; mapping, for each neighborhood, the compute nodes of the neighborhood to a local tree topology having, at its root, the local root node of the neighborhood; and performing a one way, rooted collective operation within the subcommunicator including: performing, in one phase, the collective operation within each neighborhood; and performing, in another phase, the collective operation amongst the local root nodes.

Davis, Kristan D.↗

Functional and Operating Requirements for the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET)

Microreactors, or small, transportable reactors with a capacity of < 20 MWTH, are sought to provide heat and power for myriad applications in remote areas, military installations, emergency operations, humanitarian missions and disaster relief zones as illustrated in Figure 1. These small, transportable reactor designs, while offering many advantages, are largely untested and unproven. System and component testing is needed to demonstrate to regulators that these designs are safe and to convince customers that the systems are robust, reliable, and efficient. The microreactor agile non-nuclear experimental test bed (MAGNET) is being constructed at Idaho National Laboratory to assist with the development, demonstration, and validation of microreactor components and systems. MAGNET will support technology maturation to reduce uncertainty and risk relative to the operation and deployment of this unique class of systems. Stakeholders for this test bed include microreactor developers, energy users, and regulators. Regulators will be engaged early in the design and testing to expedite regulatory approval and licensing. Within MAGNET, systems and components can be safely tested, providing valuable information on operating regimes, failure modes, and thresholds. Since there are various types of microreactors being proposed, which can be classified according to their core cooling method, heat-pipes, gas-cooled (pebble bed or prismatic), molten salt, light water, or light water, the goal is to provide a test bed that is broadly applicable to multiple microreactor concepts. Each reactor type poses a different set of design and operational challenges and performance claims stated by commercial vendors have not been independently verified through rigorous testing. The initial set of tests to be performed in MAGNET are targeted towards demonstrating the feasibility and performance of heat-pipe cooled reactors, since this concept is unique to very small nuclear reactors. However, the testbed will be constructed to accommodate other designs in addition to heat-pipe cooled reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data-Driven Operator Theoretic Methods for Global Phase Space Learning

In this work, we propose to apply the recently developed Koopman operator techniques to explore the global phase space of a nonlinear system from time-series data. In particular, we address the problem of identifying various invariant subsets of a phase space from the spectral properties of the associated Koopman operator constructed from time-series data. Moreover, in the case when the system evolution is known locally in various invariant subspaces, then a phase space stitching result is proposed that can be applied to identify a global Koopman operator. A biological system, bistable toggle switch and a second-order nonlinear system example are considered to illustrate the proposed results. The construction of this global Koopman operator is very helpful in experimental works as multiple experiments can't be run at the same time starting from several initial conditions.

Nandanoori, Sai Pushpak↗

System and method to characterize and identify operating modes of electric loads

A system characterizes and identifies one of a plurality of different operating modes of a number of electric loads. The system includes a processor; a voltage sensor providing a voltage signal for one of the electric loads to the processor; a current sensor providing a current signal for the one electric load to the processor; and a routine executed by the processor and structured to characterize the different operating modes using steady state and voltage-current trajectory features determined from the voltage and current signals, and to identify a particular one of the different operating modes based on a plurality of operating mode membership functions of the steady state and voltage-current trajectory features.

Yang, Yi↗

Optimal Efficiency and Operational Cost Savings: A Framework for Automated Rooftop PV Placement

Residential energy consumers are charged based on a utility rate structure, such as net metering or feed-in tariff. To lower consumers' electricity bills, expensive batteries are deployed to reduce the electricity fed from the grid during peak hours. However, strategic photovoltaic (PV) panel placement enables the reduction of operational energy cost while considering the spatial feasibility and efficiency for hosting rooftop PV. In this paper, we present a framework to automatically identify the optimal location of rooftop PV panels on residential buildings. Our framework integrates multiple workflows, including energy and environmental simulation, parametric modeling, and optimization to identify the ideal location of PV panels to balance the demand and supply at a building and community scale. These workflows are linked using the Grasshopper plug-in for Rhinoceros CAD software. The framework includes two different workflows, each satisfying a target for optimal PV placement: (a) maximizing PV panel efficiency, where users aim to maximize energy generation, and (b) minimizing operational energy cost, where "best'' panels are selected considering utility rates for operational energy cost. Our framework is demonstrated in a residential community in Fort Collins, Colorado, to generate the optimal PV placement for each of the two aforementioned targets. Results from the two workflows are compared to illustrate the effect of PV location and orientation on solar energy production efficiency and operational energy cost. The developed workflows are introduced as tools within the Grasshopper plug-in to investigate the solar potential of rooftop PV panels while taking into account factors such as contextual shading, utility rate structures, and buildings' energy demand profiles.

30 DIRECT ENERGY CONVERSION↗

Target Control and Protection Systems Lessons from SNS Operations

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory has been in operations since 2006 and proposes a project to build a Second Target Station (STS) to effectively double potential scientific output. The SNS target controls operate in a harsh environment which includes high radiation, exposure to gaseous radionuclides, and activated liquid mercury and mercury vapor. These conditions necessitate protective interlocks and credited controls for protection functions to ensure proper response to off-normal conditions. In order to inform the design of target controls for the STS, we have examined lessons learned during SNS operations regarding the design and implementation of the control and protection systems for the first target station (FTS). This paper will examine various aspects of the performance of the target control and protection systems including reliability, maintainability and sustainability given the challenging environment created by 1.4 MW operations. Specific topics include distributed control of various target subsystems, response to loss of power, selection of nuclear grade instrumentation, and applying these lessons to the design for the STS project.

Humphreys, Dana↗