Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Multiple”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Ozone, NO2 and PM10 are associated with the occurrence of multiple sclerosis relapses. Evidence from seasonal multi-pollutant analyses

Highlights: • Season-dependent associations between short term exposure to NO{sub 2} and O{sub 3} and risk of MS relapses were observed. • Confirmation of PM10-associated risk of MS relapses. • A multi-pollutant approach should be systematically intended, especially when assessing level of PM{sub 10} and NO{sub 2.} • Individual characteristics should be considered alongside other MS relapses risk factors. Triggers of multiple sclerosis (MS) relapses are essentially unknown. PM{sub 10} exposure has recently been associated with an increased risk of relapses.

54 ENVIRONMENTAL SCIENCES↗

Long-term exposure to air pollution and the incidence of multiple sclerosis: A population-based cohort study

Highlights: • No associations of MS incidence with PM{sub 2.5} and NO{sub 2} were observed. • There was a tendency for increasing MS incidence in relation to O{sub 3.} • Females exhibited a higher risk of developing MS in association with O{sub 3} than males. Evidence of the adverse neurological effects of exposure to ambient air pollution is emerging, but little is known about its effect on the development of multiple sclerosis (MS), the most common autoimmune disease of the central nervous system.

54 ENVIRONMENTAL SCIENCES↗

Joint estimation of biogeochemical model parameters from multiple experiments: A bayesian approach applied to mercury methylation

Here, to characterize complex biogeochemical systems, results from multiple experiments, where each targets a specific subprocess, are commonly combined. The resulting datasets are interpreted through the calibration of biogeochemical models for process inference and predictions. Commonly used calibration approaches of fitting datasets from individual experiments to subprocess models one at a time is prone to missing information shared between datasets and incomplete uncertainty propagation. We propose a Bayesian joint-fitting scheme addressing the above-mentioned concerns by jointly fitting all the available datasets, thus calibrating the entire biogeochemical model in one go using Markov Chain Monte Carlo (MCMC). The identification of null spaces in the parameter distributions from MCMC guided the simplification of certain subprocess models. For example, fast kinetic sorption was replaced by equilibrium sorption, and Monod demethylation was replaced by first-order demethylation. Joint fitting of datasets resulted in complete uncertainty propagation with parameter estimates informed by all available data.

54 ENVIRONMENTAL SCIENCES↗

High-Yield Secretion of Multiple Client Proteins in Aspergillus

Production of pure and high-yield client proteins is an important technology that addresses the need for industrial applications of enzymes as well as scientific experiments in protein chemistry and crystallization. Fungi are utilized in industrial protein production because of their ability to secrete large quantities of proteins. In this study, we engineered a high-expression-secretion vector, pEXPYR that directs proteins towards the extracellular medium in two Aspergillii host strains, examine the effect of maltose-induced over-expression and protein secretion as well as time and pH-dependent protein stability in the medium. We describe five client proteins representing a core set of hemicellulose degrading enzymes that accumulated up to 50-100 mg/L of protein. Using a recyclable genetic marker that allows serial insertion of multiple genes, simultaneous hyper-secretion of three client proteins in a single host strain was accomplished.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental and numerical studies of helium-cooled modular divertors with multiple jets

As part of the US-Japan PHENIX program, the helium-cooled modular divertor with multiple jets (HEMJ) and a simpler “flat” variant were experimentally studied in a closed helium loop with a redesigned test chamber at coolant inlet temperatures as great as 425 °C, incident heat fluxes as great as 2.2 MW/m 2 and prototypical inlet pressures of ~10 MPa. The data were used to develop correlations for the average Nusselt number and loss coefficient for a range of mass flow rates; these correlations were used in turn to predict the thermal-hydraulic performance of a single divertor module at prototypical conditions. The experimental results suggest that a flat jet array with six holes surrounding one central hole, all of the same diameter, can provide similar average heat transfer coefficients as the HEMJ divertor, albeit with higher pumping power requirements. Because of its smaller cooled surface area, however, this design has lower maximum allowable heat fluxes compared with the HEMJ divertor. Nevertheless, the flat variant could potentially simplify manufacturing and reduce the costs required to fabricate O(10 6 ) “finger” modules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

QoS-aware edge AI placement and scheduling with multiple implementations in FaaS-based edge computing

Resource constraints on the computing continuum require that we make smart decisions for serving AI-based services at the network edge. AI-based services typically have multiple implementations (e.g., image classification implementations include SqueezeNet, DenseNet, and others) with varying trade-offs (e.g., latency and accuracy). The question then is how should AI-based services be placed across Function-as-a-Service (FaaS) based edge computing systems in order to maximize total Quality-of-Service (QoS). To address this question, we propose a problem that jointly aims to solve (i) edge AI service placement and (ii) request scheduling. These are done across two time-scales (one for placement and one for scheduling). Here we first cast the problem as an integer linear program. We then decompose the problem into separate placement and scheduling subproblems and prove that both are NP-hard. We then propose a novel placement algorithm that places services while considering device-to-device communication across edge clouds to offload requests to one another. Our results show that the proposed placement algorithm is able to outperform a state-of-the-art placement algorithm for AI-based services, and other baseline heuristics, with regard to maximizing total QoS. Additionally, we present a federated learning-based framework, FLIES, to predict the future incoming service requests and their QoS requirements. Our results also show that our FLIES algorithm is able to outperform a standard decentralized learning baseline for predicting incoming requests and show comparable predictive performance when compared to centralized training.

97 MATHEMATICS AND COMPUTING↗

Calibrating Synchronous-Generator-Interfaced DG Models in Microgrids Using Multiple Event Data

Microgrids, consisting of distributed generators (DGs), loads, and energy storage systems, play an important role in future smart grids. In order to evaluate how microgrids operate and their dynamic response, it is necessary to develop accurate dynamic models of DGs in microgrids. This paper proposes a systematic method to calibrate synchronous-generator-interfaced DG models. Challenges associated with model validation in microgrids are analyzed. Underlying parameters are categorized into two groups, i.e., the steady-state parameters and time constants, which are estimated in two successive stages using multiple event data. This methodology ensures that the validated model with the estimated parameters are applicable for all events. A modified unscented Kalman filter (UKF) is proposed to deal with the cases in which measurement of power angle is unavailable. The effectiveness of the proposed method is validated using field test data of a 2.6 MVA diesel generator in a real microgrid.

Wang, Zhiwen↗

Combining multiple lower-fidelity models for emulating complex model responses for CCS environmental risk assessment

Numerical modeling is essential to support natural resource management and environmental policy-making. In the context of CO 2 geological sequestration, these models are indispensible parts of risk assessment tools. However, because of increasing complexity, modern numerical models require a great computational effort, which in some cases may be infeasible. An increasingly popular approach to overcome computational limitations is the use of surrogate models. This paper presents a new surrogate modeling approach to reduce the computational cost of running a complex, high-fidelity model. The approach is based on the simplification the high-fidelity model into computationally efficient, lower-fidelity models and on linking them with a mathematical function (linking function) that addresses the discrepancies between outputs from models with different levels of fidelity. The resulting linking function model, which can be developed with small computational effort, can be efficiently used in numerical applications where multiple runs of the original high-fidelity model are required, such as for uncertainty quantification or sensitivity analysis. The proposed approach was then applied to the development of a reduced order model for the prediction of groundwater quality impacts from CO 2 and brine leakage for the National Risk Assessment Partnership (NRAP) project.

54 ENVIRONMENTAL SCIENCES↗

Dose Distribution Analysis in Stereotactic Body Radiotherapy Using Dynamic Conformal Multiple Arc Therapy

Purpose: We have used dynamic conformal multiple arc therapy (DCMAT) for stereotactic body radiotherapy (SBRT) since 2001. We investigated the consistency of DCMAT for SBRT using dose-volume histogram analysis. Methods and Materials: A total of 50 patients with peripheral lung tumors underwent SBRT. The median tumor diameter was 2.4 cm (range, 0.9-5.9). Treatment planning was performed using a superposition algorithm. The prescribed 50 Gy dose was divided into five fractions. The prescribed dose was defined as 80% of the maximal dose in the planning target volume (PTV), and the leaf margins were modified to ensure the PTV was included in the 80% isodose surface. The dose-volume histogram analysis was used to assess the PTV and normal lung volume. Results: The median dose covering 95% of the PTV was 50.27 Gy (range, 46.14-52.67), essentially consistent with the prescribed dose. The median homogeneity and conformity index was 1.41 (range, 1.31-1.53) and 1.73 (range, 1.41-2.21), respectively. The median volume of lung receiving {>=}20 Gy (V{sub 20}) was 4.2% (range, 1.4-10.2%). A linear correlation was found between the tumor diameter and V{sub 20}, and an even stronger correlation was found between the PTV/(normal lung volume) and V{sub 20}. The estimated V{sub 20} was 7.1% (range, 3.9-10.4%) for a 5-cm-diameter tumor, assumed to be the maximal size limitation for SBRT. Conclusion: SBRT with DCMAT achieved high conformity and delivered adequate doses within the PTV. The median dose covering 95% of the PTV was consistent with the prescribed dose. V{sub 20} can be estimated using the tumor diameter and normal lung volume. DCMAT was thus both a feasible and a reproducible method of SBRT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous Multitarget Irradiation Using Helical Tomotherapy for Advanced Hepatocellular Carcinoma With Multiple Extrahepatic Metastases

Purpose: The prognosis of hepatocellular carcinoma (HCC) patients with extrahepatic metastases is extremely poor. Helical tomotherapy, an image-guided, intensity-modulated radiotherapy system, can allow for simultaneous and precise targeting of multiple cancerous lesions, while sparing normal tissues. This study evaluated the feasibility and outcome of tomotherapy for advanced HCC with metastases. Patients and Methods: A total of 42 consecutive HCC patients with metastases were treated with tomotherapy using the Hi-Art system. A total of 152 intra- and extrahepatic lesions (3.5 lesions/patient) were treated simultaneously, with a dose of 51.03 Gy (range, 30-57.61) in 10 fractions. Transarterial chemolipiodolization using epirubicin (50 mg) and cisplatin (60 mg) was repeated in patients with intrahepatic HCC (mean size, 9.0 cm) after tomotherapy. Results: An objective response (complete response and partial response) was achieved in 45.2% of patients with intrahepatic tumors, 68.4% of patients with pulmonary lesions, 60.0% of patients with lymph node/adrenal lesions, and 66.7% of patients with soft-tissue metastases. The complete response rate for those with pulmonary and lymph node/adrenal metastases was 26.3% and 5.0%, respectively. The overall survival rate at 1 and 2 years was 50.1% and 14.9%, respectively, with a median survival of 12.3 months. The actuarial in-field tumor control rate for {<=}1 year was 79.0%. No cases of Grade 4-5 acute toxicity occurred. Conclusion: The results of this study have shown that helical tomotherapy is safe and feasible without major toxicities for the treatment of advanced HCC and results in excellent tumor control and a potential survival benefit. This approach is expected to be a useful palliative option for selected HCC patients with metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing Radiation Treatments Using Intensity-Modulated Beams, Multiple Arcs, and Single Arcs

Purpose: A dosimetric comparison of multiple static-field intensity-modulated radiation therapy (IMRT), multiarc intensity-modulated arc therapy (IMAT), and single-arc arc-modulated radiation therapy (AMRT) was performed to evaluate their clinical advantages and shortcomings. Methods and Materials: Twelve cases were selected for this study, including three head-and-neck, three brain, three lung, and three prostate cases. An IMRT, IMAT, and AMRT plan was generated for each of the cases, with clinically relevant planning constraints. For a fair comparison, the same parameters were used for the IMRT, IMAT, and AMRT planning for each patient. Results: Multiarc IMAT provided the best plan quality, while single-arc AMRT achieved dose distributions comparable to those of IMRT, especially in the complicated head-and-neck and brain cases. Both AMRT and IMAT showed effective normal tissue sparing without compromising target coverage and delivered a lower total dose to the surrounding normal tissues in some cases. Conclusions: IMAT provides the most uniform and conformal dose distributions, especially for the cases with large and complex targets, but with a delivery time similar to that of IMRT; whereas AMRT achieves results comparable to IMRT with significantly faster treatment delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toxicity of Gamma Knife Radiosurgery in the Treatment of Intracranial Tumors in Patients With Collagen Vascular Diseases or Multiple Sclerosis

Purpose: To assess toxicity in patients with either a collagen vascular disease (CVD) or multiple sclerosis (MS) treated with intracranial radiosurgery. Methods and Materials: Between January 2004 and April 2009, 6 patients with MS and 14 patients with a CVD were treated with Gamma Knife radiosurgery (GKRS) for intracranial tumors. Treated lesions included 15 total brain metastases in 7 patients, 11 benign brain tumors, 1 low grade glioma, and 1 cavernous malformation. Toxicities were graded by the Radiation Therapy Oncology Group Acute/Late Radiation Morbidity Scoring Criteria. 'Rare toxicities' were characterized as those reported in the scientific literature at an incidence of <5%. Results: Median follow-up time was 16 months. Median dose to the tumor margin was 13.0 Gy (range, 12-21 Gy). Median size of tumor was 5.0 cm{sup 3} (range, 0.14-7.8 cm{sup 3}). Of the 14 patients with CVD, none experienced a Grade 3 or 4 toxicity or a toxicity characterized as rare. Of the 6 patients with MS, 3 experienced rare toxicities, and two of these were Grade 3 toxicities. Rare complications included a patient experiencing both communicating hydrocephalus and facial nerve palsy, as well as 2 additional patients with motor cranial nerve palsy. High-grade toxicities included the patient with an acoustic neuroma requiring ventriculoperitoneal shunt placement for obstructive hydrocephalus, and 1 patient with a facial nerve schwannoma who experienced permanent facial nerve palsy. Interval between radiosurgery and high-grade toxicities ranged from 1 week to 4 months. Conclusions: Our series suggests that patients with MS who receive GKRS may be at increased risk of rare and high-grade treatment-related toxicity. Given the time course of toxicity, treatment-related edema or demyelination represent potential mechanisms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of IGRT Registration Strategies for Optimal Coverage of Primary Lung Tumors and Involved Nodes Based on Multiple Four-Dimensional CT Scans Obtained Throughout the Radiotherapy Course

Purpose: To investigate the impact of primary tumor and involved lymph node (LN) geometry (centroid, shape, volume) on internal target volume (ITV) throughout treatment for locally advanced non-small cell lung cancer using weekly four-dimensional computed tomography (4DCT). Methods and Materials: Eleven patients with advanced non-small cell lung cancer were treated using image-guided radiotherapy with acquisition of weekly 10-Phase 4DCTs (n = 51). Initial ITV was based on planning 4DCT. Master-ITV incorporated target geometry across the entire treatment (all 4DCTs). Geographic miss was defined as the % Master-ITV positioned outside of the initial planning ITV after registration is complete. Registration strategies considered were bony (B), primary tumor soft tissue alone (T), and registration based on primary tumor and involved LNs (T{sub L}N). Results: The % geographic miss for the primary tumor, mediastinal, and hilar lymph nodes based on each registration strategy were (1) B: 30%, 30%, 30%; (2) T: 21%, 40%, 36%; and (3) T{sub L}N: 26%, 26%, 27%. Mean geographic expansions to encompass 100% of the primary tumor and involved LNs were 1.2 {+-} 0.7 cm and 0.8 {+-} 0.3 cm, respectively, for B and T{sub L}N. Primary and involved LN expansions were 0.7 {+-} 0.5 cm and 1.1 {+-} 0.5 cm for T. Conclusion: T is best for solitary targets. When treatments include primary tumor and LNs, B and T{sub L}N provide more comprehensive geographic coverage. We have identified high % geographic miss when considering multiple registration strategies. The dosimetric implications are the subject of future study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Day-to-Day Reproducibility of Prostate Intrafraction Motion Assessed by Multiple kV and MV Imaging of Implanted Markers During Treatment

Purpose: When one is performing online setup correction for prostate positioning displacements prior to daily dose delivery, intrafraction motion can become a limiting factor to prostate targeting accuracy. The aim of this study was to quantify and characterize prostate intrafraction motion assessed by multiple kilovoltage (kV) and megavoltage (MV) imaging of implanted markers during treatment in a large patient group. Methods and Materials: Intrafraction motion in the sagittal plane was studied by retrospective analysis of displacements of implanted gold markers on (nearly) lateral kV and MV images obtained at various time points during the treatment fractions (mean, 27 per patient) in 108 consecutive patients. The effective prostate motion in a fraction was defined as the time-weighted mean displacement. Results: Prostate displacements in the sagittal plane increased during the fraction (mean, 0.2 {+-} 0.2 mm/min). Forty percent of patients had a systematic (i.e., appearing in all fractions) effective displacement in the sagittal plane greater than 2 mm. Observed effective population mean-of-means ({mu}eff) +/- systematic ({Sigma}eff) intrafraction motion ({mu}{sub eff} {+-} {Sigma}{sub eff}) was 0.9 {+-} 1.1 mm and 0.6 {+-} 1.0 mm for the anterior-posterior and superior inferior directions, respectively. Corresponding random motion ({sigma}{sub eff}) was 1.2 mm and 1.1 mm. Mean effective prostate motion in the first 5 fractions was predictive for mean effective displacement in the remaining fractions (p < 0.001). Conclusion: For a large subgroup of patients, the systematic component of intrafraction prostate motion was substantial. Intrafraction motion correction prior to each beam delivery or offline corrections could likely be beneficial for the subgroup of patients with significant motion. The systematic component is well predicted by measurements in the initial fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase I Study of Short-Course Accelerated Whole Brain Radiation Therapy for Multiple Brain Metastases

Purpose: To define the maximum tolerated dose (MTD) of a SHort-course Accelerated whole brain RadiatiON therapy (SHARON) in the treatment of patients with multiple brain metastases. Methods and Materials: A phase 1 trial in 4 dose-escalation steps was designed: 12 Gy (3 Gy per fraction), 14 Gy (3.5 Gy per fraction), 16 Gy (4 Gy per fraction), and 18 Gy (4.5 Gy per fraction). Eligibility criteria included patients with unfavorable recursive partitioning analysis (RPA) class > or =2 with at least 3 brain metastases or metastatic disease in more than 3 organ systems, and Eastern Cooperative Oncology Group (ECOG) performance status {<=}3. Treatment was delivered in 2 days with twice-daily fractionation. Patients were treated in cohorts of 6-12 to define the MTD. The dose-limiting toxicity (DLT) was defined as any acute toxicity {>=}grade 3, according to the Radiation Therapy Oncology Group scale. Information on the status of the main neurologic symptoms and quality of life were recorded. Results: Characteristics of the 49 enrolled patients were as follows: male/female, 30/19; median age, 66 years (range, 23-83 years). ECOG performance status was <3 in 46 patients (94%). Fourteen patients (29%) were considered to be in recursive partitioning analysis (RPA) class 3. Grade 1-2 acute neurologic (26.4%) and skin (18.3%) toxicities were recorded. Only 1 patient experienced DLT (neurologic grade 3 acute toxicity). With a median follow-up time of 5 months (range, 1-23 months), no late toxicities have been observed. Three weeks after treatment, 16 of 21 symptomatic patients showed an improvement or resolution of presenting symptoms (overall symptom response rate, 76.2%; confidence interval 0.95: 60.3-95.9%). Conclusions: Short-course accelerated radiation therapy in twice-daily fractions for 2 consecutive days is tolerated up to a total dose of 18 Gy. A phase 2 study has been planned to evaluate the efficacy on overall survival, symptom control, and quality of life indices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling Freedom From Progression for Standard-Risk Medulloblastoma: A Mathematical Tumor Control Model With Multiple Modes of Failure

Purpose: As pediatric medulloblastoma (MB) is a relatively rare disease, it is important to extract the maximum information from trials and cohort studies. Here, a framework was developed for modeling tumor control with multiple modes of failure and time-to-progression for standard-risk MB, using published pattern of failure data. Methods and Materials: Outcome data for standard-risk MB published after 1990 with pattern of relapse information were used to fit a tumor control dose-response model addressing failures in both the high-dose boost volume and the elective craniospinal volume. Estimates of 5-year event-free survival from 2 large randomized MB trials were used to model the time-to-progression distribution. Uncertainty in freedom from progression (FFP) was estimated by Monte Carlo sampling over the statistical uncertainty in input data. Results: The estimated 5-year FFP (95% confidence intervals [CI]) for craniospinal doses of 15, 18, 24, and 36 Gy while maintaining 54 Gy to the posterior fossa was 77% (95% CI, 70%-81%), 78% (95% CI, 73%-81%), 79% (95% CI, 76%-82%), and 80% (95% CI, 77%-84%) respectively. The uncertainty in FFP was considerably larger for craniospinal doses below 18 Gy, reflecting the lack of data in the lower dose range. Conclusions: Estimates of tumor control and time-to-progression for standard-risk MB provides a data-driven setting for hypothesis generation or power calculations for prospective trials, taking the uncertainties into account. The presented methods can also be applied to incorporate further risk-stratification for example based on molecular biomarkers, when the necessary data become available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Grade Glioma Radiation Therapy Target Volumes and Patterns of Failure Obtained From Magnetic Resonance Imaging and {sup 18}F-FDOPA Positron Emission Tomography Delineations From Multiple Observers

Purpose: The objective of this study was to compare recurrent tumor locations after radiation therapy with pretreatment delineations of high-grade gliomas from magnetic resonance imaging (MRI) and 3,4-dihydroxy-6-[{sup 18}F]fluoro-L-phenylalanine ({sup 18}F-FDOPA) positron emission tomography (PET) using contours delineated by multiple observers. Methods and Materials: Nineteen patients with newly diagnosed high-grade gliomas underwent computed tomography (CT), gadolinium contrast-enhanced MRI, and {sup 18}F-FDOPA PET/CT. The image sets (CT, MRI, and PET/CT) were registered, and 5 observers contoured gross tumor volumes (GTVs) using MRI and PET. Consensus contours were obtained by simultaneous truth and performance level estimation (STAPLE). Interobserver variability was quantified by the percentage of volume overlap. Recurrent tumor locations after radiation therapy were contoured by each observer using CT or MRI. Consensus recurrence contours were obtained with STAPLE. Results: The mean interobserver volume overlap for PET GTVs (42% ± 22%) and MRI GTVs (41% ± 22%) was not significantly different (P=.67). The mean consensus volume was significantly larger for PET GTVs (58.6 ± 52.4 cm{sup 3}) than for MRI GTVs (30.8 ± 26.0 cm{sup 3}, P=.003). More than 95% of the consensus recurrence volume was within the 95% isodose surface for 11 of 12 (92%) cases with recurrent tumor imaging. Ten (91%) of these cases extended beyond the PET GTV, and 9 (82%) were contained within a 2-cm margin on the MRI GTV. One recurrence (8%) was located outside the 95% isodose surface. Conclusions: High-grade glioma contours obtained with {sup 18}F-FDOPA PET had similar interobserver agreement to volumes obtained with MRI. Although PET-based consensus target volumes were larger than MRI-based volumes, treatment planning using PET-based volumes may not have yielded better treatment outcomes, given that all but 1 recurrence extended beyond the PET GTV and most were contained by a 2-cm margin on the MRI GTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Single- versus Multiple-Fraction Palliative Radiation Therapy for Bone Metastases: Population-Based Analysis of 16,898 Courses in a Canadian Province

Purpose: There is abundant evidence that a single fraction (SF) of palliative radiation therapy (RT) for bone metastases is equivalent to more protracted and costly multiple fraction courses. Despite this, there is low utilization of SFRT internationally. We sought to determine the utilization of SFRT in a population-based, publicly funded health care system. Methods and Materials: All consecutive patients with bone metastases treated with RT during 2007 to 2011 in British Columbia (BC) were identified. Associations between utilization of SFRT and patient and provider characteristics were investigated. Results: A total of 16,898 courses of RT were delivered to 8601 patients. SFRT was prescribed 49% of the time. There were positive relationships among SFRT utilization and primary tumor group (P<.001; most commonly in prostate cancer), worse prognosis (P<.001), increasing physician experience (P<.001), site of metastases (P<.001; least for spine metastases), and area of training (P<.001; most commonly for oncologists trained in the United Kingdom). There was wide variation in the prescription of SFRT across 5 regional cancer centers, ranging from 25.5% to 73.4%, which persisted after controlling for other, potentially confounding factors (P<.001). Conclusions: The large variability in SFRT utilization across BC Cancer Agency (BCCA) cancer centers suggests there is a strong cultural effect, where physicians' use of SFRT is influenced by their colleagues' practice. SFRT use in BC was similar to that in other Canadian and western European reports but strikingly higher than in the United States. Further work is needed to standardize SFRT prescribing practices internationally for this common indication for RT, with the potential for huge health system cost savings and substantial improvements in patients' quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗