Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

An innovative digital image correlation technique for in-situ process monitoring of composite structures in large scale additive manufacturing

As additive manufacturing (AM) continues to develop and become a standardized manufacturing method, there will be a continued need to provide in-situ monitoring during the manufacturing of polymer composite printed components. Thermal residual stress is a primary cause of failures such as interlayer disbonds or delamination, micro cracking, and dimensional instability, which can occur during or after the build. Here, we report a novel digital image correlation (DIC) adaptation to monitor thermal residual stresses during the entire print process for large-scale AM. In this work, DIC has been investigated (a) by the natural speckle produced by the polymer surface for correlation, (b) to monitor AM build, and (c) to evaluate the effect of thermal residual stress on warpage of the printed component. The natural speckle pattern of the AM material resulted in a respectable 3.57% error compared to the traditional painted speckle pattern of 3.05% error. DIC measured a 190% increase in vertical displacement at the edge of the wall compared to the center, indicating warpage during AM. This work is a step towards a non-intrusive residual stress measuring technique using DIC for large-scale AM.

36 MATERIALS SCIENCE↗

Battery state of health monitoring by estimation of the number of cyclable Li-ions

Herein this paper introduces a method to monitor battery state of health (SOH) by estimating the number of cyclable Li-ions, a health-relevant electrochemical variable. SOH monitoring is critical to battery management in balancing the trade-off between maximizing system performance and minimizing battery degradation. The decrease of cyclable Li-ions indicates the effect on the SOH of degradation mechanisms that consume cyclable Li-ions. The unavailability of the number of cyclable Li-ions through non-invasive measurements makes its estimation necessary for in-situ SOH monitoring. In this paper, the extended Kalman filter (EKF) is used to estimate the number of cyclable Li-ions as an unknown battery parameter. The single particle model (SPM), a simplified battery electrochemical model, is used as the model in the EKF to achieve a computational complexity suitable for on-line estimation. Simulations are performed under typical electric vehicle current trajectories using an example parameter set for a hybrid-electric-vehicle battery. In the simulations, the battery is represented by the Doyle–Fuller–Newman (DFN) model, an electrochemical model with higher fidelity than the SPM. To comply with the practice, instead of using the same parameters as the DFN model in the SPM, parameterization of the SPM is performed before estimation of the number of cyclable Li-ions. The simulations show high estimation accuracy of the number of cyclable Li-ions using the EKF, even with the structural and parametric differences between the DFN model and the SPM, under both the ideal conditions and various non-ideal conditions (i.e., SOC estimation error, additional modeling error, and measurement noise).

25 ENERGY STORAGE↗

Monitoring river flow status using low-cost wildlife camera and image segmentation artificial intelligence

Continuous measurement and monitoring of surface water coverage in non-perennial streams are essential for understanding the exchange fluxes between surface and subsurface waters under both inundated and non-inundated conditions. In this study, a wildlife camera photo-based framework was developed to monitor small stream water inundation, depth, discharge, and velocity. Two advanced machine learning models, YOLOv8 and Mask2Former, were utilized to efficiently analyze images captured by wildlife cameras. The accuracy of the framework was validated against on-site depth measurements at six sites in the Yakima River Basin, along with the gage height, discharge, and velocity data from four USGS sites. This approach facilitates long-term, continuous monitoring and quantification of river intermittency and water availability with high precision and low cost, thereby advancing river ecosystem research and management.

machine learning↗

Improved geophysical monitoring of carbon sequestration through parameter linkage to reservoir modeling

Predictive reservoir modeling, even if present in the form of only basic hydrogeological model assumptions, is expected to accompany the majority of carbon capture and sequestration monitoring activities. It thus represents a source of prior information about the migration of injected fluids that can benefit geophysical survey planning and ensuing monitoring. Constraining the imaging of geophysical monitoring data with reservoir modeling is preferable over standalone geophysical imaging because of additional complementary hydrogeological information. However, fully coupled hydrogeophysical data inversion for flow-modeling parameters that control saturation predictions is an involved process. Within the context of three-dimensional electromagnetic (EM) inversion of data from borehole-to-surface layouts, we employ a "poor people's" alternative. The approach constrains geophysical inversion parameters through saturation predictions. The coupling is realized through spatially variable lower and upper parameter bounds that scale with gas saturation magnitudes, the latter provided by reservoir modeling. In this work, enhancement of three-dimensional time-lapse plume EM imaging is demonstrated for simulated sequestration into a depleted gas reservoir.

58 GEOSCIENCES↗

Elastic-wave sensitivity-guided adaptive seismic survey design for cost-effective monitoring of geological carbon storage

Effective seismic monitoring is essential for verifying CO₂ containment, detecting potential leakage, and optimizing operational decisions in geologic carbon storage. Here, this study presents a time-adaptive, elastic-wave sensitivity-guided framework for designing cost-effective seismic monitoring layouts for tracking CO₂ plume migration. The method is based on elastic-wave sensitivity analysis, which quantifies how variations in subsurface properties impact seismic wavefields. Two complementary design strategies are developed: one based on selecting a fixed number of seismic sources (Method A), and the other based on selecting source–receiver pairs contributing to a fixed fraction of cumulative elastic-wave sensitivity energy (Method B). The optimization workflow to identify source–receiver configurations with the highest detection potential is demonstrated using a hypothetical GCS scenario at the Kimberlina site in California using simulations of elastic-wave sensitivity data at multiple post-injection timesteps. Results show that both strategies adapt to evolving plume geometries and wavefield sensitivities, with Method B offering broader spatial coverage and Method A ensuring simpler deployment. This framework enables site-specific, cost-effective, and risk-informed seismic survey designs, enhancing the ability to monitor CO₂ migration over time in evolving geological environments

58 GEOSCIENCES↗

In-situ curvature monitoring and X-ray diffraction study of InGaAsP/InGaP quantum wells

The use of InGaAsP/InGaP quantum well structures is a promising approach for subcells in next generation multi-junction devices due to their tunable bandgap (1.50-1.80 eV) and for being aluminum-free. Despite these potentials, the accumulation of stress during the growth of these structures and high background doping in the quantum well region have previously limited the maximum number of quantum wells and barriers that can be included in the intrinsic region and the sub-bandgap external quantum efficiency to less than 30.0%. In this paper, we report on the use of in-situ curvature monitoring by multi-beam optical stress (MOS) sensor measurements during the growth of this quantum well structure to monitor the stress evolution in these thin films. A series of In 0.32 Ga 0.68 AsP/In 0.49 Ga 0.51 P quantum wells with various arsine to phosphine ratios have been analyzed by in-situ curvature monitoring and X-ray diffraction (XRD) to obtain nearly strain-free lattice matched structures. Sharp interfaces, as indicated by the XRD fringes, have been achieved by using triethyl-gallium and trimethyl-gallium as gallium precursors in InGaAsP and InGaP, respectively, with constant flows of trimethyl-indium and phosphine through the entire quantum well structure. The effect of the substrate miscut on quantum well growth was compared and analyzed using XRD, photoluminescence and time resolved photoluminescence. As a result, a 100 period quantum well device was successfully grown with minimal stress and approximately flat in-situ curvature.

14 SOLAR ENERGY↗

A composite position independent monitor of reactor fuel irradiation using Pu, Cs, and Ba isotope ratios

When post-irradiation materials from the nuclear fuel cycle are released to the environment, certain isotopes of actinides and fission products carry signatures of irradiation history that can potentially aid a nuclear forensic investigation into the material's provenance. In this study, combinations of Pu, Cs, and Ba isotope ratios that produce position (in the reactor core) independent monitors of irradiation history in spent light water reactor fuel are identified and explored. These position independent monitors (PIMs) are modeled for various irradiation scenarios using automated depletion codes as well as ordinary differential equation solutions to approximate nuclear physics models. Experimental validation was performed using irradiated low enriched uranium oxide fuel from a light water reactor, which was sampled at 8 axial positions from a single rod. Plutonium, barium and cesium were chemically separated and isotope ratio measurements of the separated solutions were made by quadrupole and multi-collector inductively coupled mass spectrometry (Cs and Pu, respectively) and thermal ionization mass spectrometry (Ba). The effect of axial variations in neutron fluence and energy spectrum are evident in the measured isotope ratios. Furthermore, two versions of a combined Pu and Cs based PIM are developed. A linear PIM model, which can be used to solve for irradiation time is found to work well for natural U fuel with <10% 240 Pu and known or short cooling times. A non-linear PIM model, which cannot be solved explicitly for irradiation time without additional information, can nonetheless still group samples by irradiation history, including high burnup LEU fuel with unknown cooling time. 137 Ba/ 138 Ba is also observed to act as a position independent monitor; it is nearly single valued across the sampled fuel rod, indicating that samples sharing an irradiation history (same irradiation time and cooling time) in a reactor despite experiencing different neutron fluxes will have a common 137 Ba/ 138 Ba ratio. Modeling of this Ba PIM shows it increases monotonically with irradiation and cooling time, and a confirmatory first order analytical solution is also presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Projected network performance for multiple isotopes using next-generation xenon monitoring systems

Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski et al., 2014) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. In conclusion, signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Projected network performance for next-generation xenon monitoring systems

Next-generation radioxenon monitoring systems are reaching maturity and are expected to improve certain aspects of performance in verifying the absence of nuclear tests. To predict the improvement in detecting and locating nuclear releases, thousands of releases all over the globe were simulated and the global detection probability was calculated. This was done for the International Monitoring System network of noble gas samplers as it currently exists (25 certified stations), and how it would be for potential future network sizes of 39 and 79 stations. The probability of detection was calculated for releases ranging from 10 10 Bq to 10 16 Bq of 133 Xe and presented as coverage maps and global integrals for both current and next-generation monitoring systems. Similarly, the number of detecting stations and the number of detecting samples were tabulated to elucidate the possibilities for enhanced location capability. Improvements in global detection coverage are maximized at different release sizes in a way that depends on the station density. For example, for releases of 3×10 14 Bq and 39 stations, the detection probability would rise from 60% to 70% with next-generation systems, while for releases of 10 13 Bq and 79 stations, it would rise from 37% to 52%. Achieving an average of two detecting stations requires a 1015 Bq release for a 39-station network and a 10 14 Bq release for a 79-station network. The largest impact of using next-generation systems may be the confidence, failure tolerance, and location capability that arise from obtaining multiple samples associated with a single release event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and testing of a continuous maritime monitor for radionuclide aerosols

Monitoring airborne concentrations of radionuclide activity may provide a timely warning to sea-based assets to avoid contamination from a radioactive plume. The development and testing of an automated aerosol monitoring system that can capture and detect radioactive particulate from marine air is presented. A custom electrostatic precipitator (ESP) was designed to capture particulate onto a reusable collection media. The collection efficiency of the ESP system for radon progeny was determined to be ~23%. A conservative calculation of the minimum detectable concentration of 214 Bi was estimated as 0.3-8 Bq/m 3 . The system was demonstrated in continuous operation, without consumables and limited maintenance, in a marine environment at the PNNL campus in Sequim, Washington. In conclusion, a successful 2-month deployment indicates the feasibility of the approach for continuous maritime monitoring for radionuclide aerosols.

Moore, Michael E. [Pacific Northwest National Labo↗

Multi phenomena melt pool sensor data fusion for enhanced process monitoring of laser powder bed fusion additive manufacturing

Finding actionable trends in laser-based metal additive manufacturing process monitoring data is challenging owing to the diversity and complexity of the underlying physical interactions. A single monitoring solution that captures a particular process phenomenon, such as a photodiode that tracks melt pool intensity, is not alone capable of evaluating process stability or detecting flaw formation with sufficient precision for routine application in industry. In this work, to improve flaw detection performance, we adopted a data fusion approach that captures multiple process phenomena. To demonstrate this, we acquired data from laser powder bed fusion (LPBF) builds of cylindrical specimens produced with different laser spot sizes, emulating defocusing due to process faults such as thermal lensing. The resulting specimens had porosity of varying types and severity, quantified by post-build non-destructive X-ray computed tomography, Archimedes density measurements, and destructive metallographic characterization. During the build, the melt pool state was monitored with two coaxial high-speed video cameras and a temperature field imaging system. Physically intuitive low-level melt pool signatures, such as melt pool temperature, shape and size, and spatter intensity were extracted from this high-dimensional, image-based sensor data. These process signatures were subsequently used as input features in relatively simple machine learning models, such as a support vector machine, which were trained to detect laser defocusing, and in addition, predict porosity type and severity. The results show that the data fusion approach significantly enhanced system performance by reducing the overall false positive rate from ~ 0.1 to ~ 0.001 without sacrificing the true positive rate (~0.90). These results were at par with a black-box, deep machine learning approach (convolutional neural network).

36 MATERIALS SCIENCE↗

Acoustic emission monitoring of crack propagation in additively manufactured and conventional titanium components

We report that additive manufacturing (AM) is a novel and innovative production technology that can produce complex and lightweight engineering products. In AM components, as in all engineering materials, fatigue is considered as one of the principle causes of unexpected failure. In order to detect, localise and characterise cracks in various material components and metals, acoustic emission (AE) is used as a non-destructive monitoring technique. One of the main advantages of AE is that it can be also used for dynamic damage characterisation and specifically for crack propagation monitoring. In this research, we use AE to monitor the fatigue crack growth behaviour of Ti6Al4V components under four-point bending. The samples were produced by means of AM as well as conventional material. Notched and unnotched specimens were investigated with respect to the crack severity and crack detection using AE. The main AE signal parameters –such as cumulative events, hits, duration, average frequency and rise time– were evaluated and indicate sensitivity to damage propagation in order to lead to a warning against the final fracture occurrence. Finally, this is the first time that AE is applied in AM components under fatigue.

36 MATERIALS SCIENCE↗

Development of an advanced antineutrino detector for reactor monitoring

We present the development of a compact antineutrino detector for the purpose of nuclear reactor monitoring, improving upon a previously successful design. Our paper will describe the design improvements of the detector which increases the antineutrino detection efficiency threefold over the previous effort. There are two main design improvements over previous generations of detectors for nuclear reactor monitoring: dual-ended optical readout and single volume detection mass. The dual-ended optical readout eliminates the need for fiducialization and increases the uniformity of the detector's optical response. The containment of the detection mass in a single active volume provides more target mass per detector footprint, a key design criteria for operating within a nuclear power plant. This technology could allow for real-time monitoring of the evolution of a nuclear reactor core, independent of reactor operator declarations of fuel inventories, and may be of interest to the safeguards community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Damage Studies and Operation of the DØ Luminosity Monitor

The D0 Luminosity Monitor (LM) employs scintillating wedges with photomultiplier tube readout to detect particles from inelastic collisions in p interactions at the Fermilab Tevatron Collider. The Luminosity Monitor provides a real-time measurement of the relative luminosity during data-taking, and, with the determination of the effective inelastic cross section, it also provides an absolute measurement of the luminosity delivered to the D0 Experiment, which is later used for normalization of D0 physics results. In the course of normal Tevatron operations these scintillators accrue significant radiation damage. Operating parameters are monitored and adjusted to compensate for this degradation, and the scintillators are periodically replaced to facilitate stable performance. Results from radiation damage studies to the scintillator as well as the stability of the luminosity measurement will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying non-reference sites to guide stream restoration and long-term monitoring

The reference condition paradigm has served as the standard for assessing the outcomes of restoration projects, particularly their success in meeting project objectives. One limitation of relying solely on the reference condition in designing and monitoring restoration projects is that reference conditions do not necessarily elucidate impairments to effective restoration, especially diagnosing the causal mechanisms behind unsuccessful outcomes. We provide a spatial framework to select both reference and non-reference streams to guide restoration planning and long-term monitoring through reliance on altered ecosystems to understand processes that govern ecosystem biophysical properties and ecosystem responses to restoration practices. We then applied the spatial framework to East Fork Poplar Creek (EFPC), Tennessee (USA), a system receiving 30 years of remediation and pollution abatement actions from intense industrialization, pollution, and urbanization. Out of >13,000 stream reaches, we identified anywhere from 4 to 48 reaches, depending on the scenario, that could be used in restoration planning and monitoring for specific sites. Furthermore, comparison of fish species composition at these sites compared to EFPC sites were used to generate hypotheses of mechanisms limiting the ecological recovery following remediation. We suggest that understanding the relative role of anthropogenic pressures in governing ecosystem responses is required to successful, process-driven restoration.

54 ENVIRONMENTAL SCIENCES↗

A disposable bulk-acoustic-wave microalga trapping device for real-time water monitoring

Recently, there has been an increase in the use of algal physiology as a convenient and useful indicator for monitoring of water quality in aquatic ecosystems. However, current methods for monitoring algal physiology are high-cost, power intensive, and have limited sensitivity for practical samples in which algal concentration is low. In order to alleviate these problems, we developed a simple-to-fabricate acoustophoretic particle trapping device that can effectively enrich various types of microalgae such as chlorella and diatoms for real-time monitoring of water quality. This microalgae trap is fabricated by embedding a piezoelectric resonator in a single channel. In comparison to previously reported acoustophoretic particle traps, this device has a simple structure and does not require sheath flows, which makes the device low cost and simple to fabricate and operate. Using Chlorella kessleri and the marine diatom Thalassiosira pseudonana as model algae, we report the microalgae trap has demonstrated notable particle trapping efficiencies between 82 % to 74 % for Chlorella with a through-flow of 0.5 μl/min to 2.7 μl/min and 85 % to 79 % for diatoms with a 0.5 μl/min to 4 μl/min through-flow. The trap has also shown to simultaneously trap Chlorella and diatoms at different heights of the microchannel. This device has high promise for trapping, separating and manipulating microalgae.

47 OTHER INSTRUMENTATION↗

Calibration and field deployment of low-cost sensor network to monitor underground pipeline leakage

Recent technological advances in methane detection have improved leak detection and repair. However, current methods to reliably measure methane concentrations rely on expensive instruments or demand significant labor input. There is interest in using affordable methane sensors that are responsive to ppmv level changes in methane concentrations in both urban and rural environments for monitoring underground natural gas pipeline leaks. This is especially relevant for situations where potentially significant leaks cannot be repaired immediately or smaller leaks that require long-term monitoring and further evaluation. In this work, a low-cost sensor unit, equipped with a metal oxide sensor, was designed, built, and calibrated over a wide range of methane concentrations and environmental conditions in preparation for field application. A network of these sensors was then installed at the test site and used to measure methane concentrations at ground level above known sub-surface natural gas emissions which emulated underground gas pipeline leaks. This low-cost sensor network measured over 4 days total for the two different known leakage rates. Results demonstrate that the sensors can continuously measure relative methane variability for extended periods but require calibration for a wide range of temperature and humidity conditions to properly determine absolute gas (i.e., methane) concentrations. Furthermore, when a regression analysis was conducted to evaluate the effects of meteorological parameters on methane concentration, air temperature and wind speed have strong impacts on the concentration. Overall, the network approach allows improved identification of leak location and monitoring of underground natural gas leaks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ ATR-IR monitoring of hydrothermal carbonation of wollastonite

In-situ reaction monitoring allows for the development of reaction models for hydrothermal carbonation reactions, which have recently gained attention due to their importance in CO 2 sequestration and utilization. Here, we measured the carbonation kinetics of wollastonite (β- CaSiO 3 ) powder compacts under hydrothermal conditions (90°C and 2.4atm) with the help of optical fiber-based attenuated total reflectance infrared spectroscopy (ATR-IR). Further, the fiber probe was positioned at the target area to study the reaction chemistry at the desired region of the powder compact. Absorbances of solid reactants and products were monitored throughout the entire reaction in the 1000–1600cm -1 spectral range. ATR-IR enabled the detection of amorphous silica, which allowed all solid reactants (β-CaSiO 3 ) and products (CaCO 3 and SiO 2 ) to be monitored independently and simultaneously. A linear proportionality constant between absorbance and CaCO 3 phase concentration was determined and used to construct a reaction kinetics profile for carbonate formation, which revealed a rapid reaction onset, followed by two distinct slower decaying regimes.

42 ENGINEERING↗