Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Advanced Imaging Techniques in Skull Base Osteomyelitis Due to Malignant Otitis Externa

Purpose of Review: To give an up-to-date overview of the strengths and weaknesses of current imaging modalities in diagnosis and follow-up of skull base osteomyelitis (SBO). Recent Findings: CT and MRI are both used for anatomical imaging, and nuclear techniques aid in functional process imaging. Hybrid techniques PET-CT and PET-MRI are the newest modalities which combine imaging strengths. Summary: No single modality is able to address the scope of SBO. A combination of functional and anatomical imaging is needed, in the case of newly suspected SBO we suggest the use of PET-MRI (T1, T2, T1-FS-GADO, DWI) and separate HRCT for diagnosis and follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the polarization of non-Gaussian optical quantum field: Higher-order optical-polarization

Polarization of light signifies transversal, anisotropic and asymmetrical statistical properties of electromagnetic radiation about the direction of propagation. Traditionally, optical-polarization is characterized by Stokes’ theory susceptible to be insufficient in assessing the polarization structure of optical quantum fields and, also, does not decipher the twin characteristic polarization parameters (‘ratio of real amplitudes and difference in phases’). An alternative way, in the spirit of classical description of optical-polarization, is introduced which can be generalized to deal higher-order polarization of quantum light, particularly, prepared in non-Gaussian Schrodinger Cat or Cat-like states and entangled bi-modal coherent states. On account of pseudo mono-modal or multi-modal nature of such optical quantum field, higher-order polarization is seen to be highly sensitive to the basis of description. -- Highlights: •We have generalized the usual concept of optical-polarization. •A concept of higher-order optical-polarization is introduced. •This concept is applied to compute the polarization-parameters of non-Gaussian Optical field. •To the best of our knowledge, no study is performed which investigates such optical quantum field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Analysis of Direct-injection spark-ignition (DISI) soot morphology

We have characterized particle emissions produced by a 4-cylinder, 2.0 L DISI engine using transmission electron microscopy (TEM) and image analysis. Analyses of soot morphology provide insight to particle formation mechanisms and strategies for prevention. Particle emissions generated by two fueling strategies were investigated, early injection and injection modified for low particle number concentration emissions. A blend of 20% ethanol and 80% emissions certification gasoline was used for the study given the likelihood of increased ethanol content in widely available fuel. In total, about 200 particles and 3000 primary soot spherules were individually measured. For the fuel injection strategy which produced low particle number concentration emissions, we found a prevalence of single solid sub-25 nm particles and fractal-like aggregates. The modal diameter of single solid particles and aggregate primary particles was between 10 and 15 nm. Solid particles as small as 6 nm were present. Although nanoparticle aggregates had fractal-like morphology similar to diesel soot, the average primary particle diameter per aggregate had a much wider range that spanned from 7 to 60 nm. For the early fuel injection strategy, liquid droplets were prevalent, and the modal average primary particle diameter was between 20 and 25 nm. The presence of liquid droplets may have been the result of unburned fuel and/or lubricating oil originating from fuel impingement on the piston or cylinder wall; the larger modal aggregate primary particle diameter suggests greater fuel-rich zones in-cylinder than for the low particle number concentration point. However, both conditions produced aggregates with a wide range of primary particle diameters, which indicates heterogeneous fuel and air mixing.

02 PETROLEUM↗

Multimodal sensor fusion framework for residential building occupancy detection

For several years now, smart building energy systems have been a research area of intensive activity. In light of the increasing need for sustainable buildings and energy systems, this trend motivates an increasing need for a solution to reduce carbon dioxide emissions and improve energy efficiency. This work proposes a high-performing and transferable occupancy detection framework that combines sensor data from different data modalities, including time series environmental data (temperature, humidity, and illuminance), image data, and acoustic energy data using ensemble method. To draw out the best prediction performance in each modality, the proposed framework was developed, including various models that were designed to learn the occupancy patterns reflected in the physical data streams. To tackle the time series environmental data, we designed two variants of an occupancy detection spatiotemporal pattern network (Occ-STPN) that performs both feature level and decision level fusion, respectively. We also propose a new metric; the fading memory mean square error (FMMSE), that provides a fair evaluation and penalization of delayed occupancy predictions. Multiple open-sourced datasets, including the Electricity Consumption and Occupancy and the University of California, Irvine's (UCI) building occupancy detection dataset, along with our own real data collected from six different houses, were used to validate the algorithms' performance. The experimental results presented herein break down the performance for each sensing modality, and a detailed analysis of the performance is also discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Outcomes in Women Treated With MammoSite Brachytherapy or Whole Breast Irradiation Stratified by ASTRO Accelerated Partial Breast Irradiation Consensus Statement Groups

Purpose: The American Society for Radiation Oncology published a Consensus Statement for accelerated partial breast irradiation identifying three groups: Suitable, Cautionary, and Unsuitable. The objective of this study was to compare oncologic outcomes in women treated with MammoSite brachytherapy (MB) vs. whole breast irradiation (WBI) after stratification into Statement groups. Methods: Eligible women had invasive carcinoma or ductal carcinoma in situ (DCIS) {<=}3 cm, and {<=}3 lymph nodes positive. Women were stratified by radiation modality and Statement groups. Survival analysis methods including Kaplan-Meier estimation, Cox regression, and competing risks analysis were used to assess overall survival (OS), disease-free survival (DFS), time to local failure (TTLF), and tumor bed failure (TBF). Results: A total of 459 (183 MB and 276 WBI) patients were treated from 2002 to 2009. After a median follow-up of 45 months, we found no statistical differences by stratification group or radiation modality with regard to OS and DFS. At 4 years TTLF or TBF were not statistically different between the cohorts. Univariate analysis in the MB cohort revealed that nodal positivity (pN1 vs. pN0) was related to TTLF (hazard ratio 6.39, p = 0.02). There was a suggestion that DCIS histology had an increased risk of failure when compared with invasive ductal carcinoma (hazard ratio 3.57, p = 0.06). Conclusions: MB and WBI patients stratified by Statement groups seem to combine women who will have similar outcomes regardless of radiation modality. Although outcomes were similar, we remain guarded in overinterpretation of these preliminary results until further analysis and long-term follow-up data become available. Caution should be used in treating women with DCIS or pN1 disease with MB.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Primary Mucosa-Associated Lymphoid Tissue Lymphoma of the Salivary Glands: A Multicenter Rare Cancer Network Study

Purpose: Involvement of salivary glands with mucosa-associated lymphoid tissue (MALT) lymphoma is rare. This retrospective study was performed to assess the clinical profile, treatment outcome, and prognostic factors of MALT lymphoma of the salivary glands. Methods and Materials: Thirteen member centers of the Rare Cancer Network from 10 countries participated, providing data on 63 patients. The median age was 58 years; 47 patients were female and 16 were male. The parotid glands were involved in 49 cases, submandibular in 15, and minor glands in 3. Multiple glands were involved in 9 patients. Staging was as follows: IE in 34, IIE in 12, IIIE in 2, and IV in 15 patients. Results: Surgery (S) alone was performed in 9, radiotherapy (RT) alone in 8, and chemotherapy (CT) alone in 4 patients. Forty-one patients received combined modality treatment (S + RT in 23, S + CT in 8, RT + CT in 4, and all three modalities in 6 patients). No active treatment was given in one case. After initial treatment there was no tumor in 57 patients and residual tumor in 5. Tumor progression was observed in 23 (36.5%) (local in 1, other salivary glands in 10, lymph nodes in 11, and elsewhere in 6). Five patients died of disease progression and the other 5 of other causes. The 5-year disease-free survival, disease-specific survival, and overall survival were 54.4%, 93.2%, and 81.7%, respectively. Factors influencing disease-free survival were use of RT, stage, and residual tumor (p < 0.01). Factors influencing disease-specific survival were stage, recurrence, and residual tumor (p < 0.01). Conclusions: To our knowledge, this report represents the largest series of MALT lymphomas of the salivary glands published to date. This disease may involve all salivary glands either initially or subsequently in 30% of patients. Recurrences may occur in up to 35% of patients at 5 years; however, survival is not affected. Radiotherapy is the only treatment modality that improves disease-free survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modern Radiation Therapy for Hodgkin Lymphoma: Field and Dose Guidelines From the International Lymphoma Radiation Oncology Group (ILROG)

Radiation therapy (RT) is the most effective single modality for local control of Hodgkin lymphoma (HL) and an important component of therapy for many patients. These guidelines have been developed to address the use of RT in HL in the modern era of combined modality treatment. The role of reduced volumes and doses is addressed, integrating modern imaging with 3-dimensional (3D) planning and advanced techniques of treatment delivery. The previously applied extended field (EF) and original involved field (IF) techniques, which treated larger volumes based on nodal stations, have now been replaced by the use of limited volumes, based solely on detectable nodal (and extranodal extension) involvement at presentation, using contrast-enhanced computed tomography, positron emission tomography/computed tomography, magnetic resonance imaging, or a combination of these techniques. The International Commission on Radiation Units and Measurements concepts of gross tumor volume, clinical target volume, internal target volume, and planning target volume are used for defining the targeted volumes. Newer treatment techniques, including intensity modulated radiation therapy, breath-hold, image guided radiation therapy, and 4-dimensional imaging, should be implemented when their use is expected to decrease significantly the risk for normal tissue damage while still achieving the primary goal of local tumor control. The highly conformal involved node radiation therapy (INRT), recently introduced for patients for whom optimal imaging is available, is explained. A new concept, involved site radiation therapy (ISRT), is introduced as the standard conformal therapy for the scenario, commonly encountered, wherein optimal imaging is not available. There is increasing evidence that RT doses used in the past are higher than necessary for disease control in this era of combined modality therapy. The use of INRT and of lower doses in early-stage HL is supported by available data. Although the use of ISRT has not yet been validated in a formal study, it is more conservative than INRT, accounting for suboptimal information and appropriately designed for safe local disease control. The goal of modern smaller field radiation therapy is to reduce both treatment volume and treatment dose while maintaining efficacy and minimizing acute and late sequelae. This review is a consensus of the International Lymphoma Radiation Oncology Group (ILROG) Steering Committee regarding the modern approach to RT in the treatment of HL, outlining a new concept of ISRT in which reduced treatment volumes are planned for the effective control of involved sites of HL. Nodal and extranodal non-Hodgkin lymphomas (NHL) are covered separately by ILROG guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Respiratory Motion on Passively Scattered Proton Therapy Versus Intensity Modulated Photon Therapy for Stage III Lung Cancer: Are Proton Plans More Sensitive to Breathing Motion?

Purpose: To quantify and compare the effects of respiratory motion on paired passively scattered proton therapy (PSPT) and intensity modulated photon therapy (IMRT) plans; and to establish the relationship between the magnitude of tumor motion and the respiratory-induced dose difference for both modalities. Methods and Materials: In a randomized clinical trial comparing PSPT and IMRT, radiation therapy plans have been designed according to common planning protocols. Four-dimensional (4D) dose was computed for PSPT and IMRT plans for a patient cohort with respiratory motion ranging from 3 to 17 mm. Image registration and dose accumulation were performed using grayscale-based deformable image registration algorithms. The dose–volume histogram (DVH) differences (4D-3D [3D = 3-dimensional]) were compared for PSPT and IMRT. Changes in 4D-3D dose were correlated to the magnitude of tumor respiratory motion. Results: The average 4D-3D dose to 95% of the internal target volume was close to zero, with 19 of 20 patients within 1% of prescribed dose for both modalities. The mean 4D-3D between the 2 modalities was not statistically significant (P<.05) for all dose–volume histogram indices (mean ± SD) except the lung V5 (PSPT: +1.1% ± 0.9%; IMRT: +0.4% ± 1.2%) and maximum cord dose (PSPT: +1.5 ± 2.9 Gy; IMRT: 0.0 ± 0.2 Gy). Changes in 4D-3D dose were correlated to tumor motion for only 2 indices: dose to 95% planning target volume, and heterogeneity index. Conclusions: With our current margin formalisms, target coverage was maintained in the presence of respiratory motion up to 17 mm for both PSPT and IMRT. Only 2 of 11 4D-3D indices (lung V5 and spinal cord maximum) were statistically distinguishable between PSPT and IMRT, contrary to the notion that proton therapy will be more susceptible to respiratory motion. Because of the lack of strong correlations with 4D-3D dose differences in PSPT and IMRT, the extent of tumor motion was not an adequate predictor of potential dosimetric error caused by breathing motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison and Limitations of DVH-Based NTCP Models Derived From 3D-CRT and IMRT Data for Prediction of Gastrointestinal Toxicities in Prostate Cancer Patients by Using Propensity Score Matched Pair Analysis

Purpose: This study compared normal tissue complication probability (NTCP) modeling of chronic gastrointestinal toxicities following prostate cancer treatment for 2 treatment modalities. Possible factors causing discrepancies in optimal NTCP model parameters between 3-dimensional conformal radiation therapy (3D-CRT) and intensity modulated RT (IMRT) were analyzed and discussed, including the impact of patient characteristics, image guidance, toxicity scoring bias, and NTCP model limitations. Methods and Materials: Rectal wall dose-volume histograms of 1115 patients treated for prostate cancer under an adaptive radiation therapy protocol were used to model gastrointestinal toxicity grade ≥2 (according to Common Terminology Criteria for Adverse Events). A total of 457 patients were treated with 3D-CRT and 658 with IMRT. 3D-CRT patients were matched to IMRT patients based on various patient characteristics, using a propensity score–based algorithm. Parameters of the Lyman equivalent uniform dose and cut-off dose logistic regression NTCP models were estimated for the 2 matched treatment modalities and the combined group. Results: After they were matched, the 3D-CRT and IMRT groups contained 275 and 550 patients with a large discrepancy of 28.7% versus 7.8% toxicities, respectively (P<.001). For both NTCP models, optimal parameters found for the 3D-CRT groups did not fit the IMRT patients well and vice versa. Models developed for the combined data overestimated NTCP for the IMRT patients and underestimated NTCP for the 3D-CRT group. Conclusions: Our analysis did not reveal a single definitive cause for discrepancies of model parameters between 3D-CRT and IMRT. Patient characteristics and bias in toxicity scoring, as well as image guidance alone, are unlikely causes of the large discrepancy of toxicities. Whether the cause was inherent to the specific NTCP models used in this study needs to be verified by future investigations. Because IMRT is increasingly used clinically, it is important that appropriate NTCP model parameters are determined for this treatment modality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Short-Term and Intermediate-Term Risk of Second Neoplasms After Diagnosis and Treatment of Unilateral Vestibular Schwannoma: Analysis of 9460 Cases

Purpose: To determine the incidence of second intracranial neoplasms after the diagnosis and treatment of sporadic vestibular schwannoma (VS). Methods and Materials: Analysis of the Surveillance, Epidemiology, and End Results (SEER) database including all patients identified with a diagnosis of VS and a second intracranial tumor. The Kaplan-Meier method was used to determine the incidence of second tumors while allowing for censoring at loss to follow-up or death. Multivariable associations between treatment modality and second tumor formation were explored using Cox proportional hazards regression analysis. Two illustrative cases are also presented. Results: In all, 9460 patients with unilateral VS were identified between 2004 and 2012. Overall, 66 (0.7%) patients experienced a separate intracranial tumor, benign or malignant, after treatment of VS. Kaplan-Meier estimates for time to second neoplasm at 1, 3, and 5 years were 0.3%, 0.7%, and 0.8%, respectively. Multivariable comparison between VS treatment modalities revealed that the risk of second tumor formation was similar between radiation and surgery (hazard ratio [HR] 0.74; 95% confidence interval [CI] 0.36-1.51; P=.93) but greater for tumors managed with observation alone compared with radiation (HR 2.48; 95% CI 1.31-4.71; P<.01). A total of 6 (0.06%) intracranial malignancies were diagnosed after VS treatment. Kaplan-Meier estimates for time to malignancy at 1, 3, and 5 years were 0%, 0.1%, and 0.1%, respectively. After adjustment for age at diagnosis, sex, and treatment modality, the probability of malignancy after radiation was not greater than after observation alone or microsurgery (HR 4.88; 95% CI 0.85-28.14; P=.08) during the study period. Conclusions: The risk for the development of a second intracranial neoplasm, benign or malignant, at 5 years after treatment of unilateral VS is approximately 0.8%, whereas the risk of acquiring a separate malignancy is 0.1%, or approximately 1 per 1000 cases. The short-term and intermediate-term incidence of second neoplasm after radiation of VS is not greater than the incidence after microsurgery or observation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Magnetic Resonance Imaging and Computed Tomography for Breast Target Volume Delineation in Prone and Supine Positions

Purpose: To determine whether T2-weighted MRI improves seroma cavity (SC) and whole breast (WB) interobserver conformity for radiation therapy purposes, compared with the gold standard of CT, both in the prone and supine positions. Methods and Materials: Eleven observers (2 radiologists and 9 radiation oncologists) delineated SC and WB clinical target volumes (CTVs) on T2-weighted MRI and CT supine and prone scans (4 scans per patient) for 33 patient datasets. Individual observer's volumes were compared using the Dice similarity coefficient, volume overlap index, center of mass shift, and Hausdorff distances. An average cavity visualization score was also determined. Results: Imaging modality did not affect interobserver variation for WB CTVs. Prone WB CTVs were larger in volume and more conformal than supine CTVs (on both MRI and CT). Seroma cavity volumes were larger on CT than on MRI. Seroma cavity volumes proved to be comparable in interobserver conformity in both modalities (volume overlap index of 0.57 (95% Confidence Interval (CI) 0.54-0.60) for CT supine and 0.52 (95% CI 0.48-0.56) for MRI supine, 0.56 (95% CI 0.53-0.59) for CT prone and 0.55 (95% CI 0.51-0.59) for MRI prone); however, after registering modalities together the intermodality variation (Dice similarity coefficient of 0.41 (95% CI 0.36-0.46) for supine and 0.38 (0.34-0.42) for prone) was larger than the interobserver variability for SC, despite the location typically remaining constant. Conclusions: Magnetic resonance imaging interobserver variation was comparable to CT for the WB CTV and SC delineation, in both prone and supine positions. Although the cavity visualization score and interobserver concordance was not significantly higher for MRI than for CT, the SCs were smaller on MRI, potentially owing to clearer SC definition, especially on T2-weighted MR images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison Between Low-Dose-Rate Brachytherapy With or Without Androgen Deprivation, External Beam Radiation Therapy With or Without Androgen Deprivation, and Radical Prostatectomy With or Without Adjuvant or Salvage Radiation Therapy for High-Risk Prostate Cancer

Purpose: We compare the efficacy and toxicity among the 3 major modalities available used to treat high-risk prostate cancer (HRCaP). Methods and Materials: From 1996 to 2012, 2557 HRCaP patients were treated: 734 received external beam radiation therapy (EBRT) with or without androgen deprivation therapy (ADT), 515 received low-dose-rate prostate brachytherapy (LDR) with or without ADT, and 1308 received radical prostatectomy (RP) with or without EBRT. Biochemical relapse-free survival (bRFS), clinical relapse-free survival (cRFS), and prostate cancer–specific mortality (PCSM) were assessed. Toxicity was assessed using the Common Terminology Criteria for Adverse Events, version 4.03. The log-rank test compared bRFS and cRFS among the modalities, and Cox regression identified factors associated with bRFS and cRFS. Gray's test compared differences in late toxicity and PSCM among the modalities. Competing risk regression identified factors associated with PCSM. Results: The median follow-up time and age were 63.5 months and 65 years, respectively. The bRFS at 5 and 10 years, respectively, was 74% and 53% for EBRT, 74% and 52% for LDR, and 65% and 47% for RP (P=.0001). The cRFS at 5 and 10 years, respectively, was 85% and 73% for EBRT, 90% and 76% for LDR, and 89% and 75% for RP (P=.121). The PCSM at 5 and 10 years, respectively, was 5.3% and 11.2% for EBRT, 3.2% and 3.6% for LDR, and 2.8% and 6.8% for RP (P=.0004). The 10-year cumulative incidence of ≥grade 3 genitourinary toxicity was 8.1% for EBRT, 7.2% for LDR, and 16.4% for RP (P<.0001). The 10-year cumulative incidence of ≥grade 3 gastrointestinal toxicity was 4.6% for EBRT, 1.1% for LDR, and 1.0% for RP (P<.0001). Conclusion: HRCaP treated with EBRT, LDR, or RP yields efficacy showing better bRFS for LDR and EBRT relative to RP, equivalence for cRFS, and a PCSM advantage of LDR and RP over EBRT. The toxicity is lowest for LDR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Therapy Research: A Global Analysis 2001-2015

Radiation therapy is a core modality of cancer treatment; however, concerns have been expressed regarding its underutilization and its lack of prioritization as a research domain relative to other cancer treatment modalities, despite its rapid technical evolution. It is therefore important to understand, from a public policy perspective, the evolution of global radiation therapy research, to identify strengths, weaknesses, and opportunities. This study used a bibliometric approach to undertake a quantitative analysis of global radiation therapy research published between 2001 and 2015 and available in the Web of Science (Wos) database, with particular focus on the 25 leading research-active countries. A total of 62,550 radiation therapy research articles from 127 countries, published in 2531 international journals, were analyzed. The United States was responsible for 32.3% of these outputs, followed by Japan (8.0%) and Germany (7.7%). Nearly half of all publications related to preparation and delivery of radiation therapy, combined-modality regimens, and dose fractionation studies. Health services research, palliative care, and quality of life studies represented only 2%, 5%, and 4% of all research outputs, respectively. Countries varied significantly in their commitment to different research domains, and trial-related publications represented only 5.1% of total output. Research impact was analyzed according to 3 different citation scores, with research outputs from Denmark, The Netherlands, and the United States consistently the highest ranked. Globally, radiation therapy publication outputs continue to increase but lag behind other spheres of cancer management. The types of radiation therapy research undertaken appear to be regionally patterned, and there is a clear disconcordance between the volume of research output from individual countries and its citation impact. Greater support for radiation therapy research in low- and middle-income countries is required, including international collaboration. The study findings are expected to provide the requisite knowledge to guide future radiation therapy research programs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bayesian analysis of the flutter margin method in aeroelasticity

A Bayesian statistical framework is presented for Zimmerman and Weissenburger flutter margin method which considers the uncertainties in aeroelastic modal parameters. The proposed methodology overcomes the limitations of the previously developed least-square based estimation technique which relies on the Gaussian approximation of the flutter margin probability density function (pdf). Using the measured free-decay responses at subcritical (preflutter) airspeeds, the joint non-Gaussain posterior pdf of the modal parameters is sampled using the Metropolis–Hastings (MH) Markov chain Monte Carlo (MCMC) algorithm. The posterior MCMC samples of the modal parameters are then used to obtain the flutter margin pdfs and finally the flutter speed pdf. The usefulness of the Bayesian flutter margin method is demonstrated using synthetic data generated from a two-degree-of-freedom pitch-plunge aeroelastic model. The robustness of the statistical framework is demonstrated using different sets of measurement data. In conclusion, it will be shown that the probabilistic (Bayesian) approach reduces the number of test points required in providing a flutter speed estimate for a given accuracy and precision.

97 MATHEMATICS AND COMPUTING↗

Application of X-ray computed tomography for the characterization of graphite morphology in compact-graphite iron

Highlights: • X-ray Tomography is a powerful technique for graphite morphology characterization. • 3D characterization reveals true nodularity and spatial connectivity of graphite. • Tri-modal distribution of SG suggests a multi-stage graphite nucleation process. - Abstract: In the present study, high-energy X-ray tomography technique was used to characterize the graphite morphology of compact graphite iron. The size, shape, spatial connectivity and structure of different graphite morphologies were examined in 3D using computer-aided image analysis. In addition, nodularity analysis was performed in 3D and the results are compared to the traditional 2D technique. It is found that the variation of nodularity within 2 × 2 × 1.2 mm{sup 3} of the sample can be as high as 20 (%) from 2D analysis and the averaged nodularity (2D) is higher than that from 3D analysis. The size distribution of spheroidal graphite shows a tri-modal distribution, which suggests a multi-step nucleation process during solidification.

36 MATERIALS SCIENCE↗

Development of novel Cu-Cr-Nb-Zr alloys with the aid of computational thermodynamics

Multi-modal precipitate distribution in the microstructure, with coarse precipitates pinning the grain boundaries and finer precipitates strengthening the matrix, is beneficial to suppress grain boundary sliding and dislocation creep, respectively, of structural materials. However, achievement of a multi-modal precipitate distribution remains a challenge in developing creep-resistant advanced Cu alloys while retaining high strength and high conductivity at elevated temperature. This work overcame this challenge with the aid of computational thermodynamics. Thermodynamic models for Gibbs energy functions of phases in the Cu-Cr-Nb-Zr system have been developed in this study. These models were then used to calculate solidification paths and phase equilibria at different temperatures, guiding the design of chemical composition and heat treatment parameters of novel copper alloys with a target multi-modal distribution of precipitates. The new alloy, fabricated through traditional ingot metallurgy method, has achieved the desired microstructure as validated by optical and transmission electron microscopy. Electrical conductivity and mechanical properties were screened and compared with the existing commercial Cu alloys.

36 MATERIALS SCIENCE↗

Comparison of whole-field simultaneous integrated boost VMAT and IMRT in the treatment of nasopharyngeal cancer

To study the feasibility of using volumetric-modulated arc therapy (VMAT) to deliver whole-field simultaneous integrated boost (WF-SIB) to treat patients with nasopharyngeal cancer (NPC). WF-SIB intensity-modulated radiotherapy (IMRT) plans, one-arc WF-SIB VMAT plans, and two-arc WF-SIB VMAT plans were generated with identical objective functions for 8 patients with NPC of various stages. Isodose distributions and dose-volume histograms were evaluated. Dosimetric and biological quality indices of clinical target volume (CTV) and organs at risk (OARs) were calculated to study the optimization capability of these 3 modalities in the treatment of patients with NPC. The optimization time, delivery time, required monitor units (MUs), and delivery accuracy were also compared to investigate the feasibility of these 3 modalities. There was no significant difference (p = 0.92) in target coverage (TC) between WF-SIB IMRT (99.00 ± 0.79) and two-arc WF-SIB VMAT (97.98 ± 1.29). However, both had higher TC than one-arc VMAT plans (89.92 ± 6.32, p < 0.01). IMRT demonstrated the best protection of the spinal cord, whereas two-arc VMAT showed the minimum D{sub max} to OARs. No other significant differences were observed among these 3 modalities on CTV coverage and OAR sparing. The delivery and MU efficiency of one-arc and two-arc WF-SIB VMAT were greatly improved compared with WF-SIB IMRT. The optimization time of one-arc and two-arc WF-SIB VMAT plans were 5 and 10 times greater than that of WF-SIB IMRT, respectively. The delivery accuracy of WF-SIB VMAT was not affected by the increased freedom. For patients with NPC, one-arc WF-SIB VMAT might not be able to achieve sufficient TC, whereas two-arc WF-SIB VMAT was able to achieve reasonable TC. No significant advantage on OAR protection was demonstrated by VMAT compared with IMRT. WF-SIB VMAT has significantly shorter delivery times, but WF-SIB IMRT may still be the first treatment choice for patients with NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technique for comprehensive head and neck irradiation using 3-dimensional conformal proton therapy

Owing to the technical and logistical complexities of matching photon and proton treatment modalities, we developed and implemented a technique of comprehensive head and neck radiation using 3-dimensional (3D) conformal proton therapy. A monoisocentric technique was used with a 30-cm snout. Cervical lymphatics were treated with 3 fields: a posterior-anterior field with a midline block and a right and a left posterior oblique field. The matchline of the 3 cervical nodal fields with the primary tumor site fields was staggered by 0.5 cm. Comparative intensity-modulated photon plans were later developed for 12 previously treated patients to provide equivalent target coverage, while matching or improving on the proton plans' sparing of organs at risk (OARs). Dosimetry to OARs was evaluated and compared by treatment modality. Comprehensive head and neck irradiation using proton therapy yielded treatment plans with significant dose avoidance of the oral cavity and midline neck structures. When compared with the generated intensity-modulated radiation therapy (IMRT) plans, the proton treatment plans yielded statistically significant reductions in the mean and integral radiation dose to the oral cavity, larynx, esophagus, and the maximally spared parotid gland. There was no significant difference in mean dose to the lesser-spared parotid gland by treatment modality or in mean or integral dose to the spared submandibular glands. A technique for cervical nodal irradiation using 3D conformal proton therapy with uniform scanning was developed and clinically implemented. Use of proton therapy for cervical nodal irradiation resulted in large volume of dose avoidance to the oral cavity and low dose exposure to midline structures of the larynx and the esophagus, with lower mean and integral dose to assessed OARs when compared with competing IMRT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗