Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Numerical investigations of potential systematic uncertainties in iron opacity measurements at solar interior temperatures

Iron opacity calculations presently disagree with measurements at an electron temperature of ~180–195 eV and an electron density of (2–4)×10 22 cm –3 , conditions similar to those at the base of the solar convection zone. The measurements use x rays to volumetrically heat a thin iron sample that is tamped with low-Z materials. The opacity is inferred from spectrally resolved x-ray transmission measurements. Plasma self-emission, tamper attenuation, and temporal and spatial gradients can all potentially cause systematic errors in the measured opacity spectra. In this article we quantitatively evaluate these potential errors with numerical investigations. The analysis exploits computer simulations that were previously found to reproduce the experimentally measured plasma conditions. The simulations, combined with a spectral synthesis model, enable evaluations of individual and combined potential errors in order to estimate their potential effects on the opacity measurement. Lastly, the results show that the errors considered here do not account for the previously observed model-data discrepancies.

36 MATERIALS SCIENCE↗

Quantitative Comparison of Proprietary and Open-Source Georeferencing Tools for Use with Astronaut Photography

The Crew Earth Observations (CEO) Facility within the Earth Science and Remote Sensing Unit at NASA’s Johnson Space Center supports the acquisition, analysis, and curation of astronaut photography of Earth’s surface and atmosphere. Astronauts on the International Space Station (ISS) respond to requests from CEO to acquire imagery of scientific and education targets, to include high profile targets in response to activations from the International Charter for Space & Major Disasters (also known as the International Disaster Charter, or IDC) and NASA’s Disasters Program. CEO facilitates the acquisition of astronaut photography in response to IDC events and delivers georeferenced data products to the United States Geological Survey (USGS) for distribution to the disaster community. Using GeoRef, an internal web-based tool developed in collaboration with NASA’s Ames Research Center, CEO generates data packages of georeferenced imagery, uncertainty images for assessing control and tie point accuracy, and metadata documenting raw and processed data. Operational experience with the Georef software identified vulnerabilities to internal code and server errors that can significantly increase time of data production. As such, CEO developed a backup procedure in case the GeoRef software experiences front-end or back-end errors. A system using OSGEO’s open-source QGIS software combined with a semi-automated pipeline using the object-oriented Python language and the Geospatial Abstract Library for generating metadata is quantitatively compared to GeoRef’s data package for quality and productivity. Root Mean Square Error (RMSE) provides a standard measurement of data quality as it relates to ground error. Assessing RMSE measurements generated from georeferenced astronaut photographs acquired with different obliquity and focal length offers a comprehensive accuracy assessment of the software’s transformation algorithms. This assessment will indicate the software's ability to produce data products with the least ground-error or highest data quality regarding ground accuracy. In addition, a comparison of the software’s efficiency in generating a data package that includes georeferenced images, metadata, and uncertainty images for measuring tie/ground point error was performed. Initial results, based on the comparison of three nadir-facing astronaut photographs acquired with a 95mm focal length, reveal the QGIS-based system's average RMSE is 2.36 (pixels) suggesting its georectification system produces data products that meet and perhaps improve upon Georef solution's average RMSE of 32.99 (pixels). However, the QGIS system was unable to reproduce two unique Georef data products, uncertainty images for measuring tie and control point errors and a translated unwrapped image. In addition, the Georef software is designed to accept handheld camera pose information from a hardware component (Geosens) scheduled for deployment on the ISS in late 2018; this information is intended to provide increased accuracy and auto-registration capability for astronaut photographs. Future work is expected to determine the QGIS-based georectification system’s potential as an open-source alternative (and operational backup) to Georef for georeferencing the full range of resolutions and viewing angles unique to handheld digital camera imagery in support of ISS disaster response activities.

Jagge, Amy M.↗

Beta systems error analysis

The atmospheric backscatter coefficient, beta, measured with an airborne CO Laser Doppler Velocimeter (LDV) system operating in a continuous wave, focussed model is discussed. The Single Particle Mode (SPM) algorithm, was developed from concept through analysis of an extensive amount of data obtained with the system on board a NASA aircraft. The SPM algorithm is intended to be employed in situations where one particle at a time appears in the sensitive volume of the LDV. In addition to giving the backscatter coefficient, the SPM algorithm also produces as intermediate results the aerosol density and the aerosol backscatter cross section distribution. A second method, which measures only the atmospheric backscatter coefficient, is called the Volume Mode (VM) and was simultaneously employed. The results of these two methods differed by slightly less than an order of magnitude. The measurement uncertainties or other errors in the results of the two methods are examined.

Source record↗

Precision of the calibration of the AXAF engineering test article (VETA) mirrors

Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly.

Schwartz, D. A.↗

Precision of the calibration of the AXAF Engineering Test Article (VETA) mirrors

Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly.

Schwartz, D. A.↗

Direct determination of cellulosic glucan content in starch-containing samples

A simple and highly selective analytical procedure is presented for the determination of cellulosic glucan content in samples that contain both cellulose and starch. This method eliminates the unacceptably large compounding errors of current two-measurement methods. If both starch and cellulose are present before analytical hydrolysis, both will be hydrolyzed to glucose causing bias and inaccuracy in the method. To prevent this interference, the removal of starch prior to cellulosic quantification is crucial. The method presented here is a concise in-series procedure with minimal measurements, eliminating large compounding errors. Sample preparation consists of a starch extraction employing enzymatic hydrolysis followed by a simple filtration and wash. The samples are then subjected to a two-stage acid hydrolysis. The concentration of glucose is determined by ion exchange high-performance liquid chromatography with a Pb 2+ column and a refractive index detector. The cellulosic glucan content is calculated based on the initial dry weight of the starting material. Data for the native biomass materials studied show excellent reproducibility, with coefficients of variance of 3.0% or less associated with the method. This selectivity for cellulosic glucan by the procedure was validated with several analytical techniques such as liquid chromatography coupled with mass spectrometry (LC–MS), Raman spectroscopy, and nuclear magnetic resonance.

09 BIOMASS FUELS↗

Radiometric calibration of a polarization-sensitive sensor

The radiometric accuracy of a sensor is adversely affected by scene polarization if its optical system is sensitive to polarization. Tests performed on the reflective bands of the NS001 Thematic Mapper simulator, an aircraft multispectral scanner, show that it is very sensitive to the polarization state of the incoming radiations. For 100 percent linearly polarized light, errors in the measured intensity vary from -40 to +40 percent, depending on the scan angle and spectral band. To estimate polarization-induced errors in the intensity measured at aircraft level, the intensity and polarization of the atmospheric radiances were simulated using a realistic earth-atmosphere radiative transfer model. For the polarization of atmospheric radiances in the solar meridian plane over a vegetated target, intensity errors may range from -10 to + 10 percent. The polarization-induced errors are highest in the shortest NS001 spectral band (0.450-0.525 microns) because of large atmospheric polarizations contributed by Rayleigh particles and small diluting effects caused by the small contributions of weakly polarized radiations coming from aerosols and the surface. Depending on the illumination and view angles, the errors in derived surface reflectance due to the radiance errors can be very large. In particular, for large off-nadir view angles in the forward scattered direction when the sun is low, the relative errors in the derived surface reflectance can be as large as 4 to 5 times the relative error in the radiances. Polarization sensitivity errors cannot be neglected for the shorter wavelengths when the surface reflectance contribution to atmospheric radiances is very small.

Ahmad, Suraiya P.↗

Spatial sampling errors for a satellite-borne scanning radiometer

The Clouds and Earth's Radiant Energy System (CERES) scanning radiometer is planned as the Earth radiation budget instrument for the Earth Observation System, to be flown in the late 1990's. In order to minimize the spatial sampling errors of the measurements, it is necessary to select design parameters for the instrument such that the resulting point spread function will minimize spatial sampling errors. These errors are described as aliasing and blurring errors. Aliasing errors are due to presence in the measurements of spatial frequencies beyond the Nyquist frequency, and blurring errors are due to attenuation of frequencies below the Nyquist frequency. The design parameters include pixel shape and dimensions, sampling rate, scan period, and time constants of the measurements. For a satellite-borne scanning radiometer, the pixel footprint grows quickly at large nadir angles. The aliasing errors thus decrease with increasing scan angle, but the blurring errors grow quickly. The best design minimizes the sum of these two errors over a range of scan angles. Results of a parameter study are presented, showing effects of data rates, pixel dimensions, spacecraft altitude, and distance from the spacecraft track.

Manalo, Natividad D.↗

The limitations of wind measurement accuracy for balloon systems

The error in horizontal wind field measurements as computed from the trajectory of balloons with linear and quadratic rise rates (as functions of altitude) has been derived. Balloon trajectories through light, moderate, and severe wind fields have been considered. Figures are presented which show the wind error vs altitude for various rise rates in each wind field, assuming linear smoothing of the trajectory data. The rise rate profile of the Jimsphere is analyzed as a special case. The results and figures presented are useful in determining the ultimate capability of rising balloon systems in general and for the Jimsphere system in particular for measuring wind from the surface to 18 km. Using the figures presented, it is possible to estimate the wind accuracy that can be achieved by any type of rising balloon by knowing only its rise rate behavior vs altitude. In addition, the results can be used in balloon design to determine what rise rate function is needed to achieve specified wind accuracies. A table is presented which shows the balloon radius for smooth and roughened spheres needed to achieve 2 to 20 m/sec rise rates at 10 and 14 km altitudes.

Luers, J. K.↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Timing measurement apparatus

Methods, devices and systems for providing accurate measurements of timing errors using optical techniques are described. An example timing measurement device includes an optical hybrid that receives two optical pulse trains and produces two or more phase shifted optical outputs. The timing measurement device further includes two or more optical filters that receive the outputs of the optical hybrid to produce multiple pulse signals with distinctive frequency bands. The device also includes one or more photodetectors and analog-to-digital converters to receive to produce electrical signals in the digital domain corresponding to the optical outputs of the hybrid. A timing error associated with the optical pulse trains can be determined using the electrical signals in digital domain based on a computed phase difference between a first frequency band signal and a second frequency band signal and a computed frequency difference between the first frequency band signal and the second frequency band.

DeVore, Peter Thomas Setsuda↗

Virtual sensors for robust on-line monitoring (OLM) and Diagnostics

Unscheduled shutdown of nuclear power facilities for recalibration and replacement of faulty sensors can be expensive and disruptive to grid management. In this work, we present virtual (software) sensors that can replace a faulty physical sensor for a short duration thus allowing recalibration to be safely deferred to a later time. The virtual sensor model uses a Gaussian process model to process input data from redundant and other nearby sensors. Predicted data includes uncertainty bounds including spatial association uncertainty and measurement noise and error. Using data from an instrumented cooling water flow loop testbed, the virtual sensor model has predicted correct sensor measurements and the associated error corresponding to a faulty sensor.

Analytical study↗

A Simplified Theory of Pile Noise

Here, a theoretical treatment is given of the statistical fluctuations in neutron population which occur in nuclear reactors. The absolute magnitude and frequency dependence of the spectral density of these fluctuations is obtained. The model used assumes that the fluctuations arise from a "noise-equivalent source" whose strength can be easily calculated from fundamental considerations. Calculations are also presented of the fundamental statistical errors in criticality measurements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement Uncertainty of Highly Asymmetrically Curved Elliptical Mirrors Using Multi-Pitch Slope Stitching Technique

Soft X-ray off-axis elliptical mirrors bring new challenges for X-ray mirror metrology. These highly asymmetrically curved elliptical cylindrical mirrors with a total slope range >10 mrad are extremely challenging to measure. Their total slope range exceeds the measuring range of most angular sensors used for X-ray mirror inspection. To overcome this problem, it is possible to stitch partial slope data by measuring the mirror at different pitch angles (multi-pitch angles). By revisiting the theory of the multi-pitch Nano-accuracy Surface Profiler (NSP), we derive the sampling position error on the mirror surface as a function of the mirror height profile and the measurement error of the pitch rotation center. When measuring “extreme”, highly asymmetrically curved, elliptical mirrors, the calculation of the mirror height profile with iterative reconstruction outperforms the classical “flat assumption” (i.e., assuming that the mirror sag is negligible). As demonstrated by our simulations, a proper tolerance evaluation on the measurement of pitch rotation center is needed to assess the measurement accuracy (systematic error) for these strongly aspherical mirrors using the multi-pitch NSP technique. Taking a real design of an “extreme” elliptical mirror as a case study, we conduct a Monte Carlo simulation to mimic the measurement and characterization process to analyze the impact of several error sources. With the measurement uncertainty of the pitch rotation center, the multi-pitch NSP measurement can estimate the grazing angle θ and the chief ray location x o with their uncertainties, as well as the slope residuals.

36 MATERIALS SCIENCE↗

A New Method of Neutron Detecton for UCN Lifetime Measrements

A number of inconsistant neutron lifetime measurements have been reported. The disagreement among the various measurements made with material neutron traps with ultra-cold neutrons (UCN) suggests unaccounted for systematic errors in these measurements. One potential source of error is due to the long emptying times which may be time dependent due to the UCN phase space evolution in the trap. We present a way to reduce this effect.

Morris, C. L.↗

Virtual sensors for robust on-line monitoring (OLM) and diagnostics - 197

Unscheduled shutdown of nuclear power facilities for recalibration and replacement of faulty sensors can be expensive and disruptive to grid management. In this work, we present virtual (software) sensors that can replace a faulty physical sensor for a short duration thus allowing recalibration to be safely deferred to a later time. The virtual sensor model uses a Gaussian process model to process input data from redundant and other nearby sensors. Predicted data includes uncertainty bounds including spatial association uncertainty and measurement noise and error. Using data from an instrumented cooling water flow loop test bed, the virtual sensor model has predicted correct sensor measurements and the associated error corresponding to a faulty sensor. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessing Collision Cross Section Calibration Strategies for Traveling Wave-Based Ion Mobility Separations in Structures for Lossless Ion Manipulations

The collision cross section (CCS) is an important property that aids in the structural characterization of molecules. Here, we investigated the CCS calibration accuracy with traveling waves ion mobility spectrometry (TWIMS) separations in structures for lossless ion manipulations (SLIM) using three sets of calibrants. A series of singly negatively-charged phospholipids and bile acids were calibrated in nitrogen buffer gas using two different TW waveform profiles (square and sine) and amplitudes (20 V0-p, 25 V0-p, and 30 V 0-p ). The calibration errors for the three calibrant sets Agilent tuning mixture and polyalanine, and one assembled in-house showed negligible differences using a sine-shaped TW waveform. Furthermore, calibration errors were all within 1-2 % of the DTIMS measurements, with lower errors for sine waveforms, presumably due to the lower average and maximum fields experienced by ions. Finally, ultrahigh resolution multi-pass (long path length) SLIM TWIMS demonstrated improved CCS calibration for phospholipid and bile acid isomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗