Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement Science Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Plasmonic Field Enhancement of Individual Nanoparticles by Correlated Scanning and Photoemission Electron Microscopy

We present results of a combined two-photon photoemission and scanning electron microscopy investigation to determine the electromagnetic enhancement factors of silver-coated spherical nanoparticles deposited on an atomically flat mica substrate. Femtosecond laser excitation, of the nanoparticles, produces intense photoemission, attributed to near-resonant excitation of localized surface plasmons. Enhancement factors are determined by comparing the respective two-photon photoemission yield measured for equal areas between single nanoparticles to that of the surrounding flat surface. For s-polarized, 400 nm (~ 3.1 eV) femtosecond radiation a distribution of enhancement factors are found with a large percentage (77%) of the nanoparticles falling within a median range. A correlated scanning electron microscopy analysis demonstrated that the nanoparticles typifying the median of the distribution were characterized by ideal spherical shapes and defect-free morphologies. The single largest enhancement factors were in contrast produced by a very small percentage (8%) of the total, for which evidence of silver defect anomalies were found that contributed to the overall structure of the nanoparticle. Comparisons are made between the experimentally measured enhancement factors and previously reported theoretical predictions of the localized surface plasmon near-field intensities for isolated nanometer-sized silver spheres.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance assessment of PHITS simulations for the inverse-kinematic p( 7 Li,n) 7 Be reaction based on fast-neutron measurements with a diamond detector

The inverse-kinematics p( 7 Li,n) 7 Be reaction produces forward-focused neutron emission, offering enhanced usable flux and reduced shielding requirements. Reliable simulation of such neutron fields is essential for the development of compact accelerator-based neutron sources. In this study, a PHITS-based simulation framework for the reaction was experimentally assessed using fast-neutron measurements. Forward-directed neutrons were measured with a diamond neutron detector and quantitatively compared with simulations with newly prepared IK-Frag cross-section file based on the proton-induced reaction data in ENDF/B-VIII.1, TENDL-2023, and JENDL-4.0/HE. Measurements and simulations were performed for incident 7 Li 3+ energies ranging from 15.0 to 25.0 MeV using a 50 μm-thick polypropylene target. For all conditions, the PHITS-based simulation framework reproduced the deposited energy spectra at the correct order of magnitude. The comparison of deposited energy spectra in the diamond detector showed high correlation coefficients across all investigated energies, indicating reasonable agreement in spectral shape between simulations and measurements. This work represents an initial step toward establishing a benchmark for PHITS simulations of the inverse kinematic reaction between an incident lithium-ion and a proton target.

43 PARTICLE ACCELERATORS↗

Final Design for Additional Thermal/Epithermal eXperiments (TEX) with Sodium Chloride Absorbers to Provide Validation Benchmarks for TerraPower

The first set of Thermal/Epithermal eXperiments (TEX) with chlorine absorbers (TEX-Cl) were executed in Q4FY24 and are in the process of being benchmarked for the ICSBEP. TEX-Cl builds upon the TEX-HEU baseline cases that were published in the 2022 International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. TEX-HEU, like TEX-Pu, was designed to be modular to allow for the incorporation of various absorbers and reflectors to test nuclear data and application case needs. For example, TEX-HEU with hafnium (TEX-Hf) utilizes hafnium plates as both absorbers and reflectors, depending on the tested configuration. A second set of chlorine experiments, dubbed More TEX-Cl, are laid out in this report to meet the needs of TerraPower for chlorine validation for their Molten Chloride Fast Reactor (MCFR) systems. TerraPower’s Molten Chloride Reactor Experiment (MCRE) and MCFR are fast molten salt reactors that utilize sodium chloride (NaCl) salt eutectics as the fuel and coolant. The MCRE eutectic is a mixture of NaCl and uranium trichloride (UCl 3 ). An abundant need for chlorine absorption validation has been expressed by multiple members of the community, including Y-12 (whose needs were addressed with the first set of experiments), LANL (whose needs were addressed with the Chlorine Worth Study (CWS)), TerraPower, institute de radioprotection et de sûreté nucléaire (IRSN), Savannah River Nuclear Solutions (SNRS), and others. Of the members who have expressed interest in this validation, most are interested in the fast neutron energy region, where the 35 Cl(n,p) reaction is most prominent. New 35 Cl(n,p) differential cross section measurements performed by LANL at LANCSE show substantial changes to the cross sections (Figure 1) and may be validated through these experiments as some configurations are optimally sensitive to this cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

3-D Volumetric Gamma-ray Imaging and Source Localization with a Mobile Robot - 18124

Radiation detection has largely been a manual inspection process with point sensors such as Geiger-Muller counters and scintillation spectrometers to date. While their observations of source proximity prove useful, they lack the directional information necessary for efficient source localization and characterization in cluttered environments with multiple radiation sources. The recent commercialization of Compton gamma cameras provides directional information to the broader radiation detection community for the first time. This paper presents the integration of a Compton gamma camera with a self-localizing ground robot for accurate 3D radiation mapping. Using the position and orientation of the robot, radiation images from the gamma camera are accumulated over a traversed path in a shared frame of reference to construct a consistent voxel grid-based radiation map. The peaks of the map at pre-specified energy windows are selected as the source location estimates, which are compared to the ground truth source locations. The proposed approach localizes multiple sources to within an average of 0.2 m in two 5 x 4 m{sup 2} and 14 x 6 m{sup 2} laboratory environments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scanning Hall probe microscopy of a diluted magnetic semiconductor

We have measured the micromagnetic properties of a diluted magnetic semiconductor as a function of temperature and applied field with a scanning Hall probe microscope built in our laboratory. The design philosophy for this microscope and some details are described. The samples analyzed in this work are Ga{sub 0.94}Mn{sub 0.06}As films grown by molecular beam epitaxy. We find that the magnetic domains are 2-4 mum wide and fairly stable with temperature. Magnetic clusters are observed above T{sub C}, which we ascribe to MnAs defects too small and sparse to be detected by a superconducting quantum interference device magnetometer.

36 MATERIALS SCIENCE↗

Measurement of the Alfvén Wave Parametric Decay Instability Growth Rate

Alfvén waves, a fundamental mode of magnetized plasmas, are ubiquitous in space and laboratory plasmas. The nonlinear behavior of these modes is thought to play a key role in important problems in space plasma, such as the heating of the solar corona and solar wind turbulence. In particular, theoretical predictions show that these Alfvén waves may be unstable to various parametric instabilities, but space observations of these processes are limited. We demonstrate the first measurement of the Alfvén wave parametric decay instability (PDI) growth rate. Experiments are conducted on the Large Plasma Device at UCLA in which a high amplitude 𝛿⁢𝐵/𝐵 0 ∼ 0.7% pump Alfvén wave is launched from one end of the device and a smaller seed Alfvén wave is launched from the other side. When the frequency of the seed wave is chosen to match the backward wave expected from PDI, damping of the seed wave is reduced. We compare this reduction in damping to the theoretically expected PDI growth rate while accounting for acoustic mode damping. Results show agreement between measurements and theoretical predictions. As a result, this not only provides critical validation for PDI theories and simulations that could help interpret future space observations but also suggests a new way of studying similar nonlinear wave phenomena.

Alfvén waves↗

A Planar Biaxial Experiment Platform for In Situ High-Energy Diffraction Studies

In this work, an experimental platform for multiscale studies of materials subjected to plane stress loads is presented. Specifically, a planar biaxial mechanical load frame with four independent hydraulic actuators capable of applying arbitrary loading paths and ratios of tension and compression was designed and built for in situ diffraction experimentation. The load frame is integrated for use at the Argonne National Laboratory Advanced Photon Source (APS) synchrotron, Sector 1, 1-ID-E endstation and the Los Alamos Neutron Science Center (LANSCE) spallation neutron source, Spectrometer for Materials Research at Temperature and Stress (SMARTS) instrument. Cruciform specimen geometries were designed to experience loading ratios in the gauges commensurate with those applied at the grips, and to minimize interference with diffracted X-rays and neutrons. The finite element models used to design the cruciform specimen geometries were experimentally validated using stereo digital image correlation measurements. This complete planar biaxial in situ diffraction platform provides a new capability for studying multiaxial micromechanics of crystalline materials (e.g., elastic, slip, twinning, phase transformation) and their dependencies on grain size, location, texture, and neighborhood characteristics. The coupling with far-field high energy diffraction microscopy (ff-HEDM) for grain-by-grain measurements provides an additional benefit; provided crystal elastic constants of a material are known, it enables the direct measurement of local and average stress tensors in the gauge sections of cruciform specimens, resolving a long outstanding challenge of planar biaxial mechanical testing.

36 MATERIALS SCIENCE↗

A Thermodynamic and Kenetic Study of the Heterolytic Activation of Hydrogen by Frustrated Borane-Amine Lewis Pairs

Calorimetry is used to measure the reaction enthalpies of hydrogen activation by 2,6-lutidine (Lut), 2,2,6,6-tetramethylpiperidine (TMP), N-methyl-2,2,6,6-tetramethylpiperidine (MeTMP) and tri-tert-butylphosphine (TBP) with tris(pentafluorophenyl)borane (BCF). At 6.6 bar H2 the conversion of the Lewis acid Lewis base pair to the corresponding ionic pair in bromobenzene at 294 K was quantitative in under 60 minutes. Integration of the heat release from the reaction of the Frustrated Lewis Pair (FLP) with hydrogen as a function of time yields a relative rate of hydrogenation in addition to the enthalpy of hydrogenation. The half-lives of hydrogenation range from 230 seconds with TMP, ΔHH2 = -31.5(0.2) kcal/mol, to 1400 seconds with Lut, ΔHH2 = -23.4(0.4) kcal/mol. The 11B NMR spectrum of B(C6F5)3 in bromobenzene exhibits three distinct traits depending on the sterics of the Lewis base; (i) in the presence of pyridine, only the dative bond adduct pyridine--B(C6F5)3 is observed, (ii) in the presence of TMP and MeTMP only the free B(C6F5)3 is observed, and (iii) in the presence of Lut both the free B(C6F5)3 and the Lut--B(C6F5)3 adduct appear in equilibrium. A measure of the change in Keq of Lut + B(C6F5)3 <->Lut--B(C6F5)3 as a function of temperature provides thermodynamic properties of the Lewis acid Lewis base adduct, ΔH = -17.9(1.0) kcal/mol and a ΔS = -49.2(2.5) cal/mol K, suggesting the Lut--B(C6F5)3 adduct is more stable in bromobenzene than in toluene. This research was supported by the U.S. Department of Energy’s Basic Energy Sciences, Division of Chemical Sciences, Biosciences and Geosciences. D.M.C. and A.K. acknowledges support by the Laboratory Directed Research and Development program at the Pacific Northwest National Laboratory (PNNL) to perform kinetic analyses of the calorimetry data. The work was performed in part at EMSL, a national scientific user facility sponsored by the DOE Office of Biological and Environmental Research. EMSL is located at Pacific Northwest National Laboratory (PNNL), which is operated by Battelle for DOE.

calorimetry↗

Study of the Photon Strength Functions for Gadolinium Isotopes with the DANCE Array

The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a specific resonance of a specific isotope in the time-of-flight spectrum and obtain the summed energy spectrum for that isotope. The singles gamma-ray spectrum for each multiplicity can be separated by their DANCE cluster multiplicity. Various photon strength function models are used for comparison with experimentally measured DANCE data and provide insight for understanding the statistical decay properties of deformed nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spent Nuclear Fuel Mechanical Loads in the General Package Drop Scenario

The US Department of Energy Spent Fuel and Waste Science and Technology program is performing research to determine the mechanical loading conditions applied to spent nuclear fuel (SNF) during normal conditions of transportation to inform mechanical tests of SNF and close an important knowledge gap related to the practical disposition of SNF in the US. A recent multi-national collaborative test campaign measured SNF assembly impact response to the 30 cm horizontal package drop scenario, which is a common regulatory basis test of SNF package design. Researchers at Pacific Northwest National Laboratory (PNNL) are using the test data to validate explicit finite element models to calculate the mechanical loads and structural response of spent nuclear fuel assemblies in the as-tested 30 cm horizontal package drop scenario. Once the as-tested package drop model is validated, the next step is to apply the model to the general 30 cm drop scenario, which includes all impact angles, all fuel assembly types, and all burnup conditions. PNNL is developing a damage model that will incorporate the results of finite element parametric studies to establish trends in SNF mechanical loading to various input parameters, like impact orientation and burnup. The damage model will have the capability to estimate mechanical loads for any single set of input parameters, but it will first be used to describe the upper bounds of potential SNF loading in the 30 cm drop scenario. This paper describes PNNL’s progress toward developing the general solution to the problem of spent nuclear fuel mechanical loads in the 30 cm package drop scenario and it describes the next steps in closing the knowledge gap.

Klymyshyn, Nicholas A.↗

Laboratory-Based Thermal Shock Investigation of Heat Flux Sensors for the Mars 2020 Backshell

In 2012 during the entry, descent, and landing of the Mars Science Laboratory (MSL), the MSL Entry, Descent, and Landing Instrumentation (MEDLI) sensor suite was collecting in-flight heatshield pressure and temperature data. The data collected by the MEDLI instruments has since been used for reconstruction of vehicle aerodynamics, atmospheric conditions, aerothermal heating, and Thermal Protection System (TPS) performance as well as material response model validation and refinement. The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite for the Mars 2020 heatshield and backshell is being designed to expand on the measurements and knowledge gained from MEDLI. Similar to MEDLI, MEDLI2 will measure the pressure and temperature of the heatshield. MEDLI2 will additionally measure the temperature, pressure, total heat flux, and radiative heat flux on the backshell. Since the backshell instrumentation is new to MEDLI2, Do No Harm (DNH) testing was conducted on instrumented backshell TPS (SLA-561V) panels. The panels consisted of four pressure port holes, one Mars Entry Atmospheric Data System (MEADS) pressure port plug, one MEDLI2 Integrated Sensor Plug (MISP) thermal plug, and one heat flux sensor. DNH testing was conducted to ensure the performance of the TPS was not degraded due to sensor integration and to characterize any TPS performance changes. The testing consisted of environmental testing— vibration, shock, thermal vacuum (TVAC) cycling— and bounding aerothermal (arc jet) testing.

Miller, R. A.↗

Laboratory-Based Thermal Shock Investigation of Heat Flux Sensors for the Mars 2020 Backshell

In 2012 during the entry, descent, and landing of the Mars Science Laboratory (MSL), the MSL Entry, Descent, and Landing Instrumentation (MEDLI) sensor suite was collecting in-flight heatshield pressure and temperature data. The data collected by the MEDLI instruments has since been used for reconstruction of vehicle aerodynamics, atmospheric conditions, aerothermal heating, and Thermal Protection System (TPS) performance as well as material response model validation and refinement. The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite for the Mars 2020 heatshield and backshell is being designed to expand on the measurements and knowledge gained from MEDLI. Similar to MEDLI, MEDLI2 will measure the pressure and temperature of the heatshield. MEDLI2 will additionally measure the temperature, pressure, total heat flux, and radiative heat flux on the backshell.Since the backshell instrumentation is new to MEDLI2, Do No Harm (DNH) testing was conducted on instrumented backshell TPS (SLA-561V) panels. The panels consisted of four pressure port holes, one Mars Entry Atmospheric Data System (MEADS) pressure port plug, one MEDLI2 Integrated Sensor Plug (MISP) thermal plug, and one heat flux sensor. DNH testing was conducted to ensure the performance of the TPS was not degraded due to sensor integration and to characterize any TPS performance changes. The testing consisted of environmental testing— vibration, shock, thermal vacuum (TVAC) cycling— and bounding aerothermal (arc jet) testing. During arc jet testing, the heat flux sensors embedded in the SLA-561V panels exhibited an unexpected temporary reduction in the heat flux sensor temperature and response. After review of the test results, it was determined that this unexpected response was confined to the two heat flux sensors that experienced the greatest thermal shock condition. This condition consisted of a liquid nitrogen (LN2) bath that induced temperatures of approximately -190°C, and then a transition (thermal shock) to an arc jet test at a heat rate of approximately 21 W/cm2. Both heat flux sensors that were exposed to this thermal shock experienced a blister in the thermal coating during the arc jet test.Two heat flux sensor thermal shock test series were performed to investigate the cause of the blistering and subsequent energy release. In these tests, the heat flux sensor was first cold soaked in either a dry ice or LN2 bath to induce temperatures of approximately -78°C or -190°C, respectively. Then the sensors were thermally shocked using two propane torches with a heat rate of either approximately 8 W/cm2 or 21 W/cm2. The key findings indicated that there is a correlation between thermal shock and the blistering observed in the DNH test series, and that the cause appeared to be rooted in the heat flux sensor epoxy that encapsulates the sensor thermopile.Since the heat flux sensors are required to measure heat fluxes up to 15 W/cm2 during the Mars 2020 entry, a third test series was designed to determine if blistering is an issue at this maximum expected flight heat flux. Results from all three thermal shock test series and a discussion about whether or not blistering of the heat flux sensor thermal coating could be an issue for the Mars 2020 mission will be presented.

Miller, R. A.↗

Selected Studies in High Temperature Chemistry at the NASA Glenn Research Center

Several high temperature chemistry studies, which support NASA missions in both Aeronautics and Space, will be discussed. As will be discussed, collaboration with partners both within NASA and outside of NASA was essential to attaining the goals of each study. The following studies will be presented: 1. Oxidation of the reinforced carbon/carbon on the wing leading edge of the Space Shuttle Orbiter. This was conducted for the Leading Edge Subsystem Problem Resolution Team and involved experts in mass transport, non-destructive evaluation, and mechanical properties. 2. Thermodynamic activity measurement in rare earth silicates for coatings of ceramic hot stage parts in aircraft combustors. This was conducted with colleagues at NASA in support of a larger project involving NASA and the major engine companies. 3. Planetary Science in conjunction with universities a. Thermochemical modeling to describe parts of the Venus atmosphere. b. High temperature vapor studies to describe the possible atmospheres of hot, rocky exoplanets. c. High temperature mass spectrometry for K/Ar dating of minerals. These problems are all addressed with basic laboratory studies and collaboration across multiple disciplines is necessary.

Mass spectrometry, thermodynamics, high temperatur↗

Use of Constrained Gamma Emission Computed Tomography to Evaluate Fission Product Distributions in High-Temperature Materials from a TRISO Fuel Irradiation

An image reconstruction technique was developed to overcome problems with earlier methods of gamma emission computed tomography of graphite rings surrounding the AGR-3/4 TRISO fission product transport experiment. The profiles obtained from the tomography are compared with sampling done via radially resolved destructive sampling techniques. Generally, there is good agreement between profiles measured via destructive sampling of the rings and the tomographic profiles, though at low signal strengths, the tomographic profiles appear elevated.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration of a high resolution grating soft x-ray spectrometer

The calibration of the soft x-ray spectral response of a large radius of curvature, high resolution grating spectrometer (HRGS) with a back-illuminated charge-coupled device detector is reported. The instrument is cross-calibrated for the 10-50 A waveband at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) x-ray source with the EBIT calorimeter spectrometer. The HRGS instrument is designed for laser-produced plasma experiments and is important for making high dynamic range measurements of line intensities, line shapes, and x-ray sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CO2-Binding-Organic-Liquids-Enhanced CO2 Capture using Polarity-Swing-Assisted Regeneration

A new solvent-based CO2 capture process couples the unique attributes of non-aqueous, CO2-binding organic liquids (CO2BOLs) with the newly discovered polarity-swing-assisted regeneration (PSAR) process that is unique to switchable ionic liquids. Laboratory measurements with PSAR indicate the ability to achieve a regeneration effect at 75°C comparable to that at 120°C using thermal regeneration only. Initial measurements also indicate that the kinetic behavior of CO2 release is also improved with PSAR. Abstract cleared PNWD-SA-9743

54 ENVIRONMENTAL SCIENCES↗

Los Alamos National Laboratory Meteorology Monitoring Program: 2018 Data Completeness/Quality Report

This report summarizes data completeness by tower and by instrument for 2018 and compares that data with the Los Alamos National Laboratory (LANL) and American National Standards Institute (ANSI) 2015 standards. This report is designed to make data users aware of data completeness and any data quality issues. LANL meteorology monitoring goals include 95% completeness for all measurements. The ANSI 2015 standard requires 90% completeness for all measurements. This report documents instrument/tower issues as they impact data completeness.

54 ENVIRONMENTAL SCIENCES↗