Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Management Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Resilient Entanglement Distribution in a Multihop Quantum Network

The evolution of quantum networking requires architectures capable of dynamically reconfigurable entanglement distribution to meet diverse user needs and ensure tolerance against transmission disruptions. We introduce multihop quantum networks to improve network reach and resilience by enabling quantum communications across intermediate nodes, thus broadening network connectivity and increasing scalability. We present multihop two-qubit polarization-entanglement distribution within a quantum network at the Oak Ridge National Laboratory campus. Our system uses wavelength-selective switches for adaptive bandwidth management on a software-defined quantum network that integrates a quantum data plane with classical data and control planes, creating a flexible, reconfigurable mesh. Our network distributes entanglement across six nodes within three subnetworks, each located in a separate building, optimizing quantum state fidelity and transmission rate through adaptive resource management. Additionally, we demonstrate the network's resilience by implementing a link recovery approach that monitors and reroutes quantum resources to maintain service continuity despite link failures—paving the way for scalable and reliable quantum networking infrastructures.

Alshowkan, Muneer [Oak Ridge National Laboratory (↗

Networked Control and Optimization for Widescale Integration of Power Electronic Devices in Residential Homes

Power electronics devices are emerging at residential houses, including electric vehicles, energy storage systems, solar photovoltaic systems, and variable-speed air conditioners. Little work has been done on scalable and end-to-end architectures for integrating and engaging large number of residential behind-the-meter assets to provide grid services. In this paper, a framework for integration of a demand management system, home energy management system, and residential smart inverters is presented. Full measured results of inverter response to control signals is also presented.

Starke, Michael↗

StingRAY WEC Risk Register

Risk Registers for major subsystems of the StingRAY WEC completed in compliance with the DOE Risk Management Framework developed by NREL.

16 TIDAL AND WAVE POWER↗

Multi-Agent Hierarchical Deep Reinforcement Learning for HVAC Control With Flexible DERs

As electricity consumption in commercial and residential buildings continues to rise, reducing energy costs presents an increasing challenge. Heating, ventilating, and air-conditioning (HVAC) systems, which typically account for 40%-50% of a building's energy use, are prime targets for energy savings. Intelligent control of HVAC temperature through the exploitation of HVAC load flexibility brings significant potential to reduce energy consumption and electricity expenses. The nonlinear models of HVAC systems challenge traditional control methods, while the uncertainty introduced by HVAC load flexibility complicates distributed energy resource (DER) management using conventional optimal dispatch techniques. In response to these challenges, we propose a hierarchical multi-agent deep reinforcement learning (DRL) approach. The lower-level agents focus on balancing comfort and energy conservation, while the upper-level DRL agents optimize the use of DERs to reduce peak demand based on the control outcomes of the HVAC by the lower-level agents. Here, in the upper-level agents, we incorporate a multi-agent structure based on ensemble learning, which acts based on historical and current data without relying on precise load forecasting to address the delayed rewarding issue in DRL. This allows for the effective reduction of energy costs. The proposed method is tested using a real-world microgrid comprising 413 buildings in Southern California, and the results demonstrate that our approach can significantly reduce overall electricity bills while ensuring the comfort of consumers and residents.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Panel Session 81: Engaging on Safety at the Work Face - Workers, Front Line Managers, and Subcontractors

This panel focuses on engaging on safety at the work face, with the people who are there every day. This panel will discuss management approaches deployed to directly engage internal and subcontracted workers that have delivered measurable improvements in safety performance and culture. The panelists will share what they did that worked and their perspectives on why. About 24 to 30 people were in attendance. All statements below are paraphrased by the panel reporter and should not be considered direct quotes by the panelists. Presentations proposed include: 1 - Engaging on Safety at the Work Face: Workers, Front Line Managers, and Subcontractors (Jan Preston, Fluor Corporation (USA)); 2 - Responsibility for Safety: Workers and Line Management Joining Together to Improve Performance (Cynthia Williams, Canadian Nuclear Laboratories (Canada)); 3 - Worker Involvement: Trust and the Processing of the Remediated Nitrate Salts (David Funk, Los Alamos National Laboratory (USA)); 4 - Safety Culture: How Employee Engagement is Transforming the Paducah Site (Myrna Espinosa Redfield, Four Rivers Nuclear Partnership (USA)); 5 - Hazard Identification and Control: Subcontractor Performance, Oversight, and Continuous Improvement (Clint Wolfley, URS/CH2M Oak Ridge - UCOR (USA)); 6 - Managing Safety Performance Through Change (Alice Doswell, Fluor (USA))

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Authentication of smart grid communications using quantum key distribution

Smart grid solutions enable utilities and customers to better monitor and control energy use via information and communications technology. Information technology is intended to improve the future electric grid’s reliability, efficiency, and sustainability by implementing advanced monitoring and control systems. However, leveraging modern communications systems also makes the grid vulnerable to cyberattacks. Here we report the first use of quantum key distribution (QKD) keys in the authentication of smart grid communications. In particular, we make such demonstration on a deployed electric utility fiber network. The developed method was prototyped in a software package to manage and utilize cryptographic keys to authenticate machine-to-machine communications used for supervisory control and data acquisition (SCADA). This demonstration showcases the feasibility of using QKD to improve the security of critical infrastructure, including future distributed energy resources (DERs), such as energy storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Completing the Cleanup of the US Department of Energy's East Tennessee Technology Park - Four Years Early - 16067

On August 1, 2011, URS - CH2M Oak Ridge LLC (UCOR) began its $2.6 billion cleanup of the East Tennessee Technology Park (ETTP), the former Oak Ridge Gaseous Diffusion Plant, located on the U.S. Department of Energy's (DOE) Oak Ridge Reservation (ORR) in Tennessee. Under the contract, the scope of work to be completed includes demolition of all gaseous diffusion buildings, namely K-25, K-31 and K-27, as well as other facilities such as the Toxic Substance Control Act (TSCA) Incinerator, the K-1200 Centrifuge Complex and the K-1037 Barrier Plant. Additionally, UCOR will remove contaminated soils and treat contaminated groundwater. Waste generated by these cleanup activities will be disposed at onsite as well as offsite facilities. UCOR will also continue to manage hundreds of the DOE Oak Ridge Office of Environmental Management (OREM)-owned facilities across the ORR. Due largely to funding challenges early in the project, the DOE estimated in their October 2013 Program Plan 2014-2024 that ETTP cleanup would not be achieved until 2024, four years later than originally scheduled in UCOR's contract with the DOE. In November 2014, the DOE Manager for OREM, Susan Cange, publicly shared her 'vision' for ETTP cleanup by 2020, four years earlier than the DOE's current plan. As part of Vision 2020, all gaseous diffusion buildings would be demolished by the end of 2016. In response to Ms. Cange's vision, UCOR published a Strategic Plan describing how ETTP could be cleaned up by 2020, provided that a number of funding and programmatic and technical challenges could be overcome. UCOR is in the midst of implementing its Strategic Plan, and progress is being made to that end. Since assuming its responsibilities as the ETTP cleanup contractor, UCOR has completed its life-cycle Performance Measurement Baseline (PMB); received its Earned Value Management System (EVMS) certification; completed the D and D of the 44-acre K-25 and 17-acre K-31 gaseous diffusion buildings; completed the K-1070- B Burial Ground remediation project; completed RCRA closure of the TSCA Incinerator; and disposed of more than 541,411 cubic yards of cleanup waste while managing the on-site Environmental Management Waste Management Facility (EMWMF). In 2015, UCOR achieved safety 'Star Status' under the DOE's Voluntary Protection Program (VPP); completed the demolition of the K-31 gaseous diffusion building; advanced the characterization and deactivation of the K-27 gaseous diffusion building, readying the building for the start of demolition in 2016; and began characterization activities in the K-1037 Barrier Plant as well as a number of facilities in the Poplar Creek Area of the ETTP Site. Project performance through December 31, 2015, is as follows: Cost Performance Index - 1.12, Schedule Performance Index - 1.02. Since safety is the foundation of all cleanup work, UCOR's safety record goes hand-in-hand with its project performance. Through calendar year 2015, UCOR's recordable injury rate was 0.94 occurrences per 200,000 work hours, and the day away case rate was 0.31. These rates are both below the DOE and UCOR goals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Power-to-Gas Systems for Active Load Management at EV Charging Sites with High DER Penetration

Intermittent renewable systems and increasing electric vehicle (EV) penetrations increase load intermittency—and will require expensive distribution system infrastructure upgrades. Power-to-gas (P2G) systems are highly controllable loads that can be modulated to regulate the net load behind the meter. In this work, we present an active load management approach using P2G systems to regulate the net load for an EV charging station with high penetrations of renewable generation. The system also validates the feasibility of the proposed approach using a 750-kW electrolyzer operated with the distribution system in a real-time power-hardware-in-the-loop test. Finally, we evaluate the impact of the size of the P2G system on its ability to regulate the net load.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

The ECP SICM project: Managing complex memory hierarchies for exascale applications

The Exascale Computing Project (ECP)’s Simplified Interface to Complex Memories (SICM) effort focuses on developing universal interfaces for discovering, managing, and sharing data across complex memory hierarchies. These facilitate the exploitation of emerging memory technologies and support precise control over their various trade-offs such as high-bandwidth versus low-latency, persistent versus ephemeral, high-capacity versus low-capacity, and near-CPU versus near-GPU. SICM comprises three interrelated components: a low-level interface, a high-level interface, and a persistent-heap interface. The low-level SICM interface is intended for system and run-time developers as well as expert application developers who prefer full control of the memory objects used within their application. The high-level SICM interface builds upon the low-level interface, employing application-level profiling and analysis to optimize data management for complex memory hierarchies. The persistent-heap interface provides applications with a persistent memory allocator that can allocate custom C++ data structures in both block-storage and byte-addressable persistent memories.

97 MATHEMATICS AND COMPUTING↗

Safety-assured, real-time neural active fault management for resilient microgrids integration

Federated-learning-based active fault management (AFM) is devised to achieve real-time safety assurance for microgrids and the main grid during faults. AFM was originally formulated as a distributed optimization problem. Here, federated learning is used to train each microgrid's network with training data achieved from distributed optimization. The main contribution of this work is to replace the optimization-based AFM control algorithm with a learning-based AFM control algorithm. The replacement transfers computation from online to offline. With this replacement, the control algorithm can meet real-time requirements for a system with dozens of microgrids. By contrast, distributed-optimization-based fault management can output reference values fast enough for a system with several microgrids. More microgrids, however, lead to more computation time with optimization-based method. Distributed-optimization-based fault management would fail real-time requirements for a system with dozens of microgrids. Controller hardware-in-the-loop real-time simulations demonstrate that learning-based AFM can output reference values within 10 ms irrespective of the number of microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Demonstration of automated price response in large customers in New York City using Auto-DR and OpenADR

Demand response (DR) – allowing customers to respond to reliability requests and market prices by changing electricity use from their normal consumption pattern – continues to be seen as an attractive means of demand-side management and a fundamental smart-grid improvement that links supply and demand. From October 2011 to December 2013, the Demand Response Research Center at Lawrence Berkeley National Laboratory, the New York State Energy Research and Development Authority, and partners Honeywell and Akuacom, have conducted a demonstration project enabling Automated Demand Response (Auto-DR) in large commercial buildings located in New York City using Open Automated Demand Response (OpenADR) communication protocols. In particular, this project focuses on demonstrating how the OpenADR platform, enabled by Akuacom, can automate and simplify interactions between buildings and various stakeholders in New York State and enable the automation of customers’ price response to yield bill savings under dynamic pricing. In this paper, the cost control opportunities under day-ahead hourly pricing and Auto-DR control strategies are presented for four demonstration buildings; present the breakdown of Auto-DR enablement costs; summarize the field test results and their load impact; and show potential bill savings by enabling automated price response under Consolidated Edison’s Mandatory Hourly Pricing (MHP) tariff. For one of the sites, the potential bill savings at the site’s current retail rate are shown. Facility managers were given granular equipment-level opt-out capability to ensure full control of the sites during the Auto-DR implementation. The expected bill savings ranged from 1.1% to 8.0% of the total MHP bill. The automation and enablement costs ranged from $70 to $725 per kW shed. The results show that OpenADR can facilitate the automation of price response, deliver savings to the customers and opt-out capability of the implementation retains control of the sites by facility managers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Cybersecurity Threat Profile for a Connected Lighting System

In anticipation of improved energy performance and cost savings, cities and building owners are increasingly considering “smart lighting initiatives” that aim to convert their collection of simple luminaires (i.e., lighting fixtures) into an intelligent connected lighting system (CLS) capable of remotely monitoring energy consumption and fault conditions, and possibly implementing adaptive lighting schemes. The U.S. Department of Energy (DOE) has set an national goal of tripling the energy efficiency and demand flexibility of the buildings sector by 2030, relative to 2020 levels 1. It is forecast that connected lighting systems can contribute to that goal by delivering 125 TWh of annual energy savings by 2035 2, equivalent to the annual output of 50 typical (500 MW) power plants. However, these energy savings and the DOE goal are put at significant risk if connected technologies are not adopted due to real or perceived cybersecurity concerns. Connected IoT devices such as these have historically been rife with vulnerabilities which sometimes put security considerations secondary to functionality and operability. What are the cybersecurity threats that will impact these systems, as formerly banal luminaires transition into intelligent connected devices that collect information about themselves, their surrounding environment, and possibly us? In this paper we analyze a threat profile performed on a fault-detection use case for streetlights. A threat profile establishes security requirements, justifies security measures, yields actionable controls, and effectively communicates risk to stakeholders. This effort provides critical information for making threat-based decisions to increase security at a reasonable cost, and can effectively be used by development teams, software architects, and managers to make cybersecurity a part of their ongoing culture of awareness, training, and prevention. This leads to more secure systems and better-understood security. On-premise, cloud, and hybrid architectures with different authentication mechanisms were modeled and later categorized using the Microsoft STRIDE framework. An analysis of the recommended controls for each threat was performed to determine which controls could and should be put in place by manufacturers or third-party suppliers, and which controls need to be left up the end-user to implement. Fifty-seven threats were identified. Among our key findings: (1) 65% (37/57) of the threats did not involve the luminaires, but rather the other components needed to communicate with and manage them; (2) 63% (36/57) of the threats could have been mitigated through manufacturer-implemented defensive techniques or “controls”; and (3) 23% (13/57) of the threats were dependent on the network configuration. Recommendations based on the results of this work are made to key stakeholder groups. Notably, lighting technology developers are advised to address all threats that can be reasonably controlled with baked-in technology solutions (e.g., encryption or authentication controls), and employ some form of secure supply chain management and tracking where other parts (e.g., sensors, microprocessors) of a luminaire must also be built and manufactured with the proper security controls in place. Developers should also review threats involving assets not developed in-house to understand how connectivity with other devices will affect their product during system operation and determine if a compensating control for a defense-in-depth strategy will be needed. Finally, those interested in deploying CLS should compare the differences between cloud and on-premise models to determine which is more suitable for their needs and the abilities of their security team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and implementation of dynamic I/O control scheme for large scale distributed file systems

In this paper, we have analyzed the input/output (I/O) activities of Cori, which is a high-performance computing system at the National Energy Research Scientific Computing Center at Lawrence Berkeley National Laboratory. Our analysis results indicate that most users do not adjust storage configurations but rather use the default settings. In addition, owing to the interference from many applications running simultaneously, the performance varies based on the system status. To configure file systems autonomously in complex environments, we developed DCA-IO, a dynamic distributed file system configuration adjustment algorithm that utilizes the system log information to adjust storage configurations automatically. Our scheme aims to improve the application performance and avoid interference from other applications without user intervention. Moreover, DCA-IO uses the existing system logs and does not require code modifications, an additional library, or user intervention. To demonstrate the effectiveness of DCA-IO, we performed experiments using I/O kernels of real applications in both an isolated small-sized Lustre environment and Cori. Our experimental results shows that our scheme can improve the performance of HPC applications by up to 263% with the default Lustre configuration.

97 MATHEMATICS AND COMPUTING↗

Challenges and Opportunities of Integrating Electric Vehicles in Electricity Distribution Systems

Increased charging needs from widespread adoption of battery electric vehicles (EVs) will impact electricity demand. This will likely require a combination of potentially costly distribution infrastructure upgrades and synergistic grid-transportation solutions such as managed charging and strategic charger placement. Fully implementing such strategic planning and control methods - including business models and mechanisms to engage and compensate consumers - can minimize or even eliminate required grid upgrades. Moreover, there are also opportunities for EV charging to support the grid by helping solve existing and emerging distribution system challenges associated with increasing distributed energy resources (DERs) such as solar generation and battery energy storage. This paper reviews the potential impacts of EV charging on electricity distribution systems and describes methods from the literature to efficiently integrate EVs into distribution systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Inhibitory effect of celastrol on adipogenic differentiation of human adipose-derived stem cells

Highlights: • Celastrol has therapeutic potential against obesity- and aging-related diseases. • Anti-adipogenic effect of celatrol in human ADSCs depended on dose and duration. • Celatrol inhibited adipogenesis in human ADSCs by regulating PPARG and CEBPA. • Celastrol inhibited adipogenesis in hADSCs derived from 12 donors with various ages. • Celastrol also inhibited osteogenic and chondrogenic differentiation in hADSCs. Control of adipogenesis in mesenchymal stem cells (MSCs) offers enormous potential for management of obesity- and aging-related diseases. Celastrol, the traditional Chinese medicine extracted from Tripterygium wilfordi, exhibits anti-obesity effects in in vitro and in vivo murine models. This study describes how celastrol affects multilineage differentiation potential of human adipose-derived stem cells (hADSCs). We performed in vitro adipogenic differentiation of hADSCs and investigated how celastrol-induced lipid accumulation and expression of adipocyte differentiation markers varied with dose, duration, and donor age. In addition, we assessed the effect of celastrol on osteogenic and chondrogenic differentiation of hADSCs. During adipogenic induction of hADSCs, the inhibitory effect of celastrol on lipid accumulation and adipogenesis depended on dose, duration, time of administration, and individual donor. Inhibition was mediated by proliferator-activated receptor-γ (PPARG) and CCAAT/enhancer-binding protein alpha (CEBPA). Celastrol also suppressed differentiation of hADSCs into the osteogenic and chondrogenic lineages. Celastrol plays a regulatory role in multilineage differentiation of human MSCs. Our findings provide important insights regarding management of obesity and stem cell therapy.

60 APPLIED LIFE SCIENCES↗