Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

High-Performance Computing Based EMT Simulation: Power Grid with IBRs

Electromagnetic transient (EMT) simulation of power grids with high-fidelity models of inverter-based resources (IBRs) is time-consuming and difficult to scale. The necessity for high-fidelity models of IBRs that incorporate the dynamics of individual inverters within IBRs has been showcased in recent studies. These studies focused on events with partial power reduction in each IBR during a transmission line fault in the power grid. These types of events have been documented in multiple North American Electric Reliability Council (NERC) reports in the past decade. It is imperative then to find solutions to speed-up EMT simulations and scale the size of the region with IBRs studied in EMT simulations. In this paper, a combination of numerical simulation algorithms with high-performance computing techniques are employed in discretization and linear solvers employed in the proposed RE-INTEGRATE EMT simulation platform for power grid with IBRs. For ease of scalability, modular and object-oriented programming is used as these techniques are implemented. Additionally, automation software is developed to convert legacy software codes to the proposed RE-INTEGRATE EMT simulation platform. Thereafter, this platform is evaluated on multi-core central processing units (CPUs). Finally, scale-up tests are performed to showcase the scalability that is possible.

Marthi, Phani Ratna Vanamali [ORNL] (ORCID:0000000↗

CodEx: A Modular Framework for Joint Temporal De-Blurring and Tomographic Reconstruction

In many computed tomography (CT) imaging applications, it is important to rapidly collect data from an object that is moving or changing with time. Tomographic acquisition is generally assumed to be step-and-shoot, where the object is rotated to each desired angle, and a view is taken. However, step-and-shoot acquisition is slow and can waste photons, so in practice fly-scanning is done where the object is continuously rotated while collecting data. However, this can result in motion-blurred views and consequently reconstructions with severe motion artifacts. In this paper, we introduce CodEx, a modular framework for joint de-blurring and tomographic reconstruction that can effectively invert the motion blur introduced in sparse view fly-scanning. The method is a synergistic combination of a novel acquisition method with a novel non-convex Bayesian reconstruction algorithm. CodEx works by encoding the acquisition with a known binary code that the reconstruction algorithm then inverts. Using a well chosen binary code to encode the measurements can improve the accuracy of the inversion process. The CodEx reconstruction method uses the alternating direction method of multipliers (ADMM) to split the inverse problem into iterative deblurring and reconstruction sub-problems, making reconstruction practical to implement. Here we present reconstruction results on both simulated and binned experimental data to demonstrate the effectiveness of our method.

42 ENGINEERING↗

FIDVR Capability of Hybrid Grid-Forming PV Power Plants During Feeder Restoration

Grid-forming inverters must optimally transfer power from dc-coupled photovoltaic arrays and batteries into an ac grid. Further, they must be able to restore single-phase induction motors (SPIMs) and withstand fault-induced delayed voltage-recovery (FIDVR) events. These resilience and reliability challenges are addressed here by: (i) engineering a controller to optimally operate dc-coupled hybrid resources; (ii) modeling residential air-conditioning compressors for restoration/FIDVR studies; and (iii) analyzing SPIM thermal-relay performance under limited inverter currents and designing an electronic protection for stalled SPIMs. Furthermore, these contributions are demonstrated via electromagnetic-transient simulations and can be helpful to understand recommendations by the North American Electric Reliability Corporation.

14 SOLAR ENERGY↗

Comparative Analysis of Pendulum and Flywheel Power Take-Off Mechanisms for Wave Energy Conversion

Here, this study compares three power-take-off (PTO) mechanisms for wave energy converters—a flywheel -type pitch resonator and two pendulum variants (normal and inverted)—all designed to fit within a fixed envelope. Performance is assessed via linear frequency-domain models and bi-conjugate impedance matching under a representative sea state. The inverted-pendulum PTO achieves 27.9% of the incident wave energy, versus 16.5% for the normal pendulum and 4.2% for the flywheel—that is, 6.6 × and 3.9 × improvements, respectively. These gains arise because pendulum-based systems generate higher torque for a given buoy motion and maintain impedance matching across a wider frequency band. Parametric studies of mass, pendulum arm length, spring stiffness, generator friction, and motor constant quantify the impact of key design choices on power output. By locating the pendulum pivot near the buoy's center of gravity and positioning the center of rotation below the COG, surge–pitch coupling is improved and energy transfer is further boosted.

Keow, Alicia Li Jen [Sandia National Laboratories ↗

Measurement of DC Arc-Flash Incident Energy in Large-Scale Photovoltaic Plants: A Basis for Standardization

The deployment of high-power dc equipment is increasing in solar photovoltaic (PV) plants, but very few studies have quantified dc arc-flash risks. Currently, PV plant owners and operators rely on theoretical, simplified models, such as those in NFPA-70E and other publications, for the assessment of risk associated with dc arc-flash. Here, this article presents an overview of arc-flash risks in a PV system based on a series of field experiments based on IEEE-1584 in two large-scale ground-mounted PV plants. The experiments include various high-power dc equipment of a PV plant, such as central inverters, combiner boxes, recombiner boxes, string inverters, and multiple configurations of electrodes in a 20-in calibration cube. The study reveals that none of the available dc arc-flash models are applicable for a PV plant. This work is an important first step toward developing an improved model that more accurately assesses dc arc-flash risk in a PV plant.

14 SOLAR ENERGY↗

Predictive Coordinated and Cooperative Voltage Control for Systems With High Penetration of PV

In this paper, we propose a predictive coordinated and cooperative voltage control method in a power distribution system with high penetration of photovoltaic (PV) units. First, an integrated coordinated voltage control of voltage regulators (VRs) tap positions and cooperative distributed control of the reactive power output from PV inverters are used to maintain system voltages within an appropriate bandwidth. Next, solar power forecasting is applied to predict voltage changes, which are used to set the VR tap positions and capacitor switch status to prevent large voltage fluctuations. The fine tuning of voltage adjustment is then achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on a modified IEEE 123-node test feeder with high penetration of PVs using real measurement data and compared with the base case. Simulation results demonstrate the effectiveness of the integrated voltage control, as well as the enhancement from the predictive control through solar power forecasting-enabled voltage change estimates. Comparison to previous work in the literature shows significant improvement in terms of voltage deviation and reduction in excessive tap changes.

14 SOLAR ENERGY↗

Operation of Dual-T-Type Modular Multilevel Converter for Uninterrupted Power Supply Under Bridge Failures

Dual-T-type modular multilevel converter (DTMMC) is an alternative to the existing uninterrupted power supply (UPS) due to its advantage in flexible leg reusing, multiple power ports, and high operating efficiency. Here, in this article, a DTMMC-UPS, which has series configurations on both input/output ac sides, obtains high-voltage grid/load accessing interfaces is presented. In the described system, the fact that copies of T-type legs are employed makes semiconductor failure common to happen. Moreover, both the coupling between rectifier and inverter conversions and the confliction between intercell and inner-cell voltage balancing make fault-tolerant control a tough issue. In this article, the switch fault types are first clarified and diagnosed by the different impacts on normal operation. An improved voltage vector modulation is then deduced to facilitate the planning of proper primary switching patterns, to achieve rectifier side normal operation. The secondary alternated level-shifted pulsed-width modulation (LS-PWM) is also modified to achieve inverter side normal operation. The experiment results are supplied to verify the validity of the modulation-coordinated fault toleration strategy.

42 ENGINEERING↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Voltage positioning using co-optimization of controllable grid assets in radial networks

With increasing penetration of solar PV, some distribution feeders are experiencing highly variable net-load flows and even reverse flows. To optimize distribution systems under such conditions, the scheduling of mechanical devices, such as OLTCs and capacitor banks, needs to take into account forecasted solar PV and actual grid conditions. However, these legacy switching assets are operated on a daily or hourly timescale, due to the wear and tear associated with mechanical switching, which makes them unsuitable for real-time control. Therefore, there is a natural timescale- separation between these slower mechanical assets and the responsive nature of inverter-based resources. In this paper, we present a network admissible convex formulation for holistically scheduling controllable grid assets to position voltage optimally against solar PV. An optimal hourly schedule is presented that utilizes mechanical resources to position the predicted voltages close to nominal values, while minimizing the use of inverter-based resources (i.e., DERs), making them available for control at a faster time-scale (after the uncertainty reveals itself). A convex, inner approximation of the OPF problem is adapted to a mixed-integer linear program that minimizes voltage deviations from nominal (i.e., maximizes voltage margins). Here, the resulting OPF solution respects all the network constraints and is, hence, robust against modeling simplifications. Simulation based analysis on IEEE distribution feeders validates the approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generalized Analytical Estimation of Sensitivity Matrices in Unbalanced Distribution Networks

Fast and accurate estimation of sensitivity matrices is significant for the enhancement of distribution system modeling and automation. Analytical estimations have mainly focused on voltage magnitude sensitivity to active/reactive power injections for unbalanced networks with Wye-connected loads and neglecting DERs' smart inverter functionality. Hence, this paper enhances the scope of analytical estimation of sensitivity matrices for unbalanced networks with 1- Φ, 2- Φ, and 3- Φ Delta/Wye-connected loads, DERs with smart inverter functionality, and substation/line step-voltage regulators (SVR). A composite bus model comprising of DER, Delta- and Wye-connected load is proposed to represent a generic distribution bus, which can be simplified to load, PV, or voltage-controlled bus as required. Furthermore, the proposed matrix-based analytical method consolidates voltage magnitude and angle sensitivity to active/reactive power injection and tap-position of all SVRs into a single algorithm. Extensive case studies on IEEE and EPRI networks show the accuracy and wide scope of the proposed algorithm compared to the existing benchmark method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part I: Solution Design

This work is the first of a two-part series that develops and experimentally demonstrates a first-of-its-kind hierarchical control solution for optimally dispatching thousands of deferrable loads and distributed energy resources (DERs) across a distribution feeder to provide fast frequency response (FFR) within 500 ms to the bulk power system. This approach rapidly coordinates resources online after a frequency event occurs, allowing fast-changing, behind-the-meter (BTM) resources to be incorporated and aggregate FFR power set points to be achieved more quickly and accurately than existing approaches. We also present a solution for determining the optimal amount of headroom to operate solar inverters with to minimize opportunity cost while ensuring the FFR response viability of a building with the inverter and deferrable loads. In Part I, we develop practical algorithms for fast, cost-based optimal dispatch at multiple aggregation scales (single building, multiple buildings, and full distribution feeder), establish their optimality, and demonstrate via simulation that they are faster than state-of-the-art, coordinated frequency response approaches. In Part II, the entire platform is implemented and experimentally verified using a unique power hardware-in-the-loop demonstration, including more than 100 powered loads and DERs connected to a real-world distribution network model and over 10,000 net-load resources dispatched.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of an Encoding Method on an Co-simulation Platform for Mitigating the Impact of Unreliable Communication

This report presents a hardware-in-the-loop (HIL) based modeling approach for simulating impacts of unreliable communication on the performance of centralized volt-var control and for developing an encoding method to mitigate the impacts. First, an asynchronous real-time HIL simulation platform is introduced to enable multi-rate co-simulation of a distribution system with many inverter-based distributed energy resources (DERs). The distribution system is modeled by milliseconds phasor-based models and the DERs are modeled by micro-seconds power electronic models. Communication connections between a centralized volt-var controller (modeled externally to the HIL testbed) and smart inverters are built by implementing Modbus links and the Long Term Evolution network. On this co-simulation platform, an enhanced, augmented Lagrangian multiplier based encoded data recovery (EALM-EDR) algorithm for mitigating the impact of unreliable communication is developed and validated. Simulation results demonstrate the efficacy of using the HIL-based co-simulation platform as a power grid digital twin for developing algorithms that coordinate a large number of heterogeneous control systems through wired and wireless communication links.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Affinely Adjustable Robust Volt/VAr Control

Recent years have seen the increasing proliferation of distributed energy resources with intermittent power outputs, posing new challenges to the voltage management in distribution networks. To this end, this paper proposes a data-driven affinely adjustable robust Volt/VAr control (AARVVC) scheme, which modulates the smart inverter’s reactive power in an affine function of its active power, based on the voltage sensitivities with respect to real/reactive power injections. To achieve a fast and accurate estimation of voltage sensitivities, we propose a data-driven method based on deep neural network (DNN), together with a rule-based bus-selection process using the bidirectional search method. Our method only uses the operating statuses of selected buses as inputs to DNN, thus significantly improving the training efficiency and reducing information redundancy. Finally, a distributed consensus-based solution, based on the alternating direction method of multipliers (ADMM), for the AARVVC is applied to decide the inverter’s reactive power adjustment rule with respect to its active power. Only limited information exchange is required between each local agent and the central agent to obtain the slope of the reactive power adjustment rule, and there is no need for the central agent to solve any (sub)optimization problems. Finally, numerical results on the modified IEEE-123 bus system validate the effectiveness and superiority of the proposed data-driven AARVVC method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Identification of Synchronized Voltage Waveform for Situational Awareness of Low Inertia Systems

Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.

Situational awareness↗

Analysis of 0.1-Hz Var Oscillations in Solar Photovoltaic Power Plants

Oscillations with very low frequency at 0.1 Hz, have been observed in voltage and var in practical solar photovoltaic (PV) systems when power exporting ramps up to a certain level. Here, this letter provides an explanation on the formation of 0.1-Hz oscillations and identifies three critical factors that lead to the oscillations: communication delay between the plant-level control and the inverter-level control, high volt/var sensitivity at a high power exporting level, and the volt-var feedback system consisting of the plant control, inverter control and the grid impact. Furthermore, a critical feature of the 0.1-Hz oscillation is also explained: why oscillations appear only in voltage and var, but not in real power.

14 SOLAR ENERGY↗

Data-Driven Mean-Corrected Recursive Estimation-Based Optimal DER Dispatch for Distribution System Voltage Control

Recent advances in smart inverters offer opportunities to mitigate adverse grid impacts caused by high penetrations of distributed photovoltaics (PV) in distribution grids, such as voltage violations. Here, this paper proposes a novel measurement-driven optimal power flow (OPF)-based distributed energy resource management system (DERMS) voltage regulation via recursive sensitivity estimation informed coordinated control of distributed PV inverters. The proposed approach leverages available grid and controllable DER measurements, eliminating reliance on system model information while being adaptive and robust to volatile operating conditions. A mean-corrected recursive ridge regression (MCRRR) algorithm is proposed for sensitivity estimation, continuously refining the sensitivity model through a closed-form solution. It effectively manages varying grid operating conditions, such as changes in power injections and topology reconfiguration, to facilitate a time-varying update of the Load Sensitivity Factors (LSF). The proposed approach is formulated as a linear programming (LP) problem and is thus scalable to larger-scale distribution systems. Its effectiveness and efficiency are demonstrated on a realistic distribution feeder with high PV penetrations in Southern California, USA.

14 SOLAR ENERGY↗

Automotive Silicon Carbide Power Module Cooling With A Novel Modular Manifold And Embedded Heat Sink

The next generation of integrated power electronics packages will implement wide-bandgap devices with ultrahigh device heat fluxes. Although jet impingement has received attention for power electronics thermal management, it is not used in commercial electric vehicles (EVs) because of the associated pressure drop and reliability concerns. Here, in this paper, we present a modular thermal management system designed for automotive power electronics. The system achieves superior thermal performance to benchmarked EVs, while adhering to reliability standards and with low pumping power. The system utilizes a low-cost and lightweight plastic manifold to generate jets over an optimized heat sink, which is embedded in the direct-bonded-copper (DBC) substrate. The embedded heat sink concept leverages additive manufacturing to add elliptical pin fins to the DBC substrate. The heat sink geometry is optimized for submerged jet impingement using a unit-cell model and an exhaustive search algorithm. The model predictions are validated using unit-cell experiments. A full-scale power module model is then used to compare the DBC-embedded heat sink against direct DBC cooling and baseplate-integrated heat sinks for single-sided (SS) and double-sided (DS) cooling concepts. Using the SS and DS DBC-embedded cooling concepts, the models predict a thermal resistance that represents a reduction of 75% and 85% compared to the 2015 BMW i3, respectively, for the same water-ethylene glycol inverter flow rate. We have shown that an inverter with a 100-kilo-Watt-per-liter power density is achievable with the proposed design.

33 ADVANCED PROPULSION SYSTEMS↗