At least 1,567 records · Page 87

Preparation of 241 Am/ 243 Am gravimetric mixtures and development of Am isotopic and assay measurement techniques using thermal ionization mass spectrometry

Three gravimetric mixtures with 241 Am/ 243 Am isotope ratios at nominally 1:1, 20:1, and 200:1 were prepared for calibration of the thermal ionization mass spectrometer instruments used for americium isotopic and assay measurements by isotope dilution mass spectrometry. The total evaporation analytical technique was developed for high-accuracy and precision measurements of Am isotopic ratios. The technique was also applied to Am assay measurements using isotope dilution mass spectrometry. The Am isotope ratio and assay measurement techniques were utilized to characterize batches of americium oxide separated from plutonium materials in storage at Los Alamos National Laboratory in support of commercial use of 241 AmO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Pu emission with solution-loaded laser ablation modified sources (SLLAMS) for thermal ionization mass spectrometry

This study presents a new approach to filament modification by laser ablation for analysis of femtograms of plutonium (Pu) by thermal ionization mass spectrometry (TIMS). This method simplifies the often rigorous and labor-intensive sample loading necessary for low-level analyses by TIMS with solution-loaded laser ablation modified sources (SLLAMS). By applying a para-film coating to the surface of the filament and then ablating through the film to reveal metal beneath, a point source is created. A solution containing ppt-levels of Pu can then be applied over the ablated region, dried slowly into the crater, and then carburized. All analyses were made by multiple ion counting system of a Nu Instruments TIMS. Furthermore, we report errors of 10% 2σ for 240 Pu/ 239 Pu of CRM-137 samples totaling 5 – 7 femtograms (fg; 1E-15 g) with an average sample utilization efficiency of 1.3%. Results from SLLAMS demonstrate an improvement in precision, accuracy and ease of use over resin bead loads.

47 OTHER INSTRUMENTATION↗

Inhibition of Bcl-2/xl With ABT-263 Selectively Kills Senescent Type II Pneumocytes and Reverses Persistent Pulmonary Fibrosis Induced by Ionizing Radiation in Mice

Purpose: Ionizing radiation (IR)–induced pulmonary fibrosis (PF) is an irreversible and severe late effect of thoracic radiation therapy. The goal of this study was to determine whether clearance of senescent cells with ABT-263, a senolytic drug that can selectively kill senescent cells, can reverse PF. Methods and Materials: C57BL/6J mice were exposed to a single dose of 17 Gy on the right side of the thorax. Sixteen weeks after IR, they were treated with 2 cycles of vehicle or ABT-263 (50 mg/kg per day for 5 days per cycle) by gavage. The effects of ABT-263 on IR-induced increases in senescent cells; elevation in the expression of selective inflammatory cytokines, matrix metalloproteinases, and tissue inhibitors of matrix metalloproteinases; and the severity of the tissue injury and fibrosis in the irradiated lungs were evaluated 3 weeks after the last treatment, in comparison with the changes observed in the irradiated lungs before treatment or after vehicle treatment. Results: At 16 weeks after exposure of C57BL/6 mice to a single dose of 17 Gy, thoracic irradiation resulted in persistent PF associated with a significant increase in senescent cells. Treatment of the irradiated mice with ABT-263 after persistent PF had developed reduced senescent cells and reversed the disease. Conclusions: To our knowledge, this is the first study to demonstrate that PF can be reversed by a senolytic drug such as ABT-263 after it becomes a progressive disease. Therefore, ABT-263 has the potential to be developed as a new treatment for PF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous Targeting of RSK and AKT Efficiently Inhibits YB-1-Mediated Repair of Ionizing Radiation-Induced DNA Double-Strand Breaks in Breast Cancer Cells

Y-box binding protein 1 (YB-1) overexpression is associated with chemotherapy- and radiation therapy resistance. Ionizing radiation (IR), receptor tyrosine kinase ligands, and mutation in KRAS gene stimulate activation of YB-1. YB-1 accelerates the repair of IR-induced DNA double-strand breaks (DSBs). Ribosomal S6 kinase (RSK) is the main kinase inducing YB-1 phosphorylation. We investigated the impact of RSK targeting on DSB repair and radiosensitivity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of ionizing radiation induced DNA damage response in human adult stem cells and differentiated neurons

Findings of neurodegenerative features associated with human radiosensitive syndromes such as Ataxia telangiectasia suggest that DNA repair efficiency is crucial for maintaining the functional integrity of central nervous system. To gain a better understanding of ionizing radiation (IR) induced DNA damage response in undifferentiated and differentiated neural cell types and to evaluate the role of ATM in DNA double strand break (DSB) repair, an in vitro human neural cell differentiation model system was utilized in this study. As compared to adult stem cells, differentiated neurons displayed an attenuated DSB repair response (as judged by the persistence of 53BP1 foci) after IR exposure and the attenuation was even more pronounced in stem cells and neurons after suppression of ATM (Ataxia Telangiectasia Mutated) gene product suggesting the importance of ATM for an optimal DSB repair efficiency in human neural cell types. In corroboration with an attenuated DNA damage response, a sharp decline in the expression levels of several DSB repair genes was observed in neurons. Furthermore, our results suggest that cellular differentiation modulates the expression of several genes thereby compromising the DSB repair fidelity in post mitotic neurons. Further studies are required to verify whether or not ATM mediated exacerbation of DNA repair deficiency in differentiated neurons leads to neurodegeneration.

53 binding protein 1↗

Investigation of the dynamics of ionization induced injected electrons under the influence of beam loading effects

In laser-driven wakefield, ionization induced injection is an efficient way to inject electrons in the plasma wave. A detailed study on the beam dynamics under the influence of beam loading effects, which can be controlled by the concentration of nitrogen impurity introduced in the hydrogen gas was conducted. For a specific value of this percentage, the final energy of the high-energy electron bunch becomes nearly independent of the trapped positions, thus leading to a small energy dispersion. We also show that the final beam emittance is mainly determined by the injection process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the first 150 mm diameter Cryogenic silicon ionization detectors with contact-free electrodes

Cryogenic semiconductor detectors operated at temperatures below 100 mK are commonly used in particle physics experiments searching for dark matter. The largest such germanium and silicon detectors, with diameters of 100 mm and thickness of 33 mm, are planned for use by the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at SNOLAB, Canada. Still larger individual detectors are being investigated to scale up the sensitive mass of future experiments. We present here the first results of testing two prototype 150 mm diameter silicon ionization detectors. The detectors are 25 mm and 33 mm thick with masses 1.7 and 2.2 times larger than those currently planned for SuperCDMS. These devices were operated with contact-free bias electrodes to minimize leakage currents which currently limit operation at high bias voltages. The results show promise for the use of such technologies in solid state cryogenic detectors.

150 mm↗

Space-charge effects in ionization beam profile monitors

Ionization profile monitors (IPMs) are widely used in accelerators for non-destructive and fast diagnostics of high energy particle beams. At high beam intensities, the space-charge forces make the measured IPM profiles significantly different from those of the beams. We analyze dynamics of the secondaries in IPMs and develop an effective algorithm to reconstruct the beam sizes from the measured IPM profiles. Efficiency of the developed theory is illustrated in application to the Fermilab 8 GeV proton Booster IPMs.

43 PARTICLE ACCELERATORS↗

UV–Visible reflectance of common light reflectors and their degradation after an ionization dose up to 100 Mrad

We report light reflectors are widely used to enhance scintillation light collection. Their enhancement level depends on the reflector’s reflectance at the scintillator’s emission wavelength. We report UV–Visible reflectance spectra, relative to BaSO 4 , for several common reflectors. Also reported is their radiation hardness against an ionization dose up to 100 Mrad. The results of this investigation provide a reference for applications of these reflectors in a severe radiation environment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

K-ras mutation promotes ionizing radiation-induced invasion and migration of lung cancer in part via the Cathepsin L/CUX1 pathway

Highlights: • CTSL has important roles in the regulation of invasion and migration in NSCLC and is promoted by mutated K-ras. • Mutated K-ras and IR-induced CTSL play crucial roles in the EMT in the lung cancer. • The regulatory effects of CTSL on the EMT are attributed to proteolytic processing of the transcription factor CUX1. • Inhibition of CTSL or CUX1 may be a promising therapeutic target. • CTSL is a promising therapeutic target to overcome the invasion and migration induced by IR. K-ras mutation is involved in cancer progression including invasion and migration, but the underlying mechanism is not yet clear. Cathepsin L is a lysosomal cysteine protease and has recently been associated with invasion and migration in human cancers when it is overexpressed. Our recent studies have shown that ionizing radiation (IR) enhanced expression of cathepsin L and increased invasion and migration of tumor cells, but the molecular mechanism is still unclear. In the present study, the effects of K-ras mutation and IR induced invasion and migration of lung cancer as well as the underlying mechanisms were investigated both in vitro and in vivo. Firstly, the levels of cathepsin L and epithelial mesenchymal transition (EMT) marker proteins remarkably changed in A549 (K-ras mutant) after irradiation compared with H1299 (K-ras wild), thereby promoting invasion and migration. Additionally, cathepsin L and its downstream transcription factor CUX1/p110 were increased after irradiation in A549 transfected with CUX1/p200, and the proteolytic processing of CUX1 by cathepsin L was remarkably increased after co-transfection of CUX1/p200 and cathepsin L-lentivirus in H1299. In addition, delivery of a mutant K-ras (V12) into HEK 293 cells stimulated EMT after irradiation due to the accumulation of cathepsin L. Moreover, mutated K-ras was associated with IR-induced cathepsin L and EMT in BALB/c nude mice. Finally, the level of cathepsin L expression was higher in samples carrying a K-ras mutation than in wild-type K-ras samples and the mesenchymal markers were upregulated in the samples of mutant K-ras, whereas the epithelial marker E-cadherin was downregulated in non-small cell lung cancers tissues. In conclusion, the findings demonstrated that mutated K-ras promotes cathepsin L expression and plays a pivotal role in EMT of human lung cancer. The regulatory effect of IR-induced cathepsin L on lung cancer invasion and migration was partially attributed to the Cathepsin L /CUX1-mediated EMT signaling pathway. This study will provide cathepsin L as a potential target for tumor therapy.

60 APPLIED LIFE SCIENCES↗

Effects of ionizing radiation and HPSE1 inhibition on the invasion of oral tongue carcinoma cells on human extracellular matrices in vitro

Highlights: • Myoma-based ECM models are suitable for in vitro chemoradiation assays. • Blocking of HPSE1 activity combined with IR may induce tongue cancer cell invasion. • Low doses of IR may increase MMP expression and invasion in tongue cancer cells. Chemoradiation is an established approach in the treatment of advanced oral tongue squamous cell carcinoma (OTSCC), but therapy may cause severe side-effects due to signal interchanges between carcinoma and the tumour microenvironment (TME). In this study, we examined the potential use of our human 3D myoma disc and Myogel models in in vitro chemoradiation studies by analysing the effects of ionizing radiation (IR) and the combined effect of heparanase I (HPSE1) inhibitors and IR on OTSCC cell proliferation, invasion and MMP-2 and − 9 production. Finally, we analysed the long-term effects of IR by studying clones of previously irradiated and invaded HSC-3 cells. We found that in both human uterine leiomyoma-based extracellular matrix models IR inhibited the invasion of HSC-3 cells, but blocking HPSE1 activity combined with IR induced their invasion. Low doses of IR increased MMP expression and initiated epithelial-mesenchymal transition in cells cultured on myoma discs. We conclude that myoma models offer consistent methods for testing human carcinoma cell invasion and phenotypic changes during chemoradiation treatment. In addition, we showed that IR had long-term effects on MMP-2 and − 9, which might elicit different HSC-3 invasion responses when cells were under the challenge of HPSE1 inhibitors and IR.

60 APPLIED LIFE SCIENCES↗

IFNgamma-inducible CXCL10/CXCR3 axis alters the sensitivity of HEp-2 cells to ionizing radiation

Highlights: • IFNgamma/CXCL10/CXCR3 are necessary for effective IR-induced HEp-2 cell killing. • Local IR showed fewer effects on tumor burden in mice carrying CXCL10-KO xenografts. • Loss of CXCL10 showed blockage in the G0/G1 phase when exposed to a moderate dose of IR. Radiotherapy is a conventional approach for anti-cancer treatment, killing tumor cells through damaging cellular DNA. While increasing studies have demonstrated that tumors generated the tolerance to radiation and tumor immune system was found to be correlated to radiotherapy resistance. Therefore, it is critical to identify potential immune factors associated with the efficacy of radiotherapy. Here in this study, we evaluated the sensitivities of different tumor cells to radiation and determined HEp-2 cells as the radio-resistant tumor cells for further investigation. IFNgamma as a key regulator of host immune response showed the potential to sensitize tumors to ionizing radiation (IR). Besides, IFNgamma-induced CXC chemokine ligand 10 (CXCL10) was found to be necessary for effective IR-induced killing of cultured HEp-2 cells. Increased clonogenic survival was observed in CXCL10-depleted HEp-2 cells and CXCL10-KO cells. Additionally, the loss of CXCL10 in HEp-2 cells showed less progression of the G0/G1 phase to G2/M when exposed to IR (8 Gy). Local IR (20 Gy) to nude mice bearing HEp-2 tumors significantly reduced tumor burden, while fewer effects on tumor burden in mice carrying CXCL10-KO tumors were observed. We furtherly evaluated the possible roles the chemokine receptor CXCR3 plays in mediating the sensitivity of cultured HEp-2 cells to IR. Altered expression of CXCR3 in HEp-2 cells affected IR-induced killing of HEp-2 cells. Our data suggest the IFNgamma-activated CXCL10/CXCR3 axis may contribute to the effective radiation-induced killing of HEp-2 cells in vitro.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

High-Speed Tandem Mass Spectrometric in Situ Imaging by Nanospray Desorption Electrospray Ionization Mass Spectrometry

Nanospray desorption electrospray ionization (nano-DESI) combined with tandem mass spectrometry (MS/MS), high-resolution mass analysis (m/m=17,500 at m/z 200), and rapid spectral acquisition enabled simultaneous imaging and identification of more than 300 molecules from 92 selected m/z windows (± 1 Da) with a spatial resolution of better than 150 um. Uterine sections of implantation sites on day 6 of pregnancy were analyzed in the ambient environment without any sample pre-treatment. MS/MS imaging was performed by scanning the sample under the nano-DESI probe at 10 um/s while acquiring higher-energy collision-induced dissociation (HCD) spectra for a targeted inclusion list of 92 m/z values at a rate of ~6.3 spectra/s. Molecular ions and their corresponding fragments, separated using high-resolution mass analysis, were assigned based on accurate mass measurement. Using this approach, we were able to identify and image both abundant and low-abundance isobaric species within each m/z window. MS/MS analysis enabled efficient separation and identification of isobaric sodium and potassium adducts of phospholipids. Furthermore, we identified several metabolites associated with early pregnancy and obtained the first 2D images of these molecules.

Environmental Molecular Sciences Laboratory↗

Simultaneous Isotopic Analysis of U, Pu, and Am in Spent Nuclear Fuel by Resonance Ionization Mass Spectrometry

Solid samples of spent nuclear fuel were analyzed for actinide isotopic composition by resonance ionization mass spectrometry. Isotopes of U, Pu, and Am were simultaneously quantified using a new method that removes and/or resolves the isobaric interferences at 238 U/ 238 Pu and 241 Pu/ 241 Am without sample preparation other than cutting and mounting small (~10 μm) samples. Trends in burnup and neutron capture product distributions were correlated with the sampling positions inside the reactor. Overall, the results show the skin effect, in which the core and near-edge regions of a fuel pellet exhibit strong differences in actinide concentrations and isotope distributions due to differences in the neutron energy spectra between the pellet rim and the core. While no elemental concentration measurements were made, the ability to measure the 238 Pu/ 239 Pu ratio in the presence of a 7400× excess of 238 U enabled an estimate of the enhancement in Pu concentration due to the skin effect at the rim of the pellet.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Constant-Distance Mode Nanospray Desorption Electrospray Ionization Mass Spectrometry Imaging of Biological Samples with Complex Topography

A new approach for constant distance mode mass spectrometry imaging of biological samples using nanospray desorption electrospray ionization (nano-DESI MSI) was developed by integrating a shear-force probe with nano-DESI probe. The technical concept and basic instrumental setup as well as general operation of the system are described. Mechanical dampening of resonant oscillations due to the presence of shear forces between the probe and the sample surface enables constant-distance imaging mode via a computer controlled closed feedback loop. The capability of simultaneous chemical and topographic imaging of complex biological samples is demonstrated using living Bacillus Subtilis ATCC 49760 colonies on agar plates. The constant-distance mode nano-DESI MSI enabled imaging of many metabolites including non-ribosomal peptides (surfactin, plipastatin and iturin) and iron-bound heme on the surface of living bacterial colonies ranging in diameter from 10 mm to 13 mm with height variations of up to 0.8 mm above the agar plate. Co-registration of ion images to topographic images provided higher-contrast images. Constant-mode nano-DESI MSI is ideally suited for imaging biological samples of complex topography in their native state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculated Ionization Potentials of MO 3 and MO 2 for M = U, Mo, W, and Nd

Here, ionization potentials (IPs) for MO 3 and MO 2 for M = U, Mo, W, and Nd have been predicted using the Feller–Peterson–Dixon (FPD) approach at the coupled cluster CCSD(T)/complete basis set level including additional corrections. The additional corrections are mostly small, with spin-orbit effects contributing less than 0.05 eV, except for NdO 2 where the correction lowers the IP by 0.26 eV. The IPs for UO 3 and UO 2 are calculated to be 9.59 and 6.09 eV, respectively. The calculated IPs for MoO 3 and WO 3 are very similar, 11.13 and 11.11 eV, respectively, and MoO 2 and WO 2 are 8.51 and 8.79 eV, respectively. MoO 2 has a triplet ground state, whereas WO 2 has a singlet ground state. The calculated IP for NdO 2 is 7.90 eV. NdO 3 does not achieve a high +VI formal oxidation state on the lanthanide and has an IP of 7.80 eV. These calculated IPs are expected to have error bars of ±0.04 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Active Thermochemical Tables: The Adiabatic Ionization Energy of Hydrogen Peroxide

The adiabatic ionization energy of hydrogen peroxide (HOOH) is investigated, both by means of theoretical calculations and theoretically-assisted reanalysis of previous experimental data. Values obtained by three different approaches: 10.638 ± 0.012 eV (purely theoretical determination), 10.649 ± 0.005 eV (reanalysis of photoelectron spectrum) and 10.645 ± 0.010 eV (reanalysis of photoionization spectrum) are in excellent mutual agreement. Further refinement of the latter two values to account for asymmetry of the rotational profile of the photoionization origin band leads to a reduction of 0.007 ± 0.006 eV, which tends to bring them into even closer alignment with the purely theoretical value. As a result, detailed analysis of this fundamental quantity by the Active Thermochemical Tables (ATcT) approach, using the present results and extant literature, gives a final estimate of 10.641 ± 0.006 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗