Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERROGATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Development of Quality Control Methods for Robust and Reliable Sensor Design

The successful adoption of additive manufacturing for the rapid prototyping of printed sensors requires the establishment of quantifiable metrics that can interrogate device performance. One measure of performance is the adhesion strength between the substrate and sensor interface, which is critical since the strength of this interface can dictate the accuracy and reliability of the printed sensor. In this work, a non-contact laser-induced spallation technique was used to quantify the adhesion of silver prints on an aluminum alloy substrate. The laser-based method was compared to a standardized pull-off adhesion test, which provided baseline measurements of adhesion strength. The sintering conditions were shown to play an important role in the film-substrate adhesion strength, as well as the cohesion and ductility of the film itself. The methods and results described in this work supports the establishment of process control steps that are necessary for verifying the reliability of printed devices prior to its deployment in critical experiments.

36 MATERIALS SCIENCE↗

Flash Neutron Imaging [Poster]

The NNSS has extensive historical experience with high-fidelity flash neutron imaging which may be applicable to the needs of NA-22. In recent neutron imaging tests, a dense plasma focus (DPF) discharges a capacitor bank across a hydrogen-filled diode to create a flash of fusion neutrons emitted from a point, which can be used for active interrogation. Object inspection may include both radiography transmission imaging as well as emission imaging of the subject via an aperture. A scintillator screen (coupled to a low-Z converter when necessary) converts deposited energy to visible light, which is relayed through optics to an ultra-sensitive visible imager contained in a light-tight box. Flash photon imaging, utilizing bremsstrahlung emission instead of fusion neutrons, is also available and is more mature.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

FY22 Progress Report: SRNL Analysis of ICCWR LCM and WAMS Data for Corrosion and Cracking

Algorithms for machine learning and data analysis for the 3013 Surveillance Program are being developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). To detect the presence of corrosion and cracking, data is collected from large binary files generated by a Laser Confocal Microscope (LCM) or Wide Area 3D Measurement System (WAMS). Software is being developed to use the physical attributes in the data files (e.g., height, color, and grayscale values; all as functions of a location in a plane projection) to detect the presence of surface corrosion and cracking. A user-friendly Matlab Graphical User Interface (GUI) that reads data from either LCM or WAMS files was developed to integrate input data with software developed for processing and evaluation. The GUI can selectively download binary data, interrogate data attributes, label data for training ML algorithms, flag significant features, execute Machine Learning (ML) algorithms, output parameters from trained ML algorithms, report ML model accuracy with respect to labeled data, and generate graphical representations for various analyses. Surface defects can be called out by setting user-specified thresholds, feature based analysis or machine learning algorithms. Enhancements to data labeling capability have been developed to address this essential precursor to application of ML routines. Efficient labeling is particularly important in view of the very large volume of data required to train ML algorithms.

3013 Corrosion↗

Final Report DE-FE0031785 Mohsen Ahmadian, Ph.D. Demonstration of Proof of Concept of a Multiphysics Approach for Real-Time Remote Monitoring of Dynamic Changes in Pressure and Salinity in Hydraulically Fractured Networks

Hydraulic fracturing has evolved into a multistep process with varying flow rates, carrier fluids (e.g., gel or slickwater), proppant loadings, and proppant grain sizes. As a result, primary recovery from a hydraulically fractured tight-oil reservoir is often a tiny fraction of the original oil in place, ranging between 5 and 10%. As stated in the FOA1990, “part of this problem is due to the inability of current well completion processes to effectively stimulate the entire reservoir volume in contact with the wellbore. Innovative technologies are needed that can help improve the effectiveness of reservoir completion methods, maximize stimulated reservoir volumes, and optimize recovery over the entire producing life span of a well”. We first need to enhance the current fracture diagnostic techniques to improve a well-completion design. However, detecting and delineating a subsurface hydraulic fracture is extremely difficult because the induced fracture network is only fractionally propped, and these propped fractures are generally very thin. Microseismic and tiltmeter monitoring techniques can provide information on the fracture extent but provide little or no information on the movement and final distribution of proppant or production fluids. On the other hand, electromagnetic (EM) imaging has shown the capability to monitor proppant distribution throughout the fracture area, especially in the presence of Electrically Active Proppants (EAPs). A previous EM survey of hydraulic fracturing at the Devine Fracture Pilot Site (DFPS) and subsequent EM code developments demonstrated this survey as a robust technique to remotely interrogate the extent of the EAP-filled hydraulic fracture during its propagation. The objectives of the project were threefold: (1) to capitalize on the material properties of an EAP to demonstrate remote monitoring of relative changes in pressure, pressure, and flow that are commonly encountered during production from a hydraulically fractured reservoir; (2) to evaluate EM imaging tools, to achieve Objective 1 in near real-time; and (3) to develop a multi-physics joint inversion approach to precisely predict flow patterns and physiochemical changes within an EAP-filled fracture network. This research project was built upon our previous work at the Devine Test Site managed by the Bureau of Economic Geology (BEG) at The University of Texas at Austin (UT-Austin). It also leveraged a significant investment from the Advanced Energy Consortium (AEC) to address the DOE's interest in subsurface flow, containment, and characterization by multiple signals. This three-year and three-month project succeeded in demonstrating the feasibility of a real-time dynamic fluid flow mapping technique at Technology Readiness Level 5 (TRL5) by utilizing a commercially available surface-based Controlled-Source Electromagnetic (CSEM) method (Objectives 1, 2). We demonstrated that injections into an EAP-filled fracture could be successfully coupled with real-time electric field measurements on the surface, leading to remote monitoring of dynamic changes within the EAP-filled fracture. Furthermore, the observed electric field in our study is influenced by bottomhole pressure, flow rate, and salinity, which is demonstrated by comparing these parameters with the electrical field potentials. EM simulations solely based on assumptions of fracture conductivity changes during injection did not reproduce the whole measured electric field magnitudes. Preliminary estimates showed that including Streaming Potential (SP) in our geophysical model is likely needed to reduce the simulation misfit.

02 PETROLEUM↗

Ice Cryo-Encapsulation Balloon (Project ICEBall) Field Campaign Report

The Ice Cryo-Encapsulation Balloon (ICEBall) field campaign was designed to sample the ice crystals that compose high-altitude cirrus with a passive device. The campaign made use of a new instrument, ICEBall, which is a balloon-borne ice crystal sampling system. The ice crystal sounding system is capable of measuring ice crystal concentration, temperature, atmospheric pressure, ice crystal habit, aerosol particle morphology, and residual composition. The 3-kg instrument is carried upwards at 5 m s-1 by a high-altitude balloon. The instrument can be cut down from the balloon at any altitude up to 20 km, and the apparatus returns to the surface by parachute. Basic measurements such as temperature and pressure are recorded onboard, and high-frequency Global Positioning System (GPS) records altitude and latitude/longitude. Ice crystal concentrations are measured through the use of a high-resolution video camera mounted on the device. Ice crystals are collected through an open aperture leading to insulated collection chambers cooled with dry ice. Upon exiting the top of the cloud system, the chamber aperture is closed, and the ~1 mm3 sample cell is magnetically sealed and isolated at -78 °C, ensuring that ice particles do not sublimate or grow after collection. Once the crystals are returned to the surface, they are double-sealed and immersed at liquid nitrogen temperature in “dry-cryo shippers” before being transported back to the laboratory. Dr. Magee’s laboratory at The College of New Jersey contains a cryo-stage scanning electron microscope (SEM), which was used to interrogate the crystals and aerosol particles. The main purpose of this pilot field campaign was to provide an unprecedented level of detail on the crystal habits and ice surface complexity in mid-latitude cirrus, which may help resolve issues associated with habit identification and classification in cirrus. The ICEBall campaign was originally scheduled to run from March 28 to April 18 of 2021 at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains observatory. The COVID-19 pandemic intervened and caused us to shift the dates of the experiment to October 16-November 6 of 2021. This period is also climatologically favorable for cirrus. The approximately six-month gap between our original field campaign dates and the actual dates afforded us the opportunity to build two new ICEBall payload instruments. These instruments were tested during an August 2021 trip to The College of New Jersey. During this field testing phase, we decided to launch the ICEBall payload upstream from the ARM SGP site with the goal of landing in the vicinity of the site. Our goal was to sample the ice crystals before the cirrus were advected over the remote-sensing instruments at the SGP site. The team assembled for the field campaign consisted of the Principle Investigator (PI) and Co-Principle Investigator (Co-PI) (Drs. Harrington and Magee), The Pennsylvania State University research scientist Dr. Alfred Moyle, and two graduate students (Ms. Marley Majetic and Gwenore Pokrifka). The team operated out of a house rented in Enid, Oklahoma. We successfully sampled seven cirrus cloud systems during the three-week field campaign (October 21, 23-26, 31, and November 1). This was a much higher success rate than either of the PIs anticipated (our goal was closer to sampling three or four cases). The balloon was typically launched from oil pads or farm fields northwest of Enid and the payload was typically retrieved somewhat north of the SGP site. We never landed directly at the SGP site, and so did not need regular access to the SGP facilities. Our greatest concern going into the field campaign was the longer-term storage of crystals in the -196°C cryo dry-shipper dewars and the subsequent transport across the country. We had tested storage and transport prior to the field campaign, but we had never stored crystals for a few weeks nor had we transported the dewars over long distances. To our great relief, the storage and transport worked flawlessly and we were able to image a large number of crystals from six of the seven cases. Working with the staff at the ARM SGP office was excellent. They not only helped us find the sources we needed for helium, liquid nitrogen, and other materials, but also helped with contacts within the Federal Aviation Administration (FAA) and Vance Air Force Base. One goal of our field project was to tie the in situ measurements of ice crystal habits to the radar signatures derived from the Ka-band ARM Zenith-pointing Radar (KAZR). Unfortunately KAZR was down for the duration of our experiment. However, the Ka-band Scanning ARM Cloud Radar (KASACR) was put into vertically pointing mode during the ICEBall campaign and those data, along with Doppler lidar measurements, have proved very useful.

54 ENVIRONMENTAL SCIENCES↗

Imaging Nanoscale Energy Transport and Conversion with Ultrafast Electron Microscopy (Final Technical Report)

Light-matter interactions are ubiquitous in nature and reside at the heart of innumerable technologies. The cascade of processes that occur when a material absorbs a photon of light are exceedingly complex and are interwoven in both space and time, rendering precise determination of the atomic-scale and ultrafast mechanisms immensely challenging. The advent of methods for generating short pulses of light several decades ago led to major advances in understanding the initial moments of light absorption and the resultant effects, though directly interrogating the response of the atoms within the material continued to prove challenging. More recently, methods for generating ultrashort pulses of X-rays and fast electrons have opened the way to probing photoinduced structural dynamics of a wide range of matter in multiple phases. An especially promising laboratory-scale method is ultrafast electron microscopy (UEM), wherein the modalities of conventional transmission electron microscopes (imaging, diffraction, spectroscopy) are extended into the femtosecond temporal regime. Here, the ultrafast imaging and diffraction modalities of UEM were used to study the transient structural aspects of photoexcitation of semiconducting materials (e.g., spatially-resolved electron-phonon coupling, excitation and emission of acoustic phonons, and discrete nanoscale scattering processes). The project had three main objectives: (1) determination of the excitation mechanisms of dense, hypersonic charge-carrier waves and the spatially mediated means by which they couple to the lattice via coherent phonon emission, especially with UEM imaging, wherein effects of nanoscale structural and morphological features on the coupling and relaxation dynamics are expected to dictate nucleation sites and preferred wave vectors, (2) elucidation of photoinduced acoustic-phonon seeding, emergence, propagation, and decay over nanoscale crystal regions and especially with respect to local strain fields and atomic-scale disruptions in lattice order, and (3) interwoven with the first two were efforts aimed at realizing combined angstrom-femtosecond spatiotemporal imaging with UEM. The outcomes and impacts of this project were the generation of new knowledge with respect to fundamental light-matter interactions and, especially, the spatially-mediated excitation and evolution of the structural response of materials following coherent photoexcitation. Importantly, the spatial and temporal resolutions of the UEM imaging modalities used are well-suited for such studies and enable spatially-resolved mechanisms to be determined as a function of atomic order, structural features, and morphology. In addition, ultrafast crystallographic measurements were used to correlate real- and reciprocal-space dynamics in order to determine atomic-scale preferential wave vectors and ultrafast scattering mechanisms, especially as dictated by specimen boundary conditions. The obtained results, as detailed in peer-reviewed publications and presentations, illustrate the importance of ultrafast, angstrom-scale real-space imaging for developing a comprehensive understanding of energy transport and conversion in materials.

47 OTHER INSTRUMENTATION↗

Illuminating gut microbiome signaling pathways that regulate host circadian rhythms

The gut microbiome affects host physiology by modulating nutrient acquisition and creating chemical signals that are received by host receptors. The molecular details of the orchestration of these microbial signaling processes remain largely unclear. We used a function-centric approach to interrogate the mechanistic links between gut microbiome metabolism and host circadian rhythms. We used rodent models, including germ-free mice, to determine how the gut microbiome influences host chronobiology by assaying metabolites in the gut and in circulation, and we used activity-based protein profiling to provide direct functional links to individual taxa. We specifically investigated how externally imposed behavioral schedules, such as feeding schedules, can desynchronize biological rhythms in metabolic organs (e.g., the gut, pancreas, and liver) from the central circadian rhythms regulated by the brain. We hypothesize that the gut microbiome creates chemical signals that can be entrained by feeding/fasting schedule to induce internal metabolic misalignment. Elaborating on the findings of this project will elucidate the chemical signals from the microbiome that modulate biological rhythms in the host’s metabolic organs.

59 BASIC BIOLOGICAL SCIENCES↗

Development and implementation of an in situ high-resolution isotopic microscope for measuring metabolic interactions in soil mesocosms (Final Report)

Many of our planet’s ecosystems rely on the activities of soil microbial communities. These microbes have significant and wide-ranging effects: they metabolize carbon and other nutrients, interact with plants and fungi, and perform other processes important to soil health. However, our ability to directly observe the enzymatic and metabolic activities of microbes within soil is currently limited, not only by the complexity of soil microbial communities themselves, but also by the lack of experimental tools to study them and their molecular interactions in situ. These challenges hinder our understanding of the life-sustaining processes of biomass decomposition and the manner in which it contributes to the movement of freed carbon within soil ecosystems. Here we aimed to develop a novel ultrahigh-resolution isotopic microscope that combines complementary imaging modalities to gain insights into metabolic cycling in soil. This final report covers both the portion of this work that was initially completed at the University of North Carolina at Chapel Hill from 2018 to 2019 (as award DE-SC0019012) and then from 2020 to 2022 (2023 in NCE) at the University of Massachusetts Chan Medical School. This goal was to build an integrated platform consisting of fluorescence microscopy, Raman microspectroscopy, and nanospray desorption electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nanoDESI-FTICR-MS) to directly investigate microbial activities and molecular transformations occurring in soil by exploiting the use of both fluorescent labels and stable isotope probing. Specifically, our instrument was conceived as integrating: (A) fluorescence detection to localize soil microbes, identify bacteria taking up polysaccharides, and monitor gene expression of enzymes involved in decomposition; (B) Raman microspectroscopy to determine which microbes incorporate decomposition products into their biomass, as well as which decomposers are metabolically active; and (C) nanoDESI-FTICR-MS imaging to spatially probe, in real-time, the metabolites in the surrounding area, which we expect will reveal the distributions of the products of the enzymatic breakdown of polysaccharides, as well as specialized metabolites acting as cell-cell signals between decomposers. To enable these measurements, we exploited fluorescence-based probes to map the microbes that are enzymatically active (per A) and utilized stable isotope-labeled substrates to visualize both the microbial and molecular fate of decomposed biomass (B and C, respectively). To accomplish our goal, we combined the expertise of a multidisciplinary group of scientists to pursue the construction of this microscope and to investigate scientific questions that would be facilitated by such a capability. We aimed to employ this spatially informative, high-resolution isotopic microscope to visualize the critical steps of biomass degradation and the molecular fate of other environmentally relevant substrates within soil mesocosms. Accordingly, this technology will enhance our understanding of the microbial and metabolic interactions occurring within soil communities that are relevant to carbon degradation and other soil processes. The instrument has been developed and housed at EMSL, where it will be available to the entire EMSL User Base, enabling a variety of related DOE-relevant systems to be interrogated in the future by diverse scientific research groups.

59 BASIC BIOLOGICAL SCIENCES↗

New Quantum Phenomena by Combining 2D Materials with Complex Oxides

This project focused on forming clean interfaces between exfoliated 2D materials and epitaxial oxides with the goal of determining the extent to which the electronic and magnetic properties of the former are influenced by the latter. Clear effects were observed in both device structures for which electronic transport properties were measured and unpatterned interfaces interrogated by polarized light to determine magnetic dichroic response. This work resulted in one paper already published and two others to be written, pending the outcome of ongoing experiments and theoretical calculations

36 MATERIALS SCIENCE↗

WIRE-21 Experiment Irradiation Conditions and In-Situ Data Collection

This report summarizes the in situ data collected during three cycles of irradiation (~75 days) of the Wireless Instrumented Removable Beryllium Experiment 2021 (WIRE-21) in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR). The experiment was designed primarily to evaluate the effects of high neutron flux and fluence on the performance of wireless temperature and pressure sensors being developed by Westinghouse Electric Company (WEC). WEC’s sensors could provide critical data regarding the evolution of centerline temperatures and pressurization due to fission gas release during fuel operation in light-water reactors (LWRs) or various advanced reactor applications. In addition to WEC’s wireless sensors, many other sensors were interrogated, including thermocouples, self-powered neutron detectors (SPNDs), distributed fiber optic temperature sensors, and passive neutron flux wires and silicon carbide thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Fissile Mass Estimation Python Script for the Advanced Experimental Fuel Counter (AEFC)

The Advanced Experimental Fuel Counter (AEFC) is a non-destructive assay (NDA) instrument developed to quantify the residual fissile mass in research reactor spent fuel assemblies. The system is installed in a spent fuel pool and measurements are acquired underwater. A calibration curve relates the totals and coincidence counting signal from active interrogation of the spent fuel assemblies to the fissile mass remaining in the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Optical Fiber-Based Sensors for Nuclear Microreactor Structural Health Monitoring

This report provides an experimental assessment of two different optical fiber–based acoustic sensors that are being investigated for application in nuclear microreactors to enhance structural health monitoring capabilities. Optical fibers are resilient in high-temperature and high-radiation environments, have a small sensor footprint, are immune to electromagnetic interference, and are capable of spatially distributed sensing. The two sensors investigated here are (1) Fabry–Pérot Cavities (FPCs) between two copper-coated fibers, embedded in nickel capillary tubes and (2) type-I fiber Bragg grating (FBG) arrays contained within metal capillary tubes. These sensors can be interrogated using low-coherence interferometry or swept wavelength interferometry, respectively, to measure the resonant frequencies of the components or systems to which these sensors are bonded. The FPC developed herein has been subjected to temperatures up to nearly 800°C while tack-welded to a tubular test specimen. Even at the highest temperatures, the measured resonant frequencies compared well with those obtained using an accelerometer that was bonded to an unheated portion of the specimen. The FBG array was tested in multiple bonding configurations to a tubular test specimen, all at room temperature, with the understanding that high temperature (i.e., type II) FBGs could be used to obtain similar data at high temperatures; the FBG array data were validated with noncontact laser vibrometry, which is being used at Los Alamos National Laboratory to relate acoustic signatures to component stresses and/or structural defects. The goal of this work is to identify the most promising techniques that are also compatible with operation in a microreactor environment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance Evaluation of the Starfire nGen-350 DD Neutron Generator for use with the Fast Neutron Coincidence Collar

The Starfire Industries nGen-350 DD neutron generator has been developed for use with the Fast Neutron Coincidence Collar (FNCL). The generator was adapted from the nGen-310 model generator by Starfire to accommodate an International Atomic Energy Agency (IAEA) request to incorporate a neutron yield stabilization mechanism. An nGen-350 generator was obtained by Oak Ridge National Laboratory (ORNL) for evaluation as a potential neutron interrogation source replacement for Am(Li) in the FNCL. This report provides a summary of the performance of the nGen-350.

43 PARTICLE ACCELERATORS↗

Strain measurements of Nb₃Sn coils with optical fibers

The HL-LHC at CERN will be using new superconducting quadrupole magnets (MQXFA) made of Nb₃Sn that are in the process of being tested before installation in the LHC tunnel. MQXFA07 and MQXFA08 magnets failed because of high stress developed at the coil wedge/end spacer interface, where the Nb₃Sn coil, the stainless-steel end parts, and copper wedges exhibit different strain responses. Interrogating a cut piece of coil QXFP06 with optical fibers, we expect to get a better understanding of the stress response of the coil wedge/end spacer interface.

Nisa, Kuvvetn↗

Clean Energy Cybersecurity Accelerator Cohort 1: Authentication and Authorization

In the 2023 National Cybersecurity Strategy, the Biden-Harris Administration defines the need for a "defensible, resilient digital ecosystem where it is costlier to attack systems than defend them." The strategy cites the Clean Energy Cybersecurity Accelerator (CECA) as an exemplary effort to bolster the security and resilience of clean energy generation. These efforts help "secure the clean energy grid of the future and [generate] security best practices that extend to other critical infrastructure sectors" and promise broad and far-reaching impacts to bridge the capabilities of private industry and the needs of energy production. Cohort 1 of CECA launched in the fall of 2022 with a focus on solutions that provide strong authentication and authorization for industrial control systems to mitigate attacks on the energy grid. Authentication and authorization verify that the identity (authentication) and permissions (authorization) of a user or device are aligned with their assigned roles. Weaknesses in either can have serious repercussions. To assess the strength of Cohort 1's solutions, CECA devised threat scenarios grounded in historical precedents: the CECA team reviewed exploits from real-world case studies of state-sponsored actors to match the assessment's attack paths and targets. Cohort 1 results provided the energy industry, product vendors, and related agencies valuable insights into the efficacy and applicability of solutions in common system configurations under realistic threat scenarios. The results of the assessment highlight points for interrogation and improvement in subsequent technology iterations. CECA's evaluations are part of an ongoing conversation and collaboration to bolster U.S. cyber resilience against adversaries today and in the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HTV Post Irradiation Examination (PIE) Results and Analysis

This report is responsive to 2017 Idaho National Laboratory (INL) Memorandum Purchase Order No. 00181805, statement of work 13687 “HTR Graphite R&D – FY ORNL 2017 MPO”, Deliverable 12A “issue final report on the HTV PIE to INL”, due June 15 th 2017.The HTV (High Temperature Vessel) was a HFIR (High Flux Isotope Reactor) high temperature target rod capsule in support of the DOE’s (Department of Energy) High Temperature Reactor (HTR) program. The HTV capsule contained eight sub-capsules, each with nine graphite specimens. The sub-capsules were designed to operate at ~900°C, ~1200°C or ~1600°C. The actual irradiation temperature was established by interrogating SiC and graphite TMs during PIE (post-irradiation examination. The capsule dose ranged from 1.49 dpa to 3.34 dpa, and varied with specimen position within the capsule the maximum dose occurring at the reactor mid-plane and the minimum dose occurring at the core periphery. The irradiated graphite specimens were examined during PIE to establish their high temperature dimensional and elastic (Young’s) modulus changes. The PIE results are reported and analyzed here. The dimensional and modulus changes were shown to have a strong thermal dependence. The dimensional changes were small, being of the order of a few percent or less, ranging from a maximum shrinkage of -3.1% (PCEA WG, T irr =1500°C at 3.3 dpa) to +0.131% (2114 AG, T irr = 869 at 3.2 dpa). The specimen volume shrinkages varied from –0.81 (2114, T irr = 840 at 3.1 dpa) to -9.15% (PCEA, T irr =1500°C at 3.3 dpa). The volume changes were larger at higher Irradiation temperatures. Of the six grades examined, only 2114 moved into the net positive dimensional swelling situation. Significantly, the volume change for 2114 remained negative at the doses and temperature tested here. Dimensional and volume changes were explained in terms of the temperature dependence of the crystal growth rate, the anisotropy of the crystal growth (crystallographic c-axis growth and crystallographic a-direction shrinkage) and the thermal closure of aligned micro-porosity. The modulus changes were much larger, being of the order of a few tens of percent. A trend of lesser fractional increases of Young’s Modulus with an increasing T irr was noted. The minimum increase in Young’s Modulus was 20% (H-451 WG, T irr =1500°C at 3.3 dpa) and the maximum 71% (IG-110, T irr = 840(actual) at 3.3 dpa). The rise in Young’s modulus is attributed to dislocation pinning by lattice defects produced by neutron irradiation and the temperature dependency is related to the irradiation temperature influence on the number of defect available to pin dislocations.

36 MATERIALS SCIENCE↗

Distributed Acoustic Sensing as a Monitoring Tool at LANL [Slides]

DAS records a variety of signals, including (1) earthquakes and volcanic eruptions, (2) explosions (DAG, mining, etc.), (3) acoustic waves, (4) ocean (waves, whales), (5) vehicle, ship and pedestrian traffic, (6) glaciology and landslides, and (7) oil and gas. Main questions include: (1) what is the extent of the signal content? (2) how does DAS compare to traditional sensors? (3) how do interrogators, fiber types, and fiber depth burials impact measurements? (4) special applications offshore to overcome the lack of instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Threat Agnostic Virulence Assessment of Pathogens

Virulence assessment of new, emerging, and engineered pathogens is critical to mounting an appropriate response to a biothreat agent. The capacity of the pathogen to colonize human and harm tissues must be characterized to understand pathogenicity pathways and optimize diagnosis and treatment of resulting disease. Respiratory pathogens are of interest because they can have high transmissibility rates, as observed with the SARS-CoV-2 virus, the causative agent of Covid-19. Current technologies are insufficient to assess threats due to their reliance on systems with only one cell type and on sequencing the pathogen. However, it is known that sequence is not an accurate predictor of function, and sequencing can be unreliable for newly emerged or engineered pathogens. An ideal system would consist of relevant epithelial cell types and an assay sensitive enough to detect changes in host responses that do not rely on DNA sequencing. We chose a system consisting of host lung epithelial cells that can be used to assess the virulence of unknown respiratory pathogens. We interrogated pathogens using this model and assess features of pathogenicity. Our objective is to leverage PNNLs strengths in tissue engineering and proteomics capabilities to build a multiple reaction monitoring (MRM) or parallel reaction monitoring (PRM) liquid chromatography-tandem mass spectrometry assay for human host cell proteins whose abundance is influenced by infection. These responses can were then assessed for relative virulence using pathogen agnostic signatures. When confronted with a pathogen, cells activate dedicated signaling pathways, typically through phosphorylation of regulatory proteins and downstream activation of host cell networks.

59 BASIC BIOLOGICAL SCIENCES↗