At least 1,567 records · Page 87

Computer control of a far infrared interferometer

A simple interface has been designed for the automatic control and data collection from a Grubb Parsons Mark III cube interferometer. A computer is used to automatically step the movable mirror on the interferometer. Data may be directly input into the computer for immediate transformation or stored for later analysis via a fast Fourier transformation. The interface is based on a commercial analog-to-digital converter having a parallel-to-serial data converter. The device can also display ASCII characters sent from the computer in parallel binary code. The system is applicable to recording interferograms having long time durations and to measuring multiple interferograms for statistical averaging.

Breecher, J.↗

A demonstration of real-time connected element interferometry for spacecraft navigation

Connected element interferometry is a technique of observing a celestial radio source at two spatially separated antennas, and then interfering the received signals to extract the relative phase of the signal at the two antennas. The high precision of the resulting phase delay data type can provide an accurate determination of the angular position of the radio source relative to the baseline vector between the two stations. A connected element interferometer on a 21-km baseline between two antennas at the Deep Space Network's Goldstone, CA tracking complex is developed. Fiber optic links are used to transmit the data at 112 Mbit/sec to a common site for processing. A real-time correlator to process these data in real-time is implemented. The architecture of the system is described, and observational data is presented to characterize the potential performance of such a system. The real-time processing capability offers potential advantages in terms of increased reliability and improved delivery of navigational data for time-critical operations. Angular accuracies of 50-100 nrad are achievable on this baseline.

Edwards, C.↗

The Palomar Testbed Interferometer

The Palomar Testbed Interferometer (PTI) is a long-baseline infrared interferometer located at Palomar Observatory, California. It was built as a testbed for interferometric techniques applicable to the Keck Interferometer. First fringes were obtained in 1995 July. PTI implements a dual-star architecture, tracking two stars simultaneously for phase referencing and narrow-angle astrometry. The three fixed 40 cm apertures can be combined pairwise to provide baselines to 110 m. The interferometer actively tracks the white-light fringe using an array detector at 2.2 microns and active delay lines with a range of +/-38 m. Laser metrology of the delay lines allows for servo control, and laser metrology of the complete optical path enables narrow-angle astrometric measurements. The instrument is highly automated, using a multiprocessing computer system for instrument control and sequencing.

Colavita, M. M.↗

Dual laser holography for in situ measurement of plasma facing component erosion (invited)

A digital holography (DH) surface erosion/deposition diagnostic is being developed for 3D imaging of plasma facing component surfaces in situ and in real time. Digital holography is a technique that utilizes lasers reflected from a material surface to form an interferogram, which carries information about the topology of the surface when reconstructed. As described, dual CO 2 lasers at 9.271 and 9.250 μm wavelengths illuminate the interrogated surface (at a distance of ~1 m) in a region of ~1 cm × 1 cm. The surface feature resolution is ~0.1 mm in the plane of the surface, and the depth resolution ranges from ~0.0001 to ~2 mm perpendicular to the surface. The depth resolution lower limit is set by single-laser and detector optical limitations, while the upper limit is determined by 2π phase ambiguity of the dual-laser synthetic wavelength. Measurements have been made “on the bench” to characterize the single-laser and dual-laser DH configurations utilizing standard resolution targets and material targets that were previously exposed to high flux plasmas in either the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) or the electro-thermal (ET) arc source. Typical DH measurements were made with 0.03 ms integration with an IR camera that can be framed at rates approaching 1.5 kHz. Finally, the DH diagnostic system is progressing toward in situ measurements of plasma erosion/deposition either on Proto-MPEX or the ET arc source.

47 OTHER INSTRUMENTATION↗

A new generation of cryogenic high- Q Fabry–Perot resonators for ultrastable lasers

We have performed a comparative analysis of the characteristics of laser resonators fabricated from various materials. The greatest attention is paid to the problem of Brownian noise leading to fluctuations in the resonator length and limitation of the frequency stability of a laser actively stabilised by the transmission peak of a high- Q Fabry–Perot resonator. A possibility of designing new-generation ultrastable laser systems based on cryogenic crystalline resonators is shown. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

J-GEM optical and near-infrared follow-up of gravitational wave events during LIGO’s and Virgo’s third observing run

The Laser Interferometer Gravitational-wave Observatory Scientific Collaboration and Virgo Collaboration (LVC) sent out 56 gravitational-wave (GW) notices during the third observing run (O3). The Japanese Collaboration for Gravitational wave ElectroMagnetic follow-up (J-GEM) performed optical and near-infrared observations to identify and observe an electromagnetic (EM) counterpart. We constructed a web-based system that enabled us to obtain and share information on candidate host galaxies for the counterpart, and the status of our observations. Candidate host galaxies were selected from the GLADE catalog with a weight based on the 3D GW localization map provided by LVC. We conducted galaxy-targeted and wide-field blind surveys, real-time data analysis, and visual inspection of observed galaxies. We performed galaxy-targeted follow-ups to 23 GW events during O3, and the maximum probability covered by our observations reached 9.8%. Among these, we successfully started observations for 10 GW events within 0.5 days after the detection. This result demonstrates that our follow-up observation has the potential to constrain EM radiation models for a merger of binary neutron stars at a distance of up to ~100 Mpc with a probability area of ≤ 500 deg 2 .

79 ASTRONOMY AND ASTROPHYSICS↗

Fourier and Hadamard transform spectrometers - A limited comparison

An encoding figure of merit is established for a detector-noise limited Fourier transform spectrometer (FTS) and compared to the comparable figure for a Hadamard transform spectrometer (HTS). The limitation of the Fourier system is partly that it does not truly Fourier analyze the radiation. Instead a cosine squared modulation is imposed on the different spectral frequencies. An additional difficulty is that neither the cosine nor the cosine squared functions form an orthonormal set. This makes the Fellgett's advantage (root-mean-squared figure of merit) for a single detector Michelson interferometer a factor of the square root of (N/8) greater than for a conventional grating instrument - rather than the square root of (N/2). The theoretical limit would be the square root of N.

Tai, M. H.↗

Wide angle astrometric demonstration on the micro-arcsecond metrology testbed for the space interferometry mission

The Space Interferometry Mission (SIM) requires fringe measurements to the level of picometers in order to produce astrometric data at the micro-arc-second level. To be more specific, it is necessary to measure both the position of the starlight central fringe and the change in the internal optical path of the interferometer to a few hundreds of picometers. The internal path is measured with a small heterodyne metrology beam, whereas the starlight fringe position is estimated with a CCD sampling a large concentric annular beam. One major challenge for SIM is to align the metrology beam with the starlight beam to keep the consistency between these two sensors at the system level while articulating the instrument optics over the field of view.

metrology↗

The Keck Interferometer Nuller

The Keck Interferometer Nuller (KIN), the first operational separated-aperture infrared nulling interferometer, was designed to null the mid-infrared emission from nearby stars so as to ease the measurement of faint circumstellar emission. This paper describes the basis of the KIN's four-beam, two-stage measurement approach and compares it 10 the simpler case of a two-beam nuller. In the four-beam KIN system, the starlight is first nulled in a pair of nullers operating on parallel 85 m Keck-Keck baselines, after which "cross-combination" on 4 m baselines across the Keck apertures is used to modulate and detect residual coherent off-axis emission. Comparison to the constructive itellar fringe provides calibration. The response to an extended source is similar in the two cases, except that the four-beam response includes a term due to the visibility of the source on the cross-combiner baseline-a small effect for relatively compact sources. The characteristics of the dominant null depth errors are also compared for the two cases. In the two-beam nuller, instrumental imperfections and asymmetries lead to a series of quadratic, positivedefinite null leakage terms. For the four-beam nuller, the leakage is instead a series of correlation cross-tenns combining corresponding errors in each of the two nullers, which contribute offsets only to the extent that these errors are correlated on the timescale of the measurement. This four-beam architecture has allowed a significant (approx. order of magnitude) improvement in mid-infrared long-baseline fringe-visibility accuracies.

Serabyn, E.↗

A CATALOG OF CALIBRATOR STARS FOR NEXT-GENERATION OPTICAL INTERFEROMETERS

Benchmark stars with known angular diameters are key to calibrating interferometric observations. With the advent of optical interferometry, there is a need for suitably bright, well-vetted calibrator stars over a large portion of the sky. We present a catalog of uniformly computed angular diameters for 1510 stars in the northern hemisphere, brighter than V = 6 and with declinations -15°<δ<82°. The median angular stellar diameter is 0.529 mas. The list has been carefully cleansed of all known binary and multiple stellar systems. We derive the angular diameters for each of the stars by fitting spectral templates to the observed spectral energy distributions (SEDs) from literature fluxes. We compare these derived angular diameters against those measured by optical interferometry for 75 of the stars, as well as to 176 diameter estimates from previous calibrator catalogs, finding in general excellent agreement. The final catalog includes our goodness-of-fit metrics as well as an online atlas of our SED fits. The catalog presented here permits selection of the best calibrator stars for current and future visible-light interferometric observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron density and temperature profile diagnostics for C-2 field reversed configuration plasmas

The 9-point Thomson scattering diagnostic system for the C-2 field reversed configuration plasmas is improved and the measured electron temperature profiles are consistent with theoretical expectations. Rayleigh scattering revealed a finite line width of the ruby laser emission, which complicates density calibration. Taking advantage of the plasma wobble motion, density profile reconstruction accuracy from the 6-chord two-color CO{sub 2}/HeNe interferometer data is improved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the thermal noise limit of ultrastable optical cavities

We consider two methods of lowering thermal noise, which limits the attainable frequency stability of lasers stabilised to a high-Q external Fabry – Perot cavity. These are cavity lengthening and use of high-Q mechanical materials in the production of its constituent parts. The results of numerical simulation are outlined for the horizontal and vertical suspension systems of the cavity body and its sensitivity to vibrations in these cases. The progress in the development of ultrastable laser systems using cryogenic silicon cavities is also discussed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Steady-state entanglement and normal-mode splitting in an atom-assisted optomechanical system with intensity-dependent coupling

In this paper, we study theoretically bipartite and tripartite continuous variable entanglement as well as normal-mode splitting in a single-atom cavity optomechanical system with intensity-dependent coupling. The system under consideration is formed by a Fabry-Perot cavity with a thin vibrating end mirror and a two-level atom in the Gaussian standing wave of the cavity mode. We first derive the general form of the Hamiltonian describing the tripartite intensity-dependent atom-field-mirror coupling due to the presence of the cavity mode structure. We then restrict our treatment to the first vibrational sideband of the mechanical resonator and derive a tripartite atom-field-mirror Hamiltonian. We show that when the optical cavity is intensely driven, one can generate bipartite entanglement between any pair in the tripartite system and that, due to entanglement sharing, atom-mirror entanglement is efficiently generated at the expense of optical-mechanical and optical-atom entanglement. We also find that in such a system, when the Lamb-Dicke parameter is large enough, one can simultaneously observe the normal mode splitting into three modes.

74 ATOMIC AND MOLECULAR PHYSICS↗

On a two-pass scheme without a faraday mirror for free-space relativistic quantum cryptography

The stability of destructive interference independent of the input polarization and the state of a quantum communication channel in fiber optic systems used in quantum cryptography plays a principal role in providing the security of communicated keys. A novel optical scheme is proposed that can be used both in relativistic quantum cryptography for communicating keys in open space and for communicating them over fiber optic lines. The scheme ensures stability of destructive interference and admits simple automatic balancing of a fiber interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fabrication of silicon-tipped fiber-optic temperature sensors using aerogel-assisted glass soldering with precise laser heating

We demonstrate the fabrication of fiber-optic Fabry–Perot interferometer (FPI) temperature sensors by bonding a small silicon diaphragm to the tip of an optical fiber using low melting point glass powders heated by a 980 nm laser on an aerogel substrate. The heating laser is delivered to the silicon FPI using an optical fiber, while the silicon temperature is being monitored using a 1550 nm white-light system, providing localized heating with precise temperature control. The use of an aerogel substrate greatly improves the heating efficiency by reducing the thermal loss of the bonding parts to the ambient environment. A desirable temperature for bonding can be achieved with relatively small heating laser power. The bonding process is carried out in an open space at room temperature for convenient optical alignment. The precise temperature control ensures minimum perturbation to the optical alignment and no induced thermal damage to the optical parts during the bonding process. For demonstration, we fabricated a low-finesse and high-finesse silicon FPI sensor and characterized their measurement resolution and temperature capability. The results show that the fabrication method has a good potential for high-precision fabrication of fiber-optic sensors.

Sheng, Qiwen↗

A demonstration of a transportable radio interferometric surveying system with 3-cm accuracy on a 307-m base line

A precision geodetic measurement system (Aries, for Astronomical Radio Interferometric Earth Surveying) based on the technique of very long base line interferometry has been designed and implemented through the use of a 9-m transportable antenna and the NASA 64-m antenna of the Deep Space Communications Complex at Goldstone, California. A series of experiments designed to demonstrate the inherent accuracy of a transportable interferometer was performed on a 307-m base line during the period from December 1973 to June 1974. This short base line was chosen in order to obtain a comparison with a conventional survey with a few-centimeter accuracy and to minimize Aries errors due to transmission media effects, source locations, and earth orientation parameters. The base-line vector derived from a weighted average of the measurements, representing approximately 24 h of data, possessed a formal uncertainty of about 3 cm in all components. This average interferometry base-line vector was in good agreement with the conventional survey vector within the statistical range allowed by the combined uncertainties (3-4 cm) of the two techniques.

Ong, K. M.↗

High-altitude-resolution stratospheric measurements with the Arecibo 2380-MHz radar

The 2380-MHz planetary radar of the Arecibo Observatory and the 30-m interferometer antenna at Higuialles, Puerto Rico, have been instrumented as a bistatic radar for stratospheric turbulence research studies. The average power of the transmitter is 400 kW, and it uses the 300-m Arecibo spherical reflector. A vertical resolution of 30 m has been achieved by means of a novel continuous pseudorandom phase coding scheme. Preliminary results obtained with the system are presented. The thickness and internal structure of turbulent stratospheric layers have been resolved for the first time. The potential of the instrument in assessing the role of turbulence in the vertical transport of tracers, contaminants, and momentum is discussed.

Woodman, R. F.↗

Fiber-optic thermometer using Fourier transform spectroscopy

An integrated-optic Mach-Zender interferometer is used as a Fourier transform spectrometer to analyze the input and output spectra of a temperature-sensing thin-film etalon. This configuration provides a high degree of immunity to the effects of changes in the source spectrum, and it readily permits the interrogation of a number of different sensors using a single spectrometer. In addition, this system has a potentially low cost because it uses optical communications hardware that may in the future be manufactured in large quantities.

Beheim, Glenn↗