PROGRESS IN DESIGN OF THE INSTRUMENTATION AND CONTROL OF THE TOKAMAK COOLING WATER SYSTEM

This paper discusses progress in the design of the control, interlock and safety systems of the Tokamak Cooling Water System (TCWS) for the ITER fusion reactor. The TCWS instrumentation and control (I&C) is one of approximately 200 separate plant I&C systems (e.g., vacuum system I&C, magnets system I&C) that interface to a common central I&C system through standardized networks. Several aspects of the I&C are similar to the I&C of fission-based power plants. However, some of the unique features of the ITER fusion reactor and the TCWS (e.g., high quasi-static magnetic field, need for baking and drying as well as cooling operations), also demand some unique safety and qualification considerations. The paper compares the design strategy/guidelines of the TCWS I&C and the I&C of conventional nuclear power plants. Issues such as safety classifications, independence between control and safety systems, sensor sharing, redundancy, voting schemes, and qualification methodologies are discussed. It is concluded that independence and separation requirements are similar in both designs. However, the voting schemes for safety systems in nuclear power plants typically use 2oo4 (i.e., 4 divisions of safety I&C, any 2 of which is sufficient to trigger a safety action), while 2oo3 voting logic - within each of 2 independent trains - is used in the TCWS I&C. It is also noted that 2oo3 voting is also acceptable in nuclear power plants if adequate risk assessment and reliability is demonstrated. Finally, while qualification requirements provide similar guidance [e.g., both IEC 60780 (invoked in ITER-space), and IEEE 323 (invoked in fission power plant space) provide similar guidance], an important qualification consideration is the susceptibility of I&C to the magnetic fields of ITER. Also, the radiation environments are different. In the case of magnetic fields the paper discusses some options that are being considered.

Korsah, Kofi↗

Optimal Voltage Regulation for Unbalanced Distribution Networks Considering Distributed Energy Resources

With increasing penetration of distributed generation in the distribution networks (DN), the secure and optimal operation of DN has become an important concern. In this paper, an iterative quadratic constrained quadratic programming model to minimize voltage deviations and maximize distributed energy resource (DER) active power output in a three phase unbalanced distribution system is developed. The optimization model is based on the linearized sensitivity coefficients between controlled variables (e.g., node voltages) and control variables (e.g., real and reactive power injections of DERs). To avoid the oscillation of solution when it is close to the optimum, a golden search method is introduced to control the step size. Numerical simulations on modified IEEE 13 nodes test feeders show the efficiency of the proposed model. Compared to the results solved by heuristic search (harmony algorithm), the proposed model converges quickly to the global optimum.

distributed energy resources↗

Parallel Harmony Search Based Distributed Energy Resource Optimization

This paper presents a harmony search based parallel optimization algorithm to minimize voltage deviations in three phase unbalanced electrical distribution systems and to maximize active power outputs of distributed energy resources (DR). The main contribution is to reduce the adverse impacts on voltage profile during a day as photovoltaics (PVs) output or electrical vehicles (EVs) charging changes throughout a day. The IEEE 123- bus distribution test system is modified by adding DRs and EVs under different load profiles. The simulation results show that by using parallel computing techniques, heuristic methods may be used as an alternative optimization tool in electrical power distribution systems operation.

Ceylan, Oguzhan↗

Advanced Energy Storage Management in Distribution Network

With increasing penetration of distributed generation (DG) in the distribution networks (DN), the secure and optimal operation of DN has become an important concern. In this paper, an iterative mixed integer quadratic constrained quadratic programming model to optimize the operation of a three phase unbalanced distribution system with high penetration of Photovoltaic (PV) panels, DG and energy storage (ES) is developed. The proposed model minimizes not only the operating cost, including fuel cost and purchasing cost, but also voltage deviations and power loss. The optimization model is based on the linearized sensitivity coefficients between state variables (e.g., node voltages) and control variables (e.g., real and reactive power injections of DG and ES). To avoid slow convergence when close to the optimum, a golden search method is introduced to control the step size and accelerate the convergence. The proposed algorithm is demonstrated on modified IEEE 13 nodes test feeders with multiple PV panels, DG and ES. Numerical simulation results validate the proposed algorithm. Various scenarios of system configuration are studied and some critical findings are concluded.

linearization↗

Numeric Modified Adomian Decomposition Method for Power System Simulations

This paper investigates the applicability of numeric Wazwaz El Sayed modified Adomian Decomposition Method (WES-ADM) for time domain simulation of power systems. WESADM is a numerical method based on a modified Adomian decomposition (ADM) technique. WES-ADM is a numerical approximation method for the solution of nonlinear ordinary differential equations. The non-linear terms in the differential equations are approximated using Adomian polynomials. In this paper WES-ADM is applied to time domain simulations of multimachine power systems. WECC 3-generator, 9-bus system and IEEE 10-generator, 39-bus system have been used to test the applicability of the approach. Several fault scenarios have been tested. It has been found that the proposed approach is faster than the trapezoidal method with comparable accuracy.

Adomian Decomposition↗

A Method of Synchrophasor Technology for Detecting and Analyzing Cyber-Attacks

Studying cybersecurity events and analyzing their impacts encourage planners and operators to develop innovative approaches for preventing attacks in order to avoid outages and other disruptions. This work considers two parts in security studies; detecting an integrity attack and examining its effects on power system generators. The detection was conducted through employing synchrophasor technology to provide authentication of ACG commands based on observed system operating characteristics. The examination of an attack is completed via a detailed simulation of a modified IEEE 68-bus benchmark model to show the associated power system dynamic response. The results of the simulation are discussed for assessing the impacts of cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gauging User Interest in Non-Traditional Library Resources

The National Renewable Energy Laboratory (NREL) is a government funded research laboratory based in Golden, Colorado. In addition to collecting traditional library resources such as journals, conference proceedings, and print and electronic books, the library also spends a significant portion of its collection development funds on resources not often found in many libraries: technical industry standards (e.g., ISO, IEC, ASTM, IEEE) and energy-related market reports. Assessing user needs for these resources is difficult for a number of reasons, particularly because standardized usage statistics are lacking or non-existent. Standards and market reports are generally costly and include fairly restrictive license agreements, which increase the importance of making informed collection development decisions. This presentation will discuss the NREL Library's current collection assessment and development practices as they relate to these unique resources.

99 GENERAL AND MISCELLANEOUS↗

GMLC Hawaii Regional Partnership: Distributed Inverter-Based Grid Frequency Support

This presentation is part of a panel session at the IEEE ISGT conference on Grid Modernization Initiative projects. This segment of the panel session provides a brief overview of a Hawaii Regional Partnership project focusing grid frequency support from distributed resources on the fastest time scales.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Allocation of Static Var Compensator via Mixed Integer Conic Programming

Shunt FACTS devices, such as, a Static Var Compensator (SVC), are capable of providing local reactive power compensation. They are widely used in the network to reduce the real power loss and improve the voltage profile. This paper proposes a planning model based on mixed integer conic programming (MICP) to optimally allocate SVCs in the transmission network considering load uncertainty. The load uncertainties are represented by a number of scenarios. Reformulation and linearization techniques are utilized to transform the original non-convex model into a convex second order cone programming (SOCP) model. Numerical case studies based on the IEEE 30-bus system demonstrate the effectiveness of the proposed planning model.

Zhang, Xiaohu↗

Overcoming the Power Wall by Exploiting Application Inexactness and Emerging COTS Architectural Features

Abstract—Energy and power consumption are major limitations to continued scaling of computing systems. Inexactness where the quality of the solution can be traded for energy savings has been proposed as a counterintuitive approach to overcoming those limitation. However, in the past, inexactness has been necessitated the need for highly customized or specialized hardware. In order to move away from customization, in earlier work [4], it was shown that by interpreting precision in the computation to be the parameter to trade to achieve inexactness, weather prediction and page rank could both benefit in terms of yielding energy savings through reduced precision, while preserving the quality of the application. However, this required representations of numbers that were not readily available on commercial off-the-shelf (COTS) processors. In this paper, we provide opportunities for extending the the notion of trading precision for energy savings into the world COTS. We provide a model and analyze the opportunities and behavior of all three IEEE compliant precision values available on COTS processors: (i) double (ii) single, and (iii) half. Through measurements, we show through a limit study energy savings in going from double to half precision can potentially exceed a factor of four, largely due to memory and cache effects.

Fagan, Mike↗

Efficient Certificate Verification for Vehicle-to-Grid Communications

While public charging stations are typically used for Electric Vehicle (EV) such as charging, home microgrids that may act as private charging stations are also expected to be used for meeting the increased EV charging demands in the future. Such home microgrids can be accessible through their smart meters, which makes advanced metering infrastructure (AMI) a viable alternative for vehicle-to-grid (V2G) communications. However, to ensure secure V2G communications using public-keys, smart meters will need to maintain certificate revocation lists (CRLs) not just for the AMI network but also for large number of EVs that may interact with them. For resource-constrained smart meters, this will increase the storage requirements and introduce additional overhead in terms of delay and CRL maintenance. To eliminate this burden, we propose keeping merely non-revoked certificates that belong to EVs, which are usually driven within the vicinity of that particular microgrid. The motivation comes from the fact that it is inefficient to distribute and store a large CRL that has revocation information about all EVs in the whole system as most of these EVs will never come to the geographic vicinity of that home microgrid. The approach ensures that any status changes of these certificates are communicated to the smart meters. We implemented the proposed approach in a realistic V2G communication scenario by using IEEE 802.11s mesh as the underlying AMI infrastructure using ns-3 simulator. The results confirmed that the proposed approach significantly reduces the certificate verification time and the storage requirements on smart meters.

25 ENERGY STORAGE↗

Convex Relaxation of OPF in Multiphase Radial Networks with Wye and Delta Connections

This panel presentation focuses on multiphase radial distribution networks with wye and delta connections, and proposes a semidefinite relaxation of the AC optimal power flow (OPF) problem. Two multiphase power flow models are developed to facilitate the integration of delta-connected loads or generation resources in the OPF problem. The first model is referred to as the extended branch flow model (EBFM). The second model leverages a linear relationship between phase-to-ground power injections and delta connections that holds under a balanced voltage approximation (BVA). Based on these models, pertinent OPF problems are formulated and relaxed to semidefinite programs (SDPs). Numerical studies on IEEE test feeders show that the proposed SDP relaxations can be solved efficiently by a generic optimization solver. Numerical evidence also indicates that solving the resultant SDP under BVA is faster than under EBFM. Moreover, both SDP solutions are numerically exact with respect to voltages and branch flows. It is further shown that the SDP solution under BVA has a small optimality gap, and the BVA model is accurate in the sense that it reproduces actual system voltages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Photovoltaic Hosting Capacity of Feeders with Reactive Power Control and Tap Changers

This paper proposes an algorithm to determine photovoltaic (PV) hosting capacity of power distribution networks as a function of number of PV injection nodes, reactive power support from the PVs, and the sub-station load tap changers (LTCs). In the proposed method, several minute by minute simulations are run based on randomly chosen PV injection nodes, daily PV output profiles, and daily load profiles from a pool of high-resolution realistic data set. The simulation setup is built using OpenDSS and MATLAB. The performance of the proposed method is investigated in the IEEE 123-node distribution feeder for multiple scenarios. The case studies are performed particularly for one, two, five and ten PV injection nodes, and looking at the maximum voltage deviations. Case studies show that the PV hosting capacity of the 123-node feeder greatly differs with the number of PV injection nodes. We have also observed that the PV hosting capacity increases with reactive power support and higher tap position of sub-station LTC.

14 SOLAR ENERGY↗

Supercapacitor to Provide Ancillary Services: Preprint

Supercapacitor technology has reached a level of maturity as a viable energy storage option available to support a modern electric power system grid; however, its application is still limited because of its energy capacity and the cost of the commercial product. In this paper, we demonstrate transient models of supercapacitor energy storage plants operating in coordination with run-of-the-river (ROR), doubly-fed induction generator hydropower plants (HPP) using a system control concept and architecture developed. A detailed transient model of a supercapacitor energy storage device is coupled with the grid via a three-phase inverter/rectifier and bidirectional DC-DC converter. In addition, we use a version of a 14-bus IEEE test case that includes the models of the supercapacitor energy storage device, ROR HPPs, and synchronous condensers that use the rotating synchronous generators of retired coal-powered plants. The purpose of the synchronous condensers is to enhance the system stability by providing voltage and reactive power control, provide power system oscillations damping, and maintain system inertia at secure levels. The control layer provides coordinated, decentralized operation of distributed ROR HPPs and energy storage as aggregate support to power system operations.

25 ENERGY STORAGE↗

Optimal Power Flow in Multiphase Radial Networks with Delta Connections: Preprint

This paper focuses on multiphase radial distribution networks with mixed wye and delta connections, and proposes a semidefinite relaxation of the AC optimal power flow (OPF) problem. Two multiphase power-flow models are developed to facilitate the integration of delta-connected generation units/loads in the OPF problem. The first model extends traditional branch flow models - and it is referred to as extended branch flow model (EBFM). The second model leverages a linear relationship between per-phase power injections and delta connections, which holds under a balanced voltage approximation (BVA). Based on these models, pertinent OPF problems are formulated and relaxed to semidefinite programs (SDPs). Numerical studies on IEEE test feeders show that SDP relaxations can be solved efficiently by a generic optimization solver. Numerical evidences indicate that solving the resultant SDP under BVA is faster than under EBFM. Moreover, both SDP solutions are numerically exact with respect to voltages and branch flows. It is also shown that the SDP solution under BVA has a small optimality gap, while the BVA model is accurate in the sense that it reflects actual system voltages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinative Voltage Control Strategy with Multiple Resources for Distribution Systems of High PV Penetration: Preprint

This paper presents an optimal voltage control methodology with coordination among different voltage-regulating resources, including controllable loads, distributed energy resources such as energy storage and photovoltaics (PV), and utility voltage-regulating devices such as voltage regulators and capacitors. The proposed methodology could effectively tackle the overvoltage and voltage regulation device distortion problems brought by high penetrations of PV to improve grid operation reliability. A voltage-load sensitivity matrix and voltage-regulator sensitivity matrix are used to deploy the resources along the feeder to achieve the control objectives. Mixed-integer nonlinear programming is used to solve the formulated optimization control problem. The methodology has been tested on the IEEE 123-feeder test system, and the results demonstrate that the proposed approach could actively tackle the voltage problem brought about by high penetrations of PV and improve the reliability of distribution system operation.

14 SOLAR ENERGY↗

Multiphase Optimal and Non-Singular Power Flow by Successive Linear Approximations: Preprint

We propose an optimal power flow method for multiphase power systems. The method works for both radial and meshed networks, and is able to accommodate different types of load/source connections such as wye, delta, etc. Moreover, the method generates a sequence of non-singular points in the electrical state space and a corresponding sequence of power injections, which can be used in real-time control settings. Under certain conditions, the sequences attain the local minimum. The method has been tested using several typical networks, including the IEEE 37-bus and 123-bus test feeders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DWT-Based Aggregated Load Modeling and Evaluation for Quasi-Static Time-Series Simulation on Distribution Feeders: Preprint

This paper presents an extension of a previously reported discrete wavelet transform (DWT) based load modeling methodology which targets at modeling time-series load profiles to enable the more effective and realistic quasi-static time-series simulation of distribution feeders. The time-series load model is composed of two major parts: 1) The low-resolution field-measured load data which usually have a resolution of 30 or 15 min., 2) The high-resolution load variability model data extracted from the established variability database which can have resolution up to 1 sec. A load aggregation methodology is developed to aggregate the load profiles so that load profiles at different transformer ratings can be effectively modeled. Validation, evaluation, and analysis of the developed load modeling approach has been performed on the IEEE-123 feeder and an actual utility feeder from California. The analysis completed on the two feeders have demonstrated the effectiveness and revealed the value of the developed model for distribution feeder quasi-static time-series simulation at high temporal resolution.

24 POWER TRANSMISSION AND DISTRIBUTION↗