Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Performance Analysis of Magnetohydrodynamic Drag Modulation for Actively Controlled Aerocapture at Neptune

While the Ice Giants are a top priority for flagship missions in the NASA’s near-term future, current technologies limit the scientific payload and mission timeline for future Uranian and Neptunian missions due to the need for fuel for orbit insertion maneuvers. Thus, to maximize the scientific potential of future missions, atmospheric aerocapture has been heavily researched. While atmospheric aerocapture simulations have proven enabling for capturing around Neptune, its deep atmospheric pass requires an aeroshell with robust thermal protection systems (TPS). Magnetohydrodynamically-controlled aerocapture serves as a potential solution to the limitations of both fully propulsive orbit insertion and aerodynamically controlled aerocapture. Through NASA Langley’s high-fidelity flight dynamics simulation, the Program to Optimize Simulated Trajectories II, both the aerodynamic-only and magnetohydrodynamic aerocapture methods were simulated and compared for identical missions to Neptune. After applying an optimized numerical predictor-corrector guidance algorithm for both methods, the results showed that magnetohydrodynamics has not only the control authority to successfully capture around Neptune, but also the unique advantage of a shallower atmospheric pass, decreasing the maximum heat load and the required TPS mass.

Danny N. Nguyen↗

Validation of a Two-Phase CFD Model for Predicting Tank Self-Pressurization in the Ground-Based K-Site Experiment

A two-phase CFD model for self-pressurization of a cryogenic storage tank partially filled with liquid hydrogen is presented using the Volume-Of-Fluid approach for representing the phase boundary and the associated interfacial heat, mass and momentum transfer between the liquid and the vapor regions. The CFD model is validated against self-pressurization experiment performed in the K-site flightweight hydrogen storage tank at NASA Glenn Research Center. Laminar and turbulent simulations together with conjugated heat transfer analysis are performed. Effects of turbulence, as well as tank wall conduction are presented and discussed. Predicted tank pressures and fluid temperatures are compared with the experimental data at two different heat loads for validating the CFD model.

phase change↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and Joule-Thomson and Stirling cryocoolers to reduce heat load on the He tank supporting the ADRs. Resolve was designed with tunable cryocooler drive frequencies so that interference could be avoided. The cryocooler generated micro-vibration changes with drive frequency and that micro-vibration causes interference and degrades instrument performance. Poor drive frequency choices have been shown to dramatically impact ADR cooling power, temperature stability, detector noise, and degrading spectroscopic performance. However, some choices are free of these features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is critical to achieving peak instrument performance. The drive frequencies of the Joule-Thomson cooler, near 52 Hz, and the Stirling coolers, near 15 Hz, were adjusted in three scan sequences while measuring interference to narrow candidate frequency options. Choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. These scans were performed routinely during ground testing. Surprisingly though, the results were not repeatable after the Dewar was warmed and re-cooled but were repeatable when remeasured during the same test campaign. Since the good/bad drive frequencies change during Dewar warmup/cooldown, and possibly after vibration events, the drive frequencies could not be finalized before launch. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

Planning for Validation of Optical Property Degradation Predictions Using On-Orbit Telemetry

NASA’s Gateway Power and Propulsion Element (PPE) will employ high power Xenon Hall thrusters to transit from Earth orbit to a lunar near-rectilinear halo orbit (NRHO). Due to the extended duration of this transit phase and a high thruster duty cycle, there is expected to be significant material erosion caused by the ion plume and subsequent redeposition onto the main spacecraft radiators. While plume modeling and tests of redeposition have attempted to quantify the resulting impact to radiator optical properties, significant uncertainties remain. The flight of PPE presents an opportunity to validate some of the assumptions in this analytical chain, but there will be no specialized hardware that can directly characterize the property changes. However, the planned mission includes periods with significant solar flux to the radiators both early and late in the transit inducing differential heat loads on the vehicle. This presentation will explore options for analyzing possible impacts of various levels of redeposition and whether the severity can be accurately characterized via existing planned telemetry during a nominal mission.

PPE↗

Feasibility Assessment of Magnetohydrodynamic Control for Aerocapture at Neptune

The Planetary Science Decadal Survey released in 2022 posed a mission to one of the Ice Giants as the top priority for flagship missions for NASA. However, current technologies limit the amount of scientific payload available for future Uranian and Neptunian missions due to the need for fuel for orbit insertion maneuvers. Thus, to maximize the scientific potential of future missions, aerocapture has been heavily researched. While aerocapture simulations using only aerodynamic control have proven enabling for capturing around Ice Giants like Neptune, the deep atmospheric pass requires an aeroshell with robust thermal protection systems (TPS). Magnetohydrodynamically controlled (MHD) aerocapture serves as a potential improvement to the limitations of both fully propulsive orbit insertion and aerodynamically controlled aerocapture. Using NASA tools for modeling planetary exploration missions, both the aerodynamic-only and magnetohydrodynamic aerocapture methods were simulated and compared for identical missions to an Ice Giant, with Neptune chosen as the target planet. After applying a guidance algorithm for both methods, the results showed that magnetohydrodynamics has not only the control authority to successfully capture around Neptune, but also the unique advantage of a shallower atmospheric pass, decreasing the maximum heat load and the required TPS mass.

Aerocapture↗

Validation of a Two-Phase CFD Model for Predicting Tank Self-Pressurization in the Ground-Based K-Site Experiment

A two-phase CFD model for self-pressurization of a cryogenic storage tank partially filled with liquid hydrogen is presented using the Volume-Of-Fluid approach for modeling two-phase flow, as well as interfacial heat, mass and momentum transfer between the liquid and the vapor regions. The CFD model is validated against self-pressurization experiment performed using the K-site flightweight hydrogen storage tank at NASA Glenn Research Center1. Laminar and turbulent simulations are performed together with conjugated heat transfer analysis. Effects of turbulence, the value of accommodation coefficient used for predicting phase change rates, as well as tank wall geometry are presented and discussed. Predicted tank pressures, fluid and wall temperatures are compared with the experimental data at 49% fill level and two different heat loads for validating this CFD model.

Computational Fluid Dynamics↗

Impact of Magnetohydrodynamic (MHD) Induced Drag on High Ballistic Coefficient Aerocapture at Neptune

This paper presents analyses illustrating the benefits of magnetohydrodynamic (MHD) drag force control for a capsule performing aerocapture at Neptune relative to the same capsule utilizing conventional aerodynamic-only control across a range of design and flight conditions. MHD technology utilizes an onboard mag-net to create a magnetic field that interacts with the ionized plasma surrounding the capsule at hypersonic velocities, thus creating an electron current and inducing a Lorentz force used to increase capsule drag. The study assumes a 4.57-meterMars Science Laboratory (MSL) 70-degree sphere-cone capsule aerodynamic shape arrives hyperbolically at Neptune and aerocaptures into a synchronous Tri-ton orbit (3986 km x 430,000 km orbit inclined 157 degrees) that offers repeated flyby opportunities. Hyperbolic arrival velocity and the capsule entry mass (i.e., ballistic coefficient) are varied over a wide range of values to study the impact of these variables on key flight performance and sizing parameters. Results show reduced heat rates, heat loads, and thermal protection system mass for MHD cases at all conditions, with the benefit of MHD relative to conventional aerodynamic-only options increasing as ballistic coefficient increases, suggesting the payoff for MHD is significantly better for high-mass entry system design concepts with high ballistic coefficients.

Entry Descent and Landing↗

Validation of a Two-Phase CFD Model for Predicting Tank Self-Pressurization in the Ground-Based K-Site Experiment

A two-phase CFD model for self-pressurization of a cryogenic storage tank partially filled with liquid hydrogen is presented using the Volume-Of-Fluid approach for modeling two-phase flow, as well as interfacial heat, mass and momentum transfer between the liquid and vapor regions. The CFD model is validated against self-pressurization experiment performed using the K-site flightweight hydrogen storage tank at NASA Glenn Research Center 1 . Laminar and turbulent simulations are performed together with conjugate heat transfer analysis. Effects of turbulence, the value of accommodation coefficient used for predicting phase change rates, as well as tank wall geometry are presented and discussed. Predicted tank pressures, fluid and wall temperatures are compared with the experimental data at 49% fill level and two different heat loads for validating this CFD model.

Computational Fluid Dynamics↗

Development of a Thermal Radiator Optimization Tool with Alternate Coolants

The development of a modeling tool to optimize the design of a thermal radiator based on capacity, rejection temperature, geometry, type and coolant is presented. The radiator size is determined from the desired capacity, environmental conditions and rejection temperature. Flow through the radiator is derived from the overall heat load and prescribed inlet to outlet delta temperature for a given coolant. The tool considers radiator geometry (i.e., tube spacing and diameter, face-sheet thickness, overall size, etc.) and general type (i.e., parallel/manifold versus serpentine) in the optimization. Selection from a handful of potential coolants is also available in the tool which primarily affects necessary tube diameter to maintain turbulent flow and minimize pressure drop. An Equivalent System Mass (ESM) approach is utilized to include pump power in the optimization. Results from the tool and potential future enhancements are also discussed.

Coolant↗

Optimization of a Mu2e production solenoid heat and radiation shield using MARS15

A Monte-Carlo study of several Mu2e Production Solenoid (PS) absorber (heat shield) versions using the MARS15 code has been performed. Optimizations for material as well as cost (amount of tungsten) have been carried out. Studied are such quantities as the number of displacements per atom (DPA) in the helium-cooled solenoid superconducting coils, power density and dynamic heat load in various parts of the PS and its surrounding structures. Prompt dose, residual dose, secondary particle flux are also simulated in the PS structures and the experimental hall. A preliminary choice of the PS absorber design is made on the ground of these studies.

43 PARTICLE ACCELERATORS↗

Design and Fabrication of the Lithium Beam Ion Injector for NDCX-II

A 130 keV injector is developed for the NDCX-II facility. It consists of a 10.9 cm diameter lithium doped alumina-silicate ion source heated to {approx}1300 C and 3 electrodes. Other components include a segmented Rogowski coil for current and beam position monitoring, a gate valve, pumping ports, a focusing solenoid, a steering coil and space for inspection and maintenance access. Significant design challenges including managing the 3-4 kW of power dissipation from the source heater, temperature uniformity across the emitter surface, quick access for frequent ion source replacement, mechanical alignment with tight tolerance, and structural stabilization of the cantilevered 27-inch OD graded HV ceramic column. The injector fabrication is scheduled to complete by May 2011, and assembly and installation is scheduled to complete by the beginning of July. The Neutralized Drift Compression eXperiment (NDCX-II) is for the study of high energy density physics and inertial fusion energy research utilizing a lithium ion (Li+) beam with a current of 93 mA and a pulse length of 500 ns (compressed to 1 ns at the target). The injector is one of the most complicated sections of the NDCX-II accelerator demanding significant design and fabrication resources. It needs to accommodate a relatively large ion source (10.9 cm), a high heat load (3-4 kW) and specific beam optics developed from the physics model. Some specific design challenges are noted in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helium release rates and ODH calculations from RHIC magnet cooling line failure

A catastrophic failure of the magnet cooling lines, similar to the LHC superconducting bus failure incident, could discharge cold helium into the RHIC tunnel and cause an Oxygen Deficiency Hazard (ODH) problem. A SINDA/FLUINT{reg_sign} model, which simulated the 4.5K/4 atm helium flowing through the magnet cooling system distribution lines, then through a line break into the insulating vacuum volumes and discharging via the reliefs into the RHIC tunnel, had been developed. Arc flash energy deposition and heat load from the ambient temperature cryostat surfaces are included in the simulations. Three typical areas: the sextant arc, the Triplet/DX/D0 magnets, and the injection area, had been analyzed. Results, including helium discharge rates, helium inventory loss, and the resulting oxygen concentration in the RHIC tunnel area, are reported. Good agreement had been achieved when comparing the simulation results, a RHIC sector depressurization test measurement, and some simple analytical calculations.

43 PARTICLE ACCELERATORS↗

Progress in cavity and cryomodule design for the Project X linac

The continuous wave 3 GeV Project X Linac requires the development of two families of cavities and cryomodules at 325 and 650 MHz. The baseline design calls for three types of superconducting single-spoke resonators at 325 MHz having betas of 0.11, 0.22, and 0.42 and two types of superconducting five-cell elliptical cavities having betas of 0.61 and 0.9. These cavities shall accelerate a 1 mA H- beam initially and must support eventual operation at 4 mA. The electromagnetic and mechanical designs of the cavities are in progress and acquisition of prototypes is planned. The heat load to the cryogenic system is up to 25 W per cavity in the 650 MHz section, thus segmentation of the cryogenic system is a major issue in the cryomodule design. Designs for the two families of cryomodules are underway.

43 PARTICLE ACCELERATORS↗

Instrumentation status of the low-b magnet systems at the Large Hadron Collider (LHC)

The low-{beta} magnet systems are located in the Large Hadron Collider (LHC) insertion regions around the four interaction points. They are the key elements in the beams focusing/defocusing process allowing proton collisions at luminosity up to 10{sup 34}cm{sup -2}s{sup -1}. Those systems are a contribution of the US-LHC Accelerator project. The systems are mainly composed of the quadrupole magnets (triplets), the separation dipoles and their respective electrical feed-boxes (DFBX). The low-{beta} magnet systems operate in an environment of extreme radiation, high gradient magnetic field and high heat load to the cryogenic system due to the beam dynamic effect. Due to the severe environment, the robustness of the diagnostics is primordial for the operation of the triplets. The hardware commissioning phase of the LHC was completed in February 2010. In the sake of a safer and more user-friendly operation, several consolidations and instrumentation modifications were implemented during this commissioning phase. This paper presents the instrumentation used to optimize the engineering process and operation of the final focusing/defocusing quadrupole magnets for the first years of operation.

43 PARTICLE ACCELERATORS↗

Dynamic Resistance of YBCO-Coated Conductors in Applied AC Fields with DC Transport Currents and DC Background Fields

In order to predict heat loads in future saturable core fault-current-limiting devices due to ac fringing fields, dynamic resistance in YBCO-coated conductors was measured at 77 K in peak ac fields up to 25 mT at 60 Hz and in dc fields up to 1 T. With the sample orientation set such that the conductor face was either parallel or perpendicular to the ac and dc applied fields, the dynamic resistance was measured at different fractions of the critical current to determine the relationship between the dc transport current and the applied fields. With respect to field orientation, the dynamic resistance for ac fields that were perpendicular to the conductor face was significantly higher than when the ac fields were parallel to the conductor face. It was also observed that the dynamic resistance: (1) increased with increasing fraction of the dc transport current to the critical current, (2) was proportional to the inverse of the critical current, and (3) demonstrated a linear dependence with the applied ac field once a threshold field was exceeded. This functional behavior was consistent with a critical state model for the dynamic resistance, but discrepancies in absolute value of the dynamic resistance suggested that further theoretical development is needed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Helium pressures in RHIC vacuum cryostats and relief valve requirements from magnet cooling line failure

A catastrophic failure of the RHIC magnet cooling lines, similar to the LHC superconducting bus failure incident, would pressurize the insulating vacuum in the magnet and transfer line cryostats. Insufficient relief valves on the cryostats could cause a structural failure. A SINDA/FLUINT{reg_sign} model, which simulated the 4.5K/4 atm helium flowing through the magnet cooling system distribution lines, then through a line break into the vacuum cryostat and discharging via the reliefs into the RHIC tunnel, had been developed to calculate the helium pressure inside the cryostat. Arc flash energy deposition and heat load from the ambient temperature cryostat surfaces were included in the simulations. Three typical areas: the sextant arc, the Triplet/DX/D0 magnets, and the injection area, had been analyzed. Existing relief valve sizes were reviewed to make sure that the maximum stresses, caused by the calculated maximum pressures inside the cryostats, did not exceed the allowable stresses, based on the ASME Code B31.3 and ANSYS results. The conclusions are as follows: (1) The S/F simulation results show that the highest internal pressure in the cryostats, due to the magnet line failure, is {approx}37 psig (255115 Pa); (2) Based on the simulation, the temperature on the cryostat chamber, INJ Q8-Q9, could drop to 228 K, which is lower than the material minimum design temperature allowed by the Code; (3) Based on the ASME Code and ANSYS results, the reliefs on all the cryostats inside the RHIC tunnel are adequate to protect the vacuum chambers when the magnet cooling lines fail; and (4) In addition to the pressure loading, the thermal deformations, due to the temperature decrease on the cryostat chambers, could also cause a high stress on the chamber, if not properly supported.

43 PARTICLE ACCELERATORS↗

Multi-Fluid Modeling of Low-Recycling Divertor Regimes

The low-recycling regimes of divertor operation in a single-null NSTX magnetic configuration are studied using computer simulations with the edge plasma transport code UEDGE. The edge plasma transport properties pertinent to the low-recycling regimes are demonstrated. These include the flux-limited character of the parallel heat transport and the high plasma temperatures with the flattened profiles in the scrape-off-layer. It is shown that to maintain the balance of particle fluxes at the core interface the deuterium gas puffing rate should increase as the divertor recycling coefficient decreases. The radial profiles of the heat load to the outer divertor plate, the upstream radial plasma profiles, and the effects of the cross-field plasma transport in the low-recycling regimes are discussed. It is also shown that recycling of lithium impurities evaporating from the divertor plate at high surface temperatures can reverse the low-recycling divertor operational regime to the high-recycling one and may cause thermal instability of the divertor plate. (C) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗