Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Electrical substation grid testbed for DLT applications of electrical fault detection, power quality monitoring, DERs use cases and cyber-events

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation, and are associated with customer-owned distributed energy resources (DERs). The integrity and confidentiality of data from these IEDs, like power meters and protective relays, is crucial. Blockchain technology could improve the resilience of microgrids by improving the security of data sharing. The penetration of customer-owned DERs (renewable energy sources) and the increasing deployment of IEDs can lead to integrate power system applications with Distributed Ledger Technology (DLT). In this study, we implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in-the-loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results had shown the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, the ESGT with DERs and the CGG system will be used in other power system applications, based on implementing smart contracts between electrical utilities with customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning-Based Demand Response in Grid Interactive Buildings via Gaussian Processes

This paper presents a predictive controller for a grid-interactive multi-zone building where the temperature dynamics are learned via Gaussian Process (GP) regression. We investigate the development of a learning-based predictive control with two main objectives: (i) continuously learn the temperature dynamics of the building based on data; and, (ii) use the learned dynamics to solve a multi-objective predictive control problem to guarantee occupants' comfort and energy efficiency during normal conditions and demand response events. We leverage the probabilistic non-parametric properties of GPs to estimate the (unknown) non-linear temperature dynamics of the building and to incorporate the uncertainty of those predictions in a multi-objective optimization problem. The GP-based predictive control is solved via a zero-order primal-dual projected-gradient algorithm. We evaluate numerically the performance of the proposed controller using a five-zone commercial building.

demand response↗

PART 1- techno-economic analysis of a grid scale Ground-Level Integrated Diverse Energy Storage (GLIDES) technology

In this paper, a techno-economic model / cost reduction analysis of a low-cost, dispatchable / scalable, efficient Ground-Level Integrated Diverse Energy Storage (GLIDES) system is analyzed, along with a review of existing state-of-the-art energy storage technologies. The introduced technology, GLIDES, which was invented at the Oak Ridge National Laboratory (ORNL), stores energy by compression and expansion of air using water as a liquid piston inside high-pressure reservoirs. GLIDES is introduced by combining Pumped Hydroelectric Storage (PHS) and Compressed Air Energy Storage (CAES) technologies. Here, by replacing inefficient gas compressor and turbine with higher efficiency liquid turbomachines for liquid-piston compression/expansion, GLIDES achieves higher roundtrip efficiency than other gas compression-based energy storage technologies and is a scalable energy storage system. For cost reduction purposes, various pressure reservoirs including steel vessels, carbon fiber vessels, pipe segments, and underground pressure reservoirs are analyzed in this paper. Based on the analyzed data using the models discussed in this paper, energy storage costs as low as ~$14/kWh and ~346/kWh (roundtrip efficiency (RTE) ~80%) can be achieved for a grid-scale GLIDES using depleted oil/gas reservoirs and high-pressure pipe segments respectively.

25 ENERGY STORAGE↗

End-To-End Decentralized Transmission Line Protection in IBR-Dominated Weak Grids Using Interpretable Data-Driven Methods

Traditional transmission line protection relies on predictable synchronous-based fault signatures, which frequently fail under the non-standard, current-limited fault characteristics of Inverter-Based Resources (IBRs). This study investigates how to achieve secure, communication-free fault isolation in IBR-dominated weak grids without relying on opaque, computationally heavy "black-box" machine learning algorithms. To address this, we propose a novel, standalone, and inherently interpretable data-driven protection framework. Unlike centralized methods requiring multi-terminal communication, this decentralized approach relies solely on local measurements using a hierarchical linear-kernel Support Vector Machine (SVM). The methodology decomposes the protection task into four sequential stages that mimic traditional protection elements: fault detection and fault direction identification, fault type classification, zone classification, and location estimation. This multi-stage architecture allows for specialized feature engineering at each stage, combining high computational efficiency with logic traceability. The framework's end-to-end performance was validated via C-code and PSCAD/EMTDC co-simulation, utilizing a real-world utility network and an OEM black-box IBR model. The proposed relay achieves 97.2% overall accuracy and provides a reliable trip decision within a 2.5-cycle window. The results confirm 100% accuracy in fundamental fault detection, reliable zone selectivity across low to moderate fault resistances, and robust security against non-fault transients, proving its immediate viability for integration into commercial numerical relays.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-responsive hydrogen production: Capital utilization and current density vs. efficiency in variable electricity markets

To achieve low-cost hydrogen production from water electrolyzers, grid tied electrolysis may need to operate dynamically to minimize the cost of supplying energy to the electrolyzer stack and produce hydrogen during low-cost hours and turn off/down during high-cost hours. Operating systems in this way can decrease capital utilization (capacity factor) and electricity costs. This strategy would shift the dominant cost drivers away from electricity (and thus efficiency) to the capital costs of the system, due to the underutilized capital when operating at low-capacity factors. Increasing the operational current density of the system could, in effect, reduce the capital cost of the system while producing hydrogen at a lower efficiency on a per unit energy basis. In the variable electricity cost profiles analyzed in this paper, increasing the current density for liquid alkaline from 0.5 A/cm2 to 1.5 Ac/m2 and proton exchange membrane electrolyzers from 2 A/cm2 to 4 A/cm2 resulted in substantial reductions in the levelized cost of hydrogen. Additionally, as capacity factors and electricity costs decrease, the optimal operating current density of the electrolyzer systems analyzed increases. These findings suggest R&D efforts should focus on increasing the operational current densities, reducing the turn down ratios, and understanding the durability implications of those strategies on low-temperature liquid alkaline and proton exchange membrane electrolyzers.

08 HYDROGEN↗

Computation of magnetic fields from field components on a plane grid

An algorithm is presented to calculate the field components of the magnetic field [B x (x, y, z), B y (x, y, z), B z (x, y, z)] at a point (x, y, z) in space, from the knowledge of the components [B x (x, y) = 0, z), B y (x, y = 0, z), B z (x, y = 0,z)] on a “reference plane”, which is normal to the y-axis at . The algorithm, which is a general one and is not restricted to fields with mid-plane symmetry is based on the Maclaurin series expansion of the magnetic field components at any point in space in terms of the distance (y) of the point from the reference plane. The coefficients of the Maclaurin series expansion are expressed in terms of the on-plane field components and their partial derivatives with respect to spatial coordinates (). The field components are usually generated from magnetic field measurements on a rectangular grid on the plane. This algorithm was employed in 1986 in the RAYTRACE computer code to help calculate the optical properties of magnets and of the Alternating Gradient Synchrotron (AGS) at the Brookhaven National Laboratory (BNL). Here, a general mathematical formulation of this algorithm based on the differential algebraic method was presented by Makino in 2011. This paper presents the step by step derivation of the algorithm and provides the necessary formulas to be introduced by the reader in any computer code which requires the field components generated by magnetic devices. In addition provides an example of the use of the algorithm and its limitations as applied to a Halbach type magnet with or without median plane symmetry.

43 PARTICLE ACCELERATORS↗

A high order Cartesian grid, finite volume method for elliptic interface problems

We present a higher-order finite volume method for solving elliptic PDEs with jump conditions on interfaces embedded in a 2D Cartesian grid. Second, fourth, and sixth order accuracy is demonstrated on a variety of tests including problems with high-contrast and spatially varying coefficients, large discontinuities in the source term, and complex interface geometries. We include a generalized truncation error analysis based on cell-centered Taylor series expansions, which then define stencils in terms of local discrete solution data and geometric information. In the process, we develop a simple method based on Green's theorem for computing exact geometric moments directly from an implicit function definition of the embedded interface. This approach produces stencils with a simple bilinear representation, where spatially-varying coefficients and jump conditions can be easily included and finite volume conservation can be enforced.

97 MATHEMATICS AND COMPUTING↗

Dynamics of disordered intermediates during the two-electron alkaline MnO 2 conversion reaction for grid-scale batteries

Battery technologies beyond Li-ion are likely needed for extensive integration of grid-scale storage. The rechargeable Zn-MnO 2 chemistry has the potential for high sustainability, high safety, and low cost, using Earth-abundant basis materials. In an alkaline electrolyte, the MnO 2 cathode can cycle reversibly if modified by including a Bi-containing additive, although the cycling mechanism remains mostly unknown. This work presents an account of the intermediate species involved in the electrochemical transformation from layered δ-MnO 2 to Mn(OH) 2 and back. During charge, a disordered intermediate with a structure resembling layered β-MnOOH exists stably for an extended period, corresponding to a regime known to have unexpected electrochemical activity of Bi. During discharge, β-MnOOH exists only briefly and is never the majority material, revealing that the cycling mechanism is asymmetric. In conclusion, these findings represent a significant advance in mechanistic knowledge and can enable engineering to develop the system for commercial use.

36 MATERIALS SCIENCE↗

Energy-water interdependencies across the three major United States electric grids: A multi-sectoral analysis

As water availability and timing of delivery fluctuates and the US electric grid sees rapid transformation and reconfiguration under decarbonization and resource adequacy strategies, there is a critical need for information and data that supports understanding the water-energy interdependency landscape. The United States currently lacks comprehensive data, informative visualizations, and analysis of energy-water interdependencies at scales necessary to support resource and operational decision-making. This article provides US electricity interconnection-level Sankey diagrams that show the relative reliance of water and energy across various economic sectors. A deeper analysis is additionally provided at the county level to illustrate trends and potential opportunities related to resiliency and efficiency in multi-sectoral water and energy flow distributions and intensities. We find that the electricity interconnections in the US vary dramatically in their water and energy interdependencies across applications and economic sectors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

3x3 array module of 8×8×32 mm 3 position-sensitive virtual frisch-grid CdZnTe detectors for imaging and spectroscopy of cosmic gamma-rays

Here, we evaluated the performance of the 3x3 array of 32-mm long position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors read out by the IDEAS GDS-100 data acquisition system. The array is a mechanically solid module designed for integration into a large effective area gamma-ray telescope proposed for imaging and spectroscopy of cosmic gamma-rays. The array employs the bar-shaped 8x8x32 mm 3 CZT crystals which recently became available from Redlen Technologies, Inc. and Kromek-eV Group PLC at affordable costs. The waveform sampling IDE3421 application-specific integrated circuit (ASIC), developed by the University of Michigan and IDEAS for CZT pixel detectors, was adapted to capture the signals from the array's VFG detectors. We showed good spectral performance of the Redlen detectors with an energy resolution of <1% FWHM at 662 keV and slightly poorer performance of the Kromek-eV detectors with a resolution of <2% measured at a reduced temperature of 13 °C. By testing the same detectors as single devices using hybrid charge-sensitive preamplifiers, we demonstrated improved energy resolutions at a normal temperature of ~25°C: <1% and 1.3-1.7%, respectively. However, the Kromek-eV detectors did not perform as well as the Redlen ones. We explained this by the space charge formation (polarization) decreasing the electric field and the electron drift times. The polarization was likely caused by the high injections of holes from the anode contacts. The absence of polarization in Redlen detectors suggested that the quality of the contacts might have played a role in this case.

47 OTHER INSTRUMENTATION↗

Algorithms for coordinate reconstruction in position-sensitive virtual Frisch-grid detectors

Arrays of position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors provide a cost-effective solution for integrating large-area arrays for gamma-ray imaging and spectroscopy. These detectors employ high-aspect ratio CZT crystals (bars) with thicknesses up to 50 mm and cross-sections of up to 10 × 10 mm 2 . Despite the long drift distances of charge carriers in such crystals, the detectors have demonstrated excellent performance, achieving energy resolutions better than 1 % full width at half maximum (FWHM) at 662 keV and 3D position resolutions finer than 1 mm. The high spatial resolution is a critical feature of these detectors, as it enables correction of response non-uniformities caused by crystal defects, which remain present even in the highest-quality CZT material. Dislocations and dislocation walls are the primary defects responsible for variations in charge carrier losses as they drift from the interaction points toward the charge-collecting electrodes. The mechanism by which these defects affect carrier transport is generally well understood. Dislocations and sub-grain boundaries act as sinks for carrier-trapping centers, primarily impurities and secondary phases such as tellurium inclusions and precipitates. Here, these regions exhibit significantly higher carrier-trapping rates, leading to variations in the μτ-products. Because the locations of these micron-sized regions are fixed within the detector volume, fluctuations in the total collected charge arise from the random distribution of interaction sites. This results in non-uniform detector responses and degradation of energy resolution. However, by measuring the interaction-site locations with sufficient precision, charge-loss variations can be accurately corrected, allowing recovery of nearly intrinsic energy resolution.

47 OTHER INSTRUMENTATION↗

Minimizing grid energy consumption in wastewater treatment plants: Towards green energy solutions, water sustainability, and cleaner environment

Wastewater treatment plants (WWTPs) consume significant amount of energy to sustain their operation. From this point, the current study aims to enhance the capacity of these facilities to meet their energy needs by integrating renewable energy sources. The study focused on the investigation of two primary solar energy systems in As Samra WWTP in Jordan. The first system combines parabolic trough collectors (PTCs) with thermal energy storage (TES). This system primarily serves to fulfill the thermal energy demands of the plant by reducing the demands from boiler units, which allows more biogas for electricity generation. The second system is a photovoltaic (PV) system with Lithium-Ion batteries, which directly produces electricity that will be used to cover part of the electrical energy demands of plant. To assess the optimal configuration, two distinct scenarios have been formulated and compared to the current case scenario (SC#1). The first scenario focuses on maximizing the net present value (NPV) and minimizing the levelized cost of electricity (LCOE). The second scenario is centred on minimizing the levelized cost of heat (LCOH). The findings indicate that both scenarios succeeded in reducing the reliance on the grid to a value that reach 1 %. Moreover, they both reduced biogas percentage in energy production from 88 % to approximately 65 % through the integration of the PV system. In terms of thermal demand, SC#2 reduced the reliance on biogas boiler units from 100 % to 25 %, while SC#3 achieved an even more impressive reduction to just 8 %. The best LCOE value was attained in SC#2, at 0.0895 USD/kWh, with an NPV of 10.54 million USD. Conversely, SC# 3 yielded an LCOH value of 0.0432 USD/kWh th compared to 0.0534 USD/kWh th USD for SC#2. In conclusion, despite their relatively high capital and operating costs, SC#2 and SC#3 managed to substantially decrease the annual electricity expenditure from approximately 2 million USD to 86,000 USD and 0 USD, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System benefits of industrial battery storage: A comparison of grid and facility control and dispatch

Customer-owned, distributed battery installations are being incentivized by utilities to increase installed battery capacity. In many of these incentive agreements, the battery owner relinquishes battery control to the utility in exchange for incentive money. The industrial sector has lagged in storage installation when compared to the residential and commercial sectors. This study compares the economic advantages to utilities and industrial facilities in different dispatch control situations. The study presents a novel framework for the optimization of multiple systems using load profiles from the industrial, residential, and commercial sectors. Case studies are presented to illustrate different dispatch scenarios. Further, the simulations showed more fiscal benefit for the industrial facilities to dispatch the battery for electrical demand reduction than utility dispatch. In the case studies, facility dispatch control resulted in an increase of facility savings by a factor of about 8.7 when compared to utility dispatch. Battery size plays a significant factor on the impact of the grid’s generating costs, showing that larger batteries can provide significant benefit even if dispatched by the facility. Future policies concerning industrial battery installations should consider overall economic benefits to utility and facility in the form of rate structures and incentive participation based on battery size.

25 ENERGY STORAGE↗

Accelerating room air conditioner efficiency in India: Grid, economic, and policy implications through 2035

India is poised for a rapid surge in space cooling demand, driven by rising incomes, urbanization, and intensifying heat. Between 2025 and 2035, the country is expected to add 130–150 million new room air conditioners (ACs). If Minimum Energy Performance Standards (MEPS) continue to improve at the historical rate of 2–3 % annually, room ACs alone could contribute over 180 GW to peak electricity demand by 2035-nearly 30 % of the projected national total. This study evaluates the impact of an accelerated MEPS trajectory, proposing to raise the 1-star threshold to ISEER 5.0 by 2027, ISEER 6.3 by 2030, and ISEER 7.4 by 2033. Drawing on engineering cost analysis, stock turnover modeling, and retail pricing data, we find that this pathway could reduce peak demand by over 60 GW, save 118 TWh of electricity annually, avoid 49 MtCO₂ of electricity-related emissions per year, avert ₹7.5 trillion (∼US$85 billion) in power system investments, and yield ₹0.7–2.3 trillion (∼US$8–26 billion) in net consumer savings by 2035. Contrary to affordability concerns, empirical trends show that higher efficiency does not increase AC prices. These results highlight the value of ambitious MEPS as a cost-effective strategy for improving grid reliability, reducing emissions, and advancing consumer welfare in emerging economies.

Abhyankar, Nikit↗

Impacts and emerging research opportunities in Vehicle-Grid Integration for transportation: A review

This review provides a comprehensive examination of Vehicle-Grid Integration (VGI) technologies and their impacts on transportation systems, with a particular emphasis on the transportation-energy nexus. It systematically explores how VGI affects key transportation applications such as charging infrastructure planning, electric vehicle (EV) routing, smart charging coordination, shared mobility, and dynamic pricing. By synthesizing recent literature from both transportation and energy systems perspectives, this study highlights how advanced methodologies, such as reinforcement learning, game theory, and optimization techniques, are used to model the complex interactions between EVs, mobility patterns, and distributed energy systems. Furthermore, the review also identifies critical challenges, including behavioral factors, data limitations, and system scalability. Drawing on these insights, the paper outlines emerging research opportunities to support the design of integrated, resilient, and user-centric VGI solutions that advance sustainable mobility and energy system efficiency.

Charging coordination↗

A Free-Standing Boron-Doped Diamond Grid Electrode for Fundamental Spectroelectrochemistry

Spectroelectrochemistry (SEC) is a powerful technique that enables a variety of redox properties to be studied, including formal potential (E o ), thermodynamic values (ΔG, ΔH, ΔS), diffusion coefficient (D), electron transfer stoichiometry (n), and others. SEC requires an electrode which light can pass through while maintaining sufficient electrical conductivity. This has been traditionally composed of metal or metal oxide films atop transparent substrates like glass, quartz, or metallic mesh. Robust electrode materials like boron-doped diamond (BDD) could help expand the environments in which SEC can be performed, but most designs are limited to thin films (~100–200 nm) on transparent substrates less resilient than free-standing BDD. Here, this work presents a free-standing BDD grid electrode (G-BDD) for fundamental SEC measurements, using the well-characterized Fe(CN) 6 3–/4– redox couple as proof-of-concept. With a combination of cyclic voltammetry (CV), thin-layer SEC, and chronoabsorptometry, several of the redox properties mentioned above were calculated and compared. For E o' , n, and D, similar results were obtained when comparing the CV [E o' = +0.279 (±0.002) V vs Ag/AgCl; n = 0.97; D = 4.1 × 10 –6 cm 2 ·s –1 ] and SEC [E o' = +0.278 (±0.001) V vs Ag/AgCl; n = 0.91; D = 5.2 × 10 –6 cm 2 ·s –1 ] techniques. Both values align with what has been previously reported. To calculate D from the SEC data, modification of the classical equation used in chronoabsorptometry was required to accommodate the G-BDD electrode geometry. Overall, this work expands on the applicability of SEC techniques and BDD as a versatile electrode material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Promises and Challenges of Next-Generation “Beyond Li-ion” Batteries for Electric Vehicles and Grid Decarbonization

The tremendous improvement in performance and cost of lithium-ion batteries (LIBs) have made them the technology of choice for electrical energy storage. While established battery chemistries and cell architectures for Li-ion batteries achieve good power and energy density, LIBs are unlikely to meet all the performance, cost, and scaling targets required for energy storage, in particular, in large-scale applications such as electrified transportation and grids. The demand to further reduce cost and/or increase energy density, as well as the growing concern related to natural resource needs for Li-ion have accelerated the investigation of so-called "beyond Li-ion" technologies. In this review, we will discuss the recent achievements, challenges, and opportunities of four important "beyond Li-ion" technologies: Na-ion batteries, K-ion batteries, all-solid-state batteries, and multivalent batteries. Here, the fundamental science behind the challenges, and potential solutions toward the goals of a low-cost and/or high-energy-density future, are discussed in detail for each technology. While it is unlikely that any given new technology will fully replace Li-ion in the near future, "beyond Li-ion" technologies should be thought of as opportunities for energy storage to grow into mid/large-scale applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AC Magnetometry Using Nano-ferrofluid Cladded Multimode Interferometric Fiber Optic Sensors for Power Grid Monitoring Applications

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored. Instead, the incorporation of nano-ferrofluid as sensing materials has been only limited to DC magnetic field sensing, often citing their long response time as a limiting factor to AC field sensing. This work reports the finding of high frequency (up to 15 kHz) AC magnetic field sensing capability of nanomagnetic fluid as the cladding material of a fiber-optic multimode interferometry (MMI) structure optimized for the fourth self-imaging spectral response. The key parameter enabling high frequency response is the short response time (<1 ms) achieved by optimizing both the sensing structure and nano-ferrofluid solution. Focus has been imparted on 60 Hz line-frequency profiles of various current/magnetic fields to test the efficacy of these sensors in metering and monitoring current and current-induced magnetic fields in the electrical power grid systems. The magnetic field sensitivity of 240 mV/Gauss per dBm of transmitted power was achieved for 60 Hz field applied via Helmholtz coil, whereas the 60 Hz AC current sensitivity of 2.83 mV/A was measured due to magnetic field induced by current in a straight conducting wire.

42 ENGINEERING↗