Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GUIDANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

In vivo pharmacokinetic enhancement of monomeric Fc and monovalent bispecific designs through structural guidance

In a biologic therapeutic landscape that requires versatility in targeting specificity, valency and half-life modulation, the monomeric Fc fusion platform holds exciting potential for the creation of a class of monovalent protein therapeutics that includes fusion proteins and bispecific targeting molecules. Here we report a structure-guided approach to engineer monomeric Fc molecules to adapt multiple versions of half-life extension modifications. Co-crystal structures of these monomeric Fc variants with Fc neonatal receptor (FcRn) shed light into the binding interactions that could serve as a guide for engineering the half-life of antibody Fc fragments. These engineered monomeric Fc molecules also enabled the generation of a novel monovalent bispecific molecular design, which translated the FcRn binding enhancement to improvement of in vivo serum half-life.

59 BASIC BIOLOGICAL SCIENCES↗

Vortex guidance and transport in channeled pinning arrays

Here, we numerically examine vortices interacting with pinning arrays where a portion of the pinning sites have been removed in order to create coexisting regions of strong and weak pinning. The region without pinning sites acts as an easy-flow channel. For driving in different directions with respect to the channel, we observe distinct types of vortex flow. When the drive is parallel to the channel, the flow first occurs in the pin free region followed by a secondary depinning transition in the pinned region. At high vortex densities there is also an intermediate plastic flow phase due to the coupling between the weak and strong pinning regions. For driving applied perpendicular to the channel, we observe a jammed phase in which vortices accumulate on the boundary of the pinned region due to the vortex-vortex repulsion, while at higher drives the vortices begin to flow through the pinning array. For driving at an angle to the channel, depending on the filling we observe a drive-induced reentrant pinning effect as well as negative differential mobility which occurs when vortices move from the unpinned to the pinned portion of the sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Guidance for Developing Digital Twins for Online Condition Monitoring of Nuclear Power Plant Components

Online condition monitoring is an area of active research that may enable optimized scheduling, maintenance, and safety of nuclear power plant components, reducing unnecessary derates while simultaneously improving operational capacity. Digital twins (DTs) are one avenue to conduct online condition monitoring and are currently being explored by national laboratories and universities alike. DTs for online condition monitoring are, in essence, state concurrent models that emulate a physical process which predicts a parameter and compares it against a measured value. The promise of DT is that they may provide additional insights by combining and interpreting various sources of information and may be used for preventative maintenance scheduling optimization or early fault detection. DTs for condition monitoring are projected to be valuable for meeting requirements under 10 CFR 50.55a and 10 CFR 50.65. However, DT technologies are still under significant development and the process for developing a DT for condition monitoring has not been formalized. Therefore, in this work, we present an initial framework for developing a DT, discuss and review the various challenges and considerations for DT deployment, and identify the opportunities that a DT can improve. Here, the presented framework is intended to help developers formulate a strategy when approaching DT development for condition monitoring. A DT use case for a reactor coolant pump is presented to demonstrate the proposed framework.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

The increasing threat of Rift Valley fever virus globalization: strategic guidance for protection and preparation

Rift Valley fever virus (RVFV) (Bunyavirales: Phlebovirus) is a prominent vector-borne zoonotic disease threat to global agriculture and public health. Risks of introduction into nonendemic regions are tied to changing climate regimes and other dynamic environmental factors that are becoming more prevalent, as well as virus evolutionary factors and human/animal movement. Endemic to the African continent, RVFV has caused large epizootics at the decadal scale since the early 20th century but has spread to the Arabian Peninsula and shows increasing patterns of interepizootic transmission on the annual scale. This virus can be transmitted by mosquitoes as well as through direct contact with infected tissues and can cause sporadic to widespread morbidity and mortality in domestic ungulate livestock as well as humans. High viremias in infected livestock moved for legal and illegal trade as well as in infected mosquitoes or human travelers can spread this virus worldwide. With increasing global commerce, it is likely RVFV will be introduced to new areas with suitable hosts, mosquito vector species, and environments. However, the strong mosquito component of RVFV epidemiology combined with advancements in vaccines, diagnostics, and virus evolutionary factors create opportunities for strategies to leverage models of connectivity among potential source and emerging regions to target surveillance and mitigation activities to reduce the risk of RVFV introduction, or contain the virus should it be introduced, into new regions.

60 APPLIED LIFE SCIENCES↗

Optical Interference for the Guidance of Cryogenic Focused Ion Beam Milling Beyond the Axial Diffraction Limit

Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labelled structures with accuracy beyond the diffraction limit. We demonstrate the approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of water. Here, we then apply the approach to capture virions inside host cells. Successful targeting is confirmed by cryogenic electron tomography revealing clusters of virions in intracellular vesicles.

Sica, Anthony V. [SLAC National Accelerator Labora↗

Soliton motion in skyrmion chains: Stabilization and guidance by nanoengineered pinning

Using a particle-based model we examine the depinning motion of solitons in skyrmion chains in quasi-one-dimensional (1D) and two-dimensional (2D) systems containing embedded 1D interfaces. Here, the solitons take the form of a particle or hole in a commensurate chain of skyrmions. Under an applied drive, just above a critical depinning threshold, the soliton moves with a skyrmion Hall angle of zero. For higher drives, the entire chain depins, and in a 2D system we observe that both the solitons and chain move at zero skyrmion Hall angle and then transition to a finite skyrmion Hall angle as the drive increases. In a 2D system with a 1D interface that is at an angle to the driving direction, there can be a reversal of the sign of the skyrmion Hall angle from positive to negative. Our results suggest that solitons in skyrmion systems could be used as information carriers in racetrack geometries that would avoid the drawbacks of finite skyrmion Hall angles. The soliton states become mobile at significantly lower drives than the depinning transition of the skyrmion chains themselves.

36 MATERIALS SCIENCE↗

Reliable LED Lighting Technologies: Key Factors and Procurement Guidance

Abstract— Lighting systems have the ability to transform the economic and educational infrastructure of disadvantaged communities, and eradicating “light poverty” has become one of the primary goals of the International Year of Light 2015. Solid-state lighting (SSL) technology, based on light-emitting diode (LED) light sources, has emerged as the next generation of lighting technology, with a current global market penetration of roughly 5%. This paper will report on recent research on understanding SSL lighting system reliability (failure modes, environmental stressors, electrical power quality); discuss the implications of SSL technology reliability for providing lighting services; and suggest practical approaches to ensure SSL reliability to benefit humanity. Among the key findings from this work is that LED sources can be extremely reliable, withstanding a broad range of environmental stresses without failure. Nonetheless, SSL lighting systems can have a negative impact on electrical power reliability, as well as on the affordability of lighting services, without attention to the quality of the accompanying power infrastructure. It is therefore critical to ensure that the performance of the power supply electronics used in lighting systems is matched to the quality of the power source, when evaluating energy efficient lighting choices.

Davis, Lynn↗

Full Scale 3D Computational Model of the Industrial -Scale Coal Fired Boiler Performance for Temperature Sensor Installation Guidance

Abstract Nearly 30% of the electricity is generated by using coal as the primary fuel in the US. One of the major concerns in coal-fired power plants is the failure of boiler tubes that leads to unscheduled maintenance and has a huge economical and societal impact. High temperature flue gas along with ash pass over the boiler tubes, which over time leads to tube failure. Therefore, developing temperature sensors for harsh environments and install them for temperature sensing and boiler tube lifetime prediction is an urgent need. On the side of sensor development, the location of the sensor installation is important for stable sensing performance and easy calibration. In this study, computational fluid dynamics and heat transfer modeling are adopted to establish a full-scale 3-dimensional model of a coal-fired boiler to investigate the flue gas temperature distribution within the boiler and identify the proper locations for sensor installation. We proposed three criteria to select the temperature sensor installation location: (1) select the boiler tube panel away from the sidewalls, (2) select the boiler tube section closer to the top wall of the boiler; and (3) select the boiler tube on the back of the boiler panel (not directly facing the flue gas flow). In these regions, the flue gas temperature is stable, providing an ideal environment for stable temperature sensing and calibration.

Gupta, Tanuj↗

Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: A preliminary performance study

Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For the static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0.8 {+-} 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 {+-} 1.3 mm) vs without interference (1.0 {+-} 0.7 mm, p < 0.001). An accuracy of 1.6 {+-} 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 {+-} 0.5 mm) was significantly higher than that in AP direction (0.3 {+-} 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 {+-} 0.2 mm vs 1.3 {+-} 0.2 mm at 80 Hz and 0.9 {+-} 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 {+-} 0.2 mm was obtained for the dynamic tracking when using optimum configuration. Conclusions: The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-244: Validation of a 6D-Robotic-Couch and Image Guidance Radiation Therapy (IGRT) System for Localization in World's First Single-Room Proton Therapy System

Purpose: The Mevion S250 proton therapy unit is equipped with a 6D-robotic couch and IGRT system (Verity). The patient alignment process allows corrections in six degrees of freedom: translation (x,y,z), pitch, roll, and yaw (θ,ϑ,ψ). Geometric accuracy of couch corrections and imaging vs. radiation isocenter coincidence were quantified before clinical implementation. Methods: A commercial phantom with sixteen 2mm tungsten BBs was rigidly couch-mounted and imaged with CT. Seventeen rigid translations/rotations of known magnitude were digitally applied to the original CT image using commercial software, validated with Varian OBI system. For each altered image, phantom was mounted on robotic couch in original position, then Verity 2D:2D match (PA-LLAT) was performed using DRRs from altered images. Corrections were recorded and applied, phantom was imaged a second time and residual corrections recorded. Physical measurements verified that applied couch corrections coincided with both physical couch shifts/rotations and known CT image translations/rotations. Additionally, image vs. radiation isocenter coicidence was quantified over couch treatment angles (±90° from setup position) using radiochromic film and an image-guided couch star-shot. Posterior-anterior and left-lateral kV radiographs were taken before each beam was delivered to verify imaging/radiation isocentricity. Results: Verity suggested couch corrections and known CT shifts/rotations agreed within ±1mm (average: Δ lat=0.5mm; Δ vert=0.4mm; Δ long=0.3mm) and ± 0.4° (average: Δ pitch=0.24° Δ roll=0.01°; Δ yaw=0.10°). Physical couch measurements and Verity applied corrections agreed within ± 1mm (average: Δlat=0.5mm; Δvert=0.4mm; Δlong=0.2mm) and ±0.2° (average: Δpitch=0.03°; Δ roll=0.04°; Δ yaw=0.04°). The directionality of all translations and rotations were qualitatively verified. The image vs. radiation isocenter coincidence was <1mm and radiation-isocenter precision was <1mm over the 180° of couch motion, as indicated by film analysis. Conclusion: The Verity IGRT software and 6D-couch combination on the Mevion S250 was verified as accurate within 1mm and 0.5°. This complies with the TG-142 standards for a stereotactic radiotherapy IGRT system. Rob Cessac is employed as Product Manager for Mevion Medical Systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-45: The Correlation Between CBCT Flat Panel Misalignment and 3D Image Guidance Accuracy

Purpose To simulate the impact of CBCT flat panel misalignment on the image quality, the calculated correction vectors in 3D image guided proton therapy and to determine if these calibration errors can be caught in our QA process. Methods The X-ray source and detector geometrical calibration (flexmap) file of the CBCT system in the AdaPTinsight software (IBA proton therapy) was edited to induce known changes in the rotational and translational calibrations of the imaging panel. Translations of up to ±10 mm in the x, y and z directions (see supplemental) and rotational errors of up to ±3° were induced. The calibration files were then used to reconstruct the CBCT image of a pancreatic patient and CatPhan phantom. Correction vectors were calculated for the patient using the software’s auto match system and compared to baseline values. The CatPhan CBCT images were used for quantitative evaluation of image quality for each type of induced error. Results Translations of 1 to 3 mm in the x and y calibration resulted in corresponding correction vector errors of equal magnitude. Similar 10mm shifts were seen in the y-direction; however, in the x-direction, the image quality was too degraded for a match. These translational errors can be identified through differences in isocenter from orthogonal kV images taken during routine QA. Errors in the z-direction had no effect on the correction vector and image quality.Rotations of the imaging panel calibration resulted in corresponding correction vector rotations of the patient images. These rotations also resulted in degraded image quality which can be identified through quantitative image quality metrics. Conclusion Misalignment of CBCT geometry can lead to incorrect translational and rotational patient correction vectors. These errors can be identified through QA of the imaging isocenter as compared to orthogonal images combined with monitoring of CBCT image quality.

60 APPLIED LIFE SCIENCES↗

TU-EF-210-00: Therapeutic Strategies and Image Guidance

The use of therapeutic ultrasound to provide targeted therapy is an active research area that has a broad application scope. The invited talks in this session will address currently implemented strategies and protocols for both hyperthermia and ablation applications using therapeutic ultrasound. The role of both ultrasound and MRI in the monitoring and assessment of these therapies will be explored in both pre-clinical and clinical applications. Katherine Ferrara: High Intensity Focused Ultrasound, Drug Delivery, and Immunotherapy Rajiv Chopra: Translating Localized Doxorubicin Delivery to Pediatric Oncology using MRI-guided HIFU Elisa Konofagou: Real-time Ablation Monitoring and Lesion Quantification using Harmonic Motion Imaging Keyvan Farahani: AAPM Task Groups in Interventional Ultrasound Imaging and Therapy Learning Objectives: Understand the role of ultrasound in localized drug delivery and the effects of immunotherapy when used in conjunction with ultrasound therapy. Understand potential targeted drug delivery clinical applications including pediatric oncology. Understand the technical requirements for performing targeted drug delivery. Understand how radiation-force approaches can be used to both monitor and assess high intensity focused ultrasound ablation therapy. Understand the role of AAPM task groups in ultrasound imaging and therapies. Chopra: Funding from Cancer Prevention and Research Initiative of Texas (CPRIT), Award R1308 Evelyn and M.R. Hudson Foundation; Research Support from Research Contract with Philips Healthcare; COI are Co-founder of FUS Instruments Inc Ferrara: Supported by NIH, UCDavis and California (CIRM and BHCE) Farahani: In-kind research support from Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

WE-EF-207-01: FEATURED PRESENTATION and BEST IN PHYSICS (IMAGING): Task-Driven Imaging for Cone-Beam CT in Interventional Guidance

Purpose: This work introduces a task-driven imaging framework that utilizes a patient-specific anatomical model, mathematical definition of the imaging task, and a model of the imaging system to prospectively design acquisition and reconstruction techniques that maximize task-based imaging performance. Utility of the framework is demonstrated in the joint optimization of tube current modulation and view-dependent reconstruction kernel in filtered-backprojection reconstruction and non-circular orbit design in model-based reconstruction. Methods: The system model is based on a cascaded systems analysis of cone-beam CT capable of predicting the spatially varying noise and resolution characteristics as a function of the anatomical model and a wide range of imaging parameters. Detectability index for a non-prewhitening observer model is used as the objective function in a task-driven optimization. The combination of tube current and reconstruction kernel modulation profiles were identified through an alternating optimization algorithm where tube current was updated analytically followed by a gradient-based optimization of reconstruction kernel. The non-circular orbit is first parameterized as a linear combination of bases functions and the coefficients were then optimized using an evolutionary algorithm. The task-driven strategy was compared with conventional acquisitions without modulation, using automatic exposure control, and in a circular orbit. Results: The task-driven strategy outperformed conventional techniques in all tasks investigated, improving the detectability of a spherical lesion detection task by an average of 50% in the interior of a pelvis phantom. The non-circular orbit design successfully mitigated photon starvation effects arising from a dense embolization coil in a head phantom, improving the conspicuity of an intracranial hemorrhage proximal to the coil. Conclusion: The task-driven imaging framework leverages a knowledge of the imaging task within a patient-specific anatomical model to optimize image acquisition and reconstruction techniques, thereby improving imaging performance beyond that achievable with conventional approaches. 2R01-CA-112163; R01-EB-017226; U01-EB-018758; Siemens Healthcare (Forcheim, Germany)

60 APPLIED LIFE SCIENCES↗

SU-F-J-18: Feasibility of Open Mask Immobilization with Optical Imaging Guidance (OIG) for H&N Radiotherapy

Purpose: Full face and neck thermoplastic masks provide standard-of-care immobilization for patients receiving H&N IMRT. However, these masks are uncomfortable and increase skin dose. The purpose of this pilot study was to investigate the feasibility and setup accuracy of open face and neck mask immobilization with OIG. Methods: Ten patients were consented and enrolled to this IRB-approved protocol. Patients were immobilized with open masks securing only forehead and chin. Standard IMRT to 60–70 Gy in 30 fractions were delivered in all cases. Patient simulation information, including isocenter location and CT skin contours, were imported to a commercial OIG system. On the first day of treatment, patients were initially set up to surface markings and then OIG referenced to face and neck skin regions of interest (ROI) localized on simulation CT images, followed by in-room CBCT. CBCTs were acquired at least weekly while planar OBI was acquired on the days without CBCT. Following 6D robotic couch correction with kV imaging, a new optical real-time surface image was acquired to track intrafraction motion and to serve as a reference surface for setup at the next treatment fraction. Therapists manually recorded total treatment time as well as couch shifts based on kV imaging. Intrafractional ROI motion tracking was automatically recorded. Results: Setup accuracy of OIG was compared with CBCT results. The setup error based on OIG was represented as a 6D shift (vertical/longitudinal/lateral/rotation/pitch/roll). Mean error values were −0.70±3.04mm, −0.69±2.77mm, 0.33±2.67 mm, −0.14±0.94 o, −0.15±1.10o and 0.12±0.82o, respectively for the cohort. Average treatment time was 24.1±9.2 minutes, comparable to standard immobilization. The amplitude of intrafractional ROI motion was 0.69±0.36 mm, driven primarily by respiratory neck motion. Conclusion: OGI can potentially provide accurate setup and treatment tracking for open face and neck immobilization. Study accrual and patient/provider satisfaction survey collection remain ongoing. This study is supported by VisionRT, Ltd.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRC-02: Low-Z Switching Linear Accelerator Targets: New Options for Image Guidance and Dose Enhancement in Radiotherapy

Experimental research in medical physics has expanded the limits of our knowledge and provided novel imaging and therapy technologies for patients around the world. However, experimental efforts are challenging due to constraints in funding, space, time and other forms of institutional support. In this joint ESTRO-AAPM symposium, four exciting experimental projects from four different countries are highlighted. Each project is focused on a different aspect of radiation therapy. From the USA, we will hear about a new linear accelerator concept for more compact and efficient therapy devices. From Canada, we will learn about novel linear accelerator target design and the implications for imaging and therapy. From France, we will discover a mature translational effort to incorporate theranostic nanoparticles in MR-guided radiation therapy. From Germany, we will find out about a novel in-treatment imaging modality for particle therapy. These examples of high impact, experimental medical physics research are representative of the diversity of such efforts that are on-going around the globe. J. Robar, Research is supported through collaboration with Varian Medical Systems and Brainlab AGD. Westerly, This work is supported by the Department of Radiation Oncology at the University of Colorado School of Medicine. COI: NONEK. Parodi, Part of the presented work is supported by the DFG (German Research Foundation) Cluster of Excellence MAP (Munich-Centre for Advanced Photonics) and has been carried out in collaboration with IBA.

60 APPLIED LIFE SCIENCES↗