Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Lateral Heterogeneous Integration of Quantum Cascade Lasers

Broadband terahertz radiation potentially has extensive applications, ranging from personal health care to industrial quality control and security screening. While traditional methods for broadband terahertz generation rely on bulky and expensive mode-locked lasers, frequency combs based on quantum cascade lasers (QCLs) can provide an alternative compact, high power, wideband terahertz source. QCL frequency combs incorporating a heterogeneous gain medium design can obtain even greater spectral range by having multiple lasing transitions at different frequencies. However, despite their greater spectral coverage, the comparatively low gain from such gain media lowers the maximum operating temperature and power. Lateral heterogeneous integration offers the ability to cover an extensive spectral range while maintaining the competitive performance offered from each homogeneous gain media. In this paper, we present the first lateral heterogeneous design for broadband terahertz generation: by combining two different homogeneous gain media, we have achieved a two-color frequency comb spaced by 1.5 THz.

47 OTHER INSTRUMENTATION↗

Colloidal quantum dot lasers

We report semiconductor nanocrystals represent a promising class of solution-processable optical-gain media that can be manipulated via inexpensive, easily scalable colloidal techniques. Due to their extremely small sizes (typically <10 nm), their properties can be directly controlled via effects of quantum confinement; therefore, they are often termed colloidal quantum dots (CQDs). In addition to size-tunable emission wavelengths, CQDs offer other benefits for lasing applications, including low optical-gain thresholds and high temperature stability of lasing characteristics. Recent progress in understanding and practical control of processes impeding light amplification in CQDs has resulted in several breakthroughs, including the demonstration of optically pumped continuous-wave lasing, the realization of optical gain with direct current electrical injection and the development of dual-function electroluminescent devices that also operate as optically pumped lasers. The purpose of this Review is to assess the status of the field of CQD lasing and discuss the existing challenges and opportunities. A particular focus is on approaches for suppressing nonradiative Auger recombination, novel optical-gain concepts enabled by strong exciton-exciton interactions and controlled CQD charging, effects of nanocrystal form factors on light amplification and practical architectures for realizing electrically pumped CQD lasers. This overview suggests that the accumulated knowledge, along with the approaches developed for manipulating the optical-gain properties of colloidal nanostructures, perfectly position the CQD field for successfully addressing a long-standing challenge: the realization of CQD-based laser diodes. Colloidal quantum dots are promising materials for realizing versatile, wavelength-tunable, solution-processed lasers. This Review surveys recent advances in colloidal quantum dot lasing, provides an in-depth analysis of outstanding challenges and discusses a path forward to implementing technologically viable lasing devices.

36 MATERIALS SCIENCE↗

Advances in x-ray framing cameras at the National Ignition Facility to improve quantitative precision in x-ray imaging

We describe an experimental method to measure the gate profile of an x-ray framing camera and to determine several important functional parameters: relative gain (between strips), relative gain droop (within each strip), gate propagation velocity, gate width, and actual inter-strip timing. Several of these parameters cannot be measured accurately by any other technique. This method is then used to document cross talk-induced gain variations and artifacts created by radiation that arrives before the framing camera is actively amplifying x-rays. Electromagnetic cross talk can cause relative gains to vary significantly as inter-strip timing is varied. This imposes a stringent requirement for gain calibration. If radiation arrives before a framing camera is triggered, it can cause an artifact that manifests as a high-intensity, spatially varying background signal. Furthermore, we have developed a device that can be added to the framing camera head to prevent these artifacts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Type-II vertical-external-cavity surface-emitting laser with Watt level output powers at 1.2 μ m

Semiconductor laser characteristics based on type-II band-aligned quantum well heterostructures for the emission at 1.2 μm are presented. Ten “W”-quantum wells consisting of GaAs/(GaIn)As/Ga(AsSb)/(GaIn)As/GaAs are arranged as resonant periodic gain in a vertical-external-cavity surface-emitting laser. Its structure is analyzed by X-ray diffraction, photoluminescence, and reflectance measurements. The laser's power curves and spectra are investigated. Output powers at Watt level are achieved, with a maximum output power of 4 W. It is confirmed that laser operation only involves the type-II transition. A blue shift of the material gain is observed while the modal gain exhibits a red shift.

Möller, C.↗

Optimization and application of cooled avalanche photodiodes for spectroscopic fluctuation measurements with ultra-fast charge exchange recombination spectroscopy

The Ultra Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic is a highly specialized spectroscopic instrument with 2 spatial channels consisting of 8 spectral channels each and a resolution of ~0.25 nm deployed at DIII-D to measure turbulent ion temperature fluctuations. Charge exchange emissions are obtained between 528-530 nm with 1 μs time resolution to study plasma instabilities. A primary challenge of extracting fluctuation measurements from raw UF-CHERS signals is photon and electronic noise. In order to reduce dark current, the Avalanche Photodiode (APD) detectors are thermoelectrically cooled. State-of-the-art components are used for the signal amplifiers and conditioners to minimize electronic noise. Due to the low incident photon power (≤ 1 nW), APDs with a gain of up to 300 are used to optimize the signal to noise ratio. Maximizing the APDs’ gain while minimizing the excess noise factor (ENF) is essential since the total noise of the diagnostic sets a floor for the minimum level of detectable broadband fluctuations. The APDs’ gain should be high enough that photon noise dominates electronic noise, but not excessive so that the ENF overwhelms plasma fluctuations. A new generation of cooled APDs and optimized preamplifiers exhibits significantly enhanced signal-to-noise compared to a previous generation. Experiments at DIII-D have allowed for characterization and optimization of the ENF vs. gain. Here, a gain of ~100 at 1700 V is found to be near optimal for most plasma conditions. Ion temperature and toroidal velocity fluctuations due to the Edge Harmonic Oscillation (EHO) in Quiescent H-mode (QH) plasmas are presented to demonstrate UF-CHERS’ capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the potential for wake steering for U.S. land-based wind power plants

The wind power plant-wide control strategy known as wake steering involves the misalignment of upstream turbines with the wind direction to deflect wakes away from downstream turbines, increasing net wind plant power production. In this paper, we evaluate the potential of wake steering for U.S. land-based wind power plants. First, we outline a method for simulating and optimizing wake steering control for existing wind plants by combining the flow redirection and induction in steady state wake steering engineering model with the U.S. Wind Turbine Database and Wind Integration National Dataset Toolkit wind resource dataset. Next, to better understand the potential benefits of wake steering beyond those for existing wind plants, we evaluate the relative impacts of turbine specific power, turbine spacing, and mean wind speed on energy gain and levelized cost of energy (LCOE) using a model land-based wind power plant. For a subset of 60 existing wind plants, assuming a constant turbulence intensity of 8%, wake steering was found to yield an average annual energy production (AEP) gain of 0.80%, equivalent to recovering 13.85% of baseline wake losses. Further, we present a linear approximation between baseline wake losses and AEP gains that can be used to estimate wake steering gains for other wind power plants. Highlighting additional benefits of wake steering, for the model wind power plant we found that energy gains from wake steering enabled an approximate 30% reduction in turbine spacing while keeping LCOE constant.

17 WIND ENERGY↗

The force explosion condition is consistent with spherically symmetric CCSN explosions

ABSTRACT One of the major challenges in core-collapse supernova (CCSN) theory is to predict which stars explode and which collapse to black holes. The analytic force explosion condition (FEC) shows promise in predicting which stars explode in that the FEC is consistent with CCSN simulations that use the light-bulb approximation for neutrino heating and cooling. In this follow-up manuscript, we take the next step and show that the FEC is consistent with the explosion condition when using actual neutrino transport in gr1d simulations. Since most 1D simulations do not explode, to facilitate this test, we enhance the heating efficiency within the gain region. To compare the analytic FEC and radiation-hydrodynamic simulations, this manuscript also presents a practical translation of the physical parameters. For example: we replace the neutrino power deposited in the gain region, Lντg, with the net neutrino heating in the gain region; rather than assuming that $\dot{M}$ is the same everywhere, we calculate $\dot{M}$ within the gain region; and we use the neutrino opacity at the gain radius. With small, yet practical modifications, we show that the FEC predicts the explosion conditions in spherically symmetric CCSN simulations that use neutrino transport.

79 ASTRONOMY AND ASTROPHYSICS↗

Propagation of quasisolitons in a fiber Bragg grating written in a slow saturable fiber amplifier

We show, by using numerical simulations, that quasisolitons can propagate over a long distance in a fiber Bragg grating that is written in a slow saturable fiber amplifier, such as an erbium-doped fiber amplifier. During the pulse propagation, the front end of the pulse experiences a net gain while the rear end of pulse is attenuated due to the combination of gain saturation and loss. However, the pulse profile almost does not change after propagating over a length of 5 m that is approximately 2500 times larger than the spatial pulse width. The pulse amplitude has an approximately hyperbolic secant profile. We develop a reduced model by using a multiscale analysis to study solitary-wave propagation when nonlinearity and gain are small. When gain saturation also becomes small we find analytically a new family of solitary-wave hyperbolic-secant solutions that approximately solve the reduced model. The solitary waves propagate slightly faster than Bragg solitons that propagate in fiber Bragg gratings without gain and loss.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dark Energy Survey Year 3 results: Optimizing the lens sample in a combined galaxy clustering and galaxy-galaxy lensing analysis

We investigate potential gains in cosmological constraints from the combination of galaxy clustering and galaxy-galaxy lensing by optimizing the lens galaxy sample selection using information from Dark Energy Survey (DES) Year 3 data and assuming the DES Year 1 metacalibration sample for the sources. We explore easily reproducible selections based on magnitude cuts in i-band as a function of (photometric) redshift, zphot, and benchmark the potential gains against those using the well-established redMaGiC [E. Rozo et al., Mon. Not. R. Astron. Soc. 461, 1431 (2016)MNRAA40035-871110.1093/mnras/stw1281] sample. We focus on the balance between density and photometric redshift accuracy, while marginalizing over a realistic set of cosmological and systematic parameters. Our optimal selection, the MagLim sample, satisfies i<4zphot+18 and has ∼30% wider redshift distributions but ∼3.5 times more galaxies than redMaGiC. Assuming a wCDM model (i.e. with a free parameter for the dark energy equation of state) and equivalent scale cuts to mitigate nonlinear effects, this leads to 40% increase in the figure of merit for the pair combinations of Ωm, w, and σ8, and gains of 16% in σ8, 10% in Ωm, and 12% in w. Similarly, in ΛCDM, we find an improvement of 19% and 27% on σ8 and Ωm, respectively. We also explore flux-limited samples with a flat magnitude cut finding that the optimal selection, i<22.2, has ∼7 times more galaxies and ∼20% wider redshift distributions compared to MagLim, but slightly worse constraints. We show that our results are robust with respect to the assumed galaxy bias and photometric redshift uncertainties with only moderate further gains from increased number of tomographic bins or the inclusion of bin cross-correlations, except in the case of the flux-limited sample, for which these gains are more significant.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-Axis Tracker Control Optimization Potential for the Contiguous United States

Conventional tracker control algorithms maximize collection of direct irradiance with no regard for collection of diffuse irradiance. Therefore, a tracker control algorithm that optimizes for maximal total irradiance, not just direct, might realize improved insolation collection. Using weather data gridded at 0.25° by 0.25° latitude/longitude spacing covering the contiguous United States, we evaluate the insolation gain of two alternative control algorithms optimized for improved total irradiance collection in monofacial arrays and present annual and monthly geographic heatmaps showing the gains across the contiguous United States. Certain locations show potential annual insolation gains approaching 1.0%, but most locations with recently-built tracker systems show annual gains between 0.1% and 0.4%. We also demonstrate a relationship between a climate's annualized diffuse insolation fraction and its potential tracker optimization insolation gain.

diffuse↗

Small-Signal Modeling and Design of Phase-Locked Loops Using Harmonic Signal-Flow Graphs

This report introduces signal-flow graphs for linear time-periodic systems to streamline and visually describe the frequency-domain modeling of complex phase-locked loop (PLL) systems used in grid-connected converters. Small-signal modeling using the proposed graphs is demonstrated for two commonly used single-phase PLL structures: SOGI-PLL and Park-PLL. Loop-gain models are developed for these PLLs to evaluate how an orthogonal signal generator (OSG), which is required in single-phase PLLs using the synchronous reference frame (SRF) architecture, modifies the PLL loop-gain compared to that of a three-phase SRF-PLL, which does not require an OSG. It is shown that the OSG in the SOGI-PLL and Park-PLL introduces significant phase-lag in the PLL loop-gain, limiting the maximum bandwidth for which either PLL can be designed. Slow frequency adaptation (SFA) of OSG is proposed as a solution to mitigate the influence of the OSG dynamics on the PLL loop-gain. Experimental results are presented to validate the developed loop-gain models and show that the proposed SFA-SOGI-PLL and SFA-Park-PLL have improved transient performance, they do not suffer from the bandwidth limit, and they also preserve the steady-state performance of the standard SOGI-PLL and Park-PLL.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spike-Free Adaptive Sliding Mode Control: Application to Permanent Magnet Synchronous Motors

A new methodology for adaptive sliding mode control (ASMC) has been widely used to improve the control performance in various systems. This method exhibits several advantages, including low sliding mode control (SMC) chattering, no knowledge of the system disturbance bound, and no overestimation of the control gain. Despite its advantages, this method can be hampered by the spike phenomenon, slow control gain convergence, and difficulty in achieving optimal performance under varying disturbances. Consequently, this article proposes a spike-free ASMC method with a disturbance observer (DOB) to address these problems. Previous ASMC methods have been analyzed via simulations to verify the aforementioned problems. Here, this analysis highlights the need for disturbance compensation and improvements in the SMC gain adaptation law. Therefore, a DOB is designed to mitigate the spike phenomenon by compensating for disturbances. Subsequently, an SMC gain adaptation law based on disturbance error estimation is designed to eliminate the spike phenomenon completely. The proposed adaptation law makes the SMC gain to converge to a slightly higher value than the disturbance estimation error. Consequently, the proposed method not only eliminates the spike phenomenon, but also ensures optimal performance under varying disturbances. The performance of the proposed method is experimen tally validated through a comparative study.

42 ENGINEERING↗

Noise variance analysis using a flat panel x-ray detector: A method for additive noise assessment with application to breast CT applications

Purpose: A simplified linear model approach was proposed to accurately model the response of a flat panel detector used for breast CT (bCT). Methods: Individual detector pixel mean and variance were measured from bCT projection images acquired both in air and with a polyethylene cylinder, with the detector operating in both fixed low gain and dynamic gain mode. Once the coefficients of the linear model are determined, the fractional additive noise can be used as a quantitative metric to evaluate the system's efficiency in utilizing x-ray photons, including the performance of different gain modes of the detector. Results: Fractional additive noise increases as the object thickness increases or as the radiation dose to the detector decreases. For bCT scan techniques on the UC Davis prototype scanner (80 kVp, 500 views total, 30 frames/s), in the low gain mode, additive noise contributes 21% of the total pixel noise variance for a 10 cm object and 44% for a 17 cm object. With the dynamic gain mode, additive noise only represents approximately 2.6% of the total pixel noise variance for a 10 cm object and 7.3% for a 17 cm object. Conclusions: The existence of the signal-independent additive noise is the primary cause for a quadratic relationship between bCT noise variance and the inverse of radiation dose at the detector. With the knowledge of the additive noise contribution to experimentally acquired images, system modifications can be made to reduce the impact of additive noise and improve the quantum noise efficiency of the bCT system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-G-18A-02: Calibration-Free Combined KV/MV Short Scan CBCT

Purpose: To combine orthogonal kilo-voltage (kV) and Mega-voltage (MV) projection data for short scan cone-beam CT to reduce imaging time on current radiation treatment systems, using a calibration-free gain correction method. Methods: Combining two orthogonal projection data sets for kV and MV imaging hardware can reduce the scan angle to as small as 110° (90°+fan) such that the total scan time is ∼18 seconds, or within a breath hold. To obtain an accurate reconstruction, the MV projection data is first linearly corrected using linear regression using the redundant data from the start and end of the sinogram, and then the combined data is reconstructed using the FDK method. To correct for the different changes of attenuation coefficients in kV/MV between soft tissue and bone, the forward projection of the segmented bone and soft tissue from the first reconstruction in the redundant region are added to the linear regression model. The MV data is corrected again using the additional information from the segmented image, and combined with kV for a second FDK reconstruction. We simulated polychromatic 120 kVp (conventional a-Si EPID with CsI) and 2.5 MVp (prototype high-DQE MV detector) projection data with Poisson noise using the XCAT phantom. The gain correction and combined kV/MV short scan reconstructions were tested with head and thorax cases, and simple contrast-to-noise ratio measurements were made in a low-contrast pattern in the head. Results: The FDK reconstruction using the proposed gain correction method can effectively reduce artifacts caused by the differences of attenuation coefficients in the kV/MV data. The CNRs of the short scans for kV, MV, and kV/MV are 5.0, 2.6 and 3.4 respectively. The proposed gain correction method also works with truncated projections. Conclusion: A novel gain correction and reconstruction method was developed to generate short scan CBCT from orthogonal kV/MV projections. This work is supported by NIH Grant 5R01CA138426-05.

60 APPLIED LIFE SCIENCES↗

SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing

Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability and accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-03: A CBCT Head Scanner for Point-Of-Care Imaging of Intracranial Hemorrhage

Purpose: This work reports the design, development, and first technical assessment of a cone-beam CT (CBCT) scanner developed specifically for imaging of acute intracranial hemorrhage (ICH) at the point of care, with target applications in diagnosis and monitoring of traumatic brain injury, stroke, and postsurgical hemorrhage. Methods: System design employed a task-based image quality model to quantify the influence of factors such as additive noise and high-gain (HG) detector readout on ICH detectability. Three bowtie filters with varying bare-beam attenuation strength and curvature were designed to enable HG readout without detector saturation, and a polyenergetic gain correction was developed to minimize artifacts from bowtie flood-field calibration. Image reconstruction used an iterative penalized weighted least squares (PWLS) method with artifact correction including Monte Carlo scatter estimation, Joseph-Spital beam hardening correction, and spatiotemporal deconvolution of detector glare and lag. Radiation dose was characterized for half-scan and full-scan protocols at various kV, and imaging performance was assessed in a head phantom presenting simulated ICH with diameter ranging 2–12 mm. Results: The image quality model guided system design and was validated by measurements on a CBCT imaging bench. Compared to low-gain readout without a bowtie filter, the combination of HG readout and a modest bowtie improved the contrast-to-noise ratio (CNR per unit square-root dose) by 20% in the center of the image but degraded noise performance near the periphery (20% reduction in CNR). Low-frequency bowtie artifacts (∼100 HU magnitude) were corrected by the polyenergetic gain correction. Image reconstructions on the prototype scanner demonstrate clear visibility of the smallest ICH insert (2 mm diameter) in both HG readout (with a bowtie) and dual-gain readout (without bowtie). Conclusion: Technical assessment of the prototype scanner suggests the capability for reliable visualization of small (2 mm), low-contrast (50 HU) ICH at <20 mGy dose and motivates translation to clinical studies, now underway. Xiaohui Wang and David Foos (co-authors) are employees of Carestream Health. Research funding support from Carestream Health.

60 APPLIED LIFE SCIENCES↗