Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Thermal control for the 1990's

Current thermal distribution systems on large spacecraft, such as the Space Shuttle and Spacelab, use pumped fluid loops that circulate the coolant between a series of user stations and a single rejection point, involving complex plumbing and controls with a significant power penalty and limited reliability. In order to provide heat transport at near-isothermal conditions in future large spacecraft, two-phase flow systems will be implemented by taking advantage of the heat of vaporization and condensation of common working fluids at minimal expenditure of power and temperature variation. Such systems are considered for the cases of the thermal requirements of nearly 100 potential astrophysics and astronomy instruments. Data on temperature requirements, power dissipations, environmental fluxes, heat addition or rejection, and general description, are used to form conceptual designs for the thermal utility.

Ollendorf, S.↗

Optical spectrophotometry of the Cygnus Loop

Cygnus Loop filament optical spectral properties are discussed, with emphasis on comparisons between observational and model data. Some line intensities are correlated among filaments in such a way as to suggest that a well resolved ionization structure behind the shock front is being observed. Departures from the steady flow condition assumed in the present model are found to be necessary in order to improve agreement with observations.

Fesen, R. A.↗

3-D components of a biological neural network visualized in computer generated imagery. II - Macular neural network organization

Computer-assisted reconstructions of small parts of the macular neural network show how the nerve terminals and receptive fields are organized in 3-dimensional space. This biological neural network is anatomically organized for parallel distributed processing of information. Processing appears to be more complex than in computer-based neural network, because spatiotemporal factors figure into synaptic weighting. Serial reconstruction data show anatomical arrangements which suggest that (1) assemblies of cells analyze and distribute information with inbuilt redundancy, to improve reliability; (2) feedforward/feedback loops provide the capacity for presynaptic modulation of output during processing; (3) constrained randomness in connectivities contributes to adaptability; and (4) local variations in network complexity permit differing analyses of incoming signals to take place simultaneously. The last inference suggests that there may be segregation of information flow to central stations subserving particular functions.

Ross, Muriel D.↗

Two-dimensional simulation of a two-phase, regenerative pumped radiator loop utilizing direct contact heat transfer with phase change

An innovative pumped loop concept for 600 K space power system radiators utilizing direct contact heat transfer, which facilitates repeated startup/shutdown of the power system without complex and time-consuming coolant thawing during power startup, is under development. The heat transfer process with melting/freezing of Li in an NaK flow was studied through two-dimensional time-dependent numerical simulations to characterize and predict the Li/NaK radiator performance during startup (thawing) and shutdown (cold-trapping). Effects of system parameters and the criteria for the plugging domain are presented together with temperature distribution patterns in solid Li and subsequent melting surface profile variations in time.

Rhee, Hyop S.↗

Post-flare loops embedded in a hot coronal fan-like structure

Limb events were demonstrated on the sun in which rising post-flare loops were embedded in hot structures looking in soft X-rays like fans of rays, formed during the flare and extending high into the corona. One of these structures is analyzed and it is suggested that these fans of rays represent temporary ministreamers, along which mass flows into interplanetary space. This suggestion is supported by maps of solar wind density constructed from scintillation measurements.

Svestka, Z.↗

Choked-Flow Inlet Orifice Bubbler for Creating Small Bubbles in Mercury

Pressure waves created in liquid mercury pulsed spallation targets like the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, induce cavitation damage on the target container. The cavitation damage is thought to limit the lifetime of the target for power levels at and above 1 MW. One way to mitigate the damage would be to absorb the pressure pulse energy into a dispersed population of small bubbles, however, creating a bubble size distribution that is sufficiently large and disperse in mercury is challenging due to the high surface tension. Also, measuring the population is complicated by the opacity and the high level of turbulent mixing. Recent advances in bubble diagnostics by batch sampling the mercury made it possible to compare bubble populations for different techniques in a SNS-1/20th scale test loop. More than 10 bubblers were tested and the most productive bubblers were taken for in-beam testing at the Los Alamos Neutron Science Center (LANSCE) WNR user facility. One bubbler design, referred to as the inlet-orifice bubbler, that showed moderate success in creating populations also has an added advantage that it could easily be included in the existing SNS full-scale mercury target configuration. Improvements to the bubbler were planned including a reduction of the nozzle size to choke the gas injection, thus steadying the injected mass flow and allowing multiple nozzles to work off of a common plenum. For the first time, reliable bubble population data are available in the prototypical target geometry and can be compared with populations that mitigated cavitation damage. This paper presents those experimental results.

mercury bubbles SNS cavitation damage mitigation e↗

Deconvoluting sources of variability in aerosol jet printing using light scattering measurements

Aerosol jet printing (AJP) is a digital additive manufacturing technique for hybrid and conformal electronics, where its contactless deposition readily enables patterning over 3D surface topography. However, the complexity of aerosol transport physics makes deposition rate sensitive to process variability, hindering widespread industry adoption. Light scattering measurements have recently been demonstrated as a capable tool for measuring deposition rate in real time, enabling closed-loop control and in-situ qualification frameworks. These inline optical measurements present further opportunity as a diagnostic tool to understand the effects of secondary process parameters affecting vapor–liquid equilibrium and heat and mass transport during deposition. Downstream of the optical measurement cell, changing the sheath gas flow rate, increasing temperature via an inline heater, and adding solvent vapor via a sheath gas bubbler were observed to alter drying physics during sheath-collimation, and thereby impaction efficiency. Further upstream, the introduction of solvent vapor via a carrier gas bubbler and liquid build-up in the printhead were seen to affect the quantitative relationship between the light scattering data and the true deposition rate. Using this information, tightened controls of meaningful secondary parameters were implemented to improve the batch-to-batch consistency for printing a dielectric ink. In addition to advancing AJP process reliability for production, this work demonstrates the capability of inline optical measurements to provide insight into process physics and deconvolute competing mechanisms that underly variability.

additive manufacturing↗

Development of a Method for Shape Optimization for a Gas Turbine Fuel Injector Design Using Metal-Additive Manufacturing

Adjoint shape optimization has enabled physics-based optimal designs for aerodynamic surfaces. Additive manufacturing (AM) makes it possible to manufacture complex shapes. However, there has been a gap between optimal and manufacturable surfaces due to the inherent limitations of commercial computational fluid dynamics (CFD) codes to implement geometric constraints during adjoint computation. In such cases, the design sensitivities are exported and used to perform constrained shape modifications using parametric information stored in computer aided design (CAD) files to satisfy manufacturability constraints. However, modifying the design using adjoint methods in CFD solvers and performing constrained shape modification in CAD can lead to inconsistencies due to different shape parameterization schemes. This paper describes a method to enable the simultaneous optimization of the fluid domain and impose AM manufacturability constraints, resolving one of the key issues of geometry definition for isogeometric analysis. Similar to a grid convergence study, the proposed method verifies the consistencies between shape parameterization techniques present within commercial CAD and CFD software during mesh movement as a part of the adjoint shape optimization routine. By identifying the appropriate parameters essential to a shape optimization study, the error metric between the different parameterization techniques converges to demonstrate sufficient consistencies for justifiable exchange of data between CAD and CFD. For the identified shape optimization parameters, the error metric to measure the deviation between the two parameterization schemes lies within the AM laser-powder bed fusion (L-PBF) process tolerance. Additionally, comparison for subsequent objective function calculations between iterations of the optimization loop showed acceptable differences within 1% variation between the modified geometries obtained using the two parameterization schemes. This method provides justification for the use of multiphysics guided adjoint design sensitivities computed in CFD software to perform shape modifications in CAD to incorporate AM manufacturability constraints during the shape optimization loop such that optimal designs are also additively manufacturable.

33 ADVANCED PROPULSION SYSTEMS↗

Continuous cardiac output measurement - Aspects of Doppler frequency analysis

From the suprasternal notch blood flow velocity in the aorta can be measured non-invasively by a Doppler probe. Integration over systole after frequency analysis gives a measure of stroke volume if a separate diameter observation is incorporated. Frequency analysis by a zero crossing counter or by a set of parallel phaselock loops was less effective than a set of bandpass filters. Observations on dogs, baboons and humans before and after exercise or surgery suggest the indications to be useful. Application to judging heart failure by the effect of introducing a volume load is indicated. Changes in output also are measured in freely moving subjects.

Mackay, R. S.↗

Investigation of the effects of external current systems on the MAGSAT data utilizing grid cell modeling techniques

The feasibility of modeling magnetic fields due to certain electrical currents flowing in the Earth's ionosphere and magnetosphere was investigated. A method was devised to carry out forward modeling of the magnetic perturbations that arise from space currents. The procedure utilizes a linear current element representation of the distributed electrical currents. The finite thickness elements are combined into loops which are in turn combined into cells having their base in the ionosphere. In addition to the extensive field modeling, additional software was developed for the reduction and analysis of the MAGSAT data in terms of the external current effects. Direct comparisons between the models and the MAGSAT data are possible.

Klumpar, D. M.↗

A survey of unified constitutive theories

The state of the art of time temperature dependent elastic viscoplastic constitutive theories which are based on the unified approach werre assessed. This class of constitutive theories is characterized by the use of kinetic equations and internal variables with appropriate evolutionary equations for treating all aspects of inelastic deformation including plasticity, creep, and stress relaxation. More than 10 such unified theories which are shown to satisfy the uniqueness and stability criteria imposed by Drucker's postulate and Ponter's inequalities are identified. The theories are compared for the types of flow law, kinetic equation, evolutionary equation of the internal variables, and treatment of temperature dependence. The similarities and differences of these theories are outlined in terms of mathematical formulations and illustrated by comparisons of theoretical calculations with experimental results which include monotonic stress-strain curves, cyclic hysteresis loops, creep and stress relaxation rates, and thermomechanical loops. Numerical methods used for integrating these stiff time temperature dependent constitutive equations are reviewed.

Chan, K. S.↗

Study of ice accretion on icing wind tunnel components

In a closed loop icing wind tunnel the icing cloud is simulated by introducing tiny water droplets through an array of nozzles upstream of the test section. This cloud will form ice on all tunnel components (e.g., turning vanes, inlet guide vanes, fan blades, and the heat exchanger) as the cloud flows around the tunnel. These components must have the capacity to handle their icing loads without causing significant tunnel performance degradation during the course of an evening's run. To aid in the design of these components for the proposed Altitude Wind Tunnel (AWT) at NASA Lewis Research Center the existing Icing Research Tunnel (IRT) is used to measure icing characteristics of the IRT's components. The results from the IRT are scaled to the AWT to account for the AWT's larger components and higher velocities. The results show that from 90 to 45 percent of the total spray cloud froze out on the heat exchanger. Furthermore, the first set of turning vanes downstream of the test section, the FOD screen and the fan blades show significant ice formation. The scaling shows that the same results would occur in the AWT.

Newton, J. E.↗

Study of ice accretion on icing wind tunnel components

In a closed loop icing wind tunnel the icing cloud is simulated by introducing tiny water droplets through an array of nozzles upstream of the test section. This cloud will form ice on all tunnel components (e.g., turning vanes, inlet guide vanes, fan blades, and the heat exchanger) as the cloud flows around the tunnel. These components must have the capacity to handle their icing loads without causing significant tunnel performance degradation during the course of an evening's run. To aid in the design of these components for the proposed Altitude Wind Tunnel (AWT) at NASA Lewis Research Center the existing Icing Research Tunnel (IRT) is used to measure icing characteristics of the IRT's components. The results from the IRT are scaled to the AWT to account for the AWT's larger components and higher velocities. The results show that from 90 to 45 percent of the total spray cloud froze out on the heat exchanger. Furthermore, the first set of turning vanes downstream of the test section, the FOD screen and the fan blades show significant ice formation. The scaling shows that the same results would occur in the AWT.

Newton, J. E.↗

A prototype heat pipe heat exchanger for the capillary pumped loop flight experiment

A Capillary Pumped Two-Phase Heat Transport Loop (CAPL) Flight Experiment, currently planned for 1993, will provide microgravity verification of the prototype capillary pumped loop (CPL) thermal control system for EOS. CAPL employs a heat pipe heat exchanger (HPHX) to couple the condenser section of the CPL to the radiator assembly. A prototype HPHX consisting of a heat exchanger (HX), a header heat pipe (HHP), a spreader heat pipe (SHP), and a flow regulator has been designed and tested. The HX transmits heat from the CPL condenser to the HHP, while the HHP and SHP transport heat to the radiator assembly. The flow regulator controls flow distribution among multiple parallel HPHX's. Test results indicated that the prototype HPHX could transport up to 800 watts with an overall heat transfer coefficient of more than 6000 watts/sq m-deg C. Flow regulation among parallel HPHX's was also demonstrated.

Ku, Jentung↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/temperature/humidity (FIFH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/ temperature / humidity (FTH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗

p-MOSFET total dose dosimeter

A p-MOSFET total dose dosimeter where the gate voltage is proportional to the incident radiation dose. It is configured in an n-WELL of a p-BODY substrate. It is operated in the saturation region which is ensured by connecting the gate to the drain. The n-well is connected to zero bias. Current flow from source to drain, rather than from peripheral leakage, is ensured by configuring the device as an edgeless MOSFET where the source completely surrounds the drain. The drain junction is the only junction not connected to zero bias. The MOSFET is connected as part of the feedback loop of an operational amplifier. The operational amplifier holds the drain current fixed at a level which minimizes temperature dependence and also fixes the drain voltage. The sensitivity to radiation is made maximum by operating the MOSFET in the OFF state during radiation soak.

Buehler, Martin G.↗

Material Studies Related to the Use of NaK Heat Exchangers Coupled to Stirling Heater Heads

NASA has been supporting design studies and technology development that could provide power to an outpost on the Moon, Mars, or an asteroid. Technology development efforts have included fabrication and evaluation of components used in a Stirling engine power conversion system. Destructive material evaluation was performed on a NaK shell heat exchanger that was developed by the NASA Glenn Research Center (GRC) and integrated with a commercial 1 kWe Stirling convertor from Sunpower Incorporated. The NaK Stirling test demonstrated Stirling convertor electrical power generation using a pumped liquid metal heat source under thermal conditions that represent the heat exchanger liquid metal loop in a Fission Power Systems (FPS) reactor. The convertors were operated for a total test time of 66 hr at a maximum temperature of 823 K. After the test was completed and NaK removed, the heat exchanger assembly was sectioned to evaluate any material interactions with the flowing liquid metal. Several dissimilar-metal braze joint options, crucial for the heat exchanger transfer path, were also investigated. A comprehensive investigation was completed and lessons learned for future heat exchanger development efforts are discussed.

Locci, Ivan E.↗