Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Analysis of the Honeywell Uncertified Research Engine (HURE) with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to have ice accrete in two regions of the compression system: region one, which consists of the fan-stator through the inlet guide vane (IGV), and region two which is the first stator within the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDES-MELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan-stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet bulb temperature thresholds were applicable for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applicable to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions.

Veres, Joseph P.↗

Analysis of the Honeywell Uncertified Research Engine (HURE) with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to have ice accrete in two regions of the compression system: region one, which consists of the fan-stator through the inlet guide vane (IGV), and region two which is the first stator within the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDES-MELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan- stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet bulb temperature thresholds were applicable for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applicable to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions.

Veres, Joseph P.↗

Analysis of the Honeywell Uncertified Research Engine with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to provide operating conditions such that ice would accrete in either the fan-stator through the inlet guide vane region of the compression system or within the first stator of the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDESMELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan-stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet-bulb temperature thresholds were applied for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applied to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions. The goal of this study is to show that the computational process developed on earlier engine icing tests can be used to provide an icing risk assessment in adiabatic regions for other engines.

Turbofan engine↗

Conceptual Design of Propulsors for the SUSAN Electrofan Transport Aircrafts

Conceptual designs of the propulsor modules for the SUSAN electro-fan aircraft are sought after. Shaft power requirement is reduced by using boundary layer ingesting propulsion technology. There are several obstacles to designing feasible BLI propulsion systems such as inlet distortion, flow blockage from ingesting low-momentum flow, strong coupling between airframe and propulsion systems. Thus, the high fidelity CFD tool is indispensable to assess the performance of the propulsion systems and evaluate the inlet profiles during the design process. Consequently, the CFD data is used to update the inputs for the NPSS model from the initial stage of the system design. Hence, the inlet sizing, fan design, and estimation of the power saving are carried out. Various installation concepts of the mail-slot nacelle, such as under-/over-wing and trailing edge configurations, are investigated for the wing-mounted turbo-electric distributed propulsor module, and their power-saving is evaluated. As for the tail-mounted turbofan engine, the fan diameter and inlet captured area is determined based on the CFD profiles. An appropriate area ratio of the bypass and core ducts is derived from meeting the target bypass ratio from the system design. The baseline fan stage is analyzed by full annulus URANS CFD to assess the efficiency penalty due to the ingested pressure and swirl distortions.

Electric Aircraft↗

Advancements in Force and Angle Measurement by the NFMTC

The National Force Measurement Technology Capability (NFMTC) is a nationwide partnership established in 2008 and sponsored by NASA’s Aeronautics Evaluation and Test Capabilities (AETC) project to maintain and further develop force and angle measurement capabilities primarily for NASA’s ground test facilities. One of the NFMTC’s primary objectives is to develop new force and angle measurement capabilities to meet the needs of researchers testing in NASA’s ground test facilities. This work will highlight several new capabilities that are either at or near operational readiness. A new six-component flow-through balance was designed and fabricated to support an upcoming retropropulsion test campaign at the NASA Langley Unitary Plan Wind Tunnel. The balance employs membranes in place of bellows, which have historically been used, and passes the flow through load bearing parts of the balance. Flow through the balance is optimized via the addition of flow guides, which are manufactured as separate parts, and attached to the balance. Calibration of this new flow-through balance demonstrates that it can suitably characterize the load and pressure ranges it was designed for, which provides aero researchers a new tool to directly measure retropropulsion performance of powered descent vehicles. Balances used in NASA’s ground test facilities are typically either single-piece balances or floating-frame balances. Historically, these two types of balances have generally used different front-end (model) attachments. Single-piece balances generally have a cylindrical front end that is forward of any measuring sections and at a reduced diameter relative to the balance outer diameter. Floating-frame balances generally have front end fits that extend over one or more measuring sections and that engage at the balance outer diameter. Recently, the NFMTC fabricated a single-piece balance with a front end fit that is compatible with the hardware used to calibrate floating-frame balances. Calibration results evaluating this front end fit will be presented. From a recent survey of angle measurement needs, the development of smaller angle measurement packages was identified as one area of improvement. Micro-electromechanical systems (MEMS) are continually being refined to provide high performance accelerometers that are a fraction of the volume of the quartz flexure based accelerometers that are standard in wind tunnels. A survey of commercial off-the-shelf MEMS accelerometers was conducted, and it identified the Safran Colibrys MS lines to be of adequate performance. Single-axis test boards and tri-axis rigid-flex production boards were designed and fabricated with a volume of approximately .18 cubic inches. The boards were designed to provide all the necessary conditioning for the MEMS accelerometers at levels to meet or exceed all requirements for the MS line sensors. Preliminary testing of these assembled sensor packages has demonstrated acceptable performance for wind-tunnel angle measurement. Several new rotating balances are at various stages of completion for NASA Glenn Research Center’s fan drive rigs. These balances provide direct measurement of thrust and torque of a driven fan or fan section to provide an estimate of fan efficiency and net thrust. Three two-component balances have been recently completed, and one six-component balance is in active development. A custom rotating telemetry system has been developed to support testing with these balances, and the telemetry system is integrated into the forward end of each one. The telemetry system is designed to remove mechanical sliprings by using an optical ethernet-based slipring for data transmission.

Force measurement↗

NASA’s Quiet Electric ENgines (QUEEN): Summary of the QUEEN V2 Test

A liquid-cooled electric ducted fan system was designed, built, and tested at the NASA Glenn Research Center. Main components of the system include a Commercial-Off- the-Shelf (COTS) fan and motor, and a custom-designed heat exchanger integrated into the fan duct. Fan speed, thrust, and cooling system thermal performance was measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V2.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for regional single-aisle aircraft. This test demonstrated the functionality of the QUEEN V2, quantified the thrust produced by the electrofan, and characterized the electrical and thermal performance of the system. Lessons learned will be used to guide development of future QUEEN prototypes.

Aerodynamics↗

NASA’s Quiet Electric ENgines (QUEEN): Summary of the QUEEN V2 Test

A liquid-cooled electric ducted fan system was designed, built, and tested at the NASA Glenn Research Center. Main components of the system include a Commercial-Off- the-Shelf (COTS) fan and motor, and a custom-designed heat exchanger integrated into the fan duct. Fan speed, thrust, and cooling system thermal performance was measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V2.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for regional single-aisle aircraft. This test demonstrated the functionality of the QUEEN V2, quantified the thrust produced by the electrofan, and characterized the electrical and thermal performance of the system. Lessons learned will be used to guide development of future QUEEN prototypes.

Aeronautics-General↗

Past Variations of Water Level of Jezero Paleolake

The western fan of Jezero crater displays features interpreted as fluvial and deltaic sedimentary rocks from orbital data. Images obtained using the SuperCam Remote Micro-Imager (RMI) and the Mastcam-Z camera provide in-situ observations of Jezero crater’s western fan in various locations along the Perseverance traverse. In the last two years, the rover analyzed the fan front from a distance using these imaging tools and at close range using its entire payload. Then, in 2023, the Perseverance rover explored the top of the western Jezero sedimentary fan. Here we show that fluvial topsets and deltaic foresets dominate sedimentary rocks. Determining the boundary between fluvial and prodelta deposits enables us to draw the evolution of the lake level through time.

Mars 2020↗

NASA’s Quiet Electric ENgines (QUEEN): Summary of the Acoustic Tests of the QUEEN V1

Noise produced by an electric ducted fan system was measured in tests at the NASA Glenn Research Center Acoustical Testing Laboratory. Main components of the system include a Commercial-Off-the-Shelf fan, shroud, motor, and Electronic Speed Controller, plus a custom-designed inlet bellmouth, and four experimental inlet duct acoustic liners. Fan speed and noise were measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V1.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for large single-aisle aircraft. Results indicated that inlet duct acoustic liners reduced tone and broadband noise as compared to a hardwall inlet duct. Predicted performance of the honeycomb liner compared well with measurements from an array of far field microphones. Inlet acoustic liners are just one method for mitigating noise for electric ducted fans for aircraft propulsion systems. Lessons learned will be used to guide development of future QUEEN prototypes. Results of a thermal test of the Electronic Speed Controller are presented in a separate report.

Aircraft propulsion and power↗

NASA’s Quiet Electric ENgines (QUEEN): Summary of the Acoustic Tests of the QUEEN V1

Noise produced by an electric ducted fan system was measured in tests at the NASA Glenn Research Center Acoustical Testing Laboratory. Main components of the system include a Commercial-Off-the-Shelf fan, shroud, motor, and Electronic Speed Controller, plus a custom-designed inlet bellmouth, and four experimental inlet duct acoustic liners. Fan speed and noise were measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V1.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for large single-aisle aircraft. Results indicated that inlet duct acoustic liners reduced tone and broadband noise as compared to a hardwall inlet duct. Predicted performance of the honeycomb liner compared well with measurements from an array of far field microphones. Inlet acoustic liners are just one method for mitigating noise for electric ducted fans for aircraft propulsion systems. Lessons learned will be used to guide development of future QUEEN prototypes. Results of a thermal test of the Electronic Speed Controller are presented in a separate report.

Aircraft propulsion and power↗

Motor and drive arrangement for refrigeration system

A heat exchanger system includes a heat exchanger coil circulating a first heat transfer fluid therethrough, and a fan at least partially surrounded by the heat exchanger coil to urge a flow of air through the heat exchanger coil to dissipate thermal energy from the first heat transfer fluid. A brushless direct current fan motor is located the fan to urge rotation of the fan and an ancillary electrical component operably connected to the heat exchanger system and electrically isolated from the first heat transfer fluid.

Feng, Yinshan↗

Performance Assessment of High-Efficiency Refrigerated Display Cases With Low Global Warming Potential Refrigerants

As California policy makers enforce new regulations such as SB 1383 to achieve state greenhouse gas reduction goals, it will be critical to understand the energy efficiency implications of low global warming potential (GWP) refrigerants in commercial refrigeration applications. The goal of this research project, funded by Commonwealth Edison, was to assess the energy performance of two high-efficiency medium-temperature, self-contained, reach-in display cases that utilized natural refrigerant propane (R-290, GWP = 3), and hydrofluorocarbon (HFC) drop-in hydrofluoroolefin R-513A (GWP = 573). Performance of these display cases was compared to a baseline fixture using HFC (R-134A, GWP = 1301) under equal conditions in a controlled environment chamber. These display cases were selected due to their widespread use in convenience stores and small supermarkets. The high-efficiency cases were equipped with energy-efficient lighting, improved panel insulation, high-efficiency evaporator and condenser fan motors, and high-effectiveness heat exchangers. The test method used in this project was foundationally inspired by the ANSI/ASHRAE 72-2018 standard method to evaluate each case under equivalent conditions (ASHRAE 2018). However, minor modifications to this methodology were implemented to better represent more realistic operation of the units. While maintaining equivalent target product temperature, the energy-efficient fixtures A (containing R-290, improved insulation, heat exchangers with a higher overall heat transfer coefficient (higher UA), and more efficient lighting and fan motors) and B (containing R-513A, improved fans, and higher UA-heat exchangers, and more efficient lighting and fan motors) consumed 61.8% to 32.6% less energy, respectively, than a baseline case using R-134A refrigerant. The daily energy consumption of the R-290, R-513A, and baseline display cases at the upper limit of environmental conditions was 4.30, 7.59, and 11.26 kWh/day, respectively.

alternative refrigerants↗

Smart indoor air venting system

A venting system in accordance with the present disclosure includes a ventilation fan and one or more sensors coupled to the ventilation fan. The ventilation fan is positioned to vent air from an indoor environment. The sensors are positioned to monitor conditions in the indoor environment and selectively operate the ventilation fan to condition air in the indoor environment.

Moore, Mike↗

Refractory-based thermal energy storage for industrial process heat: one-dimensional modeling, control, and optimization

The variable and weather-dependent output of wind and solar power plants present a substantial challenge for planning and operating electricity-systems, particularly in the absence of cost-effective and dispatchable energy storage technologies. This study investigates a high-temperature, electrically heated, refractory-based thermal energy storage (RTES) system that stores electrical energy as sensible heat in dense ceramic bricks over the 950–1800 °C range. The stored heat can be discharged as a controlled hot-gas stream for industrial heating, fuel substitution in high-temperature processes, or electricity generation. The main novelty is a comprehensive modelling, control, mapping, and optimization framework that integrates one-dimensional transient gas–solid heat transfer, fan-assisted discharge, bypass-flow regulation, reheating logic, fan-power evaluation, insulation-loss assessment, and genetic-algorithm-based design optimization. The model uses feedback from outlet temperature and delivered power to regulate discharge, while a two-stage genetic algorithm optimizes brick-channel geometry, gas-flow operation, and multilayer insulation thicknesses. Storage capacities below 50 MWh and discharge powers of 5–30 MW are analyzed to evaluate hold time, thermal delivery, fan-power penalty, heat loss, state-of-charge evolution, and indicative capital cost. Results demonstrate that optimized and well-insulated refractory-based thermal energy storage units can provide stable, efficient, and repeatable heat delivery over multiple discharge cycles. The generated performance and cost maps support modular refractory thermal energy storage as a practical option for large-scale integration of wind and solar generation and for high-temperature industrial process heat.

25 ENERGY STORAGE↗

Acoustic Results of Over the Rotor and Soft Vane Treatments on the Source Diagnostic Test Model in the NASA Glenn Research Center 9- by 15-foot Low-Speed Wind Tunnel

Two novel fan noise reduction concepts were tested using the Source Diagnostic Test fan stage model in the NASA Glenn 9x15 Low Speed Wind Tunnel. One, referred to as over the rotor treatment, consisted of a number of different casing treatments some of which contained acoustic treatment. The other, known as soft vane, consisted of fan exit guide vanes whose interior volume contained acoustic treatment that was exposed to the vane suction side surface through a perforate.

Aeroacoustics↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Steady-state off-design modeling of the supercritical carbon dioxide recompression cycle for concentrating solar power applications with two-tank sensible-heat storage

Concentrating solar power researchers are evaluating the potential of the supercritical carbon dioxide recompression cycle to improve the thermal efficiency and decrease the capital costs of next-generation systems. This analysis investigates the steady-state off-design performance of a recompression cycle integrated with two-tank sensible-heat thermal energy storage as the ambient temperature and heat-transfer fluid (HTF) inlet conditions to the cycle change. This paper presents off-design component models and then cycle convergence and control models to maximize net cycle power output while constraining the high-side pressure and air-cooler fan power to their respective design values and fixing the cycle HTF outlet temperature to its design value. Results show that inventory control and air-cooler fan power are important control parameters that can be optimized to maximize off-design power output as the ambient temperature and HTF mass flow rate diverge from design. The high-side pressure and fan power constraints cause the cycle net power to degrade when the ambient temperature is warmer than the design value, and this study calculates a maximum mass flow rate for hot days above which the cycle cannot achieve the design HTF outlet temperature. Finally, the analysis shows that optimizing compressor shaft speeds can improve cold-day performance by around 1.5 percentage points and part-load performance by up to 2.5 percentage points versus a baseline case with no active compressor control.

14 SOLAR ENERGY↗