Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLAT PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Installation guidelines for solar heating system, single-family residence at William OBrien State Park, Stillwater, Minnesota

Installation procedures for the single family residential solar heating system at the William O'Brien State Park, Stillwater, Minnesota, are presented. The system is a solar-assisted, hydronic-to-warm-air system with solar-assisted domestic water heating. It is composed of the following major components: liquid cooled flat plate collectors; water storage tank; passive solar-fired domestic water preheater; electric hot water heater; heat pump with electric backup; solar hot water coil unit; tube-and-shell heat exchanger, three pumps, and associated pipes and valving in an energy transport module; control system; and air-cooled heat purge unit. Installer guidelines are provided for each subsystem and includes testing and filling the system. Information is also given on the operating procedures, controls, caution requirements and routine and schedule maintenance.

Source record↗

Non-Synchronous Whirling Due to Fluid-Dynamic Forces in Axial Turbo-Machinery Rotors

The role of fluid forces acting on the blades of an axial turborotor with regards to whirling was analyzed. The dynamic equations were formulated for the coning mode of an overhung rotor. The exciting forces due to the motion were defined through a set of rotor stability derivatives, and analytical expressions of the aerodynamic contributions were found for the case of small mean stream deflection, high solidity and equivalent flat plate cascade. For a typical case, only backward whirl was indicated when the phase shifting of the rotor wake effect was ignored. A parametric study of the dynamic stability boundary reveals that a reduction in blade stagger angle, mass flow rate, fluid density and an increase in stiffness and external damping are all inductive for improved stability.

Shen, S. F.↗

Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas

A solar heating on cooling system is described which is designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 solargenics, series 76, flat plate collectors with a total area of 1,596 square feet. The solar loop circulates an ethylene glyco water solution through the collectors into a hot water system exchanger. The water storage subsystem consists of a heat exchanger, two 2,300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water water fixtures. The building cold water system provides make up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described.

Source record↗

Solar heating and cooling system installed at Leavenworth, Kansas

A solar heating and cooling is described which is designed to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2,200 square feet. Five 3 ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3,000 gallon chilled water storage tank. Two 3,000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.

Source record↗

Solar space heating for the Visitors Center, Stephens College, Columbia, Missouri

The solar energy system located at the Visitors' Center on the Stephens College Campus, Columbia, Missouri is discussed. The system is installed in a four-story, 15,000 square foot building. The solar energy system is an integral design of the building and utilizes 176 hydronic flat plate collectors which use a 50 percent water ethylene blycol solution and water-to-water heat exchanger. Solar heated water is stored in a 5,000 gallon water storage tank located in the basement equipment room. A natural gas fired hot water boiler supplies hot water when the solar energy heat supply fails to meet the demand. The designed solar contribution is 71 percent of the heating load.

Source record↗

Solar energy system performance evaluation report for IBM System 4 at Clinton, Mississippi

The IBM System 4 Solar Energy System is described and evaluated. The system was designed to provide 35 percent of the space heating and 63 percent of the domestic hot water preheating for a single family residence located within the United States. The system consists of 259 square feet of flat plate air collectors, a rock thermal storage containing 5 1/2 ton of rock, heat exchangers, blowers, a 52 gallon preheat tank, controls, and associated plumbing. In general, the performance of the system did not meet design expectations, since the overall design solar fraction was 48 percent and the measured value was 32 percent. Although the measured space heating solar fraction at 32 percent did agree favorably with the design space heating solar fraction at 35 percent, the hot water measured solar fraction at 33 percent did not agree favorably with the design hot water solar fraction of 63 percent. In particular collector array air leakage, dust covered collectors, abnormal hot water demand, and the preheat tank by pass valve problem are main reasons for the lower performance.

Source record↗

Solar heating and domestic hot water system installed at Kansas City, Fire Stations, Kansas City, Missouri

The solar system was designed to provide 47 percent of the space heating, 8,800 square feet area and 75 percent of the domestic hot water (DHW) load. The solar system consists of 2,808 square feet of Solaron, model 2001, air, flat plate collector subsystem, a concrete box storage subsystem which contains 1,428 cubic feet of 0.5 inch diameter pebbles weighing 71.5 tons, a DHW preheat tank, blowers, pumps, heat exchangers, air ducting, controls and associated plumbing. Two 120 gallon electric DHW heaters supply domestic hot water which is preheated by the solar system. Auxiliary space heating is provided by three electric heat pumps with electric resistance heaters and four 30 kilowatt electric unit heaters. There are six modes of system operation.

Source record↗

Gallium arsenide (GaAs) solar cell modeling studies

Various models were constructed which will allow for the variation of system components. Computer studies were then performed using the models constructed in order to study the effects of various system changes. In particular, GaAs and Si flat plate solar power arrays were studied and compared. Series and shunt resistance models were constructed. Models for the chemical kinetics of the annealing process were prepared. For all models constructed, various parametric studies were performed.

Heinbockel, J. H.↗

Interaction between a normal shock wave and a turbulent boundary layer at high transonic speeds. Part 1: Pressure distribution. Part 2: Wall shear stress. Part 3: Simplified formulas for the prediction of surface pressures and skin friction

An asymptotic description is derived for the interaction between a shock wave and a turbulent boundary layer in transonic flow, for a particular limiting case. The dimensionless difference between the external flow velocity and critical sound speed is taken to be much smaller than one, but large in comparison with the dimensionless friction velocity. The basic results are derived for a flat plate, and corrections for longitudinal wall curvature and for flow in a circular pipe are also shown. Solutions are given for the wall pressure distribution and the shape of the shock wave. Solutions for the wall shear stress are obtained, and a criterion for incipient separation is derived. Simplified solutions for both the wall pressure and skin friction distributions in the interaction region are given. These results are presented in a form suitable for use in computer programs.

Adamson, T. C., Jr.↗

Wind tunnel investigation of the Titan Forward Skirt compartment vent from a free-stream Mach number of 0.80 to 1.96

A test was conducted to determine the flow characteristics of the Titan forward skirt compartment vent over a free stream Mach number range of 0.80 to 1.96. The vent was mounted in a flat plate and the plate was flush mounted to the tunnel side wall with coinciding center lines. Air was discharged from a duct, located on the tunnel side wall behind the plate, through a canted aft 30 deg honeycomb vent into the free stream. Data for the analysis of the Titan forward skirt compartment venting during ascent through the atmosphere are provided. Full scale simulated flight hardware, such as the honeycomb vent, duct corrugations and field joint ring were used. Boundary layer thicknesses were used to vary boundary height. The highest vent discharge coefficient for any given Mach number and vent pressure ratio generally occurred at the maximum displacement thickness. With no vent flow the static pressure in the vent region was generally less than the free stream static pressure. With vent flow, the static pressures upstream of the vent increased, and those downstream of the vent decreased.

Johns, A. L.↗

The dynamics and control of large flexible space structures. Volume 3, part B: The modelling, dynamics, and stability of large Earth pointing orbiting structures

The dynamics and stability of large orbiting flexible beams, and platforms and dish type structures oriented along the local horizontal are treated both analytically and numerically. It is assumed that such structures could be gravitationally stabilized by attaching a rigid light-weight dumbbell at the center of mass by a spring loaded hinge which also could provide viscous damping. For the beam, the small amplitude inplane pitch motion, dumbbell librational motion, and the anti-symmetric elastic modes are all coupled. The three dimensional equations of motion for a circular flat plate and shallow spherical shell in orbit with a two-degree-of freedom gimballed dumbbell are also developed and show that only those elastic modes described by a single nodal diameter line are influenced by the dumbbell motion. Stability criteria are developed for all the examples and a sensitivity study of the system response characteristics to the key system parameters is carried out.

Bainum, P. M.↗

Solar heating system at Quitman County Bank, Marks, Mississippi

Information on the Solar Energy Heating System installed in a single story wood frame, cedar exterior, sloped roof building is presented. The system has on-site temperature and power measurements readouts. The 468 square feet of Solaron air flat plate collectors provide for 2,000 square feet of space heating, an estimated 60 percent of the heating load. Solar heated air is distributed to the 235 cubic foot rock storage box or to the load (space heating) by a 960 cubic feet per minute air handler unit. A 7.5 ton Carrier air-to-air heat pump with 15 kilowatts of electric booster strips serve as a back-up (auxiliary) to the solar system. Motorized dampers control the direction of airflow and back draft dampers prevent thermal siphoning of conditioned air.

Source record↗

Pulsed plasma thruster contamination studies

The exhaust plume of the one millipound pulsed plasma thruster has a measurable backflow upstream of the nozzle exit plane which may deposit on and degrade the performance of exposed spacecraft surfaces. High speed photographs and Faraday cup measurements suggest that this backflow is predominantly an electrically neutral, relatively low energy vapor. Articulated collimator quartz crystal microbalance measurements of this backflow were made for a thruster with a radically modified nozzle and a flat plate backflow shield, to determine the backflow sensitivity to nozzle design changes. The results are compared with the original nozzle backflow and show a measurable reduction in the backflow directly upstream of the shield.

Rudolph, L. K.↗

Effect of transverse shear and material orthotropy in a cracked spherical cap

The elastostatic problem for a relatively thin-walled spherical cap containing a through crack is considered. The problem is formulated for a specially orthotropic material within the confines of a linearized, shallow shell theory. The theory used is equivalent to Reissner's theory of flat plates and hence permits the consideration of all five physical conditions on the shell boundaries separately. The solution of the problem is reduced to that of a pair of singular integral equations and the asymptotic stress state around the crack tips is investigated. The numerical solution of the problem is given for an isotropic shell and for two specially orthotropic shells. The results indicate that the material orthotropy as well as the shell curvature and thickness may have a considerable effect on the stress intensity factors at the crack tips.

Delale, F.↗

Aerodynamic heating for gaps in laminar and transitional boundary layers

The presence of gaps, slots, and/or steps in a surface may significantly perturb a supersonic boundary layer. The paper discusses heat-transfer distributions for a variety of gap configurations which were obtained by placing instrumented inserts in a flat-plate structural carrier. The data were obtained in a 3.50 foot hypersonic wind tunnel at a freestream Mach number of 5.10 over a range of Reynolds number from 2,570,000 to 8,110,000. The variables of the test program included the freestream Reynolds number and the gap configuration, e.g., width, depth, step height, number, and orientation.

Bertin, J. J.↗

A two-dimensional potential flow model for ground-induced effects on jet and fan inlets

A free-streamline potential flow model is developed for the flowfield external to a stationary jet or fan inlet in proximity to a ground plane. It is assumed that the flow is steady, incompressible, and irrotational. A two-dimensional flat plate geometry models the inlet configuration, and free streamline theory is used to avoid unrealistic infinite flow velocities at the lips of the inlet, and to account somewhat for flow separation. A water table experiment is used to verify the analytical results. The fact that the solutions are found to be limited to only a certain range of diameter-height ratios implies an overdetermination of the problem by free streamline theory. Also studied are the convective properties of small vortical disturbances superimposed on the ideal flow solution.

Newman, W. H.↗

Heat transfer through turbulent boundary layers - The effects of introduction of and recovery from convex curvature

Measurements have been made of the heat transfer through a turbulent boundary layer on a convexly curved isothermal wall and on a flat plate following the curved section. Data were taken for one free-stream velocity and two different ratios of boundary layer thickness to radius of curvature delta/R = 0.051 and delta/R = 0.077. Only small differences were observed in the distribution of heat transfer rates for the two boundary layer thicknesses tested, although differences were noted in the temperature distributions within the boundary layer

Simon, T. W.↗

Comparison of single crack propagation in lunar analogue glass and the failure strength of rocks

New data of crack propagation in lunar analogue glass provides important input for the construction of deformation maps (maps which delineate the rates and principal means of material deformation under various environmental conditions) applicable to the lunar crust. Comparison of single crack propagation data obtained on flat plates of glass and failure strength data obtained on fine grained rock samples show that single crack propagation velocities are directly related to the failure strength of rocks. The chemical reaction between water and silicon-oxygen bonds at the crack tip seems to be of first order. This greatly simplifies extrapolation to low partial pressures of H2O

Soga, N.↗