Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEEDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Calculation of Glycolate Concentration Factors Across the 242-25H (3H) Evaporator System

Two models were developed to predict glycolate concentration factors across the 242-25H (3H) Evaporator system. The first model, identified as the Unrestricted Evaporation Model, was designed to evaluate concentration of typical 3H feed material to relatively high densities in order to calculate the concentration factor of glycolate in a given feed stream. This model may be used to understand the potential of glycolate to concentrate from a generic feed material through the 3H system. The second model, identified as the Holistic Evaporation Model, was designed to evaluate the evaporation of dilute, glycolate-containing Defense Waste Processing Facility (DWPF) waste with the requirement that high silicon concentrations typical of recycle material require dilution to adhere to current technical safety requirements. This model may be used to understand the potential of glycolate from DWPF recycle material to concentrate as a result of feeding through the 3H system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NH 4 OH Looping with Membrane CO 2 Absorber and Distributed Stripper for Enhanced Algae Growth

The University of Kentucky Center for Applied Energy (UK CAER) has devised a unique, integrated CO2 capture and utilization technology. CO2 from coal-fired power generation flue gas is first captured at half the operating cost of a typical aqueous CO2 capture system (CCS), distributed in an aqueous stream and then fixed by algae in bioreactors where the algae production is increased by 50% over that with a typical intermittent nutrient feeding system. Lower CCS operating cost is achieved by eliminating the flue gas pretreatment step for cooling and SO2 removal, eliminating steam extraction from the power generation steam cycle for solvent regeneration, and eliminating CO2 compression. Higher algae production is achieved by continuous, just-in-time nutrient feed to the bioreactors directly from a distributed solvent regenerator, which maintains the bioreactor pH for optimum growth. The process starts with a uniquely configured membrane absorber, where the flue gas is indirectly contacted with an ammonium hydroxide (NH4OH) solvent. Dissolved NH3 is attractive for both CO2 capture and as an algae nutrient. For CO2 capture it is inexpensive, has a low regeneration energy, is thermally- and oxidatively-stable and has a viscosity near that of water, which makes is easy to transport. Numerous studies have shown that the scrubbing capacity of NH3 is approximately 0.9-1.2 kg of CO2/kg of NH3, with a CO2 removal efficiency of ~99% and half the solvent regeneration energy than that of 30 wt% MEA[1, 2, 3]. NH3 is attractive as an algae nutrient due to its low cost. The rich NH4OH solvent is pumped to a set of distributed regenerators which are co-located with the algae bioreactors. Solvent pumping, transport and distribution reduces the balance of plant (BOP) cost compared to a typical aqueous CCS related to the flue gas duct and boost fan required to transport the flue gas. The energy required for the distributed solvent regeneration is supplied by solar-thermal panels eliminating the need for steam extraction from the power generation steam cycle. After solvent regeneration, the product stream contains both the CO2 captured from the flue gas and volatized NH3 from the solvent. This product stream is fed directly to the bioreactors, eliminating the need for compression of the CO2 stream. The relative amounts of CO2 and NH3 in the product stream are adjusted and controlled by a controlling the regeneration conditions (pressure and temperature). The continuous feed of the right ratio of nutrients overcomes the typical inhibition of algae growth resulting from frequent pH swings in the bioreactor due to unbalanced (intermittent) feeding systems for CO2 and N. Also, because the regenerators will operate at pressure and be located in close proximity to the bioreactors, there is no worry about pressure drop when sparging the gas into the algae. Sparging produces small bubbles which is beneficial for mass transfer efficiency. One known challenge when using an NH4OH solvent is high NH3 emission. Hydrophobic membranes are used for CO2 capture using an aqueous NH3 solution[4, 5] without the direct contact between flue gas and aqueous solution. Additionally, UK CAER CO2 capture and utilization process manages NH3 slip in three extra measures. First, NH3 slip is minimized by working with minimal species partial pressure, which is proportional to the concentration in the liquid. Hence, lowering the capture solvent concentration will lower the NH3 partial pressure. Second, UK CAER’s previous work has demonstrated that the addition of Zn2+ into NH3 solutions to chelate the NH3 can reduce NH3 volatility. Third, the configuration of the membrane CO2 absorber utilizes condensed water from the flue gas to continually wash the gas-side of the membrane to reduce fouling and recapture NH3 slip. Additional details about the UK CAER unique, integrated CO2 capture and utilization technology will be presented along with technology development plans. Diao, N., Q. Li, and Z. Fang. 2004. Heat transfer in ground heat exchangers with groundwater advection. International Journal of Thermal Sciences. 43: 1203-1211, He, Q., M. Chen, L. Meng, K. Liu, and W. Pan. 2004. Study on Carbon Dioxide Removal from Flue Gas by Absorption of Aqueous Ammonia. Western Kentucky University. Yeh, A.C., and H. Bai. 1999. Comparison of ammonia and monoethanolamine solvents to reduce CO2 greenhouse gas emissions. The Science of the Total Environment. 228: 121-133, Villeneuve, K., D. Roizard, J.C. Remigy, M. Iacono, and S. Rode. 2018. CO2 capture by aqueous ammonia with hollow fiber membrane contactors: Gas phase reactions and performance stability. Separation and Purification Technology, 199: 189-197, Toro Molina, C., and C. Bouallou. 2016. Carbon dioxide absorption by ammonia intensified with membrane contactors. Clean Techn Environ Policy 18, 2133–2146 (2016)

20 FOSSIL-FUELED POWER PLANTS↗

White Paper to Justify the Use of Strip Effluent in the Defense Waste Processing Facility During Slurry Mix Evaporator Processing

At the request of Savannah River Remediation (SRR), a white paper was written to assess whether it would be acceptable to process Strip Effluent (SE) in both the Sludge Receipt and Adjustment Tank (SRAT) and Slurry Mix Evaporator (SME) in the Defense Waste Processing Facility (DWPF) for the nitric-glycolic acid flowsheet. Savannah River National Laboratory (SRNL) experimental data and DWPF Sludge Batch 9 (SB9) process data was reviewed, looking at batches which included Precipitate Reactor Feed Tank (PRFT) and/or Strip Effluent Feed Tank (SEFT) feeds that led to long processing times. These batches were reviewed looking for processing problems such as melter feed trips, foamovers, heating rod or steam coil fouling, missed Reduction/Oxidation (REDOX) targets, and other process anomalies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distribution of U, Pu and Np in a Mo-99 Recovery Process using Sachtopore NP (titania based) Absorbent Material

A laboratory scale mockup of a prototypical Mo-99 recovery process has been operated in a radioactive materials hood at Savannah River National Laboratory. This equipment has been operated with realistic concentrations of uranium (U-238), plutonium (94% Pu-239), neptunium (Np-237), and non-radioisotopes of common fission products (including Mo). The goal of this work was to determine the amounts of U, Pu, and Np in the liquid waste streams created by the wash streams for the production process. The key question was how the initial acid wash volume will be handled, as this solution contains residual raffinate which amounted to ~ 3% ofthe mass ofthe feed solution in this experiment. If the initial 1.9 bed volumes (BV) of acid wash were recycled as in this experiment then the combined wash solutions can be expected to contain 0.4 g U/L, 2.7 pg Pu/L and < 14 pg Np/L. If, on the other extreme, the entire acid wash solution was discarded as waste, then the combined wash solutions can be expected to contain 11 g U/L, 3.8 pg Pu/L and ~ 80 pg Np/L. The Sachtopore NP absorbent (for Mo-99 recovery) retains a minuscule fraction ofthe U (2.3 mg U per g titania or 0.03% ofthe U in the feed). The uncertainties are too large to determine how close the absorbent is to saturation with U. Less mass but a higher fraction ofthe total Np was retained by the absorbent (0.7 pg Np per g titania or ~2% of the Np in the feed). As has been reported elsewhere, a large fraction ofthe Pu fed to the titania bed was retained by the absorbent (92% of Pu in the feed or 20 pg per g titania).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fiscal Year 2022. Filtration of Hanford Tank 241-AP-101 Supernatant at 16 °C

Bench-scale filtration testing of ~9 liters of supernatant from Hanford waste tank 241-AP-101, chilled to 16 °C, was conducted using a backpulse dead-end filter (BDEF) filtration system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. This was done to assess the performance of the anticipated third feed to the Tank Side Cesium Removal (TSCR) system. The as-received samples were diluted to the target sodium concentration and transferred to 1.5-liter polyethylene bottles and held at 16 °C for approximately 1 week prior to filtration. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 to match the prototypic operation of the TSCR system. During filtration, the differential pressure required to effect filtration at 0.065 gpm/ft 2 increased little over the filtration campaign and never reached 2 psid (the TSCR action limit). This indicates that the TSCR filter should perform well when processing AP-101 supernatant. After completing filtration of the AP-101 feed, the filter was cleaned. Solids concentrated from the backpulse solutions displayed sodium nitrate-type phases, aluminum and silicon phases reported as cancrinite or nitrate-cancrinite, a mixed chromium-aluminum oxide, iron oxides, and Ca-bearing phases (calcite). Scanning electron microscopy analyses showed that the average particle size was 0.5 micron.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resource Recovery and Environmental Protection in Wyoming’s Greater Green River Basin Using Selective Nanostructured Membranes (Final Report)

Produced water (PW) represents a sizable waste stream that is co-generated with oil and natural gas production. In 2021 Wyoming ranked 8th and 9th, respectively in domestic oil and natural gas production. In 2017 Wyoming ranked as the 4th highest generator of PW in the U.S, accounting for 7% of the total volume generated. In the context of being the 3rd most arid state in the U.S., the value of water reuse becomes obvious. PW reuse, and resource recovery, in any form requires some level of treatment to remove particulates, residual (free, dispersed) hydrocarbons, organics, and salts. The level of treatment depends on the requirements of the reuse, or resource recovery, application. PW management systems in Wyoming employ in order of volume of PW managed the following management strategies: reinjection for enhanced oil recovery, surface discharge, deep well injection, evaporation ponds (impoundments), and commercial management/treatment. Complicating treatment efforts are the relatively high concentrations of organics (natural and synthetic), dispersed/free hydrocarbons, benzene-toluene-ethylbenzene, and xylenes (BTEX) compounds, biologicals, salts, and minerals. Hydrocarbons (dispersed/dissolved crude oils) and BTEX compounds, as well as synthetic organics, present economic and environmental concerns. The former represents lost revenue, while the latter results in negative environmental impacts like emissions from surface impoundments. The overall objective of this proposal was to synthesize superhydrophilic/oleophobic and superhydrophobic/oleophilic membranes for selectively concentrating and then separating BTEX compounds and oil and grease (O&G) from PW originating from the Greater Green River Basin (GGRB) in Wyoming. Three specific research aims were pursued to accomplish this overall objective. This final report details the development of the superhydrophobic and superhydrophilic membranes, as well as the design of the membrane module prototypes specifically. The technoeconomic assessment is separately reported in another document. 1. Aim #1 – Material optimization and performance evaluation of superhydrophilic/oleophobic and superhydrophobic/oleophilic membranes made by electrospinning/spraying. 2. Aim #2 – Design and construction of cross-flow membrane modules for selectively concentrating and then separating BTEX/oil from GGRB produced water. 3. Aim #3 – Techno-economic assessment of BTEX/oil recovery, and clean water production, using superhydrophilic/oleophobic and superhydrophobic/oleophilic membrane separation for GGRB PW. Superhydrophobic membranes were synthesized by electrospinning poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) nanofibers onto polyester (PET) substrates and electrospraying nano-carbon black/PVDF-HFP onto the nanofibrous layer. These membranes were characterized by high (>8000 liters per square meter per hour per bar (LMH/bar)) permeance values for pure hydrocarbon phases and a high hydrocarbon selectivity (>96%) when treating GGRB PW. All results were obtained when operating the membrane in a crossflow configuration representative of actual field operating conditions. Solvent/oil properties, specifically viscosity and total surface energy/tension, affected permeance across the membrane, which resulted in light mineral oil (394 LMH/bar) and o-xylene (1834 LMH/bar) being characterized by lower permeance values in the pure phase tests. Mixed phase fluxes between 40 to 80 LMH were obtained for the PW when operating the membrane at a feed pressure of 0.3 bar. Flux decreased as the mixed phase concentration in the feed decreased pointing to the importance of maximizing the collision efficiency between the emulsion and the membrane surface and maximizing the emulsion concentration in the feed and the turbulence within the feed channel. These tests demonstrated that the superhydrophobic membranes developed here are a viable hydrocarbon recovery method for GGRB PWs and should be pursued for testing in pilot-scale trials. Superhydrophilic membranes were successfully synthesized via electrospinning/spraying using polyacrylonitrile (PAN) nanofibers as a base nanofibrous matrix. Integration of polyaniline (PANI) into the nanofibrous matrix produced a superior membrane, for water filtration applications, relative to PAN alone and reduced graphene oxide (RGO) when integrated into the nanofibrous matrix. This conclusion was based on the PANI-PAN resistance to flux loss (fouling) when treating model solvent/oil solutions representative of GGRB PWs and field collected PW from the GGRB. The synthesized PAN membranes outperformed a commercially available PAN membrane designed for oil/water separation. This finding indicates that the surface chemical and physical characteristics of the electrospun membranes presents improved properties for filtration of challenging waters like GGRB PWs. The electrospun membranes therefore show promise overall as a substitute for conventionally polymerized membranes in PW treatment applications. The PANI-PAN membrane specifically presents superior performance characteristics for concentration O&G prior to treatment by the hydrocarbon recovery membrane and producing high-quality filtrate for reuse and/or additional treatment (desalination).

02 PETROLEUM↗

Front End Engineering Design of Linde-BASF Advanced Post-Combustion CO 2 Capture Technology at a Southern Company Natural Gas-Fired Power Plant (Final Scientific/Technical Report)

This document details the execution of Cooperative Agreement DE-FE0031847, “Front End Engineering Design of Linde-BASF Advanced Post-Combustion Carbon Dioxide (CO 2 ) Capture Technology at a Southern Company Natural Gas-Fired Power Plant” during the period of 10/1/2019 to 6/30/2022. The project was funded by the U.S. Department of Energy’s Office of Fossil Energy and Carbon Management (FECM) and managed by the National Energy Technology Laboratory (NETL). Southern Company Services, Inc. (SCS) was the prime recipient and led the project team. Other members of the project team included Linde, Inc. (Linde), Linde Engineering – Dresden (LED), and BASF. The overall goal of the project was to complete a front-end engineering design (FEED) study for installing the Linde-BASF post-combustion capture (PCC) technology at an existing domestic natural gas-fired combined cycle (NGCC) power plant within Southern Company’s portfolio of assets. The CO 2 capture plant was to be of commercial scale (at least 375 MWe) and include process units for pre-conditioning of the flue gas system, the CO 2 capture plant island, storage vessels, the CO 2 compression train, and any necessary components for integration into the NGCC plant. Mississippi Power’s Plant Daniel Unit #4 was chosen as the host site for the FEED with the target of capturing 90% of CO 2 emissions from the existing combustion turbines. The information produced by the FEED was used to develop a cost estimate of +/- 15% accuracy. Capital costs, excluding financing, are estimated at approximately $\$752$ million dollars (2021). The execution of a project based on this FEED study has an estimated duration of almost five years.

03 NATURAL GAS↗

Cesium Removal from 5.5 and 7.0 M Na AP-105 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational by Washington River Protection Solutions LLC (WRPS), prepares initial low-activity Hanford waste tank supernate feeds for the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP as governed by a waste acceptance criterion (WAC). Specific to 137 Cs, this requirement is < 3.18E-5 Ci 137 Cs/mole of Na. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), has been selected as the ion exchange media for TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, testing to date on actual tank waste samples has been limited to Na concentrations between 5 and 6 M Na (Fiskum et al. 2019a, 2021b and Westesen et al. 2021a, 2021b, 2022) while actual tank conditions can reach upwards of 9 M Na. Testing with feed from Hanford tank AP-105 incorporated testing at both 5.5 and 7 M Na in order to evaluate the impact of Na concentration on volume of waste processed before reaching the WAC. A 6-L volume of 5.5 M Na AP-105 and an 8-volume of 7 M Na AP-105 was processed through the Radioactive Waste Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 6- to 9-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.9 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. Table S.1 and Figure S.1 summarize the measured AP-105 Cs load performance for each feed condition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY 23 Filtration of Hanford Tank 241-SY-101 Supernatant at 16 °C

Approximately 9 liters of supernatant from Hanford waste tank 241-SY-101 was delivered by Washington River Protection Solutions to the Radiochemical Processing Laboratory (RPL) at Pacific Northwest National Laboratory. The thirty-six SY-101 sample bottles were comprised of six sets of six samples, with each set pulled from a unique tank sampling level. Prior to testing, samples from each level were composited to provide nominally level-independent feed for dead end filtration and ion exchange testing. The composited 241-SY-101 supernatant was chilled to 16 °C for 1 week prior to testing. Filtration testing was then conducted using a backpulse dead-end filter (BDEF) system equipped with a feed vessel and a Mott inline filter Model 6610 (Media Grade 5) in the hot cells of the RPL. This was done to provide waste processing benchmarks for 200 West Area wastes in the West Area Risk Management project. The feed was filtered through the BDEF system at a targeted flux of 0.065 gpm/ft 2 . During filtration of the differential pressure required to effect filtration at 0.065 gpm/ft 2 increased little over the filtration campaign and never reached 2 psid (the Tank Side Cesium Removal system action limit). This indicates that the Media Grade 5 filter should perform well when processing SY-101 supernatant. After completing filtration of the SY-101 feed, the filter was cleaned. Solids concentrated from the backpulse solutions displayed calcium phosphate, aluminum oxides, aluminum-chromium nanoparticle agglomerates. Electron diffraction was used to determine the types of phases that were present in the solids. Most of the phases found were only weakly crystalline, possibly owing to their rapid precipitation during the process water treatment. The identifications of the phases therefore are tentative.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recommendations for Reduction in Radionuclide Analyte Analysis in Support of WTP Operations

In support of Hanford Tank Waste Treatment and Immobilization Plant (WTP) direct feed low-activity waste operations, this document seeks to provide a discussion on currently required radionuclide sample analyses and which, if any, are planned but may not be needed. The total number of analyses is more than 10,000 per year and, often, this analytical endeavor is difficult due to troublesome components. Such components cause issues due to low concentrations, difficulty of analysis, lack of standards, or other reasons. One of the main goals is to remove onerous or troublesome components that are present in low enough concentrations to not pose a threat of the resulting waste form being non-compliant if not measured. Additionally, if it can be demonstrated that the large number of analyses is not needed, then that will save hold times in operations, decrease the amount of money required for operations, and reduce potential exposure for plant staff or researchers. Suggestions are provided for radionuclide analytes that may not be needed and can be safely estimated from process knowledge documented in the best basis inventory. The analytes recommended for removal were determined via calculations using batch feed estimates from the Tank Utilization Assessment of 2013. Approximately 750 feed estimates, representing waste compositions throughout the lifetime of the Hanford mission, were analyzed, and radionuclide concentrations were compared against established reporting and contractual limits as specified in the WTP contract. Analytes that were found to be consistently below the limits include many transuranic radionuclides and other radionuclides present in the waste in small concentrations. A total of 23 of the 44 radionuclides in the batch estimates were not significant in all batch feeds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Retrofittable Advanced Combined Cycle Integration for Flexible Decarbonized Generation

This is the final scientific / technical report for Front End Engineering Design (FEED) study “Retrofittable Advanced Combined Cycle Integration for Flexible Decarbonized Generation” funded by the US Department of Energy (DOE), Office of Fossil Energy and Carbon Management (FECM), Carbon Capture R&D Program under award DE-FE0032131. The prime recipient is General Electric Company working through its Gas Power division (GEGP) with subrecipients Southern Company and Linde Engineering plus subcontractor Kiewit. Southern Company’s Plant Barry, a 2x1 7F.04 CCGT, is the host site. GEGP led the overall integration of the carbon capture system (CCS) with the existing natural gas combined cycle (NGCC) facility. Linde provided the detailed process engineering and equipment costing for the carbon capture island. Kiewit focused on plant layout, constructability, and installation. With the FEED study finished, the engineering is approximately 50% complete towards the detailed design package needed to proceed to procure, install, build, commission, and operate the integrated NGCC+CCS facility. This FEED study focuses on retrofitting a 95% CO 2 capture system with attention on plant integration. The study was particularly challenging due to unique and substantial cost impacts related to global sourcing challenges associated with COVID. Additional incentives, regulatory support, and dispatch certainty are needed to move forward with implementing CCS at this or other sites in the US. This FEED study highlights the value of integrating NGCC+CCS and is a template for future CCS retrofit studies.

42 ENGINEERING↗

Low Carbon Intensity Formic Acid Chemical Synthesis from Direct Air Captured CO 2 Utilizing Chemical Plant Waste Heat - Final Technical Report

The primary objective of Low Carbon Intensity Formic Acid Chemical Synthesis from Direct Air Captured CO 2 Utilizing Chemical Plant Waste Heat (ChemFADAC) is to execute and complete a FEED study for an integrated direct air capture (DAC) and carbon conversion system (together, the DACUS system) co-located at a Nutrien nitric acid production facility in Kennewick, WA capable of capturing and converting a minimum of 5,000 MT/year net atmospheric CO 2 to low carbon intensity formic acid (FA) using industrial waste heat and renewable electricity. The goal will be achieved through the completion of four objectives using a collaborative approach with community stakeholders. Objective 1. Conduct a FEED study and Class 3 project cost estimate for the proposed DACUS system that maximizes use of thermal energy from the Nutrien KFO host site to produce low carbon intensity FA from atmospheric CO 2 . Objective 2. Perform a cradle-to-gate life-cycle analysis of the DACUS system to determine the environmental sustainability and carbon intensity (CI) of the proposed project and product from the results of the FEED study. Objective 3. Perform a business case analysis from results of the LCA, FEED study and cost estimate to justify investment to build the DACUS project at the Nutrien KFO site. Objective 4. Quantify how deployment of the proposed technology will promote and prepare a ready workforce for clean energy and manufacturing jobs and coordinate with community stakeholders to perform an environmental justice and a preliminary economic revitalization and job creation outcomes analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alaska Liquid Natural Gas Pipeline Front-End Engineering & Design (Final Technical Report)

The Alaska Gasline Development Corporation (AGDC) is Alaska’s natural gas infrastructure development corporation established in 2013. AGDC’s mission is to maximize the benefit of Alaska’s vast North Slope natural gas resources for Alaskans through the development of infrastructure necessary to move the gas into local and international markets. AGDC was identified for a Congressionally Directed Spending (CDS) project for funding in the Energy and Water Development and Related Agencies Appropriations Act, 2023 under the heading: “Congressionally Directed Energy Efficiency and Renewable Energy Projects.” The CDS included $\$$4,000,000 of direct funding, with required match funds, to move the project forward. Alaska’s North Slope holds America’s largest proven and conventional natural gas supply. The integrated Alaska LNG Project will deliver 3.5 billion cubic feet of natural gas per day from Alaska’s North Slope gas fields to Alaskans as well as to a marine terminal located at tidewater in Cook Inlet. Alaska LNG is an integrated gas infrastructure project with three major components: a gas treatment plant (GTP) located at Prudhoe Bay, an 807-mile (1,287 km) gas pipeline (Mainline Pipeline) to Southcentral Alaska with interconnections for in-state gas use, and a natural gas liquefaction facility (LNG Facility) in Nikiski, Alaska. The integrated Alaska LNG Project has several strategic advantages including proven gas resources, existing upstream infrastructure, an advantageous arctic climate for LNG production, proximity to LNG markets, a track record of reliability from a state that first began exporting LNG to Japan in 1969, and broad support from Alaskans. North Slope natural gas is a conventional resource and can be produced with minimal drilling at a fraction of the carbon dioxide emissions of shale gas from the Lower 48 states. Through the development of the Alaska LNG Project, Alaska can provide energy security to Alaskans and a stable source of LNG to the Asia-Pacific region for generations. The Alaska LNG Project has been progressed through Pre-Front-End Engineering Design (Pre-FEED) and has obtained all major federal and State of Alaska permits and authorizations to construct the project, including the Federal Energy Regulatory Commission (FERC) Order Granting Authorization Under Section 3 of the Natural Gas Act. On September 5, 2024, the U.S. Department of Energy (DOE), National Energy Technology Laboratory (NETL) awarded Project No. DE-FE0032307 to AGDC with the objective to progress the project to Front-End Engineering Design (FEED) entry for the Alaska LNG Project Phase 1 Pipeline. The award Start Date was made effective July 1, 2023, with a Period of Performance through June 30, 2025. On March 27, 2025, AGDC announced the execution of definitive commercial agreements with Glenfarne Alaska LNG, LLC, an affiliate of Glenfarne Group, LLC, (together as “Glenfarne”), to lead the development of the Alaska LNG Project and enter FEED for the Phase 1 Pipeline. Project activities are now funded and directed by this private sector partner who holds a 75% interest in 8 Star Alaska, LLC (8 Star). 8 Star holds the assets of the Alaska LNG Project. As planned, AGDC continues to hold 25% minority interest in 8 Star and will play a governance role moving forward with Alaska LNG. This definitive commercial agreement milestone led to the successful completion of AGDC’s Statement of Project Objectives (SOPO) for FEED entry and led to the completion of DOE Project No. DE-FE0032307. At conclusion of the SOPO, AGDC also reached the award’s maximum federal cost share of $\$$4,000,000. AGDC is, therefore, providing Final Technical Report to close out DOE Project No. DE-FE0032307.

02 PETROLEUM↗

Vitrification Tests with Potential Technetium Capture Streams

About 50 million gallons of high-level waste is currently stored in underground tanks at The United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in an engineered facility on the Hanford site while the IHLW product is designed for acceptance at a national deep geological disposal facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements with respect to protection of the environment before they can be accepted for disposal. The Low Activity Waste (LAW) and High-Level Waste (HLW) at Hanford will be vitrified in Joule Heated Ceramic Melters (JHCMs) to produce stable products for disposal. Technetium is an important radioactive component in the Hanford tank waste and is typically one of the principal contributors to risk in performance assessments for the ILAW disposal facility. Technetium is also one of the more volatile radionuclides and the retention of technetium in the glass under the high temperature conditions prevailing during vitrification can vary over a relatively wide range depending on the feed composition, feed chemistry, and melter operating parameters. In support of the WTP Project, the Vitreous State Laboratory (VSL) at The Catholic University of America (CUA) and EnergySolutions have developed and tested glass formulations for WTP waste envelopes to provide data to meet the WTP contract requirements and to support system design activities. That work is based upon small-scale batch melts (“crucible melts”) using waste simulants. Glass compositions suitable for processing the tank waste streams for the WTP have been identified and tested for processing and product quality requirements at various scales, ranging from crucible melts of a few grams, up to the LAW Pilot Melter at processing rates in excess of 6600 kg/day (2000 kg/m 2 /day). Recent testing performed at VSL for Washington River Protection Solutions, LLC (WRPS) has investigated the baseline “single-pass” retention of technetium over the range of WTP LAW feed compositions and glass formulations as well as the development of potential modifications to the baseline that could increase the single-pass retention. For the WTP melter systems, the liquid waste streams from the primary off-gas system components are recycled back to the pretreatment facility and, ultimately, to subsequent melter feed batches. Such a recycle loop can greatly increase the overall retention of volatile constituents in the glass product over the single-pass value. Accordingly, more recent testing at VSL has been conducted on a melter system that incorporates a recycle flow sheet. The results from that work have provided important performance data for the unit operations in the primary off-gas system with respect to technetium capture and recycle, which is crucial in assessing the amount of technetium that ultimately reports to non-glass waste forms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Vitrification of inorganic ion exchange media

The primary objective of these tests outlined in the Test Plan for this work [15] and described herein was to demonstrate the vitrification of ion exchange media for cesium removal, either alone or in combination with a representative Hanford HLW stream. This included one formulation with chabazite as the only waste component and two formulations containing direct-feed fully washed AY-102 HLW solids combined with either CST or chabazite. Feed processing characteristics, glass production rate, melter emissions, and feed carryover were determined for each of the three feed compositions. This was accomplished through VGF and DM100 melter system testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Superstructure Optimization for Brine Valorization from Brackish Water Desalination

This poster presents preliminary results from a superstructure optimization framework developed to identify cost-optimal brine valorization configurations for brackish water desalination plants across diverse U.S. regional feed chemistries. The study uses brackish groundwater compositions from Arizona, California, Florida, New Mexico, and Texas. Using Pyomo Generalized Disjunctive Programming (GDP) within the WaterTAP modeling environment, the optimization framework simultaneously evaluates thousands of candidate treatment configurations, spanning nanofiltration, reverse osmosis, and chemical precipitation, to minimize the levelized cost of water (LCOW) while meeting water recovery targets and product recovery constraints. Results across eight representative feed clusters demonstrate water recovery rates of 57–87% and net LCOW values ranging from -$0.032/m³ (net revenue-positive) to $0.80/m. Notably, no single process configuration was optimal across all feed types, underscoring the necessity of feed-specific optimization. Products targeted include calcium carbonate (CaCO₃) at $0.01/kg and sodium chloride (NaCl) at $0.10/kg, both at 95% purity, with product revenues offsetting treatment costs in several scenarios. The work advances NAWI's process systems engineering capabilities for multi-configuration screening.

58 GEOSCIENCES↗

WASTE SOLIDIFICATION BUILDING BENCH SCALE HIGH ACTIVITY WASTE SIMULANT VARIABILITY STUDY FY2008

The primary objective of this task was to perform a variability study of the high activity waste (HAW) acidic feed to determine the impact of feed variability on the quality of the final grout and on the mixability of the salt solution into the dry powders. The HAW acidic feeds were processed through the neutralization/pH process, targeting a final pH of 12. These fluids were then blended with the dry materials to make the final waste forms. A secondary objective was to determine if elemental substitution for cost prohibitive or toxic elements in the simulant affects the mixing response, thus providing a more economical simulant for use in full scale tests. Though not an objective, the HAW simulant used in the full scale tests was also tested and compared to the results from this task. A statistically designed test matrix was developed based on the maximum molarity inputs used to make the acidic solutions. The maximum molarity inputs were: 7.39 HNO{sub 3}, 0.11618 gallium, 0.5423 silver, and 1.1032 'other' metals based on their NO{sub 3}{sup -} contribution. Substitution of the elements aluminum for gallium and copper for silver was also considered in this test matrix, resulting in a total of 40 tests. During the NaOH addition, the neutralization/pH adjustment process was controlled to a maximum temperature of 60 C. The neutralized/pH adjusted simulants were blended with Portland cement and zircon flour at a water to cement mass ratio of 0.30. The mass ratio of zircon flour to Portland cement was 1/12. The grout was made using a Hobart N-50 mixer running at low speed for two minutes to incorporate and properly wet the dry solids with liquid and at medium speed for five minutes for mixing. The resulting fresh grout was measured for three consecutive yield stress measurements. The cured grout was measured for set, bleed, and density. Given the conditions of preparing the grout in this task, all of the grouts were visually well mixed prior to preparing the grouts for measurements. All of the cured grouts were measured for bleed and set. All of the cured grouts satisfied the bleed and set requirements, where no bleed water was observed on any of the grout samples after one day and all had set within 3 days of curing. This data indicates, for a well mixed product, bleed and set requirement are satisfied for the range of acidic feeds tested in this task. The yield stress measurements provide both an indication on the mixability of the salt solution with dry materials and an indication of how quickly the grout is starting to form structure. The inability to properly mix these two streams into a well mixed grout product will lead to a non-homogeneous mixture that will impact product quality. Product quality issues could be unmixed regions of dry material and hot spots having high concentrations of americium 241. Mixes that were more difficult to incorporate typically resulted in grouts with higher yield stresses. The mixability from these tests will provide Waste Solidification Building (WSB) an indication of which grouts will be more challenging to mix. The first yield stress measurements were statistically compared to a list of variables, specifically the batched chemicals used to make the acidic solutions. The first yield stress was also compared to the physical properties of the acidic solutions, physical and pH properties of the neutralized/pH adjusted solutions, and chemical and physical properties of the grout.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calculation of Ground State Rotational Populations for Kinetic Gas Homonuclear Diatomic Molecules including Electron-Impact Excitation and Wall Collisions

A model has been developed to calculate the ground-state rotational populations of homonuclear diatomic molecules in kinetic gases, including the effects of electron-impact excitation, wall collisions, and gas feed rate. The equations are exact within the accuracy of the cross sections used and of the assumed equilibrating effect of wall collisions. It is found that the inflow of feed gas and equilibrating wall collisions can significantly affect the rotational distribution in competition with non-equilibrating electron-impact effects. The resulting steady-state rotational distributions are generally Boltzmann for N≥3, with a rotational temperature between the wall and feed gas temperatures. The N=0,1,2 rotational level populations depend sensitively on the relative rates of electron-impact excitation versus wall collision and gas feed rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗