Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

New Measurement of the {pi}{sup 0} Radiative Decay Width

High precision measurements of the differential cross sections for {pi}{sup 0} photoproduction at forward angles for two nuclei, {sup 12}C and {sup 208}Pb, have been performed for incident photon energies of 4.9-5.5 GeV to extract the {pi}{sup 0}{yields}{gamma}{gamma} decay width. The experiment was done at Jefferson Lab using the Hall B photon tagger and a high-resolution multichannel calorimeter. The {pi}{sup 0}{yields}{gamma}{gamma} decay width was extracted by fitting the measured cross sections using recently updated theoretical models for the process. The resulting value for the decay width is {Gamma}({pi}{sup 0}{yields}{gamma}{gamma})=7.82{+-}0.14(stat){+-}0.17(syst) eV. With the 2.8% total uncertainty, this result is a factor of 2.5 more precise than the current Particle Data Group average of this fundamental quantity, and it is consistent with current theoretical predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extraterrestrial intelligence - An observational approach

The article surveys present and proposed search techniques for extraterrestrial intelligence in terms of technological requirements. It is proposed that computer systems used along with existing antennas may be utilized to search for radio signals over a broad frequency range. A general search within the electromagnetic spectrum would explore frequency, received power flux, spatial locations, and modulation. Previous SETI projects (beginning in 1960) are briefly described. An observation project is proposed in which the earth's rotational motion would scan the antenna beam along one declination circle in 24 hours. The 15 degree beam width would yield a mapping of 75% of the sky in an 8-day period if the beam were shifted 15 degrees per day. With the proposed instrument parameters, a sensitivity of about 10 to the -21 watt/sq m is achieved at a 0 degree declination and 1.5 GHz. In a second phase, a 26 m antenna would yield an HPBW of 0.8 degrees at 1 GHz and 0.03 degrees at 25 GHz. It is noted that the described technology would provide secondary benefits for radio astronomy, radio communications, and other fields.

Murray, B.↗

Digital I and C system upgrade integration technique

This work developed an integration technique for digital I and C system upgrade, the utility can replace the I and C systems step by step systematically by this method. Inst. of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin-Shan (CS) NPP, Kuo-Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) Procedure. The digital I and C replacement integration technique includes: (I) Establishment of Nuclear Power Plant Digital Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR- 1011710 (2005) 'Handbook for Evaluating Critical Digital Equipment and Systems' which was published by the Electric Power Research Inst. (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SVandV), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of Watchdog Timer, Evaluation of Electromagnetic Compatibility (EMC), Evaluation of Grounding for System/Component, Seismic Evaluation, Witness and Inspection, Lessons Learnt from the Digital I and C Failure Events. A solid review can assure the quality of the digital I and C system replacement. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hard X-ray Phase-Contrast Tomographic Nanoimaging

Synchrotron-based full-field tomographic microscopy established itself as a tool for noninvasive investigations. Many beamlines worldwide routinely achieve micrometer spatial resolution while the isotropic 100-nm barrier is reached and trespassed only by few instruments, mainly in the soft x-ray regime. We present an x-ray, full-field microscope with tomographic capabilities operating at 10 keV and with a 3D isotropic resolution of 144 nm recently installed at the TOMCAT beamline of the Swiss Light Source. Custom optical components, including a beam-shaping condenser and phase-shifting dot arrays, were used to obtain an ideal, aperture-matched sample illumination and very sensitive phase-contrast imaging. The instrument has been successfully used for the nondestructive, volumetric investigation of single, unstained cells.

43 PARTICLE ACCELERATORS↗

Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclay

One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

43 PARTICLE ACCELERATORS↗

Note: Enhanced production of He{sup +} from the Versatile Ion Source (VIS) in off-resonance configuration

The Versatile Ion Source (VIS) is a microwave discharge ion source installed at INFN-LNS and here used as test-bench for the production of high intensity low emittance proton beams and for studies on plasma physics. A series of measurements have been carried out with VIS in order to test the source with light ions. In particular a He{sup +} beam has been characterized in terms of plasma discharge parameters. The experiment has been triggered by the observation of X-radiation emission from the plasma for some configuration of the magnetic field profile. The plasma electron energy distribution function is in fact modified when in some regions of the plasma chamber under-resonance discharge takes place, fulfilling the condition that allows the electromagnetic wave to electrostatic wave conversion. These tests allowed obtaining more than 50 mA of He{sup +} beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optomechanical design of a prompt gamma reaction history diagnostic

The National Ignition Facility and the Omega Laser Facility both have a need for measuring prompt gamma radiation as part of a nuclear diagnostic program. A new gamma-detection diagnostic using off-axis-parabolic mirrors has been built. Some new techniques were used in the design, construction, and tolerancing of this gamma ray diagnostic. Because of the wavelength requirement (250 to 700 nm), the optical element surface finishes were a key design consideration. The optical enclosure had to satisfy pressure safety concerns and shielding against electromagnetic interference induced by gammas and neutrons. Structural finite element analysis was needed to meet rigorous optical and safety requirements. The optomechanical design is presented. Alignment issues are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EMR Measurements on NDA Equipment

Electromagnetic radiation (EMR) emission strength measurements were performed on a suite of passive non-destructive assay (NDA) radiation detection equipment. Data were collected from 9 kHz up to 6 GHz on each of the assembled systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature limited heater with a conduit substantially electrically isolated from the formation

A system for heating a hydrocarbon containing formation is described. A conduit may be located in an opening in the formation. The conduit includes ferromagnetic material. An electrical conductor is positioned inside the conduit, and is electrically coupled to the conduit at or near an end portion of the conduit so that the electrical conductor and the conduit are electrically coupled in series. Electrical current flows in the electrical conductor in a substantially opposite direction to electrical current flow in the conduit during application of electrical current to the system. The flow of electrons is substantially confined to the inside of the conduit by the electromagnetic field generated from electrical current flow in the electrical conductor so that the outside surface of the conduit is at or near substantially zero potential at 25.degree. C. The conduit may generate heat and heat the formation during application of electrical current.

47 OTHER INSTRUMENTATION↗

Detector Noise Susceptibility Issues for the Future Generation of High Energy Physics Experiments

The front-end electronics (FEE) noise characterization to electromagnetic interference and the compatibility of the different subsystems are important topics to consider for the LHC calorimeter upgrades. A new power distribution scheme based on switching power converters is under study and will define a noticeable noise source very close to the detector's FEE. Knowledge and experience with both FFE noise and electromagnetic compatibility (EMC) issues from previous detectors are important conditions to guarantee the design goals and the good functionality of the upgraded LHC detectors. This paper shows an overview of the noise susceptibility studies performed in different CMS subdetectors. The impact of different FEE topologies in the final sensitivity to electromagnetic interference of the subsystem is analyzed and design recommendations are presented to increase the EMC of the detectors to the future challenging power distribution topologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cyber Attack Resilient HVDC System (CARDS) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE-OE funded project DE-OE0000824, where ABB Inc. (ABB), in collaboration with University of Illinois at Urbana-Champaign (UIUC), Bonneville Power Administration (BPA), Argonne National Laboratories (ANL), and University of Idaho (UI) pursued the development of a system of defense for High Voltage Direct Current transmission systems against cyber-attacks (CARDS). An HVDC substation with CARDS features will be more capable of mitigating cyber-attacks especially those that seek to control or interrupt the power flow in the HVDC line. It empowers existing HVDC intelligent electronic devices to collaborate in identifying and blocking malicious intents to trip HVDC AC circuit breakers, block thyristor valves, misconfigure devices settings, even though the commands and the measurements comply with correct syntax. The CARDS functions utilize the physics of electromagnetic AC and DC systems, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected HVDC substation devices. With the aim of advancing the state of the art, the team proceeded to develop a demonstrable system against cyber-attacks in an HVDC substation environment, via functional upgrades to existing firmware of commercial off-the-shelf HVDC station devices, and/or embedded hardware, without the need for additional instrumentation nor new instrumentation technologies. It is to ensure that the solutions resulting from the project will support the HVDC devices currently installed in the US electricity delivery infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Plasma wave observations with the Dynamics Explorer 1 spacecraft

This paper reviews the results from the plasma wave instrument on the Dynamics Explorer 1 (DE-1) spacecraft. The DE-1 spacecraft was launched on August 3, 1981, into an elliptical polar orbit with initial perigee and apogee radial distances of 1.09 and 4.65 earth radii. In the roughly six years since the launch of the spacecraft, DE-1 has provided basic new information on a wide variety of magnetospheric plasma wave phenomena. These include auroral kilometric radiation, auroral hiss, Z mode radiation, narrow-band electromagnetic emissions associated with equatorial upper hybrid waves, whistler mode emissions, wave-particle interactions stimulated by ground VLF transmitters, equatorial ion-cyclotron emissions, ion Bernstein-mode emissions, and electric field turbulence along the auroral field lines. A brief review of the basic plasma wave modes that can exist in the equatorial and polar regions of the magnetosphere is first given. After the basic terminology is established, each of the above areas of plasma wave research is discussed in detail, first by reviewing the state of knowledge at the time of the DE-1 launch, and then by describing the contribution made by DE-1 in the six years since the spacecraft was launched.

Gurnett, D. A.↗

Time-Domain Astronomy with the Fermi GBM

The Fermi Gamma-ray Burst Monitor (GBM) is an all-sky monitoring instrument sensitive to energies from 8 keV to 40 MeV. Over the past 8 years of operation, the GBM has detected over 240 gamma-ray bursts per year and provided timely GCN notices with localization to few-degree accuracy for follow-up observations. In addition to GRBs, Galactic transients, solar flares, and terrestrial gamma-ray flashes have also been observed. In recent years we have also been searching the continuous GBM data for electromagnetic counterpart to astrophysical neutrinos and gravitational wave events, as these are believed to be associated with gamma-ray bursts. With continuous data downlink every few hours and a temporal resolution of 2 microseconds, GBM is well suited for observing transients and supporting EM follow-up in the era of multi-messenger astronomy.

gamma-ray burst↗

Single Drop Cytometry Onboard the International Space Station

Real-time lab analysis is needed to support clinical decision making and research on human missions to the Moon and Mars. Powerful laboratory instruments, such as flow cytometers, are generally too cumbersome for spaceflight. Here, we show that scant test samples can be measured in microgravity, by a trained astronaut, using a miniature cytometry-based analyzer, the rHEALTH ONE, modified specifically for spaceflight. The base device addresses critical spaceflight requirements including minimal resource utilization and alignment-free optics for surviving rocket launch. To fully enable reduced gravity operation onboard the space station, we incorporated bubble-free fluidics, electromagnetic shielding, and gravity-independent sample introduction. We show microvolume flow cytometry from 10 μL sample drops, with data from five simultaneous channels using 10 μs bin intervals during each sample run, yielding an average of 72 million raw data points in approximately 2 minutes. We demonstrate the device measures each test sample repeatably, including correct identification of a sample that degraded in transit to the International Space Station. This approach can be utilized to further our understanding of spaceflight biology and provide immediate, actionable diagnostic information for management of astronaut health without the need for Earth-dependent analysis.

Daniel J. Rea↗

Enhancement of EM Pump Performance through Modeling and Testing

Liquid sodium has seen development as a nuclear reactor coolant in the United States for over 50 years. While sodium has many desirable characteristics as a heat transfer fluid, its reactivity poses numerous engineering challenges for even the most basic plant components like pumps. Despite the challenges, mechanical pumps have seen success in sodium service albeit at the expense of simplicity and flexibility. In fact, significant failures of these pumps have been recorded which can be attributed to their complexity. Notwithstanding the complexity, mechanical pumps are still widely proposed for the main circuit pump of sodium cooled reactors. However, an alternative to mechanical pumps are Electromagnetic Induction Pumps (EMIPs) which use the principle of the Lorentz Force. EMIPs avoid mechanically moving parts in contact with sodium which simplifies the design by avoiding mechanical wear and seals. Therefore, these pumps are generally safer and more reliable than their mechanical counterparts. That being said, EMIPs suffer from relatively low efficiencies that range from 5% to 45%. Some of the inefficiencies are inherent to the EMIPs pumps; namely, inefficiencies arise in the form of resistive heating losses in the fluid itself. However, other inefficiencies arise from Edge Effects which include Finite Length and Finite Width effects. Due to the significant safety advantages EMIPs have compared to mechanical pumps, there is a strong motivation to integrate these technologies into the design of Generation IV liquid-metal-cooled nuclear power plants. However, EMIPs have low efficiencies partly attributed to Edge Effects. Much of the literature focusing on Edge Effects is dated or simply does not exist in the public domain. More recently, numerical models of EMIPs have shown promising results. However, these models are often custom solvers or use complex software suits which limit their application. This report describes the work completed to understand Edge Effects in two EMIPs designs. These designs are the Annular Linear Induction Pump (ALIP) and Permanent Magnet Induction Pump (PMIP) also known as a Moving Magnet Pump (MMP). The methodology developed during this project aim at measuring key performance parameters (pressure-flowrate and efficiency-slip performance) using high temperature liquid-sodium. Baseline experimental measurements were then used to verify the accuracy of numerical models developed in the software suit ANSYS/FLUENT. On the experimental side, instrumentation was developed to characterize the pressure-flowrate and efficiency-slip performance of both the ALIP and PMIP in high-temperature liquid-sodium. Additionally, instrumentation was developed to measure potential output pressure pulsations and the magnetic field distributions. Moreover, a specialized ALIP was constructed to study the impacts magnetic field tapering, also known as coil grading, on the Finite Length Effect. Lastly, experimental performance curves of the PMIP were collected at 300 oC and 600 oC and compared to analytical theory which accounted for Finite Width Effects. These results showed that the Finite Width Effect and non-uniform magnetic field in a PMIP impact the performance. On the numerical side, models were developed using the software suit FLUENT/ANSYS. These methods were initially compared against a simple MHD flow in a Permanent Magnet Electromagnet Flowmeter (PMEMFM). The results were significant in that they showed agreeance between the numerical model and demonstrated that PMEMFM’s could be calibrated numerically. These modeling methods were then applied to a prototypic PMIP. Results showed that this simple model provided reasonably accurate results of the PMIP p-Q performance.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The SciBooNE Data Acquisition System

SciBooNE started in June 2007 primarily to study neutrino and anti-neutrino interactions in the energy region below 1 GeV. The SciBooNE detector is located in Booster Neutrino Beamline at Fermi National Accelerator Laboratory. The SciBooNE data aquisition system consists of the readout software and an event builder, which collects data from each detector component (SciBar detector, an electromagnetic calorimeter, Muon Range Detector and GPS). The typical DAQ readout time per trigger is 20 ms, which is fast enough to take every beam spill. The system is also very stable and the probability of missing a beam spill due to the readout time is less than 0.002 %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Geant4 physics models using collision data from the LHC

CMS experiment has designed a strategy to validate GEANT4 physics models using collision data from the Large Hadron Collider. Isolated charged particles are measured simultaneously in the tracker as well as in the calorimeters. These events are selected using dedicated triggers and are used to measure the response in the calorimeter. Measurements of mean response, resolution, energy sharing between the electromagnetic and hadron calorimeters, shower shapes are directly compared with predictions from the Monte Carlo. Single particle response is also used in calibrating the calorimeters and in improving jet energy measurements. GEANT4 physics models are also used to understand the source of anomalous high energy deposits in the calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt fission neutron spectra from fission induced by 1 to 8 MeV neutrons on {sup 235}U and {sup 239}Pu using the double time-of-flight technique

Prompt fission neutron spectra from {sup 235}U and {sup 239}Pu were measured for incident neutron energies from 1 to 200 MeV at the Weapons Neutron Research facility (WNR) of the Los Alamos Neutron Science Center, and the experimental data were analyzed with the Los Alamos model for the incident neutron energies of 1-8 MeV. A CEA multiple-foil fission chamber containing deposits of 100 mg {sup 235}U and 90 mg {sup 239}Pu detected fission events. Outgoing neutrons were detected by the Fast Neutron-Induced {gamma}-Ray Observer array of 20 liquid organic scintillators. A double time-of-flight technique was used to deduce the neutron incident energies from the spallation target and the outgoing energies from the fission chamber. These data were used for testing the Los Alamos model, and the total kinetic energy parameters were optimized to obtain a best fit to the data. The prompt fission neutron spectra were also compared with the Evaluated Nuclear Data File (ENDF/B-VII.0). We calculate average energies from both experimental and calculated fission neutron spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗