Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Measurements of LET distribution and dose equivalent onboard the Space Shuttle IML-2 (STS-65) and S/MM#4 (STS-79)

Space radiation dosimetry measurements have been made onboard the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2: 28.5 degrees x 300 km: 14.68 days) and the STS-79 in the 4th Shuttle MIR mission (S/MM#4: 51.6 degrees x 300-400km: 10.2 days). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD-I for IML-2 and RRMD-II with improved triggering system for S/MM#4)" utilizing silicon semi-conductor detectors and the other detectors are conventional passive detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. The main contribution to dose equivalent for particles with LET > 5.0 keV/micrometer (IML-2) and LET > 3.5 keV/micrometer (S/MM#4) is seen to be due to galactic cosmic rays (GCRs) and the contribution of the South Atlantic Anomaly (SAA) is less than 5% (IML-2: 28.5 degrees x 300 km) and 15% (S/MM#4: 51.6 degrees x 400 km) in the above RRMD LET detection conditions. For the whole LET range (> 0.2 kev/micrometer) obtained by TLDs and CR-39 in these two typical orbits (a small inclination x low altitude and a large inclination x high altitude), absorbed dose rates range from 94 to 114 microGy/day, dose equivalent rates from 186 to 207 microSv/day and average quality factors from 1.82 to 2.00 depending on the locations and directions of detectors inside the Spacelab at the highly protected IML-2 orbit (28.5 degrees x 300 km), and also, absorbed dose rates range from 290 to 367 microGy/day, dose equivalent rates from 582 to 651 microSv/day and average quality factors from 1.78 to 2.01 depending on the dosimeter packages around the RRMD-II "Detector Unit" at the S/MM#4 orbit (5l.6 degrees x 400km). In general, it is seen that absorbed doses depend on the orbit altitude (SAA trapped particles contribution dominant) and dose equivalents on the orbit inclination (GCR contribution dominant). The LET distributions obtained by two different types of active and passive detectors, RRMDs and CR-39, are in good agreement for LET of 15 - 200 kev/micrometer and difference of these distributions in the regions of LET < 15 kev/micrometer and LET > 200 kev/micrometer can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks and chemical etching conditions.

manned↗

Calcium kinetics with microgram stable isotope doses and saliva sampling

Studies of calcium kinetics require administration of tracer doses of calcium and subsequent repeated sampling of biological fluids. This study was designed to develop techniques that would allow estimation of calcium kinetics by using small (micrograms) doses of isotopes instead of the more common large (mg) doses to minimize tracer perturbation of the system and reduce cost, and to explore the use of saliva sampling as an alternative to blood sampling. Subjects received an oral dose (133 micrograms) of 43Ca and an i.v. dose (7.7 micrograms) of 46Ca. Isotopic enrichment in blood, urine, saliva and feces was well above thermal ionization mass spectrometry measurement precision up to 170 h after dosing. Fractional calcium absorptions determined from isotopic ratios in blood, urine and saliva were similar. Compartmental modeling revealed that kinetic parameters determined from serum or saliva data were similar, decreasing the necessity for blood samples. It is concluded from these results that calcium kinetics can be assessed with micrograms doses of stable isotopes, thereby reducing tracer costs and with saliva samples, thereby reducing the amount of blood needed.

Clinical Trial↗

Space Radiation Organ Doses for Astronauts on Past and Future Missions

We review methods and data used for determining astronaut organ dose equivalents on past space missions including Apollo, Skylab, Space Shuttle, NASA-Mir, and International Space Station (ISS). Expectations for future lunar missions are also described. Physical measurements of space radiation include the absorbed dose, dose equivalent, and linear energy transfer (LET) spectra, or a related quantity, the lineal energy (y) spectra that is measured by a tissue equivalent proportional counter (TEPC). These data are used in conjunction with space radiation transport models to project organ specific doses used in cancer and other risk projection models. Biodosimetry data from Mir, STS, and ISS missions provide an alternative estimate of organ dose equivalents based on chromosome aberrations. The physical environments inside spacecraft are currently well understood with errors in organ dose projections estimated as less than plus or minus 15%, however understanding the biological risks from space radiation remains a difficult problem because of the many radiation types including protons, heavy ions, and secondary neutrons for which there are no human data to estimate risks. The accuracy of projections of organ dose equivalents described here must be supplemented with research on the health risks of space exposure to properly assess crew safety for exploration missions.

Cucinotta, Francis A.↗

Calculation of Dose Deposition in 3D Voxels by Heavy Ions and Simulation of gamma-H2AX Experiments

The biological response to high-LET radiation is different from low-LET radiation due to several factors, notably difference in energy deposition and formation of radiolytic species. Of particular importance in radiobiology is the formation of double-strand breaks (DSB), which can be detected by -H2AX foci experiments. These experiments has revealed important differences in the spatial distribution of DSB induced by low- and high-LET radiations [1,2]. To simulate -H2AX experiments, models based on amorphous track with radial dose are often combined with random walk chromosome models [3,4]. In this work, a new approach using the Monte-Carlo track structure code RITRACKS [5] and chromosome models have been used to simulate DSB formation. At first, RITRACKS have been used to simulate the irradiation of a cubic volume of 5 m by 1) 450 1H+ ions of 300 MeV (LET 0.3 keV/ m) and 2) by 1 56Fe26+ ion of 1 GeV/amu (LET 150 keV/ m). All energy deposition events are recorded to calculate dose in voxels of 20 m. The dose voxels are distributed randomly and scattered uniformly within the volume irradiated by low-LET radiation. Many differences are found in the spatial distribution of dose voxels for the 56Fe26+ ion. The track structure can be distinguished, and voxels with very high dose are found in the region corresponding to the track "core". These high-dose voxels are not found in the low-LET irradiation simulation and indicate clustered energy deposition, which may be responsible for complex DSB. In the second step, assuming that DSB will be found only in voxels where energy is deposited by the radiation, the intersection points between voxels with dose > 0 and simulated chromosomes were obtained. The spatial distribution of the intersection points is similar to -H2AX foci experiments. These preliminary results suggest that combining stochastic track structure and chromosome models could be a good approach to understand radiation-induced DSB and chromosome aberrations.

Plante, I.↗

Automation of PCXMC and ImPACT for NASA Astronaut Medical Imaging Dose and Risk Tracking

To automate astronaut organ and effective dose calculations from occupational X-ray and computed tomography (CT) examinations incorporating PCXMC and ImPACT tools and to estimate the associated lifetime cancer risk per the National Council on Radiation Protection & Measurements (NCRP) using MATLAB(R). Methods: NASA follows guidance from the NCRP on its operational radiation safety program for astronauts. NCRP Report 142 recommends that astronauts be informed of the cancer risks from reported exposures to ionizing radiation from medical imaging. MATLAB(R) code was written to retrieve exam parameters for medical imaging procedures from a NASA database, calculate associated dose and risk, and return results to the database, using the Microsoft .NET Framework. This code interfaces with the PCXMC executable and emulates the ImPACT Excel spreadsheet to calculate organ doses from X-rays and CTs, respectively, eliminating the need to utilize the PCXMC graphical user interface (except for a few special cases) and the ImPACT spreadsheet. Results: Using MATLAB(R) code to interface with PCXMC and replicate ImPACT dose calculation allowed for rapid evaluation of multiple medical imaging exams. The user inputs the exam parameter data into the database and runs the code. Based on the imaging modality and input parameters, the organ doses are calculated. Output files are created for record, and organ doses, effective dose, and cancer risks associated with each exam are written to the database. Annual and post-flight exposure reports, which are used by the flight surgeon to brief the astronaut, are generated from the database. Conclusions: Automating PCXMC and ImPACT for evaluation of NASA astronaut medical imaging radiation procedures allowed for a traceable and rapid method for tracking projected cancer risks associated with over 12,000 exposures. This code will be used to evaluate future medical radiation exposures, and can easily be modified to accommodate changes to the risk calculation procedure.

Bahadori, Amir↗

Dose Calibration of the ISS-RAD Fast Neutron Detector

The ISS-RAD instrument has been fabricated by Southwest Research Institute and delivered to NASA for flight to the ISS in late 2015 or early 2016. ISS-RAD is essentially two instruments that share a common interface to ISS. The two instruments are the Charged Particle Detector (CPD), which is very similar to the MSL-RAD detector on Mars, and the Fast Neutron Detector (FND), which is a boron-loaded plastic scintillator with readout optimized for the 0.5 to 10 MeV energy range. As the FND is completely new, it has been necessary to develop methodology to allow it to be used to measure the neutron dose and dose equivalent. This talk will focus on the methods developed and their implementation using calibration data obtained in quasi-monoenergetic (QMN) neutron fields at the PTB facility in Braunschweig, Germany. The QMN data allow us to determine an approximate response function, from which we estimate dose and dose equivalent contributions per detected neutron as a function of the pulse height. We refer to these as the "pSv per count" curves for dose equivalent and the "pGy per count" curves for dose. The FND is required to provide a dose equivalent measurement with an accuracy of 10% of the known value in a calibrated AmBe field. Four variants of the analysis method were developed, corresponding to two different approximations of the pSv per count curve, and two different implementations, one for real-time analysis onboard ISS and one for ground analysis. We will show that the preferred method, when applied in either real-time or ground analysis, yields good accuracy for the AmBe field. We find that the real-time algorithm is more susceptible to chance-coincidence background than is the algorithm used in ground analysis, so that the best estimates will come from the latter.

Zeitlin, C.↗

Dose- and Ion-Dependent Effects in the Oxidative Stress Response to Space-Like Radiation Exposure in the Skeletal System

Exposure to space radiation may pose a risk to skeletal health during subsequent aging. Irradiation acutely stimulates bone remodeling in mice, although the long-term influence of space radiation on bone-forming potential (osteoblastogenesis) and possible adaptive mechanisms are not well understood. We hypothesized exposure to ionizing radiation impairs osteoblastogenesis in an ion-type specific manner, with low doses capable of modulating expression of redox-related genes. 16-week old, male, C57BL6/J mice were exposed to low linear-energy-transfer (LET) protons (150 mega electron volts per nucleon) or high-LET (sup 56) Fe ions (600 mega electron volts per nucleon) using either low (5 or 10 centigrays) or high (50 or 200 centigrays) doses at NASAs Space Radiation Lab at Brookhaven National Lab (NSRL/BNL). Tissues were harvested 5 weeks or 1 year after irradiation and bones were analyzed by microcomputed tomography for cancellous microarchitecture and cortical geometry. Marrow-derived, adherent cells were grown under osteoblastogenic culture conditions. Cell lysates were analyzed for select groups by RT-PCR (Reverse Transcription-Polymerase Chain Reaction) during the proliferative phase or the mineralizing phase, and differentiation was analyzed by imaging mineralized nodules (percentage surface area). Representative genes were selected for expression analyses, including cell proliferation (PCNA, Cdk2, p21, p53), differentiation (Runx2, Alpl, Bglap), oxidative metabolism (Catalase, GPX, MnSOD, CuZnSOD, iNos, Foxo1), DNA-damage repair (Gadd45), or apoptosis (Caspase 3). As expected, a high dose (200 centigrays), but not low doses, of either (sup 56) Fe or protons caused a loss of cancellous bone volume per total volume. Marrow cells produced mineralized nodules ex vivo regardless of radiation type or dose; (sup 56) Fe (200 centigrays) inhibited median nodule area by more than 90 percent at 5 weeks and 1 year post-irradiation, compared to controls. At 5 weeks post exposure, irradiation with protons or (sup 56) Fe caused few changes in gene expression levels during osteoblastogenesis, although a high dose of (sup 56) Fe (200 centigrays) increased levels of Catalase and Gadd45. In addition, supplementing cell culture media with SOD protected marrow-derived osteoprogenitors from the damaging effects of exposure to low-LET ((sup 137) Cs gamma) if irradiated in vitro, but had limited protective effects on high-LET (sup 56) Fe-exposed cells. In sum, exposure of mice to either protons or (sup 56) Fe at a relatively high dose (200 cGy) caused persistent bone loss, whereas only high-LET (sup 56) Fe increased expression of redox-related genes and inhibited osteoblastogenesis, albeit to a limited extent. We conclude that high-LET irradiation impaired osteoblastogenesis and regulated steady-state gene expression of select redox-related genes during osteoblastogenesis, which may contribute to persistent bone loss.

ionizing radiation↗

Impairment of Human Ocular Tracking with Low-Dose Alcohol

Previous studies have documented adverse effects of alcohol on oculomotor performance. For example, moderate-dose alcohol (yielding a Blood Alcohol Concentration or BAC of 0.04-0.1%) has been shown to decrease steady-state pursuit gain (Fransson et al., 2010, Clin Neurophysiol, 121(12): 2134; Moser et al., 1998, J Neurol, 245(8): 542; Roche & King, 2010, Psychopharmacology, 212(1): 33), to increase saccade latency (Moser et al., 1998, J Neurol, 245(8): 542; Roche & King, 2010, Psychopharmacology, 212(1): 33), to decrease peak saccadic velocity (Fransson et al., 2010, Clin Neurophysiol, 121(12): 2134; Roche & King, 2010, Psychopharmacology, 212(1): 33), and to increase the frequency of catch-up saccades (Moser et al., 1998, J Neurol, 245(8): 542). Here, we administered two doses of ethanol on different days, yielding moderate (0.06%) and low (0.02%) levels of initial BAC, to examine the effects on human ocular tracking over BACs ranging from 0.00 to 0.07%. Twelve subjects (8 females) participated in a 5-day study. Three days of at-home measurements of daily activity and sleep were monitored, followed by two laboratory days where, ~5 hours after awakening, we administered one of the two possible single doses of alcohol. Using a previously published paradigm (Liston & Stone, 2014, J Vis, 14(14): 12), we measured oculomotor performance multiple times throughout the day with three pre-dosing baseline runs and bi-hourly post-dosing test runs until the subject recorded a BAC of 0.00% for two hours. BAC was measured before each run using an Alco-Sensor IV breathalyzer (Intoximeters, Inc., St. Louis, MO). For each of the oculometric measures, for each subject, we computed the within-subject % deviation for each test run from their baseline averaged across their three pre-dosing runs. We then averaged the data across subjects in 0.01% BAC bins. Finally, we used linear regression to compute the slope and x-intercept (threshold) of the mean binned % deviation as a function of BAC. We found that pursuit initiation was impaired at very low BAC levels, with significant (p < 0.002) linear trends in latency (+1.3%/0.01%BAC) and initial acceleration (-4.6%/0.01%BAC) with extrapolated absolute thresholds at or below 0.01% BAC. We also found that steady-state tracking was impaired showing significant (p < 0.002) linear trends in gain (- 3.8%/0.01%BAC) and catch-up saccade amplitude (+9.1%/0.01%BAC), again with extrapolated absolute thresholds around 0.01% BAC. We also found a significant (p < 0.02) increase in pursuit direction noise (+9.8%/0.01%BAC) with an extrapolated absolute threshold below 0.01% BAC. Many aspects of ocular tracking are impaired in a dose-dependent manner beginning at a BAC level around 0.01%, with significant effects at levels lower than previously reported and up to 8-times lower than the legal limit for driving in most states.

human performance↗

The Potential Outcome Model: Explaining Low-Dose Radiobiology through an Epidemiologic Lens

One of the major challenges in understanding space radiation-induced carcinogenesis is the uncertainty from translating radiobiological research in cellular and animal models to humans, especially at doses below 100 mSv. Biological studies have shown a host of potential outcomes at lowdoses in animal and cellular models. The existence of non-targeted effects as bystander and abscopal effects is well-documented from clinical research and basic science1,2,3. While some studies have shown increased effects at low doses, others have shown evidence of hormetic bystander effects, where radiation exposure may be beneficial4,5,6. Despite these varied and diverse findings, epidemiologic studies largely support the linear-no threshold (LNT) assumption used by radiation protection guidance7,8. Translational animal-to-human models have predominantly considered ratio values such as the relative biological effectiveness (RBE) and dose and dose-rate effectiveness factor (DDREF) that rely on the assumption of LNT rather than implementing specific dose-response shapes in the low-dose region, and translational cell-to-human models are uncommon. The sufficient component cause model presents an opportunity to examine biological findings at low doses from an epidemiological lens9. In this model, exposures “sufficient” to cause an outcome of interest are presented in pie charts, such that when all slices of a pie chart are fulfilled, the outcome will occur. Multiple pie charts may exist for a single outcome, illustrating individual differences9. In 1988,Greenland and Poole adapted the sufficient component cause model to incorporate interaction with other exposures (such as genetics or lifestyle factors)10. They show that a range of biological processes are possible in a population, but that an epidemiologic study will only reveal the mean outcome from the population at large10,11. Using this construct, the multiple outcomes presented in radiobiological models to date can be explained in the context of epidemiologic studies. This presentation aims to demonstrate a causal framework that can integrate radiobiological and epidemiological models to date. It is intended as a conversation starter to spur future research.

C M Milder↗

Effects of Low Dose Radiation and Radiation Countermeasures on Infection By Spaceflight Analogue Cultured Salmonella Using 3-D Biomimetic Human Tissue Models

While both microgravity and radiation are major biological stressors associated with the spaceflight environment, their cumulative impact on host-pathogen interactions and infectious disease risks are rarely considered. This is critical to address, since the cumulative effects of these stressors during spaceflight may result in unexpected negative impacts on crew health and performance that neither condition alone would predict, thus limiting the ability to develop effective countermeasures. Previously, we showed that both spaceflight and spaceflight analogue culture increased the virulence and pathogenesis-related characteristics of the foodborne pathogen, Salmonella Typhimurium (S. Typhimurium), which is responsible for disqualification of food destined for the International Space Station and Salmonella spp. have been found aboard NASA spacecraft. Recently, we demonstrated that spaceflight-analogue culture of S. Typhimurium increased its ability to infect 3-D biomimetic human intestinal tissue models. In a separate study, we showed low dose radiation damaged our 3-D intestinal models. The primary objective of this proposal is to evaluate the possibility that low dose radiation will exacerbate the already increased bacterial pathogenicity of S. Typhimurium observed following spaceflight analogue culture. In addition, we will determine the impact of a radiation countermeasure to provide protection against both radiation and pathogen-induced tissue damage and inflammation. Hypothesis: The already enhanced infection potential of spaceflight analogue cultured S. Typhimurium will be further exacerbated when used to infect host cells exposed to low dose radiation and this enhanced pathogenicity can be mitigated by a radioprotective compound. Aims: 1.Characterize the impact of spaceflight-analogue culture on the ability of S. Typhimurium to infect 3-D biomimetic intestinal tissue models before and after exposure to low dose radiation. 2. Evaluate the ability of the radioprotective compound, EC-18, to protect 3-D intestinal models from low dose radiation, S. Typhimurium infection, and the cumulative impact of these stressors. Significance: Current infectious disease risk assessments for spaceflight do not consider the potential for increased susceptibility to infection and disease resulting from exposure to low dose radiation, which is a critical consideration. This study will provide key evidence to determine if exposure to low dose radiation may be a factor in astronaut susceptibility to infection during long duration exploration missions and the impact of selected countermeasures to mitigate that risk to crew health. We have completed infection studies of the 3-D biomimetic intestinal tissue models and are currently analyzing the data.

Jennifer Barrila↗

Effects of Low Dose Radiation and Radiation Countermeasures on Infection By Spaceflight Analogue Cultured Salmonella Using 3-D Biometric Human Tissue Models

While both microgravity and radiation are major biological stressors associated with the spaceflight environment, their cumulative impact on host-pathogen interactions and infectious disease risks are rarely considered. This is critical to address, since the cumulative effects of these stressors during spaceflight may result in unexpected negative impacts on crew health and performance that neither condition alone would predict, thus limiting the ability to develop effective countermeasures. Previously, we showed that both spaceflight and spaceflight analogue culture increased the virulence and pathogenesis-related characteristics of the foodborne pathogen, Salmonella Typhimurium (S. Typhimurium), which is responsible for disqualification of food destined for the International Space Station and Salmonella spp. have been found aboard NASA spacecraft. Recently, we demonstrated that spaceflight-analogue culture of S. Typhimurium increased its ability to infect 3-D biomimetic human intestinal tissue models. In a separate study, we showed low dose radiation damaged our 3-D intestinal models. The primary objective of this proposal is to evaluate the possibility that low dose radiation will exacerbate the already increased bacterial pathogenicity of S. Typhimurium observed following spaceflight analogue culture. In addition, we will determine the impact of a radiation countermeasure to provide protection against both radiation and pathogen-induced tissue damage and inflammation. Hypothesis: The already enhanced infection potential of spaceflight analogue cultured S. Typhimurium will be further exacerbated when used to infect host cells exposed to low dose radiation and this enhanced pathogenicity can be mitigated by a radioprotective compound. Aims: 1. Characterize the impact of spaceflight-analogue culture on the ability of S. Typhimurium to infect 3-D biomimetic intestinal tissue models before and after exposure to low dose radiation. 2. Evaluate the ability of the radioprotective compound, EC-18, to protect 3-D intestinal models from low dose radiation, S. Typhimurium infection, and the cumulative impact of these stressors. Significance: Current infectious disease risk assessments for spaceflight do not consider the potential for increased susceptibility to infection and disease resulting from exposure to low dose radiation, which is a critical consideration. This study will provide key evidence to determine if exposure to low dose radiation may be a factor in astronaut susceptibility to infection during long duration exploration missions and the impact of selected countermeasures to mitigate that risk to crew health. This study has been initiated and data collection is beginning.

Jennifer Barrila↗

Effects of Low Dose Radiation and Radiation Countermeasures on Infection by Spaceflight Analogue Cultured Salmonella Using 3-D Biomimetic Human Tissue Models

While both microgravity and radiation are major biological stressors associated with the spaceflight environment, their cumulative impact on host-pathogen interactions and infectious disease risks are rarely considered. This is critical to address, since the cumulative effects of these stressors during spaceflight may result in unexpected negative impacts on crew health and performance that neither condition alone would predict, thus limiting the ability to develop effective countermeasures. Previously, we showed that both spaceflight and spaceflight analogue culture increased the virulence and pathogenesis-related characteristics of the foodborne pathogen, Salmonella Typhimurium (S. Typhimurium), which is responsible for disqualification of food destined for the International Space Station and Salmonella spp. have been found aboard NASA spacecraft. Recently, we demonstrated that spaceflight-analogue culture of S. Typhimurium increased its ability to infect 3-D biomimetic human intestinal tissue models. In a separate study, we showed low dose radiation damaged our 3-D intestinal models. The primary objective of this proposal is to evaluate the possibility that low dose radiation will exacerbate the already increased bacterial pathogenicity of S. Typhimurium observed following spaceflight analogue culture. In addition, we will determine the impact of a radiation countermeasure to provide protection against both radiation and pathogen-induced tissue damage and inflammation. Hypothesis: The already enhanced infection potential of spaceflight analogue cultured S. Typhimurium will be further exacerbated when used to infect host cells exposed to low dose radiation and this enhanced pathogenicity can be mitigated by a radioprotective compound. Aims: 1.Characterize the impact of spaceflight-analogue culture on the ability of S. Typhimurium to infect 3-D biomimetic intestinal tissue models before and after exposure to low dose radiation. 2. Evaluate the ability of the radioprotective compound, EC-18, to protect 3-D intestinal models from low dose radiation, S. Typhimurium infection, and the cumulative impact of these stressors. Significance: Current infectious disease risk assessments for spaceflight do not consider the potential for increased susceptibility to infection and disease resulting from exposure to low dose radiation, which is a critical consideration. This study will provide key evidence to determine if exposure to low dose radiation may be a factor in astronaut susceptibility to infection during long duration exploration missions and the impact of selected countermeasures to mitigate that risk to crew health. We have completed infection studies of the 3-D biomimetic intestinal tissue models and are currently analyzing the data.

Jennifer Barrila↗

Effects of Low Dose Radiation and Radiation Countermeasures on Infection by Spaceflight Analogue Cultured Salmonella Using 3-D Biomimetic Human Tissue Models

While both microgravity and radiation are major biological stressors associated with the spaceflight environment, their cumulative impact on host-pathogen interactions and infectious disease risks are rarely considered. This is critical to address, since the cumulative effects of these stressors during spaceflight may result in unexpected negative impacts on crew health and performance that neither condition alone would predict, thus limiting the ability to develop effective countermeasures. Previously, we showed that both spaceflight and spaceflight analogue culture increased the virulence and pathogenesis-related characteristics of the foodborne pathogen, Salmonella Typhimurium (S. Typhimurium), which is responsible for disqualification of food destined for the International Space Station and Salmonella spp. have been found aboard NASA spacecraft. Recently, we demonstrated that spaceflight-analogue culture of S. Typhimurium increased its ability to infect 3-D biomimetic human intestinal tissue models. In a separate study, we showed low dose radiation damaged our 3-D intestinal models. The primary objective of this proposal is to evaluate the possibility that low dose radiation will exacerbate the already increased bacterial pathogenicity of S. Typhimurium observed following spaceflight analogue culture. In addition, we will determine the impact of a radiation countermeasure to provide protection against both radiation and pathogen-induced tissue damage and inflammation. Hypothesis: The already enhanced infection potential of spaceflight analogue cultured S. Typhimurium will be further exacerbated when used to infect host cells exposed to low dose radiation and this enhanced pathogenicity can be mitigated by a radioprotective compound. Aims: 1. Characterize the impact of spaceflight-analogue culture on the ability of S. Typhimurium to infect 3-D biomimetic intestinal tissue models before and after exposure to low dose radiation. 2. Evaluate the ability of the radioprotective compound, EC-18, to protect 3-D intestinal models from low dose radiation, S. Typhimurium infection, and the cumulative impact of these stressors. Significance: Current infectious disease risk assessments for spaceflight do not consider the potential for increased susceptibility to infection and disease resulting from exposure to low dose radiation, which is a critical consideration. This study will provide key evidence to determine if exposure to low dose radiation may be a factor in astronaut susceptibility to infection during long duration exploration missions and the impact of selected countermeasures to mitigate that risk to crew health. This study has been initiated and data collection is beginning.

Jennifer Barrila↗

Detailed SCALE Dose Rate Evaluations for a Consolidated Interim Spent Nuclear Fuel Storage Facility

This paper presents a confirmatory dose rate calculation for a proposed consolidated interim spent nuclear fuel (SNF) storage facility (CISF). The proposed CISF was modeled in detail using SCALE 6.2.1 to determine the radiation dose map of the surrounding areas of the facility and determine the location of the controlled area boundary based on 10 CFR 72.104 requirements. The spatial dose rate distribution was determined as the total dose rate contributions by each of the 467 storage casks comprising the CISF. A rectangular boundary outside of which no dose rate exceeds 25 mrem/yr has the dimensions of 1.25 km x 1.25 km. It denotes the smallest rectangle that could serve as the controlled area boundary. The results (dose map) show the unique capability of the SCALE code system for a high-resolution radiation dose simulation of a large SNF storage facility.

Radulescu, Georgeta↗

Methods for determining absorbed dose information

The disclosure discusses methods for determining absorbed dose information. A tomography imaging device generates an anatomy image relating to anatomy of a particular patient. A tomography imaging device also generates multiple radioactivity images regarding radioactivity distribution of an internally administered pharmaceutical over time in the particular patient. The radioactivity images related to the radioactivity distribution over time are registered. Each radioactivity image is combined with each anatomy image to create activity images. A Monte Carlo simulation for each activity image is run to obtain absorbed dose-rate images of the pharmaceutical at multiple times. The absorbed dose-rate images are integrated over time to obtain a total absorbed dose image. The absorbed dose-rate images and the total absorbed dose image are used to obtain a biologically effective dose (BED) image. The BED image is used to obtain an equivalent uniform does (EUD) of BED values for a chosen anatomical region.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Forward Intensity-Modulated Radiotherapy Planning in Breast Cancer to Improve Dose Homogeneity: Feasibility of Class Solutions

Purpose: To explore forward planning methods for breast cancer treatment to obtain homogeneous dose distributions (using International Commission on Radiation Units and Measurements criteria) within normal tissue constraints and to determine the feasibility of class solutions. Methods and Materials: Treatment plans were optimized in a stepwise procedure for 60 patients referred for postlumpectomy irradiation using strict dose constraints: planning target volume (PTV){sub 95%} of >99%; V{sub 107%} of <1.8 cc; heart V{sub 5Gy} of <10% and V{sub 10Gy} of <5%; and mean lung dose of <7 Gy. Treatment planning started with classic tangential beams. Optimization was done by adding a maximum of four segments before adding beams, in a second step. A breath-hold technique was used for heart sparing if necessary. Results: Dose constraints were met for all 60 patients. The classic tangential beam setup was not sufficient for any of the patients; in one-third of patients, additional segments were required (<3), and in two-thirds of patients, additional beams (<2) were required. Logistic regression analyses revealed central breast diameter (CD) and central lung distance as independent predictors for transition from additional segments to additional beams, with a CD cut-off point at 23.6 cm. Conclusions: Treatment plans fulfilling strict dose homogeneity criteria and normal tissue constraints could be obtained for all patients by stepwise dose intensity modification using limited numbers of segments and additional beams. In patients with a CD of >23.6 cm, additional beams were always required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anastomotic Complications After Ivor Lewis Esophagectomy in Patients Treated With Neoadjuvant Chemoradiation Are Related to Radiation Dose to the Gastric Fundus

Purpose: Neoadjuvant chemoradiation (CRT) is increasingly used in locally advanced esophageal cancer. Some studies have suggested that CRT results in increased surgical morbidity. We assessed the influence of CRT on anastomotic complications in a cohort of patients who underwent CRT followed by Ivor Lewis esophagectomy. Patients and Methods: Clinical and pathologic data were collected from all patients treated with neoadjuvant CRT (36 Gy combined with 5-fluorouracil and cisplatin) followed by Ivor Lewis esophagectomy. On the radiotherapy (RT) planning computed tomography scans, normal tissue volumes were drawn encompassing the proximal esophageal region and the gastric fundus. Within these volumes, dose-volume histograms were analyzed to generate the total dose to 50% of the volume (D{sub 50}). We studied the ability of the D{sub 50} to predict anastomotic complications (leakage, ischemia, or stenosis). Dose limits were derived using receiver operating characteristics analysis. Results: Fifty-four patients were available for analysis. RT resulted in either T or N downstaging in 51% of patients; complete pathologic response was achieved in 11%. In-hospital mortality was 5.4%, and major morbidity occurred in 36% of patients. Anastomotic complications (AC) developed in 7 patients (13%). No significant influence of the D{sub 50} on the proximal esophagus was noted on the anastomotic complication rate. The median D{sub 50} on the gastric fundus, however, was 33 Gy in patients with AC and 18 Gy in patients without AC (p = 0.024). Using receiver operating characteristics analysis, the D{sub 50} limit on the gastric fundus was defined as 29 Gy. Conclusions: In patients undergoing neoadjuvant CRT followed by Ivor Lewis esophagectomy, the incidence of AC is related to the RT dose on the gastric fundus but not to the dose received by the proximal esophagus. When planning preoperative RT, efforts should be made to limit the median dose on the gastric fundus to 29 Gy with a V{sub 30} below 40%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron Irradiation of Conjunctival Lymphoma-Monte Carlo Simulation of the Minute Dose Distribution and Technique Optimization

Purpose: External beam radiotherapy is the only conservative curative approach for Stage I non-Hodgkin lymphomas of the conjunctiva. The target volume is geometrically complex because it includes the eyeball and lid conjunctiva. Furthermore, the target volume is adjacent to radiosensitive structures, including the lens, lacrimal glands, cornea, retina, and papilla. The radiotherapy planning and optimization requires accurate calculation of the dose in these anatomical structures that are much smaller than the structures traditionally considered in radiotherapy. Neither conventional treatment planning systems nor dosimetric measurements can reliably determine the dose distribution in these small irradiated volumes. Methods and Materials: The Monte Carlo simulations of a Varian Clinac 2100 C/D and human eye were performed using the PENELOPE and PENEASYLINAC codes. Dose distributions and dose volume histograms were calculated for the bulbar conjunctiva, cornea, lens, retina, papilla, lacrimal gland, and anterior and posterior hemispheres. Results: The simulated results allow choosing the most adequate treatment setup configuration, which is an electron beam energy of 6 MeV with additional bolus and collimation by a cerrobend block with a central cylindrical hole of 3.0 cm diameter and central cylindrical rod of 1.0 cm diameter. Conclusions: Monte Carlo simulation is a useful method to calculate the minute dose distribution in ocular tissue and to optimize the electron irradiation technique in highly critical structures. Using a voxelized eye phantom based on patient computed tomography images, the dose distribution can be estimated with a standard statistical uncertainty of less than 2.4% in 3 min using a computing cluster with 30 cores, which makes this planning technique clinically relevant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗