Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control and Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Systems and Methods for Collaboratively Controlling at Least One Aircraft

An unmanned vehicle management system includes an unmanned aircraft system (UAS) control station controlling one or more unmanned vehicles (UV), a collaborative routing system, and a communication network connecting the UAS and the collaborative routing system. The collaborative routing system being configured to receive flight parameters from an operator of the UAS control station and, based on the received flight parameters, automatically present the UAS control station with flight plan options to enable the operator to operate the UV in a defined airspace.

Estkowski, Regina I.↗

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain↗

Performance of a Regenerative Fuel Cell System for the Lunar Surface

Regenerative fuel cells (RFCs) are an attractive energy storage solution for lunar missions as a technology capable of providing a higher specific energy (i.e., W∙h/kg) than state-of-the-art packaged Li-ion battery systems. An RFC consists of the (1 & 2) electrochemical stacks (chemical to electrical energy conversion to supply electricity to an external load, i.e. the fuel cell reaction, and electrical to chemical energy conversion of supplied electrical power to dissociate water into hydrogen and oxygen gases, i.e. water electrolysis), (3) fluidic conditioning, (4) reactant storage, (5) avionics, (6) power management and distribution (PMAD), and (7) thermal management. NASA’s Glenn Research Center has designed, assembled, and tested a breadboard RFC sys-tem capable of operating autonomously for multiple simulated lunar day/night cycles in a laboratory environment. The system is comprised of a non-flow through proton exchange membrane (PEM) fuel cell stack and a liquid-anode feed PEM electrolyzer (EZ) stack designed to electrochemically compress the reactants at balanced pressures up to 12.4 MPa (1800 psia). The fluidic conditioning, avionics, PMAD, and thermal management sub-systems are largely comprised of commercial-off-the-shelf components for this system-level development effort. The hardware is controlled by a CubeSat space processor running an operational program based on core flight architecture that can control the RFC hardware autonomously through a state machine with fault monitoring. The testing results highlighted here were completed with the system in an open-loop configuration such that reactants generated through water electrolysis were vented while gas cylinders supplied fuel cell operation. The breadboard operated autonomously, but there were five unplanned transitions to a safe state that required a manual restart after reviewing the data, determining a root cause, and implementing a solution. Four of the transitions were caused by the thermal management subsystem and the fifth was caused by a water management control issue in the EZ sub-system. The RFC system operated for over 550 hours with the final cycle being slightly abbreviated due to reasons unrelated to system performance.

Kerrigan Cain↗

Utility Microgrid Controller Test Plan

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) DER. In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this first edition report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Cooperative Multi-Agent Deep Reinforcement Learning Framework for Real-Time Residential Load Scheduling

Internet-of-Things (IoT) enabled monitoring and control capabilities are enabling increasing numbers of household users with controllable loads to actively participate in smart grid energy management. Realizing an efficient real-time energy management system that takes advantage of these developments requires novel techniques for managing the increased complexity of the control action space in resolving multiple challenges such as the uncertainty in energy prices and renewable energy output along with the need to satisy physical grid constraints such as transformer capacity. Addressing these challenges, we develop a multi-household energy management framework for residential units connected to the same transformer and containing DERs such as PV, ESS and controllable loads. The goal of our framework is to schedule controllable household appliances and ESS such that the cost of procuring electricity from the utility over a horizon is minimized while physical grid constraints are satisfied at each scheduling step. Traditional energy management frameworks either perform global optimization to satisfy grid constraints but suffer from high computational complexity (for example Integer Program, Mixed Integer Programming frameworks and centralized reinforcement learning) or perform decentralized real-time energy management without satisfying global grid constraints (for example multi-agent reinforcement learning with no cooperation). In contrast, we propose a cooperative multiagent reinforcement learning (MARL) framework that i) operates in real-time, and ii) performs explicit collaboration to satisfy global grid constraints. The novelty in our framework is two fold. Firstly, our framework trains multiple independent learners (IL) for each household in parallel using historical data and performs real-time inferencing of control actions using the most recent system state. Secondly, our framework contains a low complexity knapsack based cooperation agent which combines the outputs of ILs to minimize cost while satisfying grid constraints. Simulation results show that our cooperative MARL approach achieves significant cost improvement over centralized reinforcement learning and day-ahead planning baselines. Moreover, our approach strictly satisfies physical constraints with no apriori knowledge of system dynamics while the baseline approaches have occasional violations. We also measure the training and inference time by ranging the number of households from 1 to 25. Results show that our cooperative MARL approach scales best among various approaches.

14 SOLAR ENERGY↗

Ground based simulation of life sciences Spacelab experiments

The third in a series of Spacelab Mission Development tests was a joint effort of the Ames Research and Johnson Space Centers to evaluate planned operational concepts of the Space Shuttle life sciences program. A three-man crew conducted 26 experiments and 12 operational tests, utilizing both human and animal subjects. The crew lived aboard an Orbiter/Spacelab mockup for the seven-day simulation. The Spacelab was identical in geometry to the European Space Agency design, complete with removable rack sections and stowage provisions. Communications were controlled as currently planned for operational Shuttle flights. A Science Operations Remote Center at the Ames Research Center was managed by simulated Mission Control and Payload Operation Control Centers at the Johnson Space Center. This paper presents the test objectives, describes the facilities and test program, and outlines the results of this test.

Rummel, J. A.↗

Tug avionics system overview

The recently defined Tug avionics system takes maximum advantage of projected technology advances to attain: low system weight; power system capacity essentially independent of mission duration; sensors for rendezvous, docking, and navigation update; all attitude communications; onboard checkout and redundancy management; and modular fault tolerant computer control. The requirements, selection trades, and configurations are discussed for the major subsystems: data management, guidance navigation and control, communications, rendezvous and docking, and electrical power. The integrated avionics system and the interfaces with the payload, Shuttle and ground are described.

Raaberg, M. T.↗

Trajectory Specification for High-Capacity Air Traffic Control

In the current air traffic management system, the fundamental limitation on airspace capacity is the cognitive ability of human air traffic controllers to maintain safe separation with high reliability. The doubling or tripling of airspace capacity that will be needed over the next couple of decades will require that tactical separation be at least partially automated. Standardized conflict-free four-dimensional trajectory assignment will be needed to accomplish that objective. A trajectory specification format based on the Extensible Markup Language is proposed for that purpose. This format can be used to downlink a trajectory request, which can then be checked on the ground for conflicts and approved or modified, if necessary, then uplinked as the assigned trajectory. The horizontal path is specified as a series of geodetic waypoints connected by great circles, and the great-circle segments are connected by turns of specified radius. Vertical profiles for climb and descent are specified as low-order polynomial functions of along-track position, which is itself specified as a function of time. Flight technical error tolerances in the along-track, cross-track, and vertical axes define a bounding space around the reference trajectory, and conformance will guarantee the required separation for a period of time known as the conflict time horizon. An important safety benefit of this regimen is that the traffic will be able to fly free of conflicts for at least several minutes even if all ground systems and the entire communication infrastructure fail. Periodic updates in the along-track axis will adjust for errors in the predicted along-track winds.

Paielli, Russell A.↗

Event-Driven Predictive Approach for Real-Time Volt/VAR control with CVR in solar PV rich Active Distribution Network

The focus of this paper is on analyzing the impact of conservation voltage reduction in the presence of active devices such as solar photovoltaic (PV) and developing controls that leverage these distributed energy resources. An event-driven predictive approach for real-time volt/volt-ampere reactive (VAR) optimization, along with local two-level adaptive volt/VAR droop-based control algorithm for advanced distribution management systems, is introduced. The methodology covers aggregated and autonomous controls under different timescale operations, including the impact and effect of unpredicted events such as cloud transients on PV power production. In addition, the control schemes include the uncertainties in PV power generation and load power demand. The proposed methodology is validated in a real-time framework using the real-time digital simulator platform through co-simulation with models based on Python and OpenDSS (Open Distribution System Simulator). The developed methodology is tested on the modified IEEE 123-feeder test system. The results reveal that the proposed methodology works well in the presence of high penetrations of PV power, produces significant energy savings, and mitigates over-/undervoltage problems.

14 SOLAR ENERGY↗

Control - Demands mushroom as station grows

The NASA space station, which is presently in the planning stage, is to be composed of both rigid and nonrigid modules, rotating elements, and flexible appendages subjected to environmental disturbances from the earth's atmospheric gravity gradient, and magnetic field, as well as solar radiation and self-generated disturbances. Control functions, which will originally include attitude control, docking and berthing control, and system monitoring and management, will with evolving mission objectives come to encompass such control functions as articulation control, autonomous navigation, space traffic control, and large space structure control. Attention is given to the advancements in modular, distributed, and adaptive control methods, as well as system identification and hardware fault tolerance techniques, which will be required.

Szirmay, S. Z.↗

Workplace Charge Management with Aggregated Building Loads

This paper describes a workplace charge management system developed to control plug-in electric vehicle charging stations based on aggregated building loads. A system to collect information from drivers was also developed for better charge management performance since the present AC charging station standard does not provide battery state of charge information. First, simulations with uncontrolled charging data were conducted to investigate several scenarios and control methods, and then one method with the most power curtailment during peak load was selected for verification tests. This paper illustrates load reduction test results for 36 charging stations and real-time campus net load data.

25 ENERGY STORAGE↗

Laboratory Evaluation of Commercial Utility Microgrid Controller Test Results

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) distributed energy resources (DER). In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. This second edition update also includes results from applying the tests to a commercial utility microgrid controller. These results evaluate the performance and reliability of the controller under various operational scenarios. It identifies specific areas where the controller excels and highlights gaps that need to be addressed for future enhancements. The application of these test plans on real-world system behavior provides insights on commercial equipment readiness for field deployment. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Discrete Event Simulation-Based Timeline Validation Using R2U2

The Gateway Vehicle Systems Manager (VSM), the top-level software control system in a distributed, hierarchical Autonomous System Management Architecture is, like most modern spacecraft software control systems, heavily data-driven. For example, schedules (timelines) will be developed on the ground and, due to the high degree of autonomy, contain complex procedures involving conditional branching, variable timing, and resource contention resolution. In order to verify that an uploaded timeline will function correctly, it is necessary to explore the feasible set of possible executions. While it is possible to test a timeline using a mission simulation, the complexity of the system and duration of a timeline limits the number of trials and therefore the test coverage. To address this problem, the VSM team is using a discrete event system model that can rapidly generate from a timeline sets of event sequences using Monte Carlo techniques. To achieve rapid and trustworthy checking of the event sequences, we use an offline version of the runtime model checking tool R2U2. This presentation describes the approach the VSM team is using to implement the discrete event simulation and evaluate event sequences using R2U2. The presentation will discuss: 1. Description of the timelines by VSM in the context of VSM operations 2. Expansion of a timeline into a sequence of atomic events 3. Adjustment, in the Monte Carlo environment, of an event sequence to account for uncertainty, external events, and failures 4. Definition of R2U2 input and mission-time linear temporal logic files 5. Generation and use of R2U2 verdict sequences 6. Lessons learned and future work

Verification↗

Tether dynamics and control results for tethered satellite system's initial flight

The recent Tethered Satellite System-1 (TSS-1) mission has provided a wealth of data concerning the dynamics of tethered systems in space and has demonstrated the effectiveness of operational techniques designed to control these dynamics. In this paper, we review control techniques developed for managing tether dynamics, and discuss the results of using these techniques for the Tethered Satellite System's maiden flight on STS-46. In particular, the flight results of controlling libration dynamics, string dynamics, and slack tether are presented. These results show that tether dynamics can be safely managed. The overall stability of the system was found to be surprisingly good even at relatively short tether lengths. In fact, the system operated in passive mode at a tether length of 256 meters for over 9 hours. Only monitoring of the system was required during this time. Although flight anomalies prevented the planned deployment to 20 km, the extended operations at shorter tether lengths have proven the viability of using tethers in space. These results should prove invaluable in preparing for future missions with tethered objects in space.

Chapel, Jim D.↗

Battery Energy Storage System (BESS) and Battery Management System (BMS) for Grid-Scale Applications

The current electric grid is an inefficient system that wastes significant amounts of the electricity it produces because there is a disconnect between the amount of energy consumers require and the amount of energy produced from generation sources. Power plants typically produce more power than necessary to ensure adequate power quality. By taking advantage of energy storage within the grid, many of these inefficiencies can be removed. Advanced modeling is required when using battery energy storage systems (BESS) for grid storage in order to accurately monitor and control the storage system. Battery management systems (BMS) control how the storage system will be used and a BMS that utilizes advanced physics-based models will offer for much more robust operation of the storage system. The paper outlines the current state of the art for modeling in BMS and the advanced models required to fully utilize BMS for both lithium-ion batteries and vanadium redox-flow batteries. In addition, system architecture and how it can be useful in monitoring and control is discussed. A pathway for advancing BMS to better utilize BESS for grid-scale applications is outlined.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using a CLIPS expert system to automatically manage TCP/IP networks and their components

A expert system that can directly manage networks components on a Transmission Control Protocol/Internet Protocol (TCP/IP) network is described. Previous expert systems for managing networks have focused on managing network faults after they occur. However, this proactive expert system can monitor and control network components in near real time. The ability to directly manage network elements from the C Language Integrated Production System (CLIPS) is accomplished by the integration of the Simple Network Management Protocol (SNMP) and a Abstract Syntax Notation (ASN) parser into the CLIPS artificial intelligence language.

Faul, Ben M.↗

Tuning of Nacelle Feedback Gains for Floating Wind Turbine Controllers Using a Two-DOF Model

Designing a collective blade pitch controller for floating offshore wind turbines (FOWTs) poses unique challenges due to the interaction of the controller with the dynamics of the platform. The controller must also handle the competing objectives of power production performance and fatigue load management. Existing solutions either detune the controller with the result of slowed response, make use of complicated tuning methods, or incorporate a nacelle velocity feedback gain. With the goal of developing a simple control tuning method for the general FOWT researcher that is easily extensible to a wide array of turbine and hull configurations, this last idea is built upon by proposing a simple tuning strategy for the feedback gain. This strategy uses a two degree-of-freedom (DoF) turbine model that considers tower-top fore-aft and rotor angular displacements. For evaluation, the nacelle velocity term is added to an existing gain scheduled proportional-integral controller as a proportional gain. The modified controller is then compared to baseline land-based and detuned controllers on an example system for several load cases. First-pass results are favorable, demonstrating how researchers can use the proposed tuning method to efficiently schedule gains for adequate controller performance as they investigate new FOWT configurations.

49 EE - Wind and Water Power Program - Wind (EE-4W↗