Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computer Codes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

The SRT reconstruction algorithm for semiquantification in PET imaging

Purpose: The spline reconstruction technique (SRT) is a new, fast algorithm based on a novel numerical implementation of an analytic representation of the inverse Radon transform. The mathematical details of this algorithm and comparisons with filtered backprojection were presented earlier in the literature. In this study, the authors present a comparison between SRT and the ordered-subsets expectation–maximization (OSEM) algorithm for determining contrast and semiquantitative indices of {sup 18}F-FDG uptake. Methods: The authors implemented SRT in the software for tomographic image reconstruction (STIR) open-source platform and evaluated this technique using simulated and real sinograms obtained from the GE Discovery ST positron emission tomography/computer tomography scanner. All simulations and reconstructions were performed in STIR. For OSEM, the authors used the clinical protocol of their scanner, namely, 21 subsets and two iterations. The authors also examined images at one, four, six, and ten iterations. For the simulation studies, the authors analyzed an image-quality phantom with cold and hot lesions. Two different versions of the phantom were employed at two different hot-sphere lesion-to-background ratios (LBRs), namely, 2:1 and 4:1. For each noiseless sinogram, 20 Poisson realizations were created at five different noise levels. In addition to making visual comparisons of the reconstructed images, the authors determined contrast and bias as a function of the background image roughness (IR). For the real-data studies, sinograms of an image-quality phantom simulating the human torso were employed. The authors determined contrast and LBR as a function of the background IR. Finally, the authors present plots of contrast as a function of IR after smoothing each reconstructed image with Gaussian filters of six different sizes. Statistical significance was determined by employing the Wilcoxon rank-sum test. Results: In both simulated and real studies, SRT exhibits higher contrast and lower bias than OSEM at the cold lesions. This improvement is achieved at the expense of increasing the noise in the reconstructed images. For the hot lesions, SRT exhibits a small improvement in contrast and LBR over OSEM with 21 subsets and two iterations; however, this improvement is not statistically significant. As the number of iterations increases, the performance of OSEM improves over SRT but again without statistical significance. The curves of contrast and LBR as a function of IR after Gaussian blurring indicate that the advantage of SRT in the cold regions is maintained even after decreasing the noise level by Gaussian blurring. Conclusions: SRT, at the expense of slightly increased noise in the reconstructed images, reconstructs images of higher contrast and lower bias than the clinical protocol of OSEM. This improvement is particularly evident for images involving cold regions. Thus, it appears that SRT should be particularly useful for the quantification of low-count and cold regions.

60 APPLIED LIFE SCIENCES↗

SU-F-T-477: Investigation of DEFGEL Dosimetry Using MRI

Purpose: The DEFGEL dosimeter/phantom allows for the measurement of 3D dose distributions while maintaining tissue equivalence and deformability. Although DEFGEL is traditionally read out with optical CT, the use of MRI would permit the measurement of 3D dose distributions in optically interfering configurations, like while embedded in a phantom. To the knowledge of the authors, this work is the first investigation that uses MRI to measure dose distributions in DEFGEL dosimeters. Methods: The DEFGEL (6%T) formula was used to create 1 cm thick, 4.5 cm diameter cylindrical dosimeters. The dosimeters were irradiated using a Varian Clinac 21EX linac. The MRI based transverse relaxation rate (R2) of the gel was measured in a central slice of the dosimeter with a Spin-Echo (SE) pulse sequence on a 3T GE SIGNA PET/MR scanner. The R2 values were fit to a monoexponential dose response equation using in-house software (MATLAB). Results: The data was well fit using a monoexponential fit for R2 as a function of absorbed dose (R{sup 2} = 0.9997). The fitting parameters of the monoexponential fit resulted in a 0.1229 Gy{sub −1}s{sub −1} slope. The data also resulted in an average standard deviation of 1.8% for the R2 values within the evaluated ROI. Conclusion: The close fit for the dose response curve shows that a DEFGEL based dosimeter can be paired with a SE MRI acquisition. The Type A uncertainty of the MRI method shows adequate precision, while the slope of the fit curve is large enough that R2 differences between different gel doses are distinguishable. These results suggest that the gel could potentially be used in configurations where an optical readout is not viable, such as measurements with the gel dosimeter positioned inside larger or optically opaque phantoms. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-02: Application of Changs Attenuation Correction Technique for SPECT Partial Angle Acquisition of Jaszczak Phantom

Purpose: Chang’s mathematical formulation is a common method of attenuation correction applied on reconstructed Jaszczak phantom images. Though Chang’s attenuation correction method has been used for 360° angle acquisition, its applicability for 180° angle acquisition remains a question with one vendor’s camera software producing artifacts. The objective of this work is to ensure that Chang’s attenuation correction technique can be applied for reconstructed Jaszczak phantom images acquired in both 360° and 180° mode. Methods: The Jaszczak phantom filled with 20 mCi of diluted Tc-99m was placed on the patient table of Siemens e.cam™ (n = 2) and Siemens Symbia™ (n = 1) dual head gamma cameras centered both in lateral and axial directions. A total of 3 scans were done at 180° and 2 scans at 360° orbit acquisition modes. Thirty two million counts were acquired for both modes. Reconstruction of the projection data was performed using filtered back projection smoothed with pre reconstruction Butterworth filter (order: 6, cutoff: 0.55). Reconstructed transaxial slices were attenuation corrected by Chang’s attenuation correction technique as implemented in the camera software. Corrections were also done using a modified technique where photon path lengths for all possible attenuation paths through a pixel in the image space were added to estimate the corresponding attenuation factor. The inverse of the attenuation factor was utilized to correct the attenuated pixel counts. Results: Comparable uniformity and noise were observed for 360° acquired phantom images attenuation corrected by the vendor technique (28.3% and 7.9%) and the proposed technique (26.8% and 8.4%). The difference in uniformity for 180° acquisition between the proposed technique (22.6% and 6.8%) and the vendor technique (57.6% and 30.1%) was more substantial. Conclusion: Assessment of attenuation correction performance by phantom uniformity analysis illustrated improved uniformity with the proposed algorithm compared to the camera software.

60 APPLIED LIFE SCIENCES↗

Trust Management Considerations For the Cooperative Infrastructure Defense Framework: Trust Relationships, Evidence, and Decisions

Cooperative Infrastructure Defense (CID) is a hierarchical, agent-based, adaptive, cyber-security framework designed to collaboratively protect multiple enclaves or organizations participating in a complex infrastructure. CID employs a swarm of lightweight, mobile agents called Sensors designed to roam hosts throughout a security enclave to find indications of anomalies and report them to host-based Sentinels. The Sensors’ findings become pieces of a larger puzzle, which the Sentinel puts together to determine the problem and respond per policy as given by the enclave-level Sergeant agent. Horizontally across multiple enclaves and vertically within each enclave, authentication and access control technologies are necessary but insufficient authorization mechanisms to ensure that CID agents continue to fulfill their roles in a trustworthy manner. Trust management fills the gap, providing mechanisms to detect malicious agents and offering more robust mechanisms for authorization. This paper identifies the trust relationships throughout the CID hierarchy, the types of trust evidence that could be gathered, and the actions that the CID system could take if an entity is determined to be untrustworthy.

97 MATHEMATICS AND COMPUTING↗

Science for Problems Under the Surface

Humans have entered into and explored a wide range of environments, ranging from the deep ocean to the upper atmosphere and even outer space. But for the most part, the subsurface environment hidden beneath the surface of our planet remains enigmatic and directly observable only through limited points of access. Nevertheless, physical, chemical and biological processes in Earth’s subsurface are central players in several interrelated energy and environmental issues critical to the world’s security and economy. Leadership-class computing will soon be brought to bear on understanding and predicting these processes across a wide range of time and space scales.

58 GEOSCIENCES↗

A Stigmergy Approach for Open Source Software Developer Community Simulation

The stigmergy collaboration approach provides a hypothesized explanation about how online groups work together. In this research, we presented a stigmergy approach for building an agent based open source software (OSS) developer community collaboration simulation. We used group of actors who collaborate on OSS projects as our frame of reference and investigated how the choices actors make in contribution their work on the projects determinate the global status of the whole OSS projects. In our simulation, the forum posts and project codes served as the digital pheromone and the modified Pierre-Paul Grasse pheromone model is used for computing developer agent behaviors selection probability.

97 MATHEMATICS AND COMPUTING↗

LA17-V-InverseRadTransportProblem-PD2Kb. Final Project Report

In the inverse radiation transport problem, a radiation signal emanating from an unknown object is used to reconstruct geometric and material parameters of the object , e.g., the mass of special nuclear material (SNM), the isotopic composition of the SNM (e.g., the enrichment of 235U), the thickness of shielding, etc. The inverse radiation transport problem is one of the most fundamental and important in the emergency response mission, and has been addressed in previous NA-22 and NA-42/84 investments by using derivative-free optimization methods. Our project was aimed at (i) consolidating previous work by applying polynomial chaos expansion (PCE) for reducing significantly the number of forward model simulations required by derivative-free optimization methods; (ii) developing a general-purpose framework and stand-alone software for solving the inverse radiation transport problem by applying a new “predictive modeling” methodology (predictive modeling of coupled multi-physics systems, PM_CMPS) which enables the fusing of experimental and computational information; and (iii) developing several benchmarks (for unscattered gamma rays) for demonstrating the quantification of non-Gaussian features (e.g., skewness and kurtosis, which characterize asymmetries and long tails) of response distributions by deterministically and efficiently propagating parameter uncertainties (covariances and higher-order moments, where available) using high-order sensitivities computed by the recently developed comprehensive adjoint sensitivity analysis methodology (C-ASAM). With regard to (i), application of PCE, the most significant accomplishment of this project was an implementation of PCE into INVERSE that significantly reduced computation time for the DiffeRential Evolution Adaptive Metropolis (DREAM) and Differential Evolution (DE) methods. For inverse transport problems with measurements of neutron leakage, neutron multiplication, and neutron-induced gamma-rays, the solution times for the DREAM and DE methods were reduced by factors of 30-300, reducing run times from hours to minutes while maintaining the same accuracy as the standard (non-PCE) DREAM and DE. Speedups were further improved by exploring sparse grid quadrature sets using the Toolkit for Adaptive Stochastic Modeling and Non-Intrusive ApproximatioN (Tasmanian) toolset. An initial exploration of sparse grids indicated that further speedups factors of 5-10 are obtainable. The implementation of PCE in INVERSE is not in a form that users can easily access. With regard to (ii), solving the inverse problem using a predictive modeling paradigm, the most significant accomplishment of this project were the derivation and implementation of adjoint-based second derivatives in neutron and photon transport theory. There are two codes that compute these derivatives. SENSPG computes them for uncollided gamma rays and SENSMG computes them for neutron leakage. SENSMG is open-source code available on github. Other significant accomplishments included a stand-alone code, MULTI-PRED, that implements the predictive modeling paradigm, along with a detailed manual. The code was implemented in the existing INVERSE code for inverse problems, but a head-to-head comparison of inverse methods was not achieved. We also derived and implemented the capability to compute sensitivities for multiplicity measurements into the SENSMG code, and this capability was used in a data assimilation application, but it was not used for solving inverse problems. With regard to (iii), developing benchmarks to demonstrate the importance of high-order sensitivity and uncertainty analysis, the most significant accomplishment of this project were two test problems that showed how important second-order sensitivities are.

07 ISOTOPE AND RADIATION SOURCES↗

eBPF Community ID Calculation

The code titled “eBPF Community ID Calculation” allows easy correlation of monitoring logs with existing network forensics logs on high-performance computing (HPC) systems. This code implements the Community ID Flow Hashing standard to calculate community ID Flow identifiers. These identifiers will be used to correlate host forensics logs with network forensics logs. The correlation provides valuable insight and the ability to easily pivot between disparate data sources. The computer code removes the libpcap dependency from the code base.

Maerz, StefanA↗

Software Design Document for the AMP Nuclear Fuel Performance Code

The purpose of this document is to describe the design of the AMP nuclear fuel performance code. It provides an overview of the decomposition into separable components, an overview of what those components will do, and the strategic basis for the design. The primary components of a computational physics code include a user interface, physics packages, material properties, mathematics solvers, and computational infrastructure. Some capability from established off-the-shelf (OTS) packages will be leveraged in the development of AMP, but the primary physics components will be entirely new. The material properties required by these physics operators include many highly non-linear properties, which will be replicated from FRAPCON and LIFE where applicable, as well as some computationally-intensive operations, such as gap conductance, which depends upon the plenum pressure. Because there is extensive capability in off-the-shelf leadership class computational solvers, AMP will leverage the Trilinos, PETSc, and SUNDIALS packages. The computational infrastructure includes a build system, mesh database, and other building blocks of a computational physics package. The user interface will be developed through a collaborative effort with the Nuclear Energy Advanced Modeling and Simulation (NEAMS) Capability Transfer program element as much as possible and will be discussed in detail in a future document.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extension of the Inverse Adding-Doubling Method to the Measurement of Wavelength-Dependent Absorption and Scattering Coefficients of Biological Samples

Light interaction with biological tissue can be described using three parameters: the scattering and absorption coefficients (us and ua), as well as the anisotropy (g) which describes the directional dependence of the scattered photons. Accurately determining these optical properties for different tissue types at specific wavelengths, and simultaneously, would be beneficial for a variety of different biomedical applications. The goal of this project was to take a user-defined g-value and determine the remaining two parameters for a specified wavelength range for an integrating sphere with a collimated white light input source system. A fully automated computer program and process was developed to collect data for all wavelengths in a timely and accurate manner. LabVIEW was used to write programs to automate: raw intensity data collection from a spectrometer equipped integrating sphere, conversion of the data into a format for analysis via Scott Prahl's Inverse Adding-Doubling (IAD) C code execution, and computation of the optical properties based on the output from the IAD code. To allow data to be passed efficiently between LabVIEW and C code program modules, the two were combined into a single program (OPT 3.1). OPT 3.1 was tested using tissue mimicking phantoms and determination of the absorption and scattering coefficients showed excellent agreement with theory for wavelengths were the user inputted single g-value was sufficiently precise. Future improvements entail providing for multi-wavelength g-value entry to extend the accuracy of results to encompass the complete system multispectral range. Ultimately, the data collection process and algorithms developed through this effort will be used to study actual biological tissues for the purpose of deriving and refining models for light-tissue interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A boundary integral method for numerical computation of radar cross section of 3D targets using hybrid BEM/FEM with edge elements

This contribution presents the boundary integral formulation for numerical computation of time-harmonic radar cross section for 3D targets. Method relies on hybrid edge element BEM/FEM to compute near field edge element coefficients that are associated with near electric and magnetic fields at the boundary of the computational domain. Special boundary integral formulation is presented that computes radar cross section directly from these edge element coefficients. Consequently, there is no need for near-to-far field transformation (NTFFT) which is common step in RCS computations. By the end of the paper it is demonstrated that the formulation yields accurate results for canonical models such as spheres, cubes, cones and pyramids. Method has demonstrated accuracy even in the case of dielectrically coated PEC sphere at interior resonance frequency which is common problem for computational electromagnetic codes. - Graphical abstract: - Highlights: • Hybrid edge element BEM/FEM is used to find edge element coefficients. • New formulation for RCS computation directly from edge element coefficients is presented. • Formulation is tested on canonical cases and on coated dielectric sphere at interior resonance frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

OTERR User Manual

OTERR (Optimization of TEst Reactor Reloading) is a software tool created to assist in the determination of optimal fuel reloading patterns for test reactors. The intended application is for the Versatile Test Reactor (VTR) program, but it provides functions that could be useful for analysis and optimization of many types of fast reactors. OTERR does not perform neutron/gamma transport, heat transfer, thermal hydraulics, or depletion calculations. Instead, it acts as a wrapper around codes that provide these capabilities, with a native genetic algorithm optimization capability. At this time, wrapping is only implemented for Argonne Reactor Computation (ARC) codes DIF3D, REBUS, and GAMSOR, and SE2-ANL. OTERR also has capabilities to facilitate input creation for DASSH, a thermal hydraulics code similar to SE2- ANL being developed for the VTR program.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Standard Lexicons, Coding Systems and Ontologies for Interoperability and Semantic Computation in Imaging

Standard clinical terms, codes, and ontologies promote clarity and interoperability. Within radiology, there is a variety of relevant content resources, tools and technologies. These provide the basis for fundamental imaging workflows such as reporting and billing, and also facilitate a range of applications in quality improvement and research. This article reviews the key characteristics of lexicons, coding systems, and ontologies. A number of standards are described, including International Classification of Diseases-10-Clinical Modification (ICD-10-CM), Current Procedural Terminology (CPT), Systematized Nomenclature of Medicine—Clinical Terms (SNOMED CT), Logical Observation Identifiers Names and Codes (LOINC), and RadLex. Tools for accessing this material are reviewed, such as the National Center for Biomedical Ontology BioPortal system. Web services are discussed as a mechanism for semantic application development. Several example systems, workflows, and research applications using semantic technology are also surveyed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation Studies of Hydrogen Ion reflection from Tungsten for the Surface Production of Negative Hydrogen Ions

The production efficiency of negative ions at tungsten surface by particle reflection has been investigated. Angular distributions and energy spectra of reflected hydrogen ions from tungsten surface are calculated with a Monte Carlo simulation code ACAT. The results obtained with ACAT have indicated that angular distributions of reflected hydrogen ions show narrow distributions for low-energy incidence such as 50 eV, and energy spectra of reflected ions show sharp peaks around 90% of incident energy. These narrow angular distributions and sharp peaks are favorable for the efficient extraction of negative ions from an ion source equipped with tungsten surface as negative ionization converter. The retained hydrogen atoms in tungsten lead to the reduction in extraction efficiency due to boarded angular distributions.

43 PARTICLE ACCELERATORS↗

Fast-ions on Alcator C-Mod: Comparisons between Simulation and Experiment for Equilibrium and Evolving Distributions

Analysis of fast-ion distributions >100 T{sub e} is important for both ITER and a fusion reactor, as both will have a significant population of fusion-born alpha particles. Furthermore, energetic ions may display transport properties that differ from the bulk plasma. It is imperative to benchmark current simulation codes with measurements of highly energetic fast-ions on current devices. Experimental measurements of ICRF heated H-minority plasmas on Alcator C-Mod are performed with an upgraded Compact Neutral Particle Analyzer (CNPA). The CNPA consists of vertically-viewing photodiode detectors with viewing chords from r/a = {approx}0.18 to 0.6 and energies from 150 keV to 1.5 MeV. The CNPA measurements are compared to the output of a synthetic diagnostic that has been added to the Fokker-Planck solver CQL3D. CQL3D is coupled with the full-wave solver AORSA to evolve a self-consistent fast-ion distribution. Good agreement is obtained between simulation and experiment for fast ion distributions that are in steady-state (df/dt = 0). However, there are discrepancies between the experimental and simulated results for the time-dependent evolution of the fast-ion distribution. A possible explanation of the discrepancy is due to violation of certain assumptions of quasi-linear theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solving three-body-breakup problems with outgoing-flux asymptotic conditions

An analytically solvable three-body collision system (s wave) model is used to test two different theoretical methods. The first one is a configuration interaction expansion of the scattering wave function using a basis set of Generalized Sturmian Functions (GSF) with purely outgoing flux (CISF), introduced recently in A. L. Frapicinni, J. M. Randazzo, G. Gasaneo, and F. D. Colavecchia [J. Phys. B: At. Mol. Opt. Phys. 43, 101001 (2010)]. The second one is a finite element method (FEM) calculation performed with a commercial code. Both methods are employed to analyze different ways of modeling the asymptotic behavior of the wave function in finite computational domains. The asymptotes can be simulated very accurately by choosing hyperspherical or rectangular contours with the FEM software. In contrast, the CISF method can be defined both in an infinite domain or within a confined region in space. We found that the hyperspherical (rectangular) FEM calculation and the infinite domain (confined) CISF evaluation are equivalent. Finally, we apply these models to the Temkin-Poet approach of hydrogen ionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-I-62: Assessing Radiation Dose Reduction and CT Image Optimization Through the Measurement and Analysis of the Detector Quantum Efficiency (DQE) of CT Images Using Different Beam Hardening Filters

Purpose: Reducing patient dose while maintaining (or even improving) image quality is one of the foremost goals in CT imaging. To this end, we consider the feasibility of optimizing CT scan protocols in conjunction with the application of different beam-hardening filtrations and assess this augmentation through noise-power spectrum (NPS) and detector quantum efficiency (DQE) analysis. Methods: American College of Radiology (ACR) and Catphan phantoms (The Phantom Laboratory) were scanned with a 64 slice CT scanner when additional filtration of thickness and composition (e.g., copper, nickel, tantalum, titanium, and tungsten) had been applied. A MATLAB-based code was employed to calculate the image of noise NPS. The Catphan Image Owl software suite was then used to compute the modulated transfer function (MTF) responses of the scanner. The DQE for each additional filter, including the inherent filtration, was then computed from these values. Finally, CT dose index (CTDIvol) values were obtained for each applied filtration through the use of a 100 mm pencil ionization chamber and CT dose phantom. Results: NPS, MTF, and DQE values were computed for each applied filtration and compared to the reference case of inherent beam-hardening filtration only. Results showed that the NPS values were reduced between 5 and 12% compared to inherent filtration case. Additionally, CTDIvol values were reduced between 15 and 27% depending on the composition of filtration applied. However, no noticeable changes in image contrast-to-noise ratios were noted. Conclusion: The reduction in the quanta noise section of the NPS profile found in this phantom-based study is encouraging. The reduction in both noise and dose through the application of beam-hardening filters is reflected in our phantom image quality. However, further investigation is needed to ascertain the applicability of this approach to reducing patient dose while maintaining diagnostically acceptable image qualities in a clinical setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗