Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONFIGURATION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Magnetic field modeling of a dual-magnet configuration

This paper presents the theoretical and experimental studies of a dual-magnet (DM) configuration that forms the electromagnetic circuit of a nanopositioning actuator. Motivation of this work arises when an accurate prediction of the magnetic field behavior within the DM configuration is required to achieve ultrahigh precision motion control. In the theoretical modeling, the DM configuration is decomposed into several regions where each region is treated as a boundary-value problem. A method, termed superposition of the boundary conditions, is used to obtain the field solution of an air gap that is influenced by two magnetic sources. Consequently, a two-dimensional (2D) analytical model that accurately predicts the magnetic field behavior of the DM configuration is presented. In the experimental investigations, the magnetic flux density measured from a DM configuration prototype is used to validate the accuracy of the 2D analytical model. These experimental data were also compared against the magnetic flux density collected from a conventional single-magnet configuration prototype. Such comparisons verify the claimed features of the DM configuration, i.e., providing 40% increase in the magnetic flux density and offering an evenly distributed magnetic field through the entire air gap of 11 mm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Orion GN and C Data-Driven Flight Software Architecture for Automated Sequencing and Fault Recovery

The Orion Crew Exploration Vehicle (CET) is being designed to include significantly more automation capability than either the Space Shuttle or the International Space Station (ISS). In particular, the vehicle flight software has requirements to accommodate increasingly automated missions throughout all phases of flight. A data-driven flight software architecture will provide an evolvable automation capability to sequence through Guidance, Navigation & Control (GN&C) flight software modes and configurations while maintaining the required flexibility and human control over the automation. This flexibility is a key aspect needed to address the maturation of operational concepts, to permit ground and crew operators to gain trust in the system and mitigate unpredictability in human spaceflight. To allow for mission flexibility and reconfrgurability, a data driven approach is being taken to load the mission event plan as well cis the flight software artifacts associated with the GN&C subsystem. A database of GN&C level sequencing data is presented which manages and tracks the mission specific and algorithm parameters to provide a capability to schedule GN&C events within mission segments. The flight software data schema for performing automated mission sequencing is presented with a concept of operations for interactions with ground and onboard crew members. A prototype architecture for fault identification, isolation and recovery interactions with the automation software is presented and discussed as a forward work item.

King, Ellis↗

Thermal energy storage apparatus, controllers and thermal energy storage control methods

Thermal energy storage apparatus, controllers and thermal energy storage control methods are described. According to one aspect, a thermal energy storage apparatus controller includes processing circuitry configured to access first information which is indicative of surpluses and deficiencies of electrical energy upon an electrical power system at a plurality of moments in time, access second information which is indicative of temperature of a thermal energy storage medium at a plurality of moments in time, and use the first and second information to control an amount of electrical energy which is utilized by a heating element to heat the thermal energy storage medium at a plurality of moments in time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal energy storage apparatus, controllers and thermal energy storage control methods

Thermal energy storage apparatus, controllers and thermal energy storage control methods are described. According to one aspect, a thermal energy storage apparatus controller includes processing circuitry configured to access first information which is indicative of surpluses and deficiencies of electrical energy upon an electrical power system at a plurality of moments in time, access second information which is indicative of temperature of a thermal energy storage medium at a plurality of moments in time, and use the first and second information to control an amount of electrical energy which is utilized by a heating element to heat the thermal energy storage medium at a plurality of moments in time.

Hammerstrom, Donald J.↗

DC current controller for continuously variable series reactor

A direct current controller includes a rectifier configured to convert alternating current input into a direct current output. A converter electrically coupled to the rectifier generates a converted direct current voltage that regulates a converted direct current from the direct current output of the rectifier and synthesizes an ac component of an alternating current grid to counteract an induced back-emf. A direct current controller central controller coupled to the converter regulates the converted direct current.

Wang, Fei (Fred)↗

Investigations on an 0.030-scale space shuttle vehicle configuration 140A/B orbiter model in the Ames Research Center unitary plan 8 by 7-foot supersonic wind tunnel (0A53C)

A wind tunnel test was conducted of an 0.030 scale model of the space shuttle orbiter in a supersonic wind tunnel. Tests were conducted at Mach numbers of 2.5, 3.0, and 3.5. Reynolds numbers ranged from 0.75 million per foot to 4.00 million per foot. The objective of the test was to establish and verify longitudinal and lateral-directional aerodynamic performance, stability, and control characteristics for the configuration 140 A/B SSV Orbiter. Six-component force and moment data, base and cavity pressures, body-flap, elevon, speedbrake, and rudder hinge moments, and vertical tail forces and moments were measured.

Nichols, M. E.↗

DOE 10658 Project Sensitivity-Driven Wide Area Protection (SWAP) Coordination Tools for IBRs

Utilities have seen a rapid increase in solar, wind, and battery energy storage systems that interconnect to their electric system through inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well-known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protects the inverter’s sensitive power electronics devices from damage from conditions such as overcurrent. This results in a low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufacturers and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of focusing on one issue, this report looks broadly at all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspectives from different utility SMEs via questionnaire, the report summarizes the gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

AI-Ready Semantic Infrastructure for CEBAF: From CED to PALS Knowledge Graphs

JLab and PNNL are jointly developing an AI-ready data ecosystem that exposes the Continuous Electron Beam Acceleration Facility’s (CEBAF’s) operational configuration, lattice description, and control-system channels to agentic optimization frameworks through a standards-based semantic layer. The effort integrates the existing facility-specific CEBAF Element Database (CED) with extensions of the emerging facility-agnostic Particle Accelerator Lattice Standard (PALS) to produce a knowledge graph (KG) containing coherent, machine-interpretable views of devices, signals, and regions. With this KG, CEBAF’s setpoints, readbacks, and device hierarchies become queryable using a uniform declarative graph query language (e.g., Neo4j Cypher), providing intents and inspectable semantics suitable for agentic control. The resulting graph-backed interfaces will allow autonomous agents to retrieve authoritative machine configurations, reason over device- and signal-level relationships, and execute tuning and diagnostic workflows without bespoke CEBAF-specific logic, thereby delivering a scalable pathway from operational data to trustworthy agentic accelerator tuning frameworks.

Zhang, He [Thomas Jefferson National Accelerator F↗

Results of investigations (OA20A) on a 0.015-scale 140A/B configuration space shuttle vehicle orbiter model in the NASA/Langley Research Center unitary plan wind tunnel

Data obtained from a wind tunnel test of a 0.015-scale 140A/B configuration SSV orbiter model are presented. This test was conducted with runs at Mach numbers of 2.5, 3.9, and 4.6 for a constant Reynolds number of 2.5 x 1,000,000/foot. Only one model configuration, the complete 140A/B orbiter vehicle, was investigated; various control-surface settings were run through angles-of-attack from -4 to +42 degrees at 0 and +3 degrees of yaw and through angles-of-sideslip from -4 to +6 degrees at 0, +10, +20, and +30 degrees pitch. The purpose of this test was to establish and verify longitudinal and lateral-directional stability and control characteristics for the updated SSV configuration.

Nichols, M. E.↗

Efficient eigenvalue assignment by state and output feedback with applications for large space structures

The erection and deployment of large flexible structures having thousands of degrees of freedom requires controllers based on new techniques of eigenvalue assignment that are computationally stable and more efficient. Scientists at NASA Langley Research Center have developed a novel and efficient algorithm for the eigenvalue assignment of large, time-invariant systems using full-state and output feedback. The objectives of this research were to improve upon the output feedback version of this algorithm, to produce a toolbox of MATLAB functions based on the efficient eigenvalue assignment algorithm, and to experimentally verify the algorithm and software by implementing controllers designed using the MATLAB toolbox on the phase 2 configuration of NASA Langley's controls-structures interaction evolutionary model, a laboratory model used to study space structures. Results from laboratory tests and computer simulations show that effective controllers can be designed using software based on the efficient eigenvalue assignment algorithm.

Vannell, Eric C.↗

Nanotextured Surfaces and Related Methods, Systems, and Uses

A method of controlling wetting characteristics is described. Such method includes forming and configuring nanostructures on a surface where controlling of the wetting characteristics is desired. Surfaces and methods of fabricating such surfaces are also described.

Greer, Harold F.↗

Utility Perspective on Protection Challenges with High IBR Penetration [Slides]

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Investigation of space shuttle orbiter subsonic stability and control characteristics in the NAAL low speed wind tunnel (OA62B), volume 2

Experimental aerodynamic investigations were conducted on a sting-mounted 0.0405 scale representation of the 140A/B space shuttle orbiter in a 7.75 ft by 11 ft low speed wind tunnel during the period from November 14, 1973 to December 6, 1973. Establishment of basic longitudinal stability characteristics in and out of ground effect, and the establishment of lateral-directional stability characteristics in free air were the primary test objectives. The following effects and configurations were tested: (1) two dual podded nacelle configurations; (2) stability and control characteristics at nominal elevon deflections, rudder deflections, airleron deflections, rudder flare angles, and body flap deflections; (3) effects of various elevon and elevon/fuselage gaps on longitudinal stability and control; (4) pressures on the vertical tail at spanwise stations using pressure bugs; (5) aerodynamic force and moment data measured in the stability axis system by an internally mounted, six-component strain gage balance. For Vol. 1, see N74-32324.

Mennell, R.↗

Method and apparatus for controlling pitch and flap angles of a wind turbine

A wind turbine with improved response to wind conditions is provided. Blade flap angle motion is accompanied by a change in pitch angle by an amount defining a pitch/flap coupling ratio. The coupling ratio is non-constant as a function of a flap angle and is preferably a substantially continuous, non-linear function of flap angle. The non-constant coupling ratio can be provided by mechanical systems such as a series of linkages or by configuring electronic or other control systems and/or angle sensors. A link with a movable proximal end advantageously is part of the mechanical system. The system can provide relatively large coupling ratios and relatively large rates of coupling ratio changes especially for near-feather pitches and low flap angles.

17 WIND ENERGY↗

Remote optical wind detection and aerodynamic control system for ground vehicle

An aerodynamic control system for a ground vehicle comprises a LiDAR module including at least one LiDAR sensor configured to obtain wind data upstream of the ground vehicle; a computing device; an aerodynamic device controller; and an aerodynamic device including a control surface. The computing device is configured to receive the wind data from the LiDAR module and generate output signals based on the wind data. The aerodynamic device controller is configured to receive the output signals from the computing device and generate control signals to control the aerodynamic device to adjust aerodynamic properties of the ground vehicle based at least in part the wind data. Changes to the configuration of the control surface may include increasing or decreasing a deflection angle of the at least one aerodynamic device. The aerodynamic device may include, e.g., a pneumatically actuated aerodynamic device or an electro-mechanically actuated aerodynamic device.

Damon, Kenneth H.↗

Experimental Investigation of a 2D Supercritical Circulation-Control Airfoil Using Particle Image Velocimetry

Recent efforts in extreme short takeoff and landing aircraft configurations have renewed the interest in circulation control wing design and optimization. The key to accurately designing and optimizing these configurations rests in the modeling of the complex physics of these flows. This paper will highlight the physics of the stagnation and separation regions on two typical circulation control airfoil sections.

Jones, Gregory S.↗