Predicted and measured temperature compensated surface acoustic wave devices for high-temperature applications

Industrial monitoring and process control, power plants, aerospace industry, military equipment manufacturing, oil and gas industries are examples of businesses in need for high-temperature and harsh environment electronic components and systems. In particular, resonators and filters that operate beyond the 125°C military range upper limit, normally dictated by silicon-based semiconductor devices, are required in applications which demand frequency control, clocking and sensors. In this Letter, temperature compensated surface acoustic wave orientations appropriate for the fabrication of resonators and filters >125°C have been identified through numerical calculations and experimentally confirmed on a commercially available langasite wafer, a piezoelectric crystal which operates at high temperatures. Resonator filters have been designed, fabricated and tested along two orientations, confirming the zero temperature sensitivities at 150 and 300°C. These devices are of great interest for modern harsh environment frequency control, timing and sensor applications.

36 MATERIALS SCIENCE↗

Parallelized Kalman-Filter-Based Reconstruction of Particle Tracks on Many-Core Processors and GPUs

For over a decade now, physical and energy constraints have limited clock speed improvements in commodity microprocessors. Instead, chipmakers have been pushed into producing lower-power, multi-core processors such as Graphical Processing Units (GPU), ARM CPUs, and Intel MICs. Broad-based efforts from manufacturers and developers have been devoted to making these processors user-friendly enough to perform general computations. However, extracting performance from a larger number of cores, as well as specialized vector or SIMD units, requires special care in algorithm design and code optimization. One of the most computationally challenging problems in high-energy particle experiments is finding and fitting the charged-particle tracks during event reconstruction. This is expected to become by far the dominant problem at the High-Luminosity Large Hadron Collider (HL-LHC), for example. Today the most common track finding methods are those based on the Kalman filter. Experience with Kalman techniques on real tracking detector systems has shown that they are robust and provide high physics performance. This is why they are currently in use at the LHC, both in the trigger and offine. Previously we reported on the significant parallel speedups that resulted from our investigations to adapt Kalman filters to track fitting and track building on Intel Xeon and Xeon Phi. Here, we discuss our progresses toward the understanding of these processors and the new developments to port the Kalman filter to NVIDIA GPUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical solution of large scale Hartree–Fock–Bogoliubov equations

The Hartree–Fock–Bogoliubov (HFB) theory is the starting point for treating superconducting systems. However, the computational cost for solving large scale HFB equations can be much larger than that of the Hartree–Fock equations, particularly when the Hamiltonian matrix is sparse, and the number of electrons N is relatively small compared to the matrix size N b . We first provide a concise and relatively self-contained review of the HFB theory for general finite sized quantum systems, with special focus on the treatment of spin symmetries from a linear algebra perspective. We then demonstrate that the pole expansion and selected inversion (PEXSI) method can be particularly well suited for solving large scale HFB equations. For a Hubbard-type Hamiltonian, the cost of PEXSI is at most $\mathcal{O}$(N b 2 ) for both gapped and gapless systems, which can be significantly faster than the standard cubic scaling diagonalization methods. We show that PEXSI can solve a two-dimensional Hubbard-Hofstadter model with N b up to 2.88 × 10 6 , and the wall clock time is less than 100 s using 17 280 CPU cores. Finally, this enables the simulation of physical systems under experimentally realizable magnetic fields, which cannot be otherwise simulated with smaller systems.

97 MATHEMATICS AND COMPUTING↗

Proactive Operations and Investment Planning via Stochastic Optimization to Enhance Power Systems’ Extreme Weather Resilience

We present scalable stochastic optimization approaches for improving power systems’ resilience to extreme weather events. We consider both proactive redispatch and transmission line hardening as alternatives for mitigating expected load shed due to extreme weather, resulting in large-scale stochastic linear programs (LPs) and mixed-integer linear programs (MILPs). We solve these stochastic optimization problems with progressive hedging (PH), a parallel, scenario-based decomposition algorithm. Our computational experiments indicate that our proposed method for enhancing power system resilience can provide high-quality solutions efficiently. With up to 128 scenarios on a 2,000-bus network, the operations (redispatch) and investment (hardening) resilience problems can be solved in approximately 6 min and 2 h of wall-clock time, respectively. Additionally, we solve the investment problems with up to 512 scenarios, demonstrating that the approach scales very well with the number of scenarios. Moreover, the method produces high quality solutions that result in statistically significant reductions in expected load shed. Our proposed approach can be augmented to incorporate a variety of other operational and investment resilience strategies, or a combination of such strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurements of leading neutron production in polarized pp collisions at RHIC-PHENIX

In 2001-2002, we performed an experiment to search for non-zero single transverse spin asymmetry in very forward angle, 0-2.8 mrad, with first polarized pp collision in {radical}(s) = 200 GeV at RHIC, and an unexpected large asymmetry for leading neutron production was discovered. For further investigation, we have measured the cross section with the PHENIX detector in the similar kinematics region. The observed asymmetries are consistent with the previous results measured in an experiment at the 12 o'clock interaction point at RHIC. The measured cross section are consistent with the Feynman-x scaling claimed by the ISR experiments which measured leading neutrons in pp collisions at {radical}(s) = 30.6-62.7 GeV. These cross sections in large Feynman-x, as well as those in ep collisions at HERA experiments, are well described by a pion exchange model. Therefore, the observed large asymmetry for leading neutrons is considered to come from an interference between spin-flip amplitude with the pion exchange and non-flip with Reggeon exchanges.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonlinear effects in the time measurement device based on surface acoustic wave filter excitation

A transversal surface acoustic wave filter has been used as a time interpolator in a time interval measurement device. We are presenting the experiments and results of an analysis of the nonlinear effects in such a time interpolator. The analysis shows that the nonlinear distortion in the time interpolator circuits causes a deterministic measurement error which can be understood as the time interpolation nonlinearity. The dependence of this error on time of the measured events can be expressed as a sparse Fourier series thus it usually oscillates very quickly in comparison to the clock period. The theoretical model is in good agreement with experiments carried out on an experimental two-channel timing system. Using highly linear amplifiers in the time interpolator and adjusting the filter excitation level to the optimum, we have achieved the interpolation nonlinearity below 0.2 ps. The overall single-shot precision of the experimental timing device is 0.9 ps rms in each channel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A fast, direct x-ray detection charge-coupled device

A charge-coupled device (CCD) capable of 200 Mpixels/s readout has been designed and fabricated on thick, high-resistivity silicon. The CCDs, up to 600 {mu}m thick, are fully depleted, ensuring good infrared to x-ray detection efficiency, together with a small point spread function. High readout speed, with good analog performance, is obtained by the use of a large number of parallel output ports. A set of companion 16-channel custom readout integrated circuits, capable of 15 bits of dynamic range, is used to read out the CCD. A gate array-controlled back end data acquisition system frames and transfers images, as well as provides the CCD clocks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The tunneling solutions of the time-dependent Schroedinger equation for a square-potential barrier

The exact tunneling solutions of the time-dependent Schroedinger equation with a square-potential barrier are derived using the continuous symmetry group G{sub S} for the partial differential equation. The infinitesimal generators and the elements for G{sub S} are represented and derived in the jet space. There exist six classes of wave functions. The representative (canonical) wave functions for the classes are labeled by the eigenvalue sets, whose elements arise partially from the reducibility of a Lie subgroup G{sub LS} of G{sub S} and partially from the separation of variables. Each eigenvalue set provides two or more time scales for the wave function. The ratio of two time scales can act as the duration of an intrinsic clock for the particle motion. The exact solutions of the time-dependent Schroedinger equation presented here can produce tunneling currents that are orders of magnitude larger than those produced by the energy eigenfunctions. The exact solutions show that tunneling current can be quantized under appropriate boundary conditions and tunneling probability can be affected by a transverse acceleration.

97 MATHEMATICS AND COMPUTING↗

Multipurpose Compact Spectrometric Unit

A new standalone compact spectrometer was developed. The device consists of analog (peamplifier, amplifier) and digital parts. The digital part is based on the 160 MIPS Digital Signal Processor. It contains 20 Msps Flash-ADC, 1 MB RAM for spectra storage, 128 KB Flash/ROM for firmware storage, Real Time Clock and several voltage regulators providing the power for user peripherals (e.g. amplifier, temperature sensors, etc.). Spectrometer is connected with a notebook via high-speed USB 2.0 bus. The spectrometer is multipurpose device, which is planned to be used for measurements of Rn activities, energy of detected particles by CdTe pixel detector or for coincidence measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in Time Resolved X-ray Excited Optical Luminescence Instrumentation at the Canadian Light Source

Measurement of the optical emission properties of samples excited by x-rays can be used to study defect states in crystals and the optical properties of nanostructured materials. Changes in the intensities, wavelengths and lifetimes of the optical emission can occur when specific core level electrons are excited using tuneable light from a synchrotron light source. At the Canadian Light Source (CLS), collaboration between the user community, the experimental facilities group and the accelerator division has resulted in improved capabilities in the acquisition of Time Resolved XEOL (TRXEOL) data. Using a streak camera, the optical luminescence decay curves from samples excited with 35 ps long synchrotron pulses have been obtained. The streak tube is operated in single sweep mode and is triggered by the 500 MHz RF signal, which has been resynchronized to the orbit clock frequency giving a highly stable trigger pulse. A transverse kicker system is used to improve bunch purity from 10{sup 2} to 10{sup 6}. The decay curves of the XEOL of nanostructured ZnO and a high pressure form of SiO{sub 2} have been measured and demonstrate the unique capabilities of this instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge transfer interactions of a Ru(II) dye complex and related ligand molecules adsorbed on Au(111)

The interaction of the dye molecule, N3 (cis-bis(isothiocyanato)bis(2,2{sup '}-bipyridyl-4,4{sup '}-dicarboxylato) -ruthenium(II)), and related ligand molecules with a Au(111) surface has been studied using synchrotron radiation-based electron spectroscopy. Resonant photoemission spectroscopy (RPES) and autoionization of the adsorbed molecules have been used to probe the coupling between the molecules and the substrate. Evidence of charge transfer from the states near the Fermi level of the gold substrate into the lowest unoccupied molecular orbital (LUMO) of the molecules is found in the monolayer RPES spectra of both isonicotinic acid and bi-isonicotinic acid (a ligand of N3), but not for the N3 molecule itself. Calibrated x-ray absorption spectroscopy and valence band spectra of the monolayers reveals that the LUMO crosses the Fermi level of the surface in all cases, showing that charge transfer is energetically possible both from and to the molecule. A core-hole clock analysis of the resonant photoemission reveals a charge transfer time of around 4 fs from the LUMO of the N3 dye molecule to the surface. The lack of charge transfer in the opposite direction is understood in terms of the lack of spatial overlap between the {pi}*-orbitals in the aromatic rings of the bi-isonicotinic acid ligands of N3 and the gold surface.

36 MATERIALS SCIENCE↗

A low phase noise microwave source for atomic spin squeezing experiments in {sup 87}Rb

We describe and characterize a simple, low cost, low phase noise microwave source that operates near 6.800 GHz for agile, coherent manipulation of ensembles of {sup 87}Rb. Low phase noise is achieved by directly multiplying a low phase noise 100 MHz crystal to 6.8 GHz using a nonlinear transmission line and filtering the output with custom band-pass filters. The fixed frequency signal is single sideband modulated with a direct digital synthesis frequency source to provide the desired phase, amplitude, and frequency control. Before modulation, the source has a single sideband phase noise near -140 dBc/Hz in the range of 10 kHz-1 MHz offset from the carrier frequency and -130 dBc/Hz after modulation. The resulting source is estimated to contribute added spin-noise variance 16 dB below the quantum projection noise level during quantum nondemolition measurements of the clock transition in an ensemble 7 x 10{sup 5} {sup 87}Rb atoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radio frequency-power and the ring-mode to red-mode transition in an inductively coupled plasma

The optical output of an alkali-metal inductively coupled plasma (alkali-ICP) plays an important role in both atomic magnetometers and atomic clocks, producing these devices' atomic signals through optical pumping. Unfortunately, though the alkali-ICP's optical pumping efficiency grows exponentially with temperature, at relatively high temperatures ({approx}140 deg. C) the discharge transitions from ''ring mode'' to ''red mode'', which is a spectral change in the plasma's output that corresponds broadly to a transition from ''good emission'' for optical pumping to ''poor emission.'' Recently, evidence has accumulated pointing to radiation trapping as the mechanism driving the ring-mode to red-mode transition, suggesting that the phenomenon is primarily linked to the alkali vapor's temperature. However, observations of the transition made in the 1960 s, demonstrating that the ICP temperature associated with the transition depended on rf-power, would appear to cast doubt on this mechanism. Here, we carefully investigate the influence of rf-power on the ring-mode to red-mode transition, finding that rf-power only affects the transition through discharge heating. Thus, the present work shows that the primary effect of rf-power on the ring-mode to red-mode transition can be understood in terms of the radiation trapping mechanism.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cryogenic lifetime tests on a commercial epoxy resin high voltage bushing

High-temperature superconducting (HTS) power devices operating in liquid nitrogen frequently require high-voltage bushings to carry the current leads from the superconducting windings to the room temperature grid connections. Oak Ridge National Laboratory is collaborating with Waukesha Electric Systems, SuperPower, and Southern California Edison to develop and demonstrate an HTS utility power transformer. Previous dielectric high voltage tests in support of this program have been carried out in test cryostats with commercial epoxy resin bushings from Electro Composites Inc. (ECI). Though the bushings performed well in these short-term tests, their long-term operation at high voltage in liquid nitrogen needs to be verified for use on the utility grid. Long-term tests are being carried out on a sample 28-kV-class ECI bushing. The bushing has a monolithic cast, cycloaliphatic resin body and is fire- and shatter-resistant. The test cryostat is located in an interlocked cage and is energized at 25 kVac around the clock. Liquid nitrogen (LN) is automatically refilled every 9.5 hours. Partial discharge, capacitance, and leakage resistance tests are periodically performed to check for deviations from factory values. At present, over 2400 hours have been accumulated with no changes in these parameters. The tests are scheduled to run for four to six months.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrarelativistic laser systems based on coherent beam combining

Conceptual design for femtosecond laser system of exawatt class, based on multi-channel amplifier and coherent field combining of petawatt amplifier channels with phase-frequency controlled radiation by optical clock are discussed. The scheme of start petawatt level few-cycle laser system with stable phase-frequency parameters determinated by the accuracy of the optical standard based on parametric amplification in big-size LBO crystals pumped by picosecond pulses is analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new double imaging velocity focusing coincidence experiment: i{sup 2}PEPICO

The vacuum ultraviolet (VUV) beamline of the Swiss Light Source has been upgraded after two years of operation. A new, turntable-type monochromator was constructed at the Paul Scherrer Institut, which allows for fast yaw-alignment as well as quick grating change and exchange. In addition to the original imaging photoelectron photoion coincidence endstation (iPEPICO), a second, complementary double imaging setup (i{sup 2}PEPICO) has been built. Volatile samples can be introduced at room temperature or in a molecular beam, a pyrolysis source allows for radical production, and non-volatile solids can be evaporated in a heated cell. Monochromatic VUV radiation ionizes the sample and both photoelectrons and photoions are velocity map imaged onto two fast position sensitive detectors and detected in delayed coincidence. High intensity synchrotron radiation leads to ionization rates above 10{sup 5} s{sup -1}. New data acquisition and processing approaches are discussed for recording coincidence processes at high rates. The setup is capable of resolving pulsed molecular beam profiles and the synchrotron time structure temporally. The latter is shown by photoelectron autocorrelation, which displays both the 1.04 MHz ring clock frequency as well as resolving the micro-pulses with a separation of 2 ns. Kinetic energy release analysis on the dissociative photoionization of CF{sub 4} indicates a dissociation mechanism change in the Franck-Condon allowed energy range of the first ion state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fully integrated InGaAs/InP single-photon detector module with gigahertz sine wave gating

InGaAs/InP single-photon avalanche diodes (SPADs) working in the regime of GHz clock rates are crucial components for the high-speed quantum key distribution (QKD). We have developed for the first time a compact, stable, and user-friendly tabletop InGaAs/InP single-photon detector system operating at a 1.25 GHz gate rate that fully integrates functions for controlling and optimizing SPAD performance. We characterize the key parameters of the detector system and test the long-term stability of the system for continuous operation of 75 h. The detector system can substantially enhance QKD performance and our present work paves the way for practical high-speed QKD applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A digital optical phase-locked loop for diode lasers based on field programmable gate array

We have designed and implemented a highly digital optical phase-locked loop (OPLL) for diode lasers in atom interferometry. The three parts of controlling circuit in this OPLL, including phase and frequency detector (PFD), loop filter and proportional integral derivative (PID) controller, are implemented in a single field programmable gate array chip. A structure type compatible with the model MAX9382/MCH12140 is chosen for PFD and pipeline and parallelism technology have been adapted in PID controller. Especially, high speed clock and twisted ring counter have been integrated in the most crucial part, the loop filter. This OPLL has the narrow beat note line width below 1 Hz, residual mean-square phase error of 0.14 rad{sup 2} and transition time of 100 {mu}s under 10 MHz frequency step. A main innovation of this design is the completely digitalization of the whole controlling circuit in OPLL for diode lasers.