Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomedical Research”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

The energetics and dynamics of confinement in flexible frameworks and molecular confinement

Porous frameworks form the chemical and structural basis for critical technologies in separations, catalysis, nuclear waste containment and biomedical applications. Hundreds of zeolites and metal organic frameworks (MOFs) have been synthesized, and their ability to separate and store hydrogen, methane and carbon dioxide has been investigated both experimentally and theoretically. Nevertheless, a fundamental and systematic molecular-level understanding of the thermodynamic and structural factors governing the stability and guest-host interactions in these materials lags behind focused studies of specific systems. Because the guest molecules interact with each other and with the host framework, molecular confinement is a finely balanced and complex phenomenon. The ability of the guest molecules to bind and diffuse through the pores is determined by the nature of the host framework which, in turn, responds to the nature and concentration of guest molecules and to pressure and temperature. The work explores how framework flexibility, tailored by structure, composition, temperature and pressure, is a general phenomenon, similar in nature but variable in extent, in both zeolites and MOFs and is part of a free energy landscape in which framework-guest interactions, pressure, and temperature result in changes in framework geometry and, in some cases, phase transitions. These subtle and/or pronounced changes in lattice geometry, energetics, and dynamics can play a decisive role in confinement and in differentiating the binding of molecules of similar size. The free energy landscape created by these structural changes links polymorphism, amorphization, “breathing,” “gate opening” and confinement. Specifically, the generality of such behavior arises from commonalities in lattice dynamics and energetics of frameworks containing a combination of strong rigid bonds and weaker more flexible deformation modes. Identifying and describing these common and collective phenomena is the focus of the research on a selected group of zeolites and MOFs. Structural studies using X-ray and neutron diffraction explore the mechanical functionality of these important materials, specifically how framework materials respond to changes in temperature, pressure and guest loading. These structural studies are combined with calorimetric measurements, using techniques uniquely developed in the participating laboratories, of heats of formation, heat capacities and entropies, and guest-host interactions. The experimental thermodynamic studies are complemented by inelastic neutron scattering studies of the lattice dynamics related both to framework vibrations and to guest-host interactions. The report below summarizes the work done at UC Davis, which is complemented by work done at BYU (Woodfield) and Virginia Tech (Ross).

36 MATERIALS SCIENCE↗

The energetics and dynamics of confinement in flexible frameworks and molecular confinement

Porous frameworks form the chemical and structural basis for critical technologies in separations, catalysis, nuclear waste containment and biomedical applications. Hundreds of zeolites and metal organic frameworks (MOFs) have been synthesized, and their ability to separate and store hydrogen, methane and carbon dioxide has been investigated both experimentally and theoretically. Nevertheless, a fundamental and systematic molecular-level understanding of the thermodynamic and structural factors governing the stability and guest-host interactions in these materials lags behind focused studies of specific systems. Because the guest molecules interact with each other and with the host framework, molecular confinement is a finely balanced and complex phenomenon. The ability of the guest molecules to bind and diffuse through the pores is determined by the nature of the host framework which, in turn, responds to the nature and concentration of guest molecules and to pressure and temperature. The work explores how framework flexibility, tailored by structure, composition, temperature and pressure, is a general phenomenon, similar in nature but variable in extent, in both zeolites and MOFs and is part of a free energy landscape in which framework-guest interactions, pressure, and temperature result in changes in framework geometry and, in some cases, phase transitions. These subtle and/or pronounced changes in lattice geometry, energetics, and dynamics can play a decisive role in confinement and in differentiating the binding of molecules of similar size. The free energy landscape created by these structural changes links polymorphism, amorphization, “breathing,” “gate opening” and confinement. Specifically, the generality of such behavior arises from commonalities in lattice dynamics and energetics of frameworks containing a combination of strong rigid bonds and weaker more flexible deformation modes. Identifying and describing these common and collective phenomena is the focus of the research on a selected group of zeolites and MOFs. Structural studies using X-ray and neutron diffraction explore the mechanical functionality of these important materials, specifically how framework materials respond to changes in temperature, pressure and guest loading. These structural studies are combined with calorimetric measurements, using techniques uniquely developed in the participating laboratories, of heats of formation, heat capacities and entropies, and guest-host interactions. The experimental thermodynamic studies are complemented by inelastic neutron scattering studies of the lattice dynamics related both to framework vibrations and to guest-host interactions. This research was a collaboration between UC Davis (A. Navrotsky) BYU (B. Woodfield) and Virginia Tech (N. Ross).

36 MATERIALS SCIENCE↗

A general framework and review of scatter correction methods in x-ray cone-beam computerized tomography. Part 1: Scatter compensation approaches

Since scattered radiation in cone-beam volume CT implies severe degradation of CT images by quantification errors, artifacts, and noise increase, scatter suppression is one of the main issues related to image quality in CBCT imaging. The aim of this review is to structurize the variety of scatter suppression methods, to analyze the common structure, and to develop a general framework for scatter correction procedures. In general, scatter suppression combines hardware techniques of scatter rejection and software methods of scatter correction. The authors emphasize that scatter correction procedures consist of the main components scatter estimation (by measurement or mathematical modeling) and scatter compensation (deterministic or statistical methods). The framework comprises most scatter correction approaches and its validity also goes beyond transmission CT. Before the advent of cone-beam CT, a lot of papers on scatter correction approaches in x-ray radiography, mammography, emission tomography, and in Megavolt CT had been published. The opportunity to avail from research in those other fields of medical imaging has not yet been sufficiently exploited. Therefore additional references are included when ever it seems pertinent. Scatter estimation and scatter compensation are typically intertwined in iterative procedures. It makes sense to recognize iterative approaches in the light of the concept of self-consistency. The importance of incorporating scatter compensation approaches into a statistical framework for noise minimization has to be underscored. Signal and noise propagation analysis is presented. A main result is the preservation of differential-signal-to-noise-ratio (dSNR) in CT projection data by ideal scatter correction. The objective of scatter compensation methods is the restoration of quantitative accuracy and a balance between low-contrast restoration and noise reduction. In a synopsis section, the different deterministic and statistical methods are discussed with respect to their properties and applications. The current paper is focused on scatter compensation algorithms. The multitude of scatter estimation models will be dealt with in a separate paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-B-210-00: Carson/Zagzebski Distinguished Lectureship

In the last fifteen years, the introduction of plane or diverging wave transmissions rather than line by line scanning focused beams has broken the conventional barriers of ultrasound imaging. By using such large field of view transmissions, the frame rate reaches the theoretical limit of physics dictated by the ultrasound speed and an ultrasonic map can be provided typically in tens of micro-seconds (several thousands of frames per second). Interestingly, this leap in frame rate is not only a technological breakthrough but it permits the advent of completely new ultrasound imaging modes, including shear wave elastography, electromechanical wave imaging, ultrafast doppler, ultrafast contrast imaging, and even functional ultrasound imaging of brain activity (fUltrasound) introducing Ultrasound as an emerging full-fledged neuroimaging modality. At ultrafast frame rates, it becomes possible to track in real time the transient vibrations – known as shear waves – propagating through organs. Such “human body seismology” provides quantitative maps of local tissue stiffness whose added value for diagnosis has been recently demonstrated in many fields of radiology (breast, prostate and liver cancer, cardiovascular imaging, …). Today, Supersonic Imagine company is commercializing the first clinical ultrafast ultrasound scanner, Aixplorer with real time Shear Wave Elastography. This is the first example of an ultrafast Ultrasound approach surpassing the research phase and now widely spread in the clinical medical ultrasound community with an installed base of more than 1000 Aixplorer systems in 54 countries worldwide. For blood flow imaging, ultrafast Doppler permits high-precision characterization of complex vascular and cardiac flows. It also gives ultrasound the ability to detect very subtle blood flow in very small vessels. In the brain, such ultrasensitive Doppler paves the way for fUltrasound (functional ultrasound imaging) of brain activity with unprecedented spatial and temporal resolution compared to fMRI. Combined with contrast agents, our group demonstrated that Ultrafast Ultrasound Localization could provide a first in vivo and non invasive imaging modality at microscopic scales deep into organs. Many of these ultrafast modes should lead to major improvements in ultrasound screening, diagnosis, and therapeutic monitoring. Learning Objectives: Achieve familiarity with recent advances in ultrafast ultrasound imaging technology. Develop an understanding of potential applications of ultrafast ultrasound imaging for diagnosis and therapeutic monitoring. Dr. Tanter is a co-founder of Supersonic Imagine,a French company positioned in the field of medical ultrasound imaging and therapy.

60 APPLIED LIFE SCIENCES↗

SU-D-207B-04: Morphological Features of MRI as a Correlate of Capsular Contracture in Breast Cancer Patients with Implant-Based Reconstructions

Purpose: Capsular contracture (CC) is a serious complication in patients receiving implant-based reconstruction for breast cancer. The goal of this study was to identify image-based correlates of CC using MRI imaging in breast cancer patients who received both MRI and clinical evaluation following reconstructive surgery. Methods: We analyzed a retrospective dataset of 50 patients who had both a diagnostic MR and a plastic surgeon’s evaluations of CC score (Baker’s score) within a six month period following mastectomy and reconstructive surgery. T2w sagittal MRIs (TR/TE = 3500/102 ms, slice thickness = 4 mm) were used for morphological shape features (roundness, eccentricity, solidity, extent and ratio-length) and histogram features (median, skewness and kurtosis) of the implant and the pectoralis muscle overlying the implant. Implant and pectoralis muscles were segmented in 3D using Computation Environment for Radiological Research (CERR) and shape and histogram features were calculated as a function of Baker’s score. Results: Shape features such as roundness and eccentricity were statistically significant in differentiating grade 1 and grade 2 (p = 0.009; p = 0.06) as well as grade 1 and grade 3 CC (p = 0.001; p = 0.006). Solidity and extent were statistically significant in differentiating grade 1 and grade 3 CC (p = 0.04; p = 0.04). Ratio-length was statistically significant in differentiating all grades of CC except grade 2 and grade 3 that showed borderline significance (p = 0.06). The muscle thickness, median intensity and kurtosis were significant in differentiating between grade 1 and grade 3 (p = 0.02), grade 1 and grade 2 (p = 0.03) and grade 1 and grade 3 (p = 0.01) respectively. Conclusion: Morphological shape features described on MR images were associated with the severity of CC. MRI may be important in objectively evaluating outcomes in breast cancer patients who undergo implant reconstruction.

60 APPLIED LIFE SCIENCES↗

Probabilistic Risk Assessment for Astronaut Post Flight Bone Fracture

Introduction: Space flight potentially reduces the loading that bone can resist before fracture. This reduction in bone integrity may result from a combination of factors, the most common reported as reduction in astronaut BMD. Although evaluating the condition of bones continues to be a critical aspect of understanding space flight fracture risk, defining the loading regime, whether on earth, in microgravity, or in reduced gravity on a planetary surface, remains a significant component of estimating the fracture risks to astronauts. This presentation summarizes the concepts, development, and application of NASA's Bone Fracture Risk Module (BFxRM) to understanding pre-, post, and in mission astronaut bone fracture risk. The overview includes an assessment of contributing factors utilized in the BFxRM and illustrates how new information, such as biomechanics of space suit design or better understanding of post flight activities may influence astronaut fracture risk. Opportunities for the bone mineral research community to contribute to future model development are also discussed. Methods: To investigate the conditions in which spaceflight induced changes to bone plays a critical role in post-flight fracture probability, we implement a modified version of the NASA Bone Fracture Risk Model (BFxRM). Modifications included incorporation of variations in physiological characteristics, post-flight recovery rate, and variations in lateral fall conditions within the probabilistic simulation parameter space. The modeled fracture probability estimates for different loading scenarios at preflight and at 0 and 365 days post-flight time periods are compared. Results: For simple lateral side falls, mean post-flight fracture probability is elevated over mean preflight fracture probability due to spaceflight induced BMD loss and is not fully recovered at 365 days post-flight. In the case of more energetic falls, such as from elevated heights or with the addition of lateral movement, the contribution of space flight quality changes is much less clear, indicating more granular assessments, such as Finite Element modeling, may be needed to further assess the risks in these scenarios.

Risk Analysis↗

Predicting error in detecting mammographic masses among radiology trainees using statistical models based on BI-RADS features

Purpose: The purpose of this study is to explore Breast Imaging-Reporting and Data System (BI-RADS) features as predictors of individual errors made by trainees when detecting masses in mammograms. Methods: Ten radiology trainees and three expert breast imagers reviewed 100 mammograms comprised of bilateral medial lateral oblique and craniocaudal views on a research workstation. The cases consisted of normal and biopsy proven benign and malignant masses. For cases with actionable abnormalities, the experts recorded breast (density and axillary lymph nodes) and mass (shape, margin, and density) features according to the BI-RADS lexicon, as well as the abnormality location (depth and clock face). For each trainee, a user-specific multivariate model was constructed to predict the trainee's likelihood of error based on BI-RADS features. The performance of the models was assessed using area under the receive operating characteristic curves (AUC). Results: Despite the variability in errors between different trainees, the individual models were able to predict the likelihood of error for the trainees with a mean AUC of 0.611 (range: 0.502–0.739, 95% Confidence Interval: 0.543–0.680,p < 0.002). Conclusions: Patterns in detection errors for mammographic masses made by radiology trainees can be modeled using BI-RADS features. These findings may have potential implications for the development of future educational materials that are personalized to individual trainees.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-B-210-01: Introduction

In the last fifteen years, the introduction of plane or diverging wave transmissions rather than line by line scanning focused beams has broken the conventional barriers of ultrasound imaging. By using such large field of view transmissions, the frame rate reaches the theoretical limit of physics dictated by the ultrasound speed and an ultrasonic map can be provided typically in tens of micro-seconds (several thousands of frames per second). Interestingly, this leap in frame rate is not only a technological breakthrough but it permits the advent of completely new ultrasound imaging modes, including shear wave elastography, electromechanical wave imaging, ultrafast doppler, ultrafast contrast imaging, and even functional ultrasound imaging of brain activity (fUltrasound) introducing Ultrasound as an emerging full-fledged neuroimaging modality. At ultrafast frame rates, it becomes possible to track in real time the transient vibrations – known as shear waves – propagating through organs. Such “human body seismology” provides quantitative maps of local tissue stiffness whose added value for diagnosis has been recently demonstrated in many fields of radiology (breast, prostate and liver cancer, cardiovascular imaging, …). Today, Supersonic Imagine company is commercializing the first clinical ultrafast ultrasound scanner, Aixplorer with real time Shear Wave Elastography. This is the first example of an ultrafast Ultrasound approach surpassing the research phase and now widely spread in the clinical medical ultrasound community with an installed base of more than 1000 Aixplorer systems in 54 countries worldwide. For blood flow imaging, ultrafast Doppler permits high-precision characterization of complex vascular and cardiac flows. It also gives ultrasound the ability to detect very subtle blood flow in very small vessels. In the brain, such ultrasensitive Doppler paves the way for fUltrasound (functional ultrasound imaging) of brain activity with unprecedented spatial and temporal resolution compared to fMRI. Combined with contrast agents, our group demonstrated that Ultrafast Ultrasound Localization could provide a first in vivo and non invasive imaging modality at microscopic scales deep into organs. Many of these ultrafast modes should lead to major improvements in ultrasound screening, diagnosis, and therapeutic monitoring. Learning Objectives: Achieve familiarity with recent advances in ultrafast ultrasound imaging technology. Develop an understanding of potential applications of ultrafast ultrasound imaging for diagnosis and therapeutic monitoring. Dr. Tanter is a co-founder of Supersonic Imagine,a French company positioned in the field of medical ultrasound imaging and therapy.

60 APPLIED LIFE SCIENCES↗

WE-B-210-03: Closing

In the last fifteen years, the introduction of plane or diverging wave transmissions rather than line by line scanning focused beams has broken the conventional barriers of ultrasound imaging. By using such large field of view transmissions, the frame rate reaches the theoretical limit of physics dictated by the ultrasound speed and an ultrasonic map can be provided typically in tens of micro-seconds (several thousands of frames per second). Interestingly, this leap in frame rate is not only a technological breakthrough but it permits the advent of completely new ultrasound imaging modes, including shear wave elastography, electromechanical wave imaging, ultrafast doppler, ultrafast contrast imaging, and even functional ultrasound imaging of brain activity (fUltrasound) introducing Ultrasound as an emerging full-fledged neuroimaging modality. At ultrafast frame rates, it becomes possible to track in real time the transient vibrations – known as shear waves – propagating through organs. Such “human body seismology” provides quantitative maps of local tissue stiffness whose added value for diagnosis has been recently demonstrated in many fields of radiology (breast, prostate and liver cancer, cardiovascular imaging, …). Today, Supersonic Imagine company is commercializing the first clinical ultrafast ultrasound scanner, Aixplorer with real time Shear Wave Elastography. This is the first example of an ultrafast Ultrasound approach surpassing the research phase and now widely spread in the clinical medical ultrasound community with an installed base of more than 1000 Aixplorer systems in 54 countries worldwide. For blood flow imaging, ultrafast Doppler permits high-precision characterization of complex vascular and cardiac flows. It also gives ultrasound the ability to detect very subtle blood flow in very small vessels. In the brain, such ultrasensitive Doppler paves the way for fUltrasound (functional ultrasound imaging) of brain activity with unprecedented spatial and temporal resolution compared to fMRI. Combined with contrast agents, our group demonstrated that Ultrafast Ultrasound Localization could provide a first in vivo and non invasive imaging modality at microscopic scales deep into organs. Many of these ultrafast modes should lead to major improvements in ultrasound screening, diagnosis, and therapeutic monitoring. Learning Objectives: Achieve familiarity with recent advances in ultrafast ultrasound imaging technology. Develop an understanding of potential applications of ultrafast ultrasound imaging for diagnosis and therapeutic monitoring. Dr. Tanter is a co-founder of Supersonic Imagine,a French company positioned in the field of medical ultrasound imaging and therapy.

60 APPLIED LIFE SCIENCES↗

Radiation Protection and Dosimetry in Medicine - An Overview - Paper 82

In recent years, radiological protection, radiation safety and dosimetry issues have emerged concerning the medical applications of ionizing radiation. Amongst several other issues, the dissemination of the use of Computer Tomography (CT), including for paediatric exams and the growing number of interventional radiology and interventional cardiology procedures have contributed to raise the concerns about the need to more fully justify the medical practices using ionizing radiation and to optimize the protection, reducing the dose to the patients and to the medical staff in the medical applications of ionizing radiation. The importance of implementing the principle of justification in the medical exposures and to further progress in the implementation of the principle of optimization of the protection is of paramount importance for the establishment of a robust international system of radiological protection. The consideration of radiosensitivity issues became mandatory in order to address different issues such as the paediatric CT exposures and the risk of secondary cancer induction in patients years or decades after radiation treatments. Low-dose radiation research also gained a renewed interest in order to overcome longstanding unresolved issues concerning namely the relationship between the radiological risk versus dose in the low dose region characteristic of the medical radiodiagnostic procedures and to shed some light in the mechanisms associated to the biological effects induced by ionizing radiation. Last but not least, the safety of radiotherapy treatments has also driven considerable efforts from the international community of experts, with the aim of reducing the number of incidents and accidents leading to the overexposure of patients to ionizing radiation. In this paper, an overview of the aforementioned topics is provided, considering the international Basic Safety Standards, European Union Directives and national regulations. Views and policies from international organizations such as the IAEA, the WHO and studies and reports from institutions such as the UNSCEAR, ICRP and the NCRP will be conveyed. Recent or ongoing epidemiological studies will be mentioned. Radiological protection and dosimetry of the patient and the workers in the medical applications of ionizing radiation will be discussed. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A distinct subpopulation of membrane vesicles in Pseudomonas putida is enriched in enzymes for lignin catabolism

Bacterial membrane vesicles (MVs) mediate diverse microbial processes and are emerging as powerful biomedical tools, but MV population heterogeneity remains an open question. Here, we separate, enumerate, and characterize two MV populations from the soil bacterium Pseudomonas putida during growth with or without lignin-derived carbon, a major carbon source from plant cells in the rhizosphere. Small MVs (MV-S, diameter ~100 nm) were produced from all cultures, whereas large MVs (MV-L, diameter ~300 nm) were observed during the late stationary phase of lignin cultivations. MV-S contained selectively packaged proteins with diverse physiological functions, whereas the MV-L proteome was smaller and largely enriched in outer membrane proteins. Interestingly, enzymes known to mediate the catabolism of lignin-derived aromatic compounds were enriched in MV-S. Overall, this study highlights the need for careful consideration of MV populations in microbial systems.

59 BASIC BIOLOGICAL SCIENCES↗

Cumulative phase delay imaging - A new contrast enhanced ultrasound modality

Recently, a new acoustic marker for ultrasound contrast agents (UCAs) has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental pressure wave field components is in fact observable for ultrasound propagating through UCAs. This phenomenon is absent in the case of tissue nonlinearity and is dependent on insonating pressure and frequency, UCA concentration, and propagation path length through UCAs. In this paper, ultrasound images based on this marker are presented. The ULA-OP research platform, in combination with a LA332 linear array probe (Esaote, Firenze Italy), were used to image a gelatin phantom containing a PVC plate (used as a reflector) and a cylindrical cavity measuring 7 mm in diameter (placed in between the observation point and the PVC plate). The cavity contained a 240 µL/L SonoVueO{sup ®} UCA concentration. Two insonating frequencies (3 MHz and 2.5 MHz) were used to scan the gelatine phantom. A mechanical index MI = 0.07, measured in water at the cavity location with a HGL-0400 hydrophone (Onda, Sunnyvale, CA), was utilized. Processing the ultrasound signals backscattered from the plate, ultrasound images were generated in a tomographic fashion using the filtered back-projection method. As already observed in previous studies, significantly higher CPD values are measured when imaging at a frequency of 2.5 MHz, as compared to imaging at 3 MHz. In conclusion, these results confirm the applicability of the discussed CPD as a marker for contrast imaging. Comparison with standard contrast-enhanced ultrasound imaging modalities will be the focus of future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-I-01: EIT Imaging to Monitor Human Salivary Gland Functionality: A Feasibility Study

Purpose: Clinically, there exists a need to develop a non-invasive technique for monitoring salivary activity. In this study, we investigate the feasibility of a using the electrical conductivity information from Electrical Impedance Tomography (EIT) to monitor salivary flow activity. Methods: To acquire EIT data, eight Ag/AgCl ECG electrodes were placed around the mandible of the subject. An EIT scan was obtained by injecting current at 50 KHz, 0.4 mA through each pair of electrodes and recording voltage across other electrode pairs. The functional conductivity image was obtained through reconstruction of the voltage data, using Electrical Impedance Tomography and Diffuse Optical Tomography Reconstruction Software (EIDORS) in Matlab. In using EIDORS, forward solution was obtained using a user-defined finite element model shape and inverse solution was obtained using one-step Gaussian solver. EIT scans of volunteer research team members were acquired for three different physiological states: pre-stimulation, stimulation and post-stimulation. For pre-stimulation phase, data were collected in intervals of 5 minutes for 15 minutes. The salivary glands were then stimulated in the subject using lemon and the data were collected immediately. Post-stimulation data were collected at 4 different timings after stimulation. Results: Variations were observed in the electrical conductivity patterns near parotid regions between the pre- and post-stimulation stages. The three images acquired during the 15 minute pre-stimulation phase showed no major changes in the conductivity. Immediately after stimulation, electrical conductivity increased near parotid regions and 15 minutes later slowly returned to pre-stimulation level. Conclusion: In the present study involving human subjects, the change in electrical conductivity pattern shown in the EIT images, acquired at different times with and without stimulation of salivary glands, appeared to be consistent with the change in salivary gland activity. The conductivity changes imaged through EIT are potentially useful for the purpose of salivary monitoring.

60 APPLIED LIFE SCIENCES↗

Attenuation correction in emission tomography using the emission data—A review

The problem of attenuation correction (AC) for quantitative positron emission tomography (PET) had been considered solved to a large extent after the commercial availability of devices combining PET with computed tomography (CT) in 2001; single photon emission computed tomography (SPECT) has seen a similar development. However, stimulated in particular by technical advances toward clinical systems combining PET and magnetic resonance imaging (MRI), research interest in alternative approaches for PET AC has grown substantially in the last years. In this comprehensive literature review, the authors first present theoretical results with relevance to simultaneous reconstruction of attenuation and activity. The authors then look back at the early history of this research area especially in PET; since this history is closely interwoven with that of similar approaches in SPECT, these will also be covered. We then review algorithmic advances in PET, including analytic and iterative algorithms. The analytic approaches are either based on the Helgason–Ludwig data consistency conditions of the Radon transform, or generalizations of John’s partial differential equation; with respect to iterative methods, we discuss maximum likelihood reconstruction of attenuation and activity (MLAA), the maximum likelihood attenuation correction factors (MLACF) algorithm, and their offspring. The description of methods is followed by a structured account of applications for simultaneous reconstruction techniques: this discussion covers organ-specific applications, applications specific to PET/MRI, applications using supplemental transmission information, and motion-aware applications. After briefly summarizing SPECT applications, we consider recent developments using emission data other than unscattered photons. In summary, developments using time-of-flight (TOF) PET emission data for AC have shown promising advances and open a wide range of applications. These techniques may both remedy deficiencies of purely MRI-based AC approaches in PET/MRI and improve standalone PET imaging.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nuclear Materials Packaging, Transportation, and Systems Analysis Group Software Quality Assurance Plan: ANSYS Mechanical Finite Element Analysis Software Version 2023R1

ANSYS Inc. develops and markets engineering simulation software and services used in the aerospace, automotive, manufacturing, electronics, biomedical, energy, defense, and many other industries. ANSYS is dedicated to engineering simulation and is the world’s leading software provider. ANSYS was founded in 1970 and is headquartered in Canonsburg, Pennsylvania. ANSYS provides an engineering analysis tool combining structural, thermal, computational fluid dynamics, acoustic, and electromagnetic simulation capabilities. ANSYS has two main programs, which use the same solvers: (1) Mechanical APDL (ANSYS Design Parametric Language), a Fortran-based coding platform, and (2) ANSYS Workbench, which uses a graphical user interface to aid in finite element analysis implementation. This plan covers both APDL and Workbench. The ANSYS computer program is a large-scale, multipurpose finite element program that can be used to solve several classes of engineering analyses. The analysis capabilities of ANSYS include the ability to solve static and dynamic structural analyses, steady-state and transient heat transfer problems, mode-frequency and buckling eigenvalue problems, static or time-varying magnetic analyses, and various types of field and coupled-field applications. The program contains many special features that allow nonlinearities or secondary effects such as plasticity, large strain, hyperelasticity, creep, swelling, large deflections, contact, stress stiffening, temperature dependency, material anisotropy, and radiation to be included in the solution. As ANSYS has been developed, other special capabilities such as substructuring, submodeling, random vibration, kinetostatics, kinetodynamics, free convection fluid analysis, acoustics, magnetics, piezoelectrics, coupled-field analysis, and design optimization have been added to the program. These capabilities contribute further to making ANSYS a multipurpose analysis tool for varied engineering disciplines. The ANSYS program has been in commercial use for over 50 years and has been used extensively in the aerospace, automotive, construction, electronic, energy services, manufacturing, nuclear, plastics, oil, and steel industries. Additionally, many consulting firms and hundreds of universities have used ANSYS for analysis, research, and educational purposes. ANSYS is recognized worldwide as one of the most widely used and capable programs of its type. Ansys design analysis software is the first created within a quality system with ISO 9001 certification, the internationally accepted quality standard. Product development, testing, maintenance and support processes also meet the United States Nuclear Regulatory Commission's quality requirements, as they have for nearly four decades. The Quality Assurance Service Agreement is suitable for the customers working in the nuclear industry who need to meet specific federal regulations including 10CRF50 Appendix B and provisions of 10CFR21. ANSYS has retained its original International Organization for Standardization (ISO) 9001 accreditation certificate since1995-05-04, It’s current certificate is valid until 2027-05-29.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-T-59: The Effect of Radiotherapy Dose On Immunoadjuvants

Purpose: Combining radiotherapy with immunotherapy is a promising approach to enhance treatment outcomes for cancer patients. This in-vitro study investigated which radiotherapy doses could adversely affect the function of anti-CD40 mAb, which is one of the key immunoadjuvants under investigations for priming such combination therapy. Methods: Human monocyte derived THP-1 cells were treated with 100ng/mL of PMA in chamber slides to differentiate into macrophage. The THP-1 differentiated macrophages were treated with 2uL/ml of the anti-CD40 mAb and incubated at 37°C and 5% CO2 for 24 hours. Anti-CD40 mAb treated cells were then irradiated at different doses of x-rays: (0, 2, 4, 6, 8, and 12) Gy using the Small Animal Radiotherapy Research Platform (SARRP). After radiation, the cells were left at 4°C for 2 hours followed by immunofluorescence assay. A Nikon inverted live-cell imaging system with fluorescence microscope was used to image the cells mounted on a slide fixed with Dapi. For comparison, an ELISA assay was performed with the antibody added to 3mL of PBS in multiple 10mm dishes. The 10mm dishes were irradiated at different x-ray dose: (0, 2, 4, 6, 8. 10, 12, and 15) Gy using the SARRP. Results: The anti-CD40 mAb activating the macrophages starts to lose their viability due to radiation dose between 8Gy to 12Gy as indicated by the immunofluorescence assay. The ELISA assay, also indicated that such high doses could lead to loss of the mAb’s viability. Conclusion: This work suggests that high doses like those employed during Stereotactic Ablative Radiotherapy may affect the viability of immunoadjuvants such as anti-CD 40. This study avails in-vivo experiments combining radiotherapy with anti-cd40 to get synergistic outcomes, including in the treatment of metastatic disease.

60 APPLIED LIFE SCIENCES↗

Biological Data for Deep Space Mission Support

Increased biomedical risks and challenges associated with deep space missions (cis-Lunar, Mars transit, Mars surface) require new knowledge discovery and development of novel ecosystem and biomedical support capabilities. This paradigm shift supporting distant and long-duration missions requires biological data to be findable, accessible, interoperable, reusable (FAIR), and maximally open-access (i.e., there is a data governance continuum from closed to mediated to embargoed to open). The NASA “Open Science Data Repositories” (OSDR) aims to meet scientific, technical, and operational spaceflight needs, and offers the ability to upload, download, search, share, analyze, and visualize data across physiological, behavioral, ‘omics, and environmental monitoring telemetry datasets. OSDR includes NASA GeneLab, NASA Ames Life Sciences Data Archive (ALSDA), and NASA Biological Institutional Scientific Collection (NBISC). In the past year, ALSDA has undergone a transformation in its data collection, curation, and architecture methods. Standardizing non-genomic (phenotypic) datasets was, and will continue to be, a challenge because of their diverse nature (e.g., molecular, cellular, tissue, whole organism behavior; micro-computed tomography, intraocular pressure, fluorescence microscopy, western blot, ultrasonography; tabular, images, video). This year ALSDA, alongside GeneLab, introduced the Biological Data Management Environment (BDME) with the purpose to accept submission of data from space relevant experiments including spaceflight, radiation, simulated gravity, gravitropism, isolation and confinement, hostile closed environments and/or distance from Earth. In addition to bringing together omics, phenotypic, physiological, bioimaging, and behavioral data into one repository. By integrating with GeneLab a multi-project submission portal aims to reduce the burden on PIs submitting data and enabling the discovery of both omics and phenotypic data. The purpose of ALSDA is to collect, curate, and make all non-human space-relevant biological data maximally findable, accessible, interoperable, and reusable (FAIR). These scope of ALSDA data collected and submitted by PIs include study design metadata, subject metadata, assay metadata (parameters), raw and processed assay data, assay imagery/video, and subject-experienced mission data telemetry (radiation, temperature, humidity, acoustics, vibrations, etc.). In 2021, a community of researchers rallied to form the ALSDA Analysis Working Group (AWG) and provided scientific consensus on dataset sample and assay metadata. The community and excitement around the ALSDA/OSDR system has already led to several data reuse studies, demonstrating value using machine learning (ML), knowledge graphs, and meta-analysis approaches.

space biology↗

Biological Data for Deep Space Mission Support

Increased biomedical risks and challenges associated with deep space missions (cis-Lunar, Mars transit, Mars surface) require new knowledge discovery and development of novel ecosystem and biomedical support capabilities. This paradigm shift supporting distant and long-duration missions requires biological data to be findable, accessible, interoperable, reusable (FAIR), and maximally open-access (i.e., there is a data governance continuum from closed to mediated to embargoed to open). The NASA “Open Science Data Repositories” (OSDR) aims to meet scientific, technical, and operational spaceflight needs, and offers the ability to upload, download, search, share, analyze, and visualize data across physiological, behavioral, ‘omics, and environmental monitoring telemetry datasets. OSDR includes NASA GeneLab, NASA Ames Life Sciences Data Archive (ALSDA), and NASA Biological Institutional Scientific Collection (NBISC). In the past year, ALSDA has undergone a transformation in its data collection, curation, and architecture methods. Standardizing non-genomic (phenotypic) datasets was, and will continue to be, a challenge because of their diverse nature (e.g., molecular, cellular, tissue, whole organism, behavior; micro-computed tomography, intraocular pressure, fluorescence microscopy, western blot, ultrasonography; tabular, images, video). This year ALSDA, alongside GeneLab, introduced the Biological Data Management Environment (BDME) with the purpose to accept submission of data from space relevant experiments including spaceflight, radiation, simulated gravity, gravitropism, isolation and confinement, hostile closed environments and/or distance from Earth. In addition to bringing together omics, phenotypic, physiological, bioimaging, and behavioral data into one repository. By integrating with GeneLab a multi-project submission portal aims to reduce the burden on PIs submitting data and enabling the discovery of both omics and phenotypic data. The purpose of ALSDA is to collect, curate, and make all non-human space-relevant biological data maximally findable, accessible, interoperable, and reusable (FAIR). These scope of ALSDA data collected and submitted by PIs include study design metadata, subject metadata, assay metadata (parameters), raw and processed assay data, assay imagery/video, and subject-experienced mission data telemetry (radiation, temperature, humidity, acoustics, vibrations, etc.). In 2021, a community of researchers rallied to form the ALSDA Analysis Working Group (AWG) and provided scientific consensus on dataset sample and assay metadata. The community and excitement around the ALSDA/OSDR system has already led to several data reuse studies, demonstrating value using machine learning (ML), knowledge graphs, and meta-analysis approaches.

space biology↗