Optical field-enhancement in metal nanoparticle arrays contacted by electron beam induced deposition

We study the impact of optical field-enhancement effects on the optoelectronic properties of metal nanoparticle arrays. Applying a focused ion beam lithography in combination with an electron beam induced deposition technique we pattern electrical contacts in a way that they give rise to an electromagnetic field-enhancement. The field-enhancement is directly observed in an enhanced photoconductance of the arrays. Finite-difference time-domain simulations verify that an antenna effect is responsible for the observed increase in the photoconductance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

(abstract) Optical Scattering and Surface Microroughness of Ion Beam Deposited Au and Pt Thin Films

Thin films of gold and platinum have been deposited onto superpolished fused silica substrates using thermal evaporation, ion assisted deposition (IAD), and ion assisted sputtering. The influence of ion beam flux, thin film material, and deposition rate on the films microroughness have been investigated. Short range surface microroughness of the films has been examined using scanning tunneling microscopy (STM) and atomic force microscopy (AFM). Long range surface microroughness has been characterized using an angle resolved optical scatterometer. Results indicate that ion beam deposited coatings have improved microstructure over thermally evaporated films.

assisted sputtering fused silica ion beam microrou↗

Parallel multiplex laser feedback interferometry

We present a parallel multiplex laser feedback interferometer based on spatial multiplexing which avoids the signal crosstalk in the former feedback interferometer. The interferometer outputs two close parallel laser beams, whose frequencies are shifted by two acousto-optic modulators by 2Ω simultaneously. A static reference mirror is inserted into one of the optical paths as the reference optical path. The other beam impinges on the target as the measurement optical path. Phase variations of the two feedback laser beams are simultaneously measured through heterodyne demodulation with two different detectors. Their subtraction accurately reflects the target displacement. Under typical room conditions, experimental results show a resolution of 1.6 nm and accuracy of 7.8 nm within the range of 100 μm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-Modulation-Driven X-Ray Pulse Shaping in Regenerative Amplifier Free-Electron Lasers

In this Letter, we present a robust method for generating custom-shaped, coherent hard x-ray pulses in regenerative amplifier free-electron lasers (RAFELs) using laser-induced energy modulation of the electron beam. A temporally shaped optical modulation imprints an optical-wavelength energy pattern on the beam, which interacts with the recirculated seed in the x-ray cavity to generate spectral sidebands. These sidebands lie outside the Bragg reflection bandwidth and are extracted as out-coupled radiation, while the seed is retained for continued amplification, enabling a novel mechanism for both output coupling and pulse shaping. Furthermore, this approach allows deterministic control over the spectral and temporal properties of the emitted x-rays, including multicolor generation, twin-pulse structures, pulse duration tuning, and complex temporal waveforms. Importantly, it does not require modification of the RAFEL cavity or optics and is fully compatible with high-repetition-rate operation, offering a practical pathway to deliver coherent, shaped, and on-demand x-ray pulses for advanced time-resolved and nonlinear x-ray science.

Free-electron lasers↗

Estimates of Damped Energy Spread and Emittance in a Two Energy Storage Ring Cooler

In this paper we provide estimates of the damped energy spread and emittance in a two-energy storage ring cooler. Two energy storage rings have two loops at markedly different energies, one at low energy and the other at high energy. In a cooling application the low energy ring has a cooling section to cool the ion beam and the high energy ring may have a wiggler section to enhance the damping effect on electron beam. The linear optics in the cooling section is designed to attain the maximum cooling of ion beams. Similarly, the linear optics in the wiggler section is designed to attained the required equilibrium emittance and energy spread. Hence, the radiation events in these two rings are different and independent. Since the values of damped energy spread and emittance depend on a range of parameters related to lattice design and rings energies, we present analytical calculations along with simulation results to estimate the values of damped energy spread and emittance in a two energy storage ring cooler.

Dhital, B.↗

Optical and structural characterization of GaN thin films at different N to Ga flux ratios

GaN films were grown on Si(111) substrates under various beam equivalent pressure (BEP) ratios by plasma-assisted molecular beam epitaxy. The optical properties for the grown samples were studied over a wide spectral range from 200 to 3300 nm using the reflectance spectrum only. It was found that increasing the N/Ga BEP ratio from 17.9 to 46.1 increases the refractive index (n) from 2.05 to 2.38 at wavelength 630 nm (for example), while the optical energy gap (E{sub g}) were found to be in the range between 3.325 to 3.35 eV with no specific trend. The structural properties for the grown films were studied through two types of rocking curve measurements; normal rocking curve ({omega}-scan) and triple axis rocking curve ({omega}/2{theta}-scan). It was found that with decreasing the N/Ga ratio from 46.1 to 17.9 the full width at half maximum decreases from 0.62 deg. to 0.58 deg. for {omega}-scan and from 0.022 deg. to 0.021 deg. for {omega}/2{theta}-scan. Thus, our results showed a clear correlation between the optical-structural parameters and the BEP ratios of N and Ga.

36 MATERIALS SCIENCE↗

Effect of interfacial roughness correlation on diffuse scattering intensity in a neutron supermirror

Neutron supermirrors are increasingly important devices for transporting, bending, and focusing neutron beams. Reflected neutrons from a supermirror are divided into specular and off-specular (diffuse) components. Suppression of the diffuse component is important since it reduces the signal-to-noise ratio, a serious problem when a supermirror is used in a focusing system for purposes such as small angle scattering measurements. The diffuse intensity can be decreased by more than one order of magnitude by adopting NiC/Ti multilayers instead of conventional Ni/Ti multilayers. In order to obtain insight into the mechanism that controls the diffuse intensity from a supermirror, the crystal structure of Ni and NiC monolayers and the interface structure of Ni/Ti and NiC/Ti multilayers were investigated. The crystallite size in the NiC monolayer was found to be smaller than that in the Ni monolayer by a factor of 4.1 by x-ray diffraction measurement. The interface structure of the Ni/Ti and NiC/Ti multilayers was observed by neutron reflectivity and diffuse intensity measurements. For the NiC/Ti multilayer, the lateral correlation length was smaller by a factor of 3.6 than for the Ni/Ti multilayer, whereas the vertical correlation length was greater by a factor exceeding 25. Diffuse intensity calculations based on the distorted wave Born approximation revealed that these differences explain the difference between the diffuse intensity of the Ni/Ti and NiC/Ti supermirrors. This study demonstrated that a multilayer with a large vertical correlation length and a small lateral correlation length effectively suppresses the diffuse intensity from a supermirror.

36 MATERIALS SCIENCE↗

Test Study for Generation of Short Pulsed Synchrotron Radiation by Kicker Magnet in SPring-8 Storage Ring

A shorter pulse of synchrotron radiation is desired to measure a fast dynamic process exploration with a better resolution by material structure physics users. Among many complex schemes proposed for this purpose, we tested a simple scheme which makes use of a head-tail oscillation of a circulating electron beam with a small beam emittance. We have developed a new kicker magnet system which generated a short pulsed horizontal field of about 4.19 mT in 1.4 {mu}s pulse width with 1 Hz repetition. With this new developed kicker magnet system, we observed a bunch profile which leaned impressively between head and tail position by a visible light streak camera. Then we succeeded in achieving the shorter X-ray pulse width than the original one after a vertical slit being sliced by {approx}6 times. The observed X-ray pulse width was 7.38{+-}2.35 ps in FWHM.

43 PARTICLE ACCELERATORS↗

Beam Imaging of a High-Brightness Elliptic Electron Gun

An innovative research program is being carried out to experimentally demonstrate a high-brightness, space-charge-dominated elliptic electron beam using a non-axisymmetric permanent magnet focusing system. Results of the fabrication, initial testing and beam imaging of an elliptic electron gun are reported.

43 PARTICLE ACCELERATORS↗

X-Ray And Polarized Neutron Reflectometry: Characterization Of Si/Co/Si And Si/Ni/Si Systems

Technologically important metal silicides formed through interdiffusion in metal/Si systems has been probed using two complementary techniques viz. x-ray reflectivity (XRR) and polarized neutron reflectivity (PNR). Both structural and magnetic characterization with good depth resolution has been achieved in these systems. We have studied two systems Si/Co/Si and Si/Ni/Si which relate to important applications in ferromagnetic/ non-magnetic semiconductor layered structures for memory devices.

36 MATERIALS SCIENCE↗

Laser induced bubbles inside liquids: Transient optical properties and effects on a beam propagation

Light transmission through a laser formed bubble (LFB) following ablation of a metallic target inside water was studied. During the early expansion and late collapsing phases, the refraction index n{sub b} of the hot high-pressure vapor bubble is higher than 1.23 and close to that of the surrounding liquid. The cavity growth lowers n{sub b} down to 1.00 and causes strong defocusing of the incident laser beam with consequent enlargement of the ablation crater diameter, here overcoming factor two. Inhomogeneous water vapor clustering inside the cool expanded bubble further perturbs the light transmission and induces irregular ablation by the successive laser pulse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-C-201-07: Towards Clinical Cherenkov Emission Dosimetry: Stopping Power-To-Cherenkov Power Ratios and Beam Quality Specification of Clinical Electron Beams

Purpose: We propose a Cherenkov emission (CE)-based reference dosimetry method, which in contrast to ionization chamber-based dosimetry, employs spectrum-averaged electron restricted mass collision stopping power-to-Cherenkov power ratios (SCRs), and we examine Monte Carlo-calculated SCRs and beam quality specification of clinical electron beams. Methods: The EGSnrc user code SPRRZnrc was modified to compute SCRs instead of stopping-power ratios (single medium: water; cut-off: CE threshold (observing Spencer-Attix conditions); CE power: Frank-Tamm). SCRs are calculated with BEAMnrc for realistic electron beams with nominal energies of 6–22 MeV from three Varian accelerators (TrueBeam Clinac 21EX, Clinac 2100C/D) and for mono-energetic beams of energies equal to the mean electron energy at the water surface. Sources of deviation between clinical and mono-energetic SCRs are analyzed quantitatively. A universal fit for the beam-quality index R{sub 50} in terms of the depth of 50% CE C{sub 50} is carried out. Results: SCRs at reference depth are overestimated by mono-energetic values by up to 0.2% for a 6-MeV beam and underestimated by up to 2.3% for a 22-MeV beam. The variation is mainly due to the clinical beam spectrum and photon contamination. Beam angular spread has a small effect across all depths and energies. The influence of the electron spectrum becomes increasingly significant at large depths, while at shallow depths and high beam energies photon contamination is predominant (up to 2.0%). The universal data fit reveals a strong linear correlation between R{sub 50} and C{sub 50} (ρ > 0.99999). Conclusion: CE is inherent to radiotherapy beams and can be detected outside the beam with available optical technologies, which makes it an ideal candidate for out-of-beam high-resolution 3D dosimetry. Successful clinical implementation of CE dosimetry hinges on the development of robust protocols for converting measured CE to radiation dose. Our findings constitute a key step towards clinical CE dosimetry.

60 APPLIED LIFE SCIENCES↗

Brightness-voltage characteristics of ZnS:Mn luminescent films

Brightness-voltage characteristics, the voltage dependence of the luminous efficiency, and the photoluminescence spectra of ZnS:Mn luminescent films produced by thermal and electron-beam evaporation have been studied. Specific features of their properties are attributed to differences in excitation processes of activator centers related to the structural states of the layers.

36 MATERIALS SCIENCE↗

Prospects for atomic frequency standards

The potentialities of different atomic frequency standards which are not yet into field operation, for most of them, but for which preliminary data, obtained in laboratory experiments, give confidence that they may improve greatly the present state of the art are described. The review will mainly cover the following devices: (1) cesium beam frequency standards with optical pumping and detection; (2) optically pumped rubidium cells; (3) magnesium beam; (4) cold hydrogen masers; and (5) traps with stored and cooled ions.

Audoin, C.↗