Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Compact Dielectric Wall Accelerator Development For Intensity Modulated Proton Therapy And Homeland Security Applications

Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, SiC photoconductive switches and compact proton sources. Applications of the DWA accelerator to problems in homeland security will also be discussed.

43 PARTICLE ACCELERATORS↗

Archimedes Brought to Light

Just over 100 years ago in the summer of 1906, a Danish scholar called Johan Ludvig Heiberg travelled to the famous Metochion library of the Church of the Holy Sepulcher in Constantinople. He had got wind of an intriguing medieval prayer book that had recently been found at the library, and which contained a series of Christian prayers written on parchment recycled from older books. But underneath the scrawlings of a 13th-century medieval monk, the battered manuscript also appeared to contain some strange Greek writing as well as mysterious drawings and mathematical symbols. When Heiberg saw the book, he soon realized that the hidden material in fact contained the thoughts of Archimedes of Syracuse (287-212 BC) - one of the greatest thinkers of the ancient world. It was in November 2003, while on my way to a conference in Germany, that I first realized that the technique might help to uncover the hidden writings in the Archimedes Palimpsest. I had been reading an article in the German magazine GEO about the manuscript and, having previously used X-rays to detect metals in biological systems, realized that XRF could help to detect iron and other common elements in the ink. I immediately e-mailed Abigail Quandt, a conservator at the Walters Art Museum, who was part of a team that had been put in charge of the Archimedes manuscript. I was delighted to find that the team, led by her colleague William Noel, was looking for new ways to study this ancient book. Indeed, it turned out that two other researchers - Gene Hall from Rutgers University and Bob Morton from the oil firm ConocoPhillips - had also suggested using XRF imaging. Another team member - Johns Hopkins University physicist Bill Christens-Barry - had already been thinking of using X-rays too. In March 2004 Hall and the team carried out the first tests on the Palimpsest using X-rays from a commercial generator. Although these tests were promising, the results confirmed my belief that synchrotron radiation could be much better because it would allow the book to be scanned much faster and with higher resolution. Indeed, I had already begun collaborating with my SLAC colleague Martin George, who helped to develop an XRF system that could image and scan the Palimpsest at high speed. It consisted of a computer-controlled stage that could hold a single leaf from the book and be moved from side to side so that the X-ray beam from SLAC's powerful SPEAR3 accelerator could be scanned across the sample. A 2D image of the page could then be built up by plotting the intensity of the fluorescent X-rays at a particular energy. The problem with imaging a delicate object like the Palimpsest using intense beams of X-rays is that it can be damaged if exposed for too long. Working with Gregory Young from the Conservation Institute in Ottawa, Canada, we carried out tests on a piece of parchment from a will written in 1870 that had been given to us by Quandt at the Walters Art Museum from her private collection. We found that if the parchment is moved sufficiently quickly so that the beam dwells for no longer than 0.1 s on every area through which it is passing, then no measurable damage occurs to the document's fibers. The only snag was that when the beam reached the edges of a particular line of the document, the stage holding the individual pages had to stop briefly and step down to the next line - a process that could take as long as 1 s. To avoid overexposure during these stops, we added a fast pneumatic beam shutter to the computerized scanning system, which remained open only when the parchment was moving. Our tests at SLAC proved so successful that we were able to persuade the Archimedes team to let us use our equipment on the real Palimpsest. The team arrived in May 2005 with 3 test pages and we were soon able to image half of one page at a resolution of 250 dots per centimeter in just 30 hours (Nature 435 257). We then used algorithms developed by Keith Knox, a physicist from Boeing, to convert the raw data into 2D images. In all of our measurements we were most interested in the fluorescence from iron, which is the most common element in the ink. But by placing suitable electronic 'windows' on the detector, we were able to simultaneously also record the signal from other elements, including calcium, zinc, barium and copper. The iron XRF image clearly revealed Archimedes writing under one of the forged paintings that had been added in the 20th century and - in the next two runs during March and August last year - we were able to scan various texts that could not be revealed with other techniques as well as some writings that do not appear anywhere else. By installing better detectors and by including a new readout system that had been developed by our colleague Alex Garachtchenko, we can now scan a whole page in just 12 hours with the X-ray beam sweeping over each 40 {micro}m2 area of the sample in just 3 ms.

43 PARTICLE ACCELERATORS↗

LaserNetUS at the Extreme Light Laboratory

This is the final report for LaserNetUS, Grant # DE-SC0019419. This project covered the first two annual cycles (2018-2020) of LaserNetUS experiments conducted at the Extreme Light Laboratory, University of Nebraska-Lincoln. The project provided students and scientists from four institutions (BYU, Stanford, UNR, and ARFL) with access to a world-class high-intensity laser facility. Experimental results were obtained on the topics of Nonlinear Thomson scattering, Relativistic vacuum acceleration, and electrons beams in relativistic high-energy-density plasma to study x-ray line emission and radio frequencies of ultrashort relativistic electron beam interactions. Another benefit was the training of 10 students (undergraduate or graduate) and 6 young scientists (postdocs or associate/research professors) in areas that are key to the future development of high energy density science and high-power laser technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LaserNetUS at the Extreme Light Laboratory. Final report

This is the final report for LaserNetUS, Grant # DE-SC0019419. This project covered the first two annual cycles (2018-2020) of LaserNetUS experiments conducted at the Extreme Light Laboratory, University of Nebraska-Lincoln. The project provided students and scientists from four institutions (BYU, Stanford, UNR, and ARFL) with access to a world-class high-intensity laser facility. Experimental results were obtained on the topics of Nonlinear Thomson scattering, Relativistic vacuum acceleration, and electron beams in relativistic high-energy-density plasma to study x-ray line emission and radio frequencies of ultrashort relativistic electron beam interactions. Another benefit was the training of 10 students (undergraduate or graduate) and 6 young scientists (postdoc or associate/research professors) in critical areas to the future development of high energy density science and high-power laser technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deviated plane varied line-space grating spectrograph

The limit of resolution for the planar varied line-space grating in a converging beam can be found by analyses of the optical path errors. The errors may be canceled by slight deviations of the planar substrate surface. The cancellation of the path errors leads to a markedly improved spectral resolution. The surface figure for an improved resolution deviated planar varied line-space grating spectrograph is shown. Ray-tracing of this improved spectrograph shows substantial gains in spectral performance.

Edelstein, Jerry↗

High-resolution CCD imagers using area-array CCD's for sensing spectral components of an optical line image

CCD imagers with a novel replicated-line-imager architecture are abutted to form an extended line sensor. The sensor is preceded by optics having a slit aperture and having an optical beam splitter or astigmatic lens for projecting multiple line images through an optical color-discriminating stripe filter to the CCD imagers. A very high resolution camera suitable for use in a satellite, for example, is thus provided. The replicated-line architecture of the imager comprises an area-array CCD, successive rows of which are illuminated by replications of the same line segment, as transmitted by respective color filter stripes. The charge packets formed by accumulation of photoresponsive charge in the area-array CCD are read out row by row. Each successive row of charge packets is then converted from parallel to serial format in a CCD line register and its amplitude sensed to generate a line of output signal.

Elabd, Hammam↗

Note: Spectrometer with multichannel photon-counting detector for beam emission spectroscopy in magnetic fusion devices

A spectrometer based on a linear array photomultiplier tube (PMT) has been developed and calibrated. A 0.635 m focal length Czerny-Turner monochromator combined with a coupling optics provides an image of a narrow 0.5 nm spectral range with a resolution of 0.015 nm/channel on a 32-anode PMT. The system aims at spectroscopy of D{sub α} or H{sub α} lines emitted by a diagnostic atomic beam in a plasma (primarily a motional Stark effect diagnostics). To record a low photon flux of ∼10{sup 6} s{sup −1} per channel with the time resolution of 100 μs, a pulse counting approach has been used. Wideband amplifiers scale single-electron pulses and transmit them to a digital data processing core hardwired in a programmable logic matrix. Calibrations have shown that the aberration-limited instrument function fits to a single detector channel of 1 mm width. Pilot results of passive measurements of D{sub α} light emission from the plasma confined in a magnetic trap are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam dynamics simulations of post low energy beam transport section in RAON heavy ion accelerator

RAON (Rare isotope Accelerator Of Newness) heavy ion accelerator of the rare isotope science project in Daejeon, Korea, has been designed to accelerate multiple-charge-state beams to be used for various science programs. In the RAON accelerator, the rare isotope beams which are generated by an isotope separation on-line system with a wide range of nuclei and charges will be transported through the post Low Energy Beam Transport (LEBT) section to the Radio Frequency Quadrupole (RFQ). In order to transport many kinds of rare isotope beams stably to the RFQ, the post LEBT should be devised to satisfy the requirement of the RFQ at the end of post LEBT, simultaneously with the twiss parameters small. We will present the recent lattice design of the post LEBT in the RAON accelerator and the results of the beam dynamics simulations from it. In addition, the error analysis and correction in the post LEBT will be also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control of wakefield in sub-THz dielectric-lined waveguides using multiple-bunch excitation

Beam-driven wakefield accelerators offer the potential to achieve accelerating fields approaching the sub-GV/m range, paving the way for compact and cost-effective next-generation high-energy colliders. This method typically employs a two-bunch system: a drive bunch that excites an electromagnetic wakefield in a solid-state or plasma medium, and a witness bunch that extracts energy from the wake for acceleration. Our research focuses on two key challenges in wakefield acceleration using structures. First, we investigate strategies to suppress transverse instabilities by employing non-cylindrical geometries that damp dipole modes. Second, we explore methods to precisely terminate the wakefield after the interaction region, thereby improving the efficiency of energy transfer. This paper presents detailed simulation results and the corresponding experimental design developed to validate these concepts. Furthermore, the proposed experiment will be carried out at the Argonne Wakefield Accelerator (AWA) facility, focusing on controlling wakefield duration through tailored drive and witness bunch configurations and evaluating dielectric-lined structures with non-cylindrical cross sections.

43 PARTICLE ACCELERATORS↗

PIP-II Transfer Line Design

The U.S. Particle Physics Project Prioritization Panel (P5) report encouraged the realization of Fermilab's Proton Improvement Plan II (PIP-II) to support future neutrino programs in the United States. PIP-II aims at enhancing the capabilities of the Fermilab existing accelerator complex while simultaneously providing a flexible platform for its future upgrades. The central part of PIP-II project is the construction of a new 800 MeV H- Superconducting (SC) Linac together with upgrades of the Booster and Main Injector synchrotrons. New transfer lines will also be needed to deliver beam to the down-stream accelerators and facilities. In this paper we present the recent development of the design of the transfer lines discussing the principles that guided their design, the constraints and requirements imposed by the existing accelerator complex and the following modifications implemented to comply with a better understanding of the limitations and further requirements that emerged during the development of the project.

Vivoli, A.↗

Measurement of the LCLS-II dark current using the LDMX Trigger Scintillator Prototype

The Light Dark Matter eXperiment (LDMX) is a proposed fixed-target missing momentum search for sub-GeV thermal relic dark matter. LDMX aims to probe thermal dark matter targets with 1016 electrons on target. Such an approach requires a high-repetition rate, low-current beam, with an average of one electron on target per event. These requirements are well-suited to the DArk Sector Experiments at LCLS-II (DASEL) facility, which will take advantage of the unused RF buckets between LCLS-II bunches to produce a well-defined low-current beam with a 26.9 ns bunch spacing. This document describes the results of a measurement of dark current in the Sector 30 transfer line (S30XL) of the LCLS-II beam, using a prototype of the LDMX trigger scintillator (TS) subsystem.

Berzin, Elizabeth [SLAC]↗

Wavelength measurement of n = 3 - n' = 3 transitions in highly charged tungsten ions

3s{sub 1/2} - 3p{sub 3/2} and 3p{sub 1/2} - 3d{sub 3/2} transitions have been studied in potassium-like W{sup 55+} through neon-like W{sup 64}+ ions at the electron-beam ion trap facility in Livermore. The wavelengths of the lines have been measured in high resolution relative to well known reference lines from oxygen and nitrogen ions. Using the high-energy SuperEBIT electron-beam ion trap and an R = 44.3 m grazing-incidence soft x-ray spectrometer, the lines were observed with a cryogenic charge-coupled device camera. The wavelength data for the sodium-like and magnesium-like tungsten lines are compared with theoretical predictions for ions along the isoelectronic sequences.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of Laser Injection Seeder on Rotationally Resolved Spectra of Benzonitrile

High resolution lasers are necessary to derive the most information from molecular spectra. However, their use uncovers some photophysical processes that compromise the ability to resolve rotational structure. We study the influence of laser optical mode structure on the high resolution spectra of the S{sub 1} states of benzonitrile in a supersonic molecular beam using an Ar{sup +} pumped cw ring dye laser which is amplified by a pulsed Nd:YAG laser. The latter could be operated either in one optical mode by injecting (seeding) its oscillator with a single mode diode laser, or with many optical modes by not using the seeder. Rotationally resolved lines are obtained when the oscillator of the YAG laser are operated in one single optical mode, but only a continuum is seen when the YAG laser has multiple modes. It is argued that the ac Stark effect is the most probable reason for broadening and blurring the rotational lines.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observations of the 145.5 micron (OI) emission line in the Orion nebula

A first set of observations of the (OI) 3P to 3P1 (145.5 micron) transition was obtained. The line was observed both in a beam centered on the Trapezium, and in a 7 times wider beam encompassing most of the Orion Nebula. A wide beam map of the region was constructed which shows that most of the emission is confined to the central regions of the nebula. These observations may be compared with reported measurement of the 3P1 to 3P2 (63.2 micron) transition in Orion and are consistent with optically thin emission in the 145.5 micron line and self-adsorbed 63.2 micron emission lines. Mechanisms are discussed for the excitation of neutral oxygen. It is included that much of the observed emission originates in the thin, radio-recombination-line-emitting CII/HI envelope bordering on the HII region.

Stacey, G. J.↗

Self-corrected Sensors Based On Atomic Absorption Spectroscopy For Atom Flux Measurements In Molecular Beam Epitaxy

A high sensitivity atom flux sensor based on atomic absorption spectroscopy has been designed and implemented to control electron beam evaporators and effusion cells in a molecular beam epitaxy system. Using a high-resolution spectrometer and a two-dimensional charge coupled device (CCD) detector in a double-beam configuration, we employ a non-resonant line or a resonant line with lower absorbance from the same hollow cathode lamp as the reference for nearly perfect background correction and baseline drift removal. This setup also significantly shortens the warm-up time needed compared to other sensor technologies and drastically reduces the noise coming from the surrounding environment. In addition, the high-resolution spectrometer allows the most sensitive resonant line to be isolated and used to provide excellent signal-to-noise ratio.

Environmental Molecular Sciences Laboratory↗

Formation of conductive copper lines by femtosecond laser irradiation of copper nitride film on plastic substrates

In this paper, we report a simple method to form conductive copper lines by scanning a single-beam femtosecond pulse laser on a plastic substrate covered with copper nitride (Cu{sub 3}N) film. The Cu{sub 3}N films were prepared by DC magnetron sputtering in the presence of an Ar + N{sub 2} atmosphere at 100 °C. The influence of the laser power and scanning speed on the formed copper line width, surface features, and morphology was analyzed by means of optical microscopy, X-ray diffraction, non-contact 3D profilometer, and scanning electron microscopy. The experimental results demonstrate that low laser power and low scanning speed favor the formation of uniform and flat Cu lines. After process optimization, copper lines with a width less than 5 μm were obtained, which provides an attractive application prospect in the field of flexible electronic devices.

36 MATERIALS SCIENCE↗

Study of electron impact excitation of argon in the extreme ultraviolet - Emission cross section of resonance lines of Ar I, Ar II

In a crossed-beam experiment under optically thin conditions the EUV spectrum of argon produced by electron impact excitation is studied. The cross sections of the resonance lines of Ar I and II are measured. The resonance lines of Ar I at 104.8 nm and 106.7 nm, and of Ar II at 91.96 nm and 93.21 nm are the most prominent features of the EUV spectrum between 40 and 110 nm. The relative-flow technique is used to measure the absolute cross sections of these lines at 200 eV. The measurements are compared with previous estimates. The measured emission cross section values at 200 eV for the Ar I lines at 104.8 nm and 106.7 nm, when compared to the electron energy loss estimates of the direct excitation cross sections, establish that cascading is larger for the Ar I resonance lines than previous emission experiments have indicated. In addition, all the emission cross sections for the Ar I and II Rydberg series in the EUV are measured at 0.5 nm resolution. The FUV spectrum is also surveyed and found to consist of Ar II multiplets from simultaneous ionization-excitation.

Ajello, Joseph M.↗