Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

A pencil beam approach to proton computed tomography

Purpose: A new approach to proton computed tomography (pCT) is presented. In this approach, protons are not tracked one-by-one but a beam of particles is considered instead. The elements of the pCT reconstruction problem (residual energy and path) are redefined on the basis of this new approach. An analytical image reconstruction algorithm applicable to this scenario is also proposed. Methods: The pencil beam (PB) and its propagation in matter were modeled by making use of the generalization of the Fermi–Eyges theory to account for multiple Coulomb scattering (MCS). This model was integrated into the pCT reconstruction problem, allowing the definition of the mean beam path concept similar to the most likely path (MLP) used in the single-particle approach. A numerical validation of the model was performed. The algorithm of filtered backprojection along MLPs was adapted to the beam-by-beam approach. The acquisition of a perfect proton scan was simulated and the data were used to reconstruct images of the relative stopping power of the phantom with the single-proton and beam-by-beam approaches. The resulting images were compared in a qualitative way. Results: The parameters of the modeled PB (mean and spread) were compared to Monte Carlo results in order to validate the model. For a water target, good agreement was found for the mean value of the distributions. As far as the spread is concerned, depth-dependent discrepancies as large as 2%–3% were found. For a heterogeneous phantom, discrepancies in the distribution spread ranged from 6% to 8%. The image reconstructed with the beam-by-beam approach showed a high level of noise compared to the one reconstructed with the classical approach. Conclusions: The PB approach to proton imaging may allow technical challenges imposed by the current proton-by-proton method to be overcome. In this framework, an analytical algorithm is proposed. Further work will involve a detailed study of the performances and limitations of this approach in terms of image quality. The paper shows how to account for the MCS in the reconstruction step with this new approach when an analytical reconstruction algorithm is used.

60 APPLIED LIFE SCIENCES↗

Theoretical substantiation of biological efficacy enhancement for β-delayed particle decay {sup 9}C beam: A Monte Carlo study in combination with analysis with the local effect model approach

Purpose: To improve the efficacy of heavy ion therapy, β-delayed particle decay {sup 9}C beam as a double irradiation source for cancer therapy has been proposed. The authors’ previous experiment showed that relative biological effectiveness (RBE) values at the depths around the Bragg peak of a {sup 9}C beam were enhanced and compared to its stable counterpart {sup 12}C beam. The purpose of this study was to explore the nature of the biological efficacy enhancement theoretically. Methods: A Monte Carlo simulation study was conducted in this study. First a simplified cell model was established so as to form a tumor tissue. Subsequently, the tumor tissue was imported into the Monte Carlo simulation software package GATE and then the tumor cells were virtually irradiated with comparable {sup 9}C and {sup 12}C beams, respectively, in the simulations. The transportation and particle deposition data of the {sup 9}C and {sup 12}C beams, derived from the GATE simulations, were analyzed with the authors’ local effect model implementation so as to deduce cell survival fractions. Results: The particles emitted from the decay process of deposited {sup 9}C particles around a cell nucleus increased the dose delivered to the nucleus and elicited clustered damages around the secondary particles’ trajectories. Therefore, compared to the {sup 12}C beam, the RBE value of the {sup 9}C beam increased at the depths around their Bragg peaks. Conclusions: Collectively, the increased local doses and clustered damages due to the decayed particles emitted from deposited {sup 9}C particles led to the RBE enhancement in contrast with the {sup 12}C beam. Thus, the enhanced RBE effect of a {sup 9}C beam for a simplified tumor model was shown theoretically in this study.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-200: Dosimetric Variation of Organs at Risk for Recurrent Nasopharyngeal Carcinoma (rNPC) Patients Treated by Carbon Ion Beams

Purpose: Investigate the factors which affect the doses of organs at risk (OARs) for head and neck carbon ion therapy. Methods: Ten locally recurrent nasopharyngeal carcinoma cases with similar prescriptions were selected. All patients’ organs at risk (OARs) as well as CTVs were contoured by an experienced physician. Carbon ion treatment plans were created using a Syngo treatment planning system (Siemens, Germany). The CTVs were expanded to make optimized target volumes (OTVs) by considering treatment uncertainties and OAR protections. All plans were reviewed by this physician to be clinically acceptable. The OTV was expanded an additional 3mm to define the volume where beam spots could be put. A volume was also drawn 6 mm around the OTV to approximate the 50 % dose volume. The volumes where the OARs overlapped the OTV + 3 mm and OTV + 6 mm volumes, termed residual volumes, were then calculated. Results: The residual volumes within OTV + 3 mm were directly related to the OAR maximum dose. The percentage of the residual volume within the OTV + 6 mm with respect to the OAR volume was strongly related to the OAR mean doses. OAR mean doses also were affected by the beam setups. For example, if the OARs were in the beam entrance, the superior beams would sharply decrease the mean doses of the OARs hit by the lateral beams while increasing the mean doses of the OARs hit by the superior beam; the mean dose of the OARs which were hit by higher weight beams would be higher than the OARs hit by lower weight beams. Conclusion: Physicians should be cautious when contouring OARs, especially those close to CTVs and sensitive to large doses. Planners should set the OTV and beam parameters properly in order to save the OARs.

60 APPLIED LIFE SCIENCES↗

SU-F-T-207: Does the Greater Flexibility of Pencil Beam Scanning Reduce the Need for a Proton Gantry?

Purpose: Gantry-less proton treatment facility could lower the capital cost of proton therapy. This study investigates the dosimetric feasibility of using only coplanar pencil beam scanning (PBS) beams for those patients who had beam angles that would not have been deliverable without the gantry. Those coplanar beams are implemented on gantry-less horizontal beam-line with patients in sitting or standing positions. Methods: We have selected ten patients (seven head-and-neck, one thoracic, one abdominal and one pelvic case) with clinically delivered double scattering (DS) or PBS treatment plans with beam angles that were challenging to achieve without a gantry. After removing these beams angles, PBS plans were optimized for gantry-less intensity modulated proton therapy (IMPT) or single field optimization (SFO) with multi-criteria optimization (MCO). For head-and-neck patients who were treated by DS, we generated PBS plans with non-coplanar beams for comparison. Dose-volume-histograms (DVHs), target homogeneity index (HI), mean dose, D-2 and D-98 were reported. Robustness analysis was performed with ±2.5 mm setup errors and ±3.5% range uncertainties for three head-and-neck patients. Results: PBS-gantry-less plans provided more homogenous target coverage and significant improvements on organs-at-risk (OARs) sparing, compared to passive scattering treatments with a gantry. The PBS gantry-less treatments reduced the HI for target coverage by 1.3% to 47.2%, except for a suprasellar patient and a liver patient. The PBS-gantry-less plans reduced the D-mean of OARs by 3.6% to 67.4%. The PBS-gantry plans had similar target coverage and only marginal improvements on OAR sparing as compared to the PBS-gantry-less plans. These two PBS plans also had similar robustness relative to range uncertainties and setup errors. Conclusion: The gantry-less plans have with less mean dose to OARs and more homogeneous target coverage. Although the PBS-gantry plans have slightly improved target coverage and OARs sparing, the overall benefit of having a gantry to provide non-coplanar beams is debatable.

60 APPLIED LIFE SCIENCES↗

SU-F-T-494: A Multi-Institutional Study of Independent Dose Verification Using Golden Beam Data

Purpose: In general, beam data of individual linac is measured for independent dose verification software program and the verification is performed as a secondary check. In this study, independent dose verification using golden beam data was compared to that using individual linac’s beam data. Methods: Six institutions were participated and three different beam data were prepared. The one was individual measured data (Original Beam Data, OBD) .The others were generated by all measurements from same linac model (Model-GBD) and all linac models (All-GBD). The three different beam data were registered to the independent verification software program for each institute. Subsequently, patient’s plans in eight sites (brain, head and neck, lung, esophagus, breast, abdomen, pelvis and bone) were analyzed using the verification program to compare doses calculated using the three different beam data. Results: 1116 plans were collected from six institutes. Compared to using the OBD, the results shows the variation using the Model-GBD based calculation and the All-GBD was 0.0 ± 0.3% and 0.0 ± 0.6%, respectively. The maximum variations were 1.2% and 2.3%, respectively. The plans with the variation over 1% shows the reference points were located away from the central axis with/without physical wedge. Conclusion: The confidence limit (2SD) using the Model-GBD and the All-GBD was within 0.6% and 1.2%, respectively. Thus, the use of golden beam data may be feasible for independent verification. In addition to it, the verification using golden beam data provide quality assurance of planning from the view of audit. This research is partially supported by Japan Agency for Medical Research and Development(AMED)

60 APPLIED LIFE SCIENCES↗

SU-F-T-514: Evaluation of the Accuracy of Free-Breathing and Deep Inspiration Breath-Hold Gated Beam Delivery Using An Elekta Linac

Purpose: In this study, we evaluated the performance of an Elekta linac in the delivery of gated radiotherapy. We examined whether the use of either a short gating window or a long beam hold impacts the accuracy of the delivery Methods: The performance of an Elekta linac in the delivery of gated radiotherapy was assessed using a 20cmX 20cm open field with the radiation delivered using a range of beam-on and beam-off time periods. Two SBRT plans were used to examine the accuracy of gated beam delivery for clinical treatment plans. For the SBRT cases, tests were performed for both free-breathing based gating and for gated delivery with a simulated breath-hold. A MatriXX 2D ion chamber array was used for data collection, and the gating accuracy was evaluated using gamma score. Results: For the 20cmX20cm open field, the gated beam delivery agreed closely with the non-gated delivery results. Discrepancies in the agreement, however, began to appear with a 5-to-1 ratio of the beam-off to beam-on. For these tight gating windows, each beam-on segment delivered a small number of monitor units. This finding was confirmed with dose distribution analysis from the delivery of the two VMAT plans where the gamma score(±1%,2%/1mm) showed passing rates in the range of 95% to 100% for gating windows of 25%, 38%, 50%, 63%, 75%, and 83%. Using a simulated sinusoidal breathing signal with a 4 second period, the gamma score of freebreathing gating and breath-hold gating deliveries were measured in the range of 95.7% to 100%. Conclusion: The results demonstrate that Elekta linacs can be used to accurately deliver respiratory gated treatments for both free-breathing and breath-hold patients. The accuracy of beams delivered in a gated delivery mode at low small MU proved higher than similar deliveries performed in a non-gated (manually interrupted) fashion.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-15: Proton Beam Behavior in the Presence of Realistic Magnet Fields

Purpose: To investigate the effects of magnetic fields on proton therapy beams for integration with MRI. Methods: 3D magnetic fields from an open-bore superconducting MRI model (previously developed by our group) and 3D magnetic fields from an in-house gradient coil design were applied to various mono energetic proton pencil beam (80MeV to 250MeV) simulations. In all simulations, the z-axis of the simulation geometry coincided with the direction of the B0 field and magnet isocentre. In each simulation, the initial beam trajectory was varied. The first set of simulations performed was based on analytic magnetic force equations (analytic simulations), which could be rapidly calculated yet were limited to propagating proton beams in vacuum. The second set is full Monte Carlo (MC) simulations, which used GEANT4 MC toolkit. Metrics such as the beam position and dose profiles were extracted. Comparisons between the cases with and without magnetic fields present were made. Results: The analytic simulations served as verification checks for the MC simulations when the same simulation geometries were used. The results of the analytic simulations agreed with the MC simulations performed in vacuum. The presence of the MRI’s static magnetic field causes proton pencil beams to follow a slight helical trajectory when there were some initial off-axis components. The 80MeV, 150MeV, and 250MeV proton beams rotated by 4.9o, 3.6o, and 2.8o, respectively, when they reached z=0cm. The deflections caused by gradient coils’ magnetic fields show spatially invariant patterns with a maximum range of 0.5mm at z=0cm. Conclusion: This investigation reveals that both the MRI’s B0 and gradient magnetic fields can cause small but observable deflections of proton beams at energies studied. The MRI’s static field caused a rotation of the beam while the gradient coils’ fields effects were spatially invariant. Dr. B Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)

60 APPLIED LIFE SCIENCES↗

TU-H-BRC-05: Stereotactic Radiosurgery Optimized with Orthovoltage Beams

Purpose: To achieve improved stereotactic radiosurgery (SRS) dose distributions using orthovoltage energy fluence modulation with inverse planning optimization techniques. Methods: A pencil beam model was used to calculate dose distributions from the institution’s orthovoltage unit at 250 kVp. Kernels for the model were derived using Monte Carlo methods as well as measurements with radiochromic film. The orthovoltage photon spectra, modulated by varying thicknesses of attenuating material, were approximated using open-source software. A genetic algorithm search heuristic routine was used to optimize added tungsten filtration thicknesses to approach rectangular function dose distributions at depth. Optimizations were performed for depths of 2.5, 5.0, and 7.5 cm, with cone sizes of 8, 10, and 12 mm. Results: Circularly-symmetric tungsten filters were designed based on the results of the optimization, to modulate the orthovoltage beam across the aperture of an SRS cone collimator. For each depth and cone size combination examined, the beam flatness and 80–20% and 90–10% penumbrae were calculated for both standard, open cone-collimated beams as well as for the optimized, filtered beams. For all configurations tested, the modulated beams were able to achieve improved penumbra widths and flatness statistics at depth, with flatness improving between 33 and 52%, and penumbrae improving between 18 and 25% for the modulated beams compared to the unmodulated beams. Conclusion: A methodology has been described that may be used to optimize the spatial distribution of added filtration material in an orthovoltage SRS beam to result in dose distributions at depth with improved flatness and penumbrae compared to standard open cones. This work provides the mathematical foundation for a novel, orthovoltage energy fluence-modulated SRS system.

60 APPLIED LIFE SCIENCES↗

WE-AB-209-08: Novel Beam-Specific Adaptive Margins for Reducing Organ-At-Risk Doses

Purpose: Current practice of using 3D margins in radiotherapy with high-energy photon beams provides larger-than-required target coverage. According to the photon depth-dose curve, target displacements in beam direction result in minute changes in dose delivered. We exploit this behavior by generating margins on a per-beam basis which simultaneously account for the relative distance of the target and adjacent organs-at-risk (OARs). Methods: For each beam, we consider only geometrical uncertainties of the target location perpendicular to beam direction. By weighting voxels based on its proximity to an OAR, we generate adaptive margins that yield similar overall target coverage probability and reduced OAR dose-burden, at the expense of increased target volume. Three IMRT plans, using 3D margins and 2D per-beam margins with and without adaptation, were generated for five prostate patients with a prescription dose Dpres of 78Gy in 2Gy fractions using identical optimisation constraints. Systematic uncertainties of 1.1, 1.1, 1.5mm in the LR, SI, and AP directions, respectively, and 0.9, 1.1, 1.0mm for the random uncertainties, were assumed. A verification tool was employed to simulate the effects of systematic and random errors using a population size of 50,000. The fraction of the population that satisfies or violates a given DVH constraint was used for comparison. Results: We observe similar target coverage across all plans, with at least 97.5% of the population meeting the D98%>95%Dpres constraint. When looking at the probability of the population receiving D5<70Gy for the rectum, we observed median absolute increases of 23.61% (range, 2.15%–27.85%) and 6.97% (range, 0.65%–17.76%) using per-beam margins with and without adaptation, respectively, relative to using 3D margins. Conclusion: We observed sufficient and similar target coverage using per-beam margins. By adapting each per-beam margin away from an OAR, we can further reduce OAR dose without significantly lowering target coverage probability by irradiating more less-important tissues. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.

07 ISOTOPE AND RADIATION SOURCES↗

Roadmap for the Application of Ion Beam Technologies to Challenges for the Advancement and Implementation of Nuclear Energy Technologies

The use of ion beams in interrogating materials performance for nuclear energy applications is advancing at a rapid rate. Ion irradiations have been proven to produce radiation effects data that are of direct relevance for understanding neutron-induced displacement damage. This development reflects significant and continued investment in infrastructure by the U.S. Department of Energy (DOE) as well as support of science and engineering research at universities and national laboratories. Application of ion beam irradiation methods to enhance the deployment of materials in reactors is in the spirit of the Gateway for Accelerated Innovation in Nuclear (GAIN) initiative sponsored by DOE to accelerate the deployment of innovation in the U.S. nuclear industry. Ion beam irradiation shows considerable promise for assisting in down selecting candidate materials for use in both current and advanced nuclear energy systems. Ion beams allow rapid achievement of materials damage levels not accessible by neutron irradiation in test reactors due to cost and time constraints. Ion beam studies provide data on the effects of irradiation under very specific conditions of temperature, radiation dose, and radiation dose rate that are difficult or impossible to achieve via reactor irradiation experiments. This data can be used to develop and validate detailed predictive radiation effects models for use in reactor materials research and development. Despite the current high state of the art and the maturity of quality assurance, there are still challenges to the deployment of ion beam data in support of reactor materials qualification. For the most part, these challenges arise from the lack of a detailed mechanistic understanding of potential difference between ion induced and neutron induced materials damage, which is exacerbated by difficulties in obtaining bulk physical and mechanical properties data from the micron-scale heavy ion irradiation depths. In particular, improved understanding of dose rate effects, as a function of temperature, are needed. This document offers a roadmap for the development and enhancement of current U.S. ion beam irradiation technologies within university and national laboratory settings, and especially for the deployment of new highly controlled in situ interrogation of materials during irradiation to provide dynamic and mechanistic data for model development. The status and capabilities of relevant U.S. ion beam facilities are summarized and recommended “best practices” for performing ion irradiations are described. The potential role of ion beam irradiations to assist the development and deployment of reactor materials is outlined. Key principles include developing methods for rapid and cost-effective materials selection and development, characterizing fundamental material response under irradiation, and developing a robust mechanistic understanding of microstructure evolution under irradiation (including development and validation of reliable predictive models for microstructure evolution).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of electron beam technology to decompose persistent emerging drinking water contaminants: poly- and perfluoroalkyl substances (PFAS) and 1,4-Dioxane

Poly- and perfluoroalkyl substances (PFAS) and 1,4-dioxane are persistent emerging contaminants that are currently under consideration for federal and state-specific regulations in drinking water. Both PFAS and 1,4-dioxane are highly resistant to degradation and are not effectively removed by conventional drinking water treatment systems. Results from the Unregulated Contaminant Monitoring Rule 3 survey showed that >540 sites across the nation are contaminated with both PFAS and 1,4-dioxane. Hence, there is a need to identify technologies that can effectively remove both these contaminants. Water treatment via electron beam (e-beam) has been proven effective at treating a wide range of contaminants, including perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), polychlorinated biphenyls, and trichloroethylene. While the e-beam process is often considered similar to advanced oxidation processes (AOPs), e-beam technology is unique in that it produces both highly oxidizing and reducing species at the same time. The specific objectives of this study were to: (i) determine the effectiveness of 9 MeV electrons provided by the Fermilab’s Accelerator Application Development and Demonstration (A2D2) tool to decompose PFAS and 1,4-dioxane; (ii) assess the formation of byproducts during water treatment; (iii) apply the optimized treatment to field groundwater samples contaminated with PFAS and 1,4-dioxane, and (iv) assess the energy demands for the treatment of these contaminants using e-beam. Results from this study showed that e-beam is effective in treating both 1,4-dioxane and PFAS. Complete degradation of 1,4-dioxane was observed at a dose of 5 kGy for an initial concentration of up to 1 ppm without the need for any sample modification. The electrical energy per order (EEo) for treatment of 1,4-dioxane ranged from 0.46 to 0.72 kWh/m 3 /order and was comparable and even lower, in some cases, than other AOP technologies. Alkaline conditions (pH 13) and low dissolved oxygen concentration (2 mg/L) highly favored the treatment of PFAS by e-beam. Greater than 90% removal of PFOA and PFOS from an initial concentration of 100 to 500 ppb was achieved at a dose of 250 kGy and 500 kGy, respectively, under optimized conditions. The degradation efficiency was not significantly changed when treating other PFAS of fluorinated carbon chain length of 5 to 7 individually at 250 kGy with a removal ranging from 85¬–99% for different compounds. Short chain PFAS (perfluorobutanoate: PFBA and perfluorobutane sulfonate: PFBS) did not degrade under the same conditions at 250 kGy, but 70 to 99% degradation was observed at a higher dose of 1000 kGy. Short chain PFAS (perfluorohexanoate: PFHxA (C5) and perfluoroheptanoate: PFHpA (C6)) were detected after treatment of PFOA, but not after PFOS treatment. Inability to close the mass balance through targeted analysis suggests the presence of other intermediates not detectable by available analytical methods. When treating PFAS mixture containing ten compounds at equimolar concentration of 0.05 µM each, preferential degradation of polyfluorinated compound (6:2 fluorotelomer sulfonate or 6:2 FTS) followed by C8 and C7 compounds was observed as a function of increasing e-beam dose. About 30% degradation of ΣPFAS was observed at 250 kGy and no further removal was observed up to a dose of 1000 kGy. C4 to C6 PFASs showed no degradation, while C3 PFAS (PFBS) showed an increase in concentration by 34% at 1000 kGy due to formation from the breakdown of other long chain PFAS. These results suggested that (a) the reaction kinetics is likely different for different PFAS based on chain length, functional group, and the degree of fluorination of the carbon chain, and (b) there may be intermediates generated from the degradation of 6:2 FTS and C7/C8 compounds that can potentially scavenge hydrated electrons needed for reaction with the untreated PFAS molecules. Treatment of three PFAS-contaminated groundwater samples from two US states showed similar trends as observed in the treatment of equimolar PFAS mixtures. Up to 71% removal of ΣPFAS was achieved in real groundwater samples at 750 kGy and data trend suggested that higher degradation is feasible if higher doses (>1MGy) are applied to treat field samples to overcome matrix effects and competing species. Calculated EEo for PFAS ranged from as low as ~48 to 1081 kWh/m 3 /order depending on the type of PFAS treated. These values are comparable and even lower, in some cases, than other destructive technologies employed for PFAS treatment such as ultrasound, plasma, and photochemical treatment. The results from this study indicate e-beam is a promising approach under favorable conditions and should be explored further as an end-of-train treatment option for PFAS destruction.

1,4-Dioxane↗

Improving beam spectral and spatial quality by double-foil target in laser ion acceleration for ion-driven fast ignition

Mid-Z ion driven fast ignition inertial fusion requires ion beams of 100s of MeV energy and < 10% energy spread. An overdense run-scale foil target driven by a high intensity laser pulse can produce an ion beam that has attractive properties for this application. The Break Out Afterburner (BOA) is one laser-ion acceleration mechanism proposed to generate such beams, however the late stages of the BOA tend to produce too large of an energy spread. The spectral and spatial qualities of the beam quickly evolve as the ion beam and co-moving electrons continue to interact with the laser. Here we show how use of a second target foil placed behind a nm-scale foil can substantially reduce the temperature of the co-moving electrons and improve the ion beam energy spread. Particle-In-Cell simulations reveal the dynamics of the ion beam under control. Optimal conditions for improving the spectral and spatial spread of the ion beam is explored for current laser and target parameters, leading to generation of ion beams of energy 100s of MeV and 6% energy spread, a vital step for realizing ion-driven fast ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanical Design of a High Energy Beam Absorber for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab

A high energy beam absorber has been built for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab. In the facility's initial configuration, an electron beam will be accelerated through 3 TTF-type or ILC-type SRF cryomodules to an energy of 750MeV. The electron beam will be directed to one of multiple downstream experimental and diagnostic beam lines and then deposited in one of two beam absorbers. The facility is designed to accommodate up to 6 cryomodules, which would produce a 75kW beam at 1.5GeV; this is the driving design condition for the beam absorbers. The beam absorbers consist of water-cooled graphite, aluminum and copper layers contained in a helium-filled enclosure. This paper describes the mechanical implementation of the beam absorbers, with a focus on thermal design and analysis. The potential for radiation-induced degradation of the graphite is discussed.

43 PARTICLE ACCELERATORS↗

Development of Electronics for the ATF2 Interaction Point Region Beam Position Monitor

Nanometer resolution beam position monitors have been developed to measure and control beam position stability at the interaction point region of ATF2. The position of the beam has to be measured to within a few nanometers at the interaction point. In order to achieve this performance, electronics for the low-Q IP-BPM was developed. Every component of the electronics have been simulated and checked on the bench and using the ATF2 beam. We will explain each component and define their working range. Then, we will show the performance of the electronics measured with beam signal. ATF2 is a final focus test beam line for ILC in the framework of the ATF international collaboration. The new beam line was constructed to extend the extraction line at ATF, KEK, Japan. The first goal of ATF2 is the acheiving of a 37 nm vertical beam size at focal point (IP). The second goal is to stabilize the beam at the focal point at a few nanometer level for a long period in order to ensure the high luminosity. To achieve these goals a high resolution IP-BPM is essential. In addition for feedback applications a low-Q system is desirable.

43 PARTICLE ACCELERATORS↗

Characterizing the Thermal Column Beam in the University of Massachusetts Lowell Research Reactor

The University of Massachusetts Lowell operates a 1 MW, light water cooled and moderated Research Reactor (UMLRR) fueled by low-enriched uranium to generate neutron flux that is used at a variety of in-core and beam port facilities within the reactor to perform irradiation experiments for academic and industrial research. One of the irradiation sites is a graphite-moderated thermal column designed to deliver a collimated beam of thermal neutrons to a neutron radiography imaging system. A detailed characterization of the neutron beam is essential for the design and interpretation of experiments at the facility and for radiation safety. This work aimed to characterize the neutron flux and energy spectrum in the UMLRR thermal column beam by employing experimental and computational methods known as the foil activation and spectrum unfolding technique. A previously existing Monte Carlo N-Particle transport (MCNP) model of the UMLRR reactor core has been extended to the thermal column where the neutron flux and energy spectrum have been computed and experimentally validated. This work employed the foil activation and spectrum unfolding technique along with neutron transport computation to extend the knowledge of the neutron fluence and energy spectrum from the UMLRR core to the adjacent thermal column beam. Radiography systems are used for materials characterization, studying dynamic behavior of engineering systems, and for nuclear forensics applications. Foil activation is an experimental method where thin foils of highly pure materials are placed in the beam where interactions between the neutrons and the foil material activate radioisotopes in the foils whose activities can be measured after the irradiation. Downstream computation with MCNP and the spectrum unfolding code SAND can deconvolute the neutron fluence and energy spectrum that must have been necessary to induce the production rates of radioisotopes that were obtained through foil activation. The necessary ingredients for successful spectrum unfolding are the experimentally measured production rates and some a priori (initial guess) knowledge of the flux spectrum. The thermal column is equipped with a neutron radiography imaging system, so any experimenters who desire to use neutron radiography at UMass Lowell will benefit significantly from knowing the characteristics of the neutron beam. Comprehensive knowledge of these characteristics of the beam is essential to compare and benchmark results obtained for similar experiments at other facilities. The Integrated Nuclear Security and Safeguards Laboratory (INSSL) is pursuing the investigation of the performance of self-healing materials under stress-strain environments and the characterization of radiation detectors and special containers for storing and transporting nuclear material. This work contributes to the improvement of the current radiography system, expands the utility of the system for nuclear safeguards and security application and provides information that will enhance the general safety of the UMLRR experimental facilities. The main objective of this work has been achieved; an appropriate neutron flux spectrum for the UMLRR thermal column beam has been determined using the foil activation method followed by spectrum unfolding. There now exists an experimentally validated computational model of the neutron flux spectrum and the thermal column's neutron environment is characterized. We can conclude that the thermal column is well characterized; an appropriate neutron flux spectrum has been determined through an experimentally validated computational model. Future experimenters interested in the thermal column may now expand on the computational model or use the spectral information for their own purposes. The knowledge gained herein will be helpful for the INSSL's future work using neutron radiography to analyze the effectiveness of self-healing materials and special containers. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Laser wire beam profile monitor in the Spallation Neutron Source (SNS) superconducting linac

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is an accelerator based neutron scattering facility. The SNS uses the large scale high energy superconducting linac (SCL) to provide high beam power utilizing hydrogen ion (H-) beams. For the diagnostics of high-brightness H- beam in the SCL, nonintrusive methods have to be developed. This paper describes design, implementation, theoretical analysis and experimental demonstration of a nonintrusive profile monitor system based on photodetachment, also known as laser wire, installed in the SNS-SCL. The SNS laser wire system is the largest of its kind with a capability of measuring both horizontal and vertical profiles of an operational H- beam at each of the 23 cryomodule stations along the SCL beam line by employing a single light source. Presently 9 laser wire stations have been commissioned which measures H- beam profiles at 9 different locations corresponding to energy levels of 200 MeV to 1 GeV. The laser wire diagnostics has no moving parts inside the beam pipe, causes no contamination on the superconducting surface, and can be run parasitically on an operational neutron production H- beam.

43 PARTICLE ACCELERATORS↗

Laser ion source: A direct plasma injection scheme for two-beam type interdigital-H radio frequency quadrupole linac

We developed a laser ion source using a direct plasma injection scheme (DPIS) as an injection system for a two-beam type radio frequency quadrupole (RFQ) linac with an interdigital-H (IH) type cavity. The laser ion source in the DPIS is directly connected to the RFQ cavity without the low energy beam transport system. We achieved a high current C{sup 2+} beam above 60 mA per beam channel from the ion source. The beam will be injected to the two-beam type IH-RFQ linac, and the linac will generate a beam current of approximately 44 mA per beam channel.

43 PARTICLE ACCELERATORS↗

Applications of laser produced ion beams to nuclear analysis of materials

Laser produced ion beams have unique characteristics which are ultra-short pulse, very low emittance, and variety of nuclear species. These characteristics could be used for analyzing various materials like low Z ion doped heavy metals or ceramics. Energies of laser produced ion beam extend from 0.1MeV to 100MeV. Therefore, various nuclear processes can be induced in the interactions of ion beams with samples. The ion beam driven nuclear analysis has been developed for many years by using various electrostatic accelerators. To explore the applicability of laser ion beam to the analysis of the Li ion battery, a proton beam with the diameter of {approx} 1.0 {mu}m at Takasaki Ion Acceleration for Advanced Radiation Application (TIARA), JAEA was used. For the analysis, the PIGE (Particle-Induced Gamma Ray Emission) is used. The proton beam scans over Li battery electrode samples to diagnose Li density in the LiNi{sub 0.85}Co{sub 0.15}O{sub 2} anode. As the results, PIGE images for Li area density distributions are obtained with the spatial resolution of better than 1.5{mu}m FWHM. By the Li PIGE images, the depth dependence of de-intercalation levels of Li in the anode is obtained. By the POP experiments at TIARA, it is clarified that laser produced ion beam is appropriate for the Li ion battery analysis. 41.85.Lc, 41.75.Jv, 42.62.cf.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗