Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Atomic and Molecular Data for Interstellar Studies: A Status Report

Most interstellar species have a large fraction of their electronic transitions at far ultraviolet wavelengths. Observations at these wavelengths reveal spectra rich in absorption lines seen against the continuum of a background source, such as a hot star in our Galaxy, a supernova in a nearby galaxy, or even a bright nucleus in an active galaxy. Most of the observations continue to be made with space-borne instruments, but recent work includes measurements of extragalactic material at large redshifts obtained at high resolution with large ground-based telescopes (e.g., the Keck Telescope). The combination of precise experimental oscillator strengths, large-scale computations, and astronomical spectra with high signal-to-noise ratios are yielding a set of self-consistent-values that span a range in strength in excess of 100 for more and more species. The large range is important for studies involving the different environments probed by the various background sources. This review highlights recent work on the atomic species. Si II, S I, and Fe II, and on the molecules, CO and C2.

Federman, Steven R.↗

Optimal Matched Filter in the Low-number Count Poisson Noise Regime and Implications for X-Ray Source Detection

Detection of templates (e.g., sources) embedded in low-number count Poisson noise is a common problem in astrophysics. Examples include source detection in X-ray images, γ-rays, UV, neutrinos, and search for clusters of galaxies and stellar streams. However, the solutions in the X-ray-related literature are sub-optimal in some cases by considerable factors. Using the lemma of Neyman–Pearson, we derive the optimal statistics for template detection in the presence of Poisson noise. We demonstrate that, for known template shape (e.g., point sources), this method provides higher completeness, for a fixed false-alarm probability value, compared with filtering the image with the point-spread function (PSF). In turn, we find that filtering by the PSF is better than filtering the image using the Mexican-hat wavelet (used by wavdetect). For some background levels, our method improves the sensitivity of source detection by more than a factor of two over the popular Mexican-hat wavelet filtering. This filtering technique can also be used for fast PSF photometry and flare detection; it is efficient and straightforward to implement. We provide an implementation in MATLAB. The development of a complete code that works on real data, including the complexities of background subtraction and PSF variations, is deferred for future publication.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical White-Line Analysis in High-Throughput TXM-XANES for Chemical State Quantification

The transmission X-ray microscopy (TXM) based X-ray absorption near-edge structure (XANES) technique provides three-dimensional mapping of element-specific chemical states at nanometer-scale spatial resolution and micrometer-scale fields of view. However, compared to conventional volume-averaged XANES (VA-XANES) measurements, the inherently small voxel size in TXM-XANES leads to a lower signal-to-noise ratio, making full-spectrum analysis computationally demanding and less robust. Here, we present the structural and compositional conditions for a statistical white-line analysis framework under which chemical state information can be directly extracted from the white-line peak position in voxel spectra without the need for voxel-wise background subtraction or normalization, under well-defined structural and compositional conditions. The method is validated on layered oxide cathode materials, where low-order polynomial fitting accurately reproduces white-line features, and the extracted energy distributions correlate strongly with VA-XANES results. This statistical approach enables high-throughput, dose-efficient, and noise-robust chemical state quantification in TXM-XANES, offering broad applicability to functional materials requiring nanoscale oxidation-state mapping.

TXM↗

Cross-correlation of gravitational lensing from DES Science Verification data with SPT and Planck lensing

We measure the cross-correlation between weak lensing of galaxy images and of the cosmic microwave background (CMB). The effects of gravitational lensing on different sources will be correlated if the lensing is caused by the same mass fluctuations. We use galaxy shape measurements from 139 deg(2) of the Dark Energy Survey (DES) Science Verification data and overlapping CMB lensing from the South Pole Telescope (SPT) and Planck. The DES source galaxies have a median redshift of z(med) similar to 0.7, while the CMB lensing kernel is broad and peaks at z similar to 2. The resulting cross-correlation is maximally sensitive to mass fluctuations at z similar to 0.44. Assuming the Planck 2015 best-fitting cosmology, the amplitude of the DESxSPT cross-power is found to be A(SPT) = 0.88 +/- 0.30 and that from DESxPlanck to be A(Planck) = 0.86 +/- 0.39, where A = 1 corresponds to the theoretical prediction. These are consistent with the expected signal and correspond to significances of 2.9 sigma and 2.2 sigma, respectively. We demonstrate that our results are robust to a number of important systematic effects including the shear measurement method, estimator choice, photo-z uncertainty and CMB lensing systematics. We calculate a value of A = 1.08 +/- 0.36 for DESxSPT when we correct the observations with a simple intrinsic alignment model. With three measurements of this cross-correlation now existing in the literature, there is not yet reliable evidence for any deviation from the expected LCDM level of cross-correlation. We provide forecasts for the expected signal-to-noise ratio of the combination of the five-year DES survey and SPT-3G.

Kirk, D.↗

NEW MEASUREMENTS OF THE COSMIC INFRARED BACKGROUND FLUCTUATIONS IN DEEP SPITZER/IRAC SURVEY DATA AND THEIR COSMOLOGICAL IMPLICATIONS

We extend previous measurements of cosmic infrared background (CIB) fluctuations to {approx}< 1 Degree-Sign using new data from the Spitzer Extended Deep Survey. Two fields with depths of {approx_equal} 12 hr pixel{sup -1} over three epochs are analyzed at 3.6 and 4.5 {mu}m. Maps of the fields were assembled using a self-calibration method uniquely suitable for probing faint diffuse backgrounds. Resolved sources were removed from the maps to a magnitude limit of mag{sub AB} {approx_equal} 25, as indicated by the level of the remaining shot noise. The maps were then Fourier transformed and their power spectra were evaluated. Instrumental noise was estimated from the time-differenced data, and subtracting this isolates the spatial fluctuations of the actual sky. The power spectra of the source-subtracted fields remain identical (within the observational uncertainties) for the three epochs indicating that zodiacal light contributes negligibly to the fluctuations. Comparing to 8 {mu}m power spectra shows that Galactic cirrus cannot account for the fluctuations. The signal appears isotropically distributed on the sky as required for an extragalactic origin. The CIB fluctuations continue to diverge to >10 times those of known galaxy populations on angular scales out to {approx}< 1 Degree-Sign . The low shot-noise levels remaining in the diffuse maps indicate that the large-scale fluctuations arise from the spatial clustering of faint sources well below the confusion noise. The spatial spectrum of these fluctuations is in reasonable agreement with an origin in populations clustered according to the standard cosmological model ({Lambda}CDM) at epochs coinciding with the first stars era.

79 ASTRONOMY AND ASTROPHYSICS↗

Memory-triggered supernova neutrino detection

Here, we demonstrate that observations of the gravitational memory from core collapse supernovae at future deci-Hz interferometers enable time-triggered searches of supernova neutrinos at Mt-scale detectors. Achieving a sensitivity to characteristic strains of at least $\sim 10^{–25}$ at $f ≃ 0.3$ $\mathrm{Hz}$ —e.g., by improving the noise of DECIGO by one order of magnitude—will allow robust time triggers for supernovae at distances $D \sim 40–300$ $\mathrm{Mpc}$, resulting in a nearly background-free sample of $\sim 3–70$ neutrino events per Mt per decade of operation. This sample would bridge the sensitivity gap between rare galactic supernova bursts and the cosmological diffuse supernova neutrino background, allowing detailed studies of the neutrino emission of supernovae in the local Universe.

79 ASTRONOMY AND ASTROPHYSICS↗

The DarkNESS mission: probing dark matter with a Skipper-CCD satellite observatory

The invention of Skipper-CCDs with sub-electron noise has paved the way for groundbreaking low-threshold dark matter (DM) experiments, such as SENSEI and DAMIC. Conventionally, these experiments are deployed underground to mitigate cosmogenic backgrounds; however, some DM signatures are inaccessible to underground experiments due to attenuation in the Earth’s atmosphere and crust. The DarkNESS mission will deploy an array of Skipper-CCDs on a 6U CubeSat in Low Earth Orbit (LEO) to search for electron recoils from strongly-interacting sub-GeV DM as well as X-ray line signatures from sterile neutrino decay. Using a series of observations from LEO, the DarkNESS mission will set competitive upper limits on the DM-electron scattering cross section and help resolve the experimental conundrum associated with the purported observation of a 3.5 keV X-ray line, potentially produced from sterile neutrino decay. This work will describe the DarkNESS instrument, the technical challenges in operating Skipper-CCDs in the space environment, the scientific objectives of the DarkNESS mission, and the DM parameter space that DarkNESS will probe.

79 ASTRONOMY AND ASTROPHYSICS↗

Cerenkov luminescence endoscopy: Improved molecular sensitivity with β - -emitting radiotracers

Cerenkov luminescence endoscopy (CLE) is an optical technique that captures the Cerenkov photons emitted from highly energetic moving charged particles (β + or β $-$ ) and can be used to monitor the distribution of many clinically available radioactive probes. A main limitation of CLE is its limited sensitivity to small concentrations of radiotracer, especially when used with a light guide. We investigated the improvement in the sensitivity of CLE brought about by using a β $-$ radiotracer that improved Cerenkov signal due to both higher β-particle energy and lower γ noise in the imaging optics because of the lack of positron annihilation. Here, the signal-to-noise ratio (SNR) of 90 Y was compared with that of 18 F in both phantoms and small-animal tumor models. Sensitivity and noise characteristics were demonstrated using vials of activity both at the surface and beneath 1 cm of tissue. Rodent U87MG glioma xenograft models were imaged with radiotracers bound to arginine-glycine-aspartate (RGD) peptides to determine the SNR. As a result, γ noise from 18 F was demonstrated by both an observed blurring across the field of view and a more pronounced fall-off with distance. A decreased γ background and increased energy of the β particles resulted in a 207-fold improvement in the sensitivity of 90 Y compared with 18 F in phantoms. 90 Y-bound RGD peptide produced a higher tumor-to-background SNR than 18 F in a mouse model. In conclusion, the use of 90 Y for Cerenkov endoscopic imaging enabled superior results compared with an 18 F radiotracer.

60 APPLIED LIFE SCIENCES↗

Measuring the Mean Free Path of H i Ionizing Photons at 3.2 ≤ z ≤ 4.6 with DESI Y1 Quasars

The mean free path of ionizing photons in the intergalactic medium (IGM; λ $^{912}_{mpf}$ ) is a crucial quantity in modeling the ionization state of the IGM and the extragalactic ultraviolet background, and it is widely used in hydrodynamical simulations of galaxies and reionization. We construct the largest quasar spectrum data set to date—12,595 signal-to-noise ratio > 3 spectra—using the Y1 observations of the Dark Energy Spectroscopic Instrument, to make the most precise model-independent measurement of the mean free path at 3.2 ≤ z ≤ 4.6. By stacking the spectra in 17 redshift bins and modeling the Lyman-continuum profile, we get a redshift evolution λ $^{912}_{mpf}$ ∝ ( 1 + z ) − 4.27 at 2 ≤ z ≤ 5, which is much shallower than the previous estimate, λ $^{912}_{mpf}$ ∝ ( 1 + z ) − 5.4 . We then explore the sources of systematic bias, including the choice of the intrinsic quasar continuum, the consideration of Lyman-series opacity and Lyman-limit opacity evolution, and the definition of λ $^{912}_{mpf}$ . Combining our results with estimates of λ $^{912}_{mpf}$ at higher redshifts, we conclude at high confidence that the evolution in λ $^{912}_{mpf}$ steepens at z ≈ 5. We interpret this inflection as the transition from the end of H i reionization to a fully ionized plasma that characterizes the IGM of the past ∼10 billion yr.

79 ASTRONOMY AND ASTROPHYSICS↗

A technology program for the development of the large deployable reflector for space based astronomy

Technologies for the development of the Large Deployable Reflector (LDR), a NASA project for the 1990's, for infrared and submillimeter astronomy are presented. The proposed LDR is a 10-30 diameter spaceborne observatory operating in the spectral region from 30 microns to one millimeter, where ground observations are nearly impossible. Scientific rationales for such a system include the study of ancient signals from galaxies at the edge of the universe, the study of star formation, and the observation of fluctuations in the cosmic background radiation. System requirements include the ability to observe faint objects at large distances and to map molecular clouds and H II regions. From these requirements, mass, photon noise, and tolerance budgets are developed. A strawman concept is established, and some alternate concepts are considered, but research is still necessary in the areas of segment, optical control, and instrument technologies.

Kiya, M. K.↗

Development of the Nano-HEB Array for Low-Background Far-IR Applications

We present an overview of the recent progress made in the development of a far-IR array of ultrasensitive hot-electronnanobolometers (nano-HEB) made from thin titanium (Ti) films. We studied electrical noise, signal and noisebandwidth, single-photon detection, optical noise equivalent power (NEP), and a microwave SQUID (MSQUID) basedfrequency domain multiplexing (FDM) scheme. The obtained results demonstrate the very low electrical NEP down to1.5x10-(sup 2)? W/Hz(sup 1)/(sup 2) at 50 mK determined by the dominating phonon noise. The NEP increases with temperature as ~ T(sup 3)reaching ~ 10-(sup 1)? W/Hz(sup 1)/(sup 2) at the device critical temperature TC = 330-360 mK. Optical NEP = 8.6x10-(sup 1)? W/Hz(sup 1)/(sup 2) at 357mK and 1.4x10-(sup 1)? W/Hz(sup 1)/(sup 2) at 100 mK respectively, agree with thermal and electrical data. The optical couplingefficiency provided by a planar antenna was greater than 50%. Single 8-?m photons have been detected for the first timeusing a nano-HEB operating at 50-200 mK thus demonstrating a potential of these detectors for future photon-countingapplications in mid-IR and far-IR. In order to accommodate the relatively high detector speed (~ ?s at 300 mK, ~ 100 ?sat 100 mK), an MSQUID based FDM multiplexed readout with GHz carrier frequencies has been built. Both the readoutnoise ~ 2 pA/Hz(sup 1)/(sup 2) and the bandwidth > 150 kHz are suitable for nano-HEB detectors.

single-photon↗

WE-AB-204-01: Performance Characterization of Regularized-Reconstruction Algorithm for 90Y PET/CT Images

Purpose: {sup 90}Y PET/CT imaging and quantification have recently been suggested as an approach of treatment verification. However, due to low positron yield (32ppm), the {sup 90}Y-PET/CT images are very noisy. Iterative reconstruction techniques that employ regularization, e.g. block sequential regularized expectation maximization (BSREM) algorithm (recently implemented on GE scanners – QClear™), has the potential to increase quantitative accuracy with lower noise penalty compared to OSEM. Our aim is to investigate the performance of RR algorithms in {sup 90}Y PET/CT studies. Methods: A NEMA IEC phantom filled with 3GBq {sup 90}YCl{sub 2} (to simulate patient treatment) was imaged on GE-D690 for 1800s/bed. The sphere-to-background ratio of 7. The data were reconstructed using OSEM and BSREM with PSF modeling and TOF correction while varying the iterations (IT) from 1–6 with fixed 24subsets. For BSREM, the edge-preservation parameter (γ ) was 2 and the penalty-parameters (β) was varied 350–950. In all cases a post-reconstruction filter of 5.2mm (2pixel) transaxial and standard z-axis were used. Sphere average activity concentration (AC) and background standard deviation (SD) were then calculated from VOIs drawn in the spheres and background. Results: Increasing IT from 1to6, the %SD in OSEM increased from 30% to 80%, whereas %SD in BSREM images increased by <5% for all βs. BSREM with β=350 didn’t offer any improvement over OSEM (convergence of mean achieved at 2 IT, in this study). Increasing β from 350 to 950 reduced the AC accuracy of small spheres (<20mm) by 10% and noise from 40% to 20%, which resulted in CNR increase from 11 to 17. Conclusion: In count-limited studies such as {sup 90}Y PET/CT, BSREM can be used to suppress image noise and increase CNR at the expense of a relatively small decrease of quantitative accuracy. The BSREM parameters need to be optimized for each study depending on the radionuclides and count densities. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA13898 and was also partly supported by General Electric.

60 APPLIED LIFE SCIENCES↗

Expansion dynamics of ultrafast laser produced plasmas in the presence of ambient argon

In this paper, we report the emission features of fs laser ablated brass plasma plumes at various Ar background pressure levels ranging from vacuum to atmospheric conditions. Spectrally integrated 2D-imaging of plasma self-emission showed several interesting features at various pressure levels which consists of plume morphological changes, increase in persistence, confinement, and internal structures. Spatially resolved wavelength dispersed images of the plume were recorded for characterizing the spectral features at various pressure levels and also used for obtaining spatial distribution of Cu I and Zn I species in the plume, signal to noise ratios and fundamental parameters of the plasma; viz. temperature and density. The spatial evolution of excitation temperature and density showed significant changes at various ambient pressure levels and these results were correlated to morphological changes seen in the plume images. Optimum signal to background ratios for emission lines were observed in the moderate pressure range (~ 1-10 Torr). Optical time-of-flight profiles were used to study time evolution of various species in the plume and noticed oscillations at intermediate pressure levels. Possible mechanisms for observed changes in plume shape, optical emission intensity, and dual peak structures in time-of-flight profiles were discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constraints upon the spectral indices of relic gravitational waves by LIGO S5

With LIGO having achieved its design sensitivity and the LIGO S5 strain data being available, constraints on the relic gravitational waves (RGWs) become realistic. The analytical spectrum of RGWs generated during inflation depends sensitively on the initial condition, which is generically described by the index {beta}, the running index {alpha}{sub t}, and the tensor-to-scalar ratio r. By the LIGO S5 data of the cross-correlated two detectors, we obtain constraints on the parameters ({beta},{alpha}{sub t},r). As a main result, we have computed the theoretical signal-to-noise ratio of RGWs for various values of ({beta},{alpha}{sub t},r), using the cross-correlation for the given pair of LIGO detectors. The constraints by the indirect bound on the energy density of RGWs by big bang nucleosynthesis and cosmic microwave background have been obtained, which turn out to be still more stringent than LIGO S5.

79 ASTRONOMY AND ASTROPHYSICS↗

Coherent Detection of High-Rate Optical PPM Signals

A method of coherent detection of high-rate pulse-position modulation (PPM) on a received laser beam has been conceived as a means of reducing the deleterious effects of noise and atmospheric turbulence in free-space optical communication using focal-plane detector array technologies. In comparison with a receiver based on direct detection of the intensity modulation of a PPM signal, a receiver based on the present method of coherent detection performs well at much higher background levels. In principle, the coherent-detection receiver can exhibit quantum-limited performance despite atmospheric turbulence. The key components of such a receiver include standard receiver optics, a laser that serves as a local oscillator, a focal-plane array of photodetectors, and a signal-processing and data-acquisition assembly needed to sample the focal-plane fields and reconstruct the pulsed signal prior to detection. The received PPM-modulated laser beam and the local-oscillator beam are focused onto the photodetector array, where they are mixed in the detection process. The two lasers are of the same or nearly the same frequency. If the two lasers are of different frequencies, then the coherent detection process is characterized as heterodyne and, using traditional heterodyne-detection terminology, the difference between the two laser frequencies is denoted the intermediate frequency (IF). If the two laser beams are of the same frequency and remain aligned in phase, then the coherent detection process is characterized as homodyne (essentially, heterodyne detection at zero IF). As a result of the inherent squaring operation of each photodetector, the output current includes an IF component that contains the signal modulation. The amplitude of the IF component is proportional to the product of the local-oscillator signal amplitude and the PPM signal amplitude. Hence, by using a sufficiently strong local-oscillator signal, one can make the PPM-modulated IF signal strong enough to overcome thermal noise in the receiver circuits: this is what makes it possible to achieve near-quantum-limited detection in the presence of strong background. Following quantum-limited coherent detection, the outputs of the individual photodetectors are automatically aligned in phase by use of one or more adaptive array compensation algorithms [e.g., the least-mean-square (LMS) algorithm]. Then the outputs are combined and the resulting signal is processed to extract the high-rate information, as though the PPM signal were received by a single photodetector. In a continuing series of experiments to test this method (see Fig. 1), the local oscillator has a wavelength of 1,064 nm, and another laser is used as a signal transmitter at a slightly different wavelength to establish an IF of about 6 MHz. There are 16 photodetectors in a 4 4 focal-plane array; the detector outputs are digitized at a sampling rate of 25 MHz, and the signals in digital form are combined by use of the LMS algorithm. Convergence of the adaptive combining algorithm in the presence of simulated atmospheric turbulence for optical PPM signals has already been demonstrated in the laboratory; the combined output is shown in Fig. 2(a), and Fig. 2(b) shows the behavior of the phase of the combining weights as a function of time (or samples). We observe that the phase of the weights has a sawtooth shape due to the continuously changing phase in the down-converted output, which is not exactly at zero frequency. Detailed performance analysis of this coherent free-space optical communication system in the presence of simulated atmospheric turbulence is currently under way.

Vilnrotter, Victor↗

A Measurement of the Cosmic Microwave Background Lensing Potential and Power Spectrum from 500 deg 2 of SPTpol Temperature and Polarization Data

In this work, we present a measurement of the cosmic microwave background (CMB) lensing potential using 500 deg$^2$ of 150 GHz data from the SPTpol receiver on the South Pole Telescope. The lensing potential is reconstructed with signal-to-noise per mode greater than unity at lensing multipoles $L \lesssim 250$, using a quadratic estimator on a combination of CMB temperature and polarization maps. We report measurements of the lensing potential power spectrum in the multipole range of $100< L < 2000$ from sets of temperature-only, polarization-only, and minimum-variance estimators. We measure the lensing amplitude by taking the ratio of the measured spectrum to the expected spectrum from the best-fit $\Lambda$CDM model to the $\textit{Planck}$ 2015 TT+lowP+lensing dataset. For the minimum-variance estimator, we find $A_{\rm{MV}} = 0.944 \pm 0.058{\rm (Stat.)}\pm0.025{\rm (Sys.)}$; restricting to only polarization data, we find $A_{\rm{POL}} = 0.906 \pm 0.090 {\rm (Stat.)} \pm 0.040 {\rm (Sys.)}$. Considering statistical uncertainties alone, this is the most precise polarization-only lensing amplitude constraint to date (10.1 $\sigma$), and is more precise than our temperature-only constraint. We perform null tests and consistency checks and find no evidence for significant contamination.

79 ASTRONOMY AND ASTROPHYSICS↗

Planck 2013 results. II. Low Frequency Instrument data processing

We describe the data processing pipeline of the Planck Low Frequency Instrument (LFI) data processing centre (DPC) to create and characterize full-sky maps based on the first 15.5 months of operations at 30, 44, and 70 GHz. In particular, we discuss the various steps involved in reducing the data, from telemetry packets through to the production of cleaned, calibrated timelines and calibrated frequency maps. Data are continuously calibrated using the modulation induced on the mean temperature of the cosmic microwave background radiation by the proper motion of the spacecraft. Sky signals other than the dipole are removed by an iterative procedure based on simultaneous fitting of calibration parameters and sky maps. Noise properties are estimated from time-ordered data after the sky signal has been removed, using a generalized least squares map-making algorithm. A destriping code (Madam) is employed to combine radiometric data and pointing information into sky maps, minimizing the variance of correlated noise. Noise covariance matrices, required to compute statistical uncertainties on LFI and Planck products, are also produced. Main beams are estimated down to the &approx;-20 dB level using Jupiter transits, which are also used for the geometrical calibration of the focal plane.

79 ASTRONOMY AND ASTROPHYSICS↗

The Atacama Cosmology Telescope: Mitigating the Impact of Extragalactic Foregrounds for the DR6 Cosmic Microwave Background Lensing Analysis

We investigate the impact and mitigation of extragalactic foregrounds for the cosmic microwave background (CMB) lensing power spectrum analysis of Atacama Cosmology Telescope (ACT) data release 6 (DR6) data. Two independent microwave sky simulations are used to test a range of mitigation strategies. We demonstrate that finding and then subtracting point sources, finding and then subtracting models of clusters, and using a profile bias-hardened lensing estimator together reduce the fractional biases to well below statistical uncertainties, with the inferred lensing amplitude, A lens , biased by less than 0.2σ. We also show that another method where a model for the cosmic infrared background (CIB) contribution is deprojected and high-frequency data from Planck is included has similar performance. Other frequency-cleaned options do not perform as well, either incurring a large noise cost or resulting in biased recovery of the lensing spectrum. In addition to these simulation-based tests, we also present null tests on the ACT DR6 data for sensitivity of our lensing spectrum estimation to differences in foreground levels between the two ACT frequencies used, while nulling the CMB lensing signal. These tests pass whether the nulling is performed at the map or bandpower level. The CIB-deprojected measurement performed on the DR6 data is consistent with our baseline measurement, implying that contamination from the CIB is unlikely to significantly bias the DR6 lensing spectrum. This collection of tests gives confidence that the ACT DR6 lensing measurements and cosmological constraints presented in companion papers to this work are robust to extragalactic foregrounds.

79 ASTRONOMY AND ASTROPHYSICS↗